• Title/Summary/Keyword: Cuff pressure

Search Result 104, Processing Time 0.022 seconds

Blood Pressure Simulator using An Optimal Controller with Disturbance Observer

  • Kim, Cheol-Han;Han, Gi-Bong;Lee, Hyun-Chul;Kim, Yun-Jin;Nam, Ki-Gon;SaGong, Geon;Lee, Young-Jin;Lee, Kwon-Soon;Jeon, Gye-Rok;Ye, Soo-Young
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권6호
    • /
    • pp.643-651
    • /
    • 2007
  • The various blood pressure simulators have been proposed to evaluate and improve the performance of the automatic sphygmomanometer. These have some problems such as the deviation of the actual blood pressure waveform, limitation in the blood pressure condition of the simulator, or difficulty in displaying the blood flow. An improved simulator using disturbance observer is proposed to supplement the current problems of the blood pressure simulator. The proposed simulator has an artificial arm model capable of feeding appropriate fluids that can generate the blood pressure waveform to evaluate the automatic sphygmomanometer. A controller was designed and thereafter, simulation was performed to control the output signal with respect to the reference input in the fluid dynamic model using the proposed proportional control valve. To minimize the external fluctuation of pressure applied to the artificial arm, a disturbance observer was designed on the plant. A hybrid controller combined with a proportional controller and feed-forward controller was fabricated after applying a disturbance observer to the control plant. Comparison of the simulations between the conventional proportional controller and the proposed hybrid controller indicated that even though the former showed good control performance without disturbance, it was affected by the disturbance signal induced by the cuff. The latter exhibited an excellent performance under both situations.

선천성 고혈압 렛드에서 혈압 및 내피의 기능장해에 대한 protopanaxatriol계 배당체의 효과 (Effect of Protopanaxatriol Ginsenosides on the Blood Pressure and Endothelial Dysfunction In the Aorta of Spontaneously Hypertensive Rats)

  • 김낙두;김순회
    • Journal of Ginseng Research
    • /
    • 제21권2호
    • /
    • pp.119-124
    • /
    • 1997
  • Chronic hypertension is associated with impaired endothelial function such as reduced synthesis/release of endothelium-derived relaxing factor(EDRF, nitric oxide) and increased synthesis/release of endothelium-derived contracting factor(EDCF) including prostaglandin endoperoxide($PGH_2$) , superoxide anion both in animals and in humans. We have previously shown that ginsenosides lower the blood pressure and enhance the release of nitric oxide(NO) from endothelial cells in the rat aorta of the normotensive rats. The aim of the present study is to examine whether in vivo treatment of spontaneously hypertensive rats(SHRs) with protopanaxatriol ginsenosides(PPT) reduces the blood pressure and improves endothelial function in the isolated thoracic aorta of SHR. In addition, the contractile response to $PGH_2$ and superoxide anion in the aorta treated with PPT was assessed. SHRs at the age of 16 weeks were savaged with PPT(30 mg/kg/ day) for 2 weeks and systolic blood pressure was measured by the tail-cuff method. Whereas blood pressure was significantly increased in SHRs by 5.4 mmHg during this period of treatment, treatment of SHRs with PPT blocked the elevation of blood pressure. Endothelium-dependent relaxation to acetylcholine was significantly increased in the PPT-treated animals. $PGH_2$- and oxygen-derived free radical-induced contractions were significantly suppressed in aortic rings without endothelium from PPT-treated SHR. These findings indicate that PPT reduces the blood pressure of SHR, which may be associated with either increase of NO release or by antagonizing superoxide anion and PGH2 in the aortic smooth muscle.

  • PDF

Cucumber (Cucumis sativus L.) Fruit and Combination with Losartan Attenuate the Elevation of Blood Pressure in Hypertensive Rats Induced by Angiotensin II

  • Tomi Hendrayana;Klaudia Yoana;I Ketut Adnyana;Elin Yulinah Sukandar
    • 대한약침학회지
    • /
    • 제26권4호
    • /
    • pp.298-306
    • /
    • 2023
  • Objectives: Cucumis sativus L. (C. sativus) is vegetable commonly used for managing blood pressure and often consumed in combination with standard antihypertensive therapy, despite lack of scientific evidence supporting their use. Combination of herbs and standard medication could have positive or negative effects. Therefore, this study aimed to evaluate the antihypertensive activity of C. sativus and the combined effect with losartan in the hypertensive rat model induced by angiotensin II. Angiotensin II is a component of the renin-angiotensin-aldosterone system that, upon binding to its receptor, constricts blood vessels leading to elevation of blood pressure. Methods: In an antihypertensive study, rats received C. sativus orally at doses of 9, 18, 27, and 36 mg/kg (full dose); while in a combination study, animals received losartan 2.25 mg/kg combined by either with C. sativus 9 or 18 mg/kg. The standards group received losartan 2.25 mg/kg or 4.5 mg/kg (full dose). Results: Blood pressure was measured using the tail-cuff method. C. sativus significantly attenuated angiotensin II-induced hypertension as observed in groups receiving C. sativus at 9, 18, 27, and 36 mg/kg at 30 minutes after induction showed the average change (Δ) of systolic blood pressure (SBP) and diastolic blood pressure (DBP) with respect to time zero were 28.8/18.3, 24.8/15.8, 22.8/15.5, and 11.5/9.0 mmHg, respectively. Whereas the average change (Δ) of SBP and DBP in the rats receiving the combination of half doses of C. sativus and losartan were 8.8/9.0 mmHg, respectively. These diminished effects were better than a full dose of C. sativus and comparable with a full dose of losartan (6.5/7.8 mmHg). Conclusion: The present findings indicate that C. sativus dose-dependently blocks blood pressure elevation induced by angiotensin II. The combination of half dose of C. sativus and losartan has an additive effect in lowering blood pressure.

Disagreement between direct and indirect blood pressure measurements obtained from minipigs

  • Lee, Won-Jae;Park, Lisa Soyeon
    • 대한수의학회지
    • /
    • 제58권3호
    • /
    • pp.131-136
    • /
    • 2018
  • Blood pressure (BP) measurement plays a pivotal role in veterinary medicine for diagnosing cardiovascular disorders and monitoring anesthesia of animals. Although indirect BP measurement has been widely applied to monitor BP because of its convenience and non-invasiveness, it is still unclear whether indirect BP measurement is compatible with direct BP measurement in minipigs. In addition, the effect of animal posture during BP measurement is not well understood in minipigs despite its importance to cardiovascular performance. Therefore, both systolic and diastolic arterial BPs in minipigs were measured via femoral artery catheterization for direct BP measurement and using a compressive cuff as an indirect BP measurement under the dorsal or right lateral recumbent postures. Numerical values were processed by the Bland-Altman method to calculate the bias ${\pm}$ SD and the limits of agreement (LOA). In accordance with the American College of Veterinary Internal Medicine guidelines, the results between direct and indirect BP measurements were determined as apparent disagreements in both systolic and diastolic arterial BPs under all postures because of large bias ${\pm}$ SD and wide LOA. The results of the present will help prevent misinterpretation of the anesthetized patient's condition during monitoring of BP by indirect measurement.

PTT를 이용한 자전거 운동 중 지속적인 혈압의 예측 (Continuous Blood Pressure Prediction Using PTT During Exercise)

  • 김철승;문기욱;권정훈;엄광문
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.370-375
    • /
    • 2006
  • The purpose of this work is to predict the systolic blood pressure (BP) during exercise from pulse transit time (PTT) for warning of possible danger. PTT was calculated as the time between R-peak of ECG and the peak of differential photoplethysmograph (PPG). For the PTT-BP model, we used regress equations from previous studies and 3 kinds of new models combining linear and nonlinear regress equation. The model parameters were estimated with the data measured under low to middle intensity exercise, and then was tested with the data measured under high intensity exercise. Predicted BP values after high intensity exercise were compared with those measured by cuff-type sphygmomanometer. The results showed that the error between measured and predicted values were acceptable for the monitoring BP. We tested PTT-BP models 1 month after the identification without further calibration. Models could predict the BP and the errors between measured and predicted BP were about 5mmHg. The suggested system is expected to be helpful in recognizing any danger during exercise.

휴대용 및 웨어러블 측정기를 위한 ECG와 PPG 신호를 활용한 합성곱 신경망 알고리즘 기반의 비가압식 혈압 추정 방법 (Cuffless Blood Pressure Estimation Based on a Convolutional Neural Network using PPG and ECG Signals for Portable or Wearable Blood Pressure Devices)

  • 조진우;최아영
    • 한국산업정보학회논문지
    • /
    • 제25권3호
    • /
    • pp.1-10
    • /
    • 2020
  • 본 논문에서는 시계열 심전도 (Electrocardiogram: ECG) 및 광전용맥파 측정센서 (Photoplethysmography: PPG)을 이용하여 혈압을 추정하는 알고리즘을 제안한다. 혈압 (Blood pressure: BP)을 추정하기 위해 주기적 입력 신호를 생성하고 차동 및 임계값 방법에 따라 잡음을 제거한 다음 합성곱 신경망 알고리즘을 기반으로 하여 수축기 혈압과 이완기 혈압을 예측한다. 본 논문에서 사용된 데이터는 MIMIC 데이터베이스에서 총 3.1GB의 49명의 환자 데이터를 사용하였다. 실험결과 수축기 혈압의 평균 제곱근 오차는 5.80mmHg, 이완기 혈압의 예측 오차는 2.78mmHg을 나타내었다. 또한, 영국 고혈압 협회가 제안한 혈압계 평가 방법을 적용하였을 때, 최고 성능인 등급 A를 만족함을 확인할 수 있었다.

자동혈압계 성능평가를 위한 인체혈압 시뮬레이터 개발 (A Simulator for the Validation of Non-invasive Blood Pressure (NIBP) Monitoring Devices)

  • 도일;임현균;안봉영;지영준;이종실;오재훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권3호
    • /
    • pp.111-115
    • /
    • 2017
  • Blood pressure is one of the important vital signs for monitoring the medical condition of a patient. Automated NIBP(non-invasive blood pressure) monitoring devices calculate systolic and diastolic blood pressures from the oscillation in cuff pressure caused by a pulsation of an artery. To validate the NIBP devices, we developed a simulator to supply the oscillometric waveforms obtained from human subjects. The simulator provided pressure pulses to device-under-test and device readings were compared to the auscultatory references. Fully automated simulation system including OCR(optical character recognition) were developed and used for NIBP monitoring devices. The validation results using the simulator agreed well with previous clinical validation. More validation studies using the standardized oscillometric waveforms would be required for the replacement of clinical trials to validate a new automated NIBP monitoring device.

Electroacupuncture Delays Development of Hypertension through Increase of NO Level in Spontaneously Hypertensive Rats

  • Hwang, Hye-Suk;Kim, Yu-Sung;Lee, Ji-Eun;Han, Kyung-Ju;Choi, Sun-Mi;Koo, Sung-Tae
    • 한국한의학연구원논문집
    • /
    • 제13권2호통권20호
    • /
    • pp.149-155
    • /
    • 2007
  • Objective : Using a spontaneously hypertensive rat (SHR) model of essential hypertension, this study investigated whether electroacupuncture (EA) could reduce early stage hypertension by examining whether EA increased nitric oxide (NO) levels in plasma, which compensates for elevated blood pressure (BP). Methods : EA was applied to the acupoint, Baekhoe (GV20), and to a non acupoint in the tail at 10 Hz and an intensity of 1 mA for 10 minutes on the first and fourth day of the week for three weeks under isoflurane anesthesia. In conscious SHR and normotensive Wistar Kyoto (WKY) rats, blood pressure was determined the day after EA treatment by the tail cuff method using an automatic BP monitoring system. We also measured NO concentration of blood serum in SHR and WKY. Results : Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were lower after 3 weeks of GV20 treatment than in non EA treated or non acupoint treated SHR rats. The NO level of plasma was significantly lower in hypertensive SHR than in normotensive WKY. EA prevented the augmentation of blood pressure, and also increased NO concentrations from $7.91{\pm}0.42$ ${\mu}M$ to $11.50{\pm}0.93$ ${\mu}M$ in SHR serum. Conclusions : We suggest that acupuncture may be an early intervention to delay the development of hypertension and enhance NO/NOS activity.

