• Title/Summary/Keyword: Cu filter

Search Result 173, Processing Time 0.029 seconds

The Effect of Paper Permeability on Cigarette Properties (종이의 투기도가 담배 물성에 미치는 영향)

  • 김영호;한영림;이문용;이영택;김정열
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.1
    • /
    • pp.64-72
    • /
    • 2001
  • The cigarette ventilation affects not only the amount of tar and nicotine delivery by a cigarette, but also the composition of the smoke. Therefore, it is important to stabilize of variability in cigarette ventilation that would be affected by changes in cigarette components. This work was conducted to determine the major factors that influence the cigarette ventilation and also to provide fundamental informations for improving the uniformity of cigarette performances. To evaluate the effect of cigarette ventilation as a dependant variable, the three independent factors were the air permeability of plugwrap, tipping paper and the filter pressure drop. We determined the effect of paper permeability on ventilation variability and the optimum condition in combinations of independent factors. The mean of cigarette ventilation was increased as plugwrap permeability increases, particularly at 26,000 CU. However, it was exhibited that standard deviation and coefficient of variation of the cigarette ventilation were decreased with increasing plugwrap permeability. At the 600 CU and 1,200 CU of tipping paper permeability, process capability index (Cp) of the cigarette ventilation increased as plugwrap permeability increases. Following the optimum condition of cigarette ventilation induced by fitted regression equation, one was to optimize 50% ventilation level is by combination with plugwrap permeability of 16,000 CU, tipