• Title/Summary/Keyword: Curing at Room Temperature

Search Result 117, Processing Time 0.03 seconds

황색종 잎담배 공동건조장의 환경개선

  • 신승구;백기현;이승철
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.2
    • /
    • pp.160-165
    • /
    • 1998
  • The Joint curing barns for flue-cured tobacco is a favorite with the tobacco farmers in Korea. However, most of farmer utilizing the joint curing barns indicated many problems such as high temperature and noise in the working room and a dry of cured leaves in the storage room. A structure of Joint curing barns has been modified to meet the needs of tobacco farmers. Compared with the unimproved joint curing barns, the improved one showed that the noise of workshop decreased about 7.7~10.8db, the amount of $CO_2$ decreased 40~50ppm in a working room and 80~100ppm in a machine room. Ammonia gas decreased 0.29mg/㎥ and the temperature of a working room dropped about 2.1~3.5$^{\circ}C$. The amount of air flow in a working room increased 23.2% at a site being 2m away from the entrance and 30.8% at a center. The inner temperature of the improved storage room showed that maximum temperature dropped about 3$^{\circ}C$, minimum temperature was high about 2$^{\circ}C$. The highest relative humidity was low 6%, the lowest one increased high about 10% when compared with the unimproved joint curing barns.

  • PDF

Bench-Curing Acrylic Resins (ACRYLIC RESIN의 BENCH-CURING에 관하여)

  • Kim, Hyun-Mi
    • Journal of Technologic Dentistry
    • /
    • v.12 no.1
    • /
    • pp.103-106
    • /
    • 1990
  • The purpose of this study was to determine if homogeneity of the resin associated with benchcuring could be obtained in the curing unit as the water increased from room temperature to curing temperature. The results of the experiment were as follows : 1. Long periods of bench-curing are not necessary. 2. Bench-curing can take place in the water bath of the curing unit. When this procedure is used, the water should be far enough below the temerature at which active polymerization of the resin proceeds to allow the bench-curing to occur.

  • PDF

Warping Analysis of Unsymmetric Laminated Composites (비대칭 복합적층판 의 Warping 해석)

  • 전완주;홍창선
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.4
    • /
    • pp.404-409
    • /
    • 1983
  • The warping of unsymmetric laminated composites is induced by residual curing stress at the room temperature. Classical lamination theory (C.L.T.) predicts the room temperature shapes of all unsymmetric laminates to be a saddle. Experimental observations, however, indicate some unsymmetric laminated composites have cylindrical room temperature shapes. This anomalous behavior is explained by the extention of C.L.T. which involves Von Karman's large deflection theory. It is shown that, depending on the thickness, width, length, curing temperature and room temperature of the laminate, critical boundaries of the shape change are determined. Theoretical predictions are compared with experimental results of Toray Graphite/Epoxy {O$_{n}$/90$_{n}$}$_{T}$./....

Effect of Heat-treatment on the Electrical Properties of Polyurethane Resin (열처리조건이 폴리우레탄수지의 전기적 특성에 미치는 영향에 관한 연구)

  • Cho, Jung-Soo;Kwak, Young-Soon;Lee, Jong-Ho;Kwak, Byung-Ku
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.293-295
    • /
    • 1987
  • This paper deals with the dielectric properties dielectric breakdown strength and mechanical tensile properties according to heat - treatment condition of polyurethane resin. This resin is heat - treated over a range of temperature from $50^{\circ}C$ to $150^{\circ}C$. It is shown that the dielectric dissipation factor decreases with increase of heat - treatment temperature of the sample exept for the sample heat - treated at $150^{\circ}C$. The maximum dielectric breakdown strength is appeared for the sample heat - treated for 10 hours at $100^{\circ}C$, after curing for 24 hours at room temperature. The optimal heat - treatment condition in the view point of the electrical and mechanical properties is appeared for the sample heat - treated for 10 hours at $100^{\circ}C$, after curing for 24 hours at room temperature.

  • PDF

The Measurement of Exothermic Temperature During Polymerization of Various Direct Resins. (각종 치과용 다이렉트 레진의 중합 반응시 열 측정)

  • Yun, Joung-Hyun
    • The Journal of the Korean dental association
    • /
    • v.11 no.1
    • /
    • pp.37-40
    • /
    • 1973
  • The auther measured exothermic tempreature of the 5 kinds of direct resins during polymerization. Direct resins were mixed into the rubber cup(550-600㎣ in volume) with grass rod at room temperature (23.6℃) for 30 seconds and thermometer was placed approximately at the geometric center of the resin mass in the rubber cup. Polymer-monomer ratio was determined by instruction of the packages. The results were as follows. 1) The heat generated during polymerization was under 47.3℃. 2) The time at which the highest temperature is reached during polymerization was within 20.5 minutes. 3) Slow curing resins produced lower heat than quick curing resins and quick curing resins presented higher temperature than slow curing resins. 4) The highest temperature was sustained momentarily.

  • PDF

A Study on the Development and Dielectric Properties of Insulating Materials for Super-Conductor -For Matrix of Composite Materials- (초전도체 절연용 재료의 전기적 절연 특성과 개발에 관한 연구-복합 재료의 매트릭스에 대하여-)

  • 조정수;최세원;김종경;이규철;이종호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.7
    • /
    • pp.511-523
    • /
    • 1989
  • This paper investigates physical properties, the electrical and mechanical characteristics of the epoxy resin with different curing methods and postcuring conditions at room temperature or cryogenic temperature (LN2). According to the results in this paper, first, it is found that the physical properties, electrical and mechanical characteristics of the epoxy resin are largely affected by the interior reaction temperature on the curing. Thus, in the fabrication of the sample, several excellent characteristics of the sample are obtained by controlling the interior reaction temperature of the epoxy resin. Second, the sample having optimal electrical and mechanical characteristics is obtained for the repetitive post-curing method at 100c in view point of the post-curing conditions of the epoxy resin. Third, it appears that tan and characteristics at LN2 temperature are about half of those at room temperature. Fourth, it appears that the dielectric strength of the epoxy resin at LN2 temperature is higher by about 0.6-1.0 MV/cm than that at room temperature. The heat-aging of the epoxy resin due to the micro-defect and excess fever-movement have been noticed to affect dielectric strength at LN2 temperature more significantly than at room temperature.

AN EXPERIMENTAL STUDY ON THE DIMENSIONAL CHANGES OF RELINED DENTURES AND MECHANICAL PROPERTIES AND SURFACE TEXTURES OF SEVERAL RESINS USED IN DENTURE RELINING (수종 레진으로 의치상 조직면 개조시 의치상의 크기변화와 물리적 성질 및 표면상태 비교 연구)

  • Lee, Chang-Han;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.25-41
    • /
    • 1990
  • The purpose of this study was to evaluate and compare the dimensional changes of relined dentures with a light-curing resin, a heat-curing resin, and a direct, hard reline resin. And also to measure the transverse strength, impact strength, surface hardness of the three resins used in relining. The surface textures of three resins also of evaluated by using scanning electron microscope. Through analyses on the data from this study, the following conclusions were obtained. 1. Impact strength of heat-curing resin was highest, and direct, hard reline resin higher, light-curing resin lowest. 2. Transverse strength of heat-curing resin was highest, and direct, hard reline resin and light-curing resin was lower and not signiicantly different. 3. Surface hardness of light-curing resin was lighest, heat-curing resin higher, and direct, hard reline resin was lowest. 4. After storage of the relined dentures for 1 day and 1 week in water at room temperature, linear shrinkage of distance between the reference points in the maxillary base relined with direct, hard reline resin was lowest, and those relined with light-curing resin and heat-curing resin were lower and were not significantly different. 5. After storage for 4 weeks in orator at room tempeature, linear shrinkage of distance between ridge crests of dentures relined with heat-curing resin was highest and that of distance between denture borders was not significantly different. 6. The dimensional changes of relined dentures during storage in water was not significant except those of distance between denture borders relined with light-curing resin at 1 day and 1 week storage in water. 7. At low magnification (x40) of SEM examination, the surface textures of three resins were similar except light-curing resin which had some defects. At high magnification (x200), the surface textures of hard, direct reline resin were smooth with little defects, but those of heat-curing resin and light-curing resin w ere irregular.

  • PDF

A comparative study on the mechanical properties of ultra early strength steel fiber concrete

  • Yi-Chun Lai;Ming-Hui Lee;Yuh-Shiou Tai
    • Advances in concrete construction
    • /
    • v.16 no.5
    • /
    • pp.255-267
    • /
    • 2023
  • The production of ultra-early-strength concrete (UESC) traditionally involves complexity or necessitates high-temperature curing conditions. However, this study aimed to achieve ultra-early-strength performance solely through room-temperature curing. Experimental results demonstrate that under room-temperature (28℃) curing conditions, the concrete attained compressive strengths of 20 MPa at 4 hours and 69.6 MPa at 24 hours. Additionally, it exhibited a flexural strength of 7.5 MPa after 24 hours. In contrast, conventional concrete typically reaches around 20.6 MPa (3,000 psi) after approximately 28 days, highlighting the rapid strength development of the UESC. This swift attainment of compressive strength represents a significant advancement for engineering purposes. Small amounts of steel fibers (0.5% and 1% by volume, respectively) were added to address potential concrete cracking due to early hydration heat and enhance mechanical properties. This allowed observation of the effects of different volume contents on ultra-early-strength fiber-reinforced concrete (UESFRC). Furthermore, the compressive strength of 0.5% and 1% UESFRC increased by 16.3% and 31.3%, respectively, while the flexural strength increased by 37.1% and 47.9%. Moreover, toughness increased by 58.2 and 69.7 times, respectively. These findings offer an effective solution for future emergency applications in public works.

Studies on the Pretreatment Effect of Ginger on Long-term Storage (생강의 저장 전처리 효과에 관한 연구)

  • Chung, Tae-Yon;Lee, Se-Eun;Jeong, Mun-Cheol;Kim, Dong-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.458-463
    • /
    • 1996
  • Fresh ginger harvested in Seosan, Choongchengnam-do, was used to investigate the pretreatment effect before long-term storage. Wounded ginger were cured at the temperature of 25, 30, $35^{\circ}C$ and the RH 83 and 93% for 1, 3, 5, 7 days, respectively Then the cured ginger were stored in the laboratory scale storage room ($12^{\circ}C,$ 95% RH) in order to find out the optimum curing condition. At a constant temperature and a RH. the longer ginger were cured, the more their weight was decreased; at a constant temperature and a curing period, the higher RH was, the less weight was lost. During the curing process, sprouting rate was accelerated at temperature higher than $30^{\circ}C$ and humidity higher than 90%; mold growing was observed at any temperature and humidity, but especially at $35^{\circ}C$ the rate was relatively faster when the curing time was increased. Hardness of wound surface cured at 93% RH was relatively higher than those cured at 83% RH at all temperatures. The weight loss of store ginger after curing was $2.0{\sim}8.2$ after 30 days and $7.2{\sim}14.2%$ after 60 days storage. Compared with all results through a screening procedure, the condition of 3-days curing at $25^{\circ}C$ and 93% RH showed th best result for minimizing quality changes during storage.

  • PDF

Effects of pre-curing process on improvement of the compressive strength of IGCC-slag-based-geopolymer (IGCC 용융 슬래그로 제조된 지오폴리머의 강도증진에 Pre-curing이 미치는 영향)

  • Park, Soo-bin;Kim, Kang-duk;Kang, Seung-gu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.6
    • /
    • pp.295-302
    • /
    • 2017
  • In this study, the effect of pre-curing process on the enhancement of mechanical properties of IGCC-slag-based-geopolymer was studied. Pre-curing is a process in which the green geopolymer is left at room temperature for a certain period of time prior to the high-temperature curing, and it is known as increasing the strength of a specimen. Therefore, in this experiment, the compressive strength of the geopolymers was measured according to various pre-curing conditions, and microstructure and crystal phase changes were observed by SEM and XRD, respectively. The W/S ratio was determined to be 0.26, which can offer the maximum geopolymer strength with easy molding ability, and the concentration of the alkali solution was 15 M. Pre-curing was performed at room temperature for 0 to 27 days. Compressive strength of the geopolymer made with pre-curing process increased by 36~87 % compared with the specimens made with no pre-curing process. Those improved compressive strength for the pre-cured geopolymer was confirmed owing to promotion effect of pre-curing process on generation of C-S-H gel and zeolite phases, which were analyzed using by XRD and SEM measurement.