  • PDF

다중 생체 신호를 통한 손목 혈압 측정의 정확도 향상 (Improvement of the Accuracy of Wrist Noninvasive Blood Pressure Measurement Using Multiple Bio-signals)

  • 정운모;심명헌;정상오;김민용;윤찬솔;정인철;윤형로
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1606-1616
    • /
    • 2011
  • The blood pressure measuring equipment, which is being supplied and used most widely by being recognized convenience and accuracy now generally, is oscillometric blood pressure monitor. However, a change in blood pressure is basically influenced by diverse elements such as each individual's physiological status and physical condition. Thus, the measurement of blood pressure, which used single element called oscillation in blood pressure of being conveyed to cuff, is not considered on physiological elements such as cardiovascular system status and blood vessel stiffness index, and on external elements, thereby being quite in error. Accordingly, this study detected diverse bio-signals and body informations in each individual as the measurement subject such as ECG, PPG, and Korotkoff Sound in order to enhance convenience and accuracy of measuring blood pressure in the complex measurement equipment, thereby having extracted regression method for compensation in error of oscillometric blood pressure measurement on the wrist, and having improved accuracy of measuring blood pressure. To verify a method of improving accuracy, the blood pressure value in each of SBP, DBP, MAP was acquired through 4-stage experimental procedure targeting totally 51 subjects. Prior to experiment, the subjects were divided into two groups such as the experimental group for extracting regression method and the control group for verifying regression method. Its error was analyzed by comparing the reference blood pressure value, which was obtained through the auscultatory method, and the oscillometric blood pressure value on the wrist. To reduce the detected error, the blood pressure compensation regression method was calculated through multiple linear regression analysis on elements of blood pressure, individual body information, PTT, HR, K-Sound PSD change. Verification was carried out on improving significance and accuracy by applying the regression method to the data of control group. In the experimental results, as a result of confirming error on the reference blood pressure value in SBP, DBP, and MAP, which were acquired through applying regression method, the results of $-0.47{\pm}7.45$ mmHg, $-0.23{\pm}7.13$ mmHg, $0.06{\pm}6.39$ mmHg could be obtained. This is not only the numerical value of satisfying the sphygmomanometer reference of AAMI, but also shows the lower result than the numerical value in SBP : $-2.5{\pm}12.2$ mmHg, DBP : $-7.5{\pm}8.4$ mmHg, which is the mean error in the experimental results of Brram's research for verifying accuracy of Omron RX-M, which shows relatively high accuracy among wrist sphygmomanometers. Thus, the blood pressure compensation could be confirmed to be made within significant level.

저출력레이저치료가 어깨통증에 미치는 임상적 효과 (The Clinical Effects of Low Level Laser Therapy on Shoulder Pain)

  • 박경무;이길재;송윤경;임형호
    • 한방재활의학과학회지
    • /
    • 제20권1호
    • /
    • pp.183-192
    • /
    • 2010
  • Objectives : The purpose of this study is to investigate the clinical effects of low level laser therapy on shoulder pain. Methods : From October 1, 2009 to November 14, 2009, we applied 15 participants who consented to an assignment had a shoulder pain to low level laser therapy(LLLT). We treated LLLT 8 times on both upper trapezius, levator scapular, pectoralis, suboccipital, rhomboid, rotator cuff tender point for 2 weeks. To evaluate the efficiency of low level laser therapy, we used questionnaire of shoulder pain symptom, questionnaire of a day living discomfort scale, shoulder pain and disability index(SPADI) and pressure pain threshold(PPT) at before treatment and after treatment 4 times and 8 times. Results : There was a significant difference in questionnaire of shoulder pain symptom, questionnaire of a day living discomfort scale, SPADI and PPT after 8th treatment. Conclusions : Low level laser therapy for shoulder pain is effective to improve patients' symptoms measured with questionnaire of pain and a day living discomfort score, SPADI and PPT significantly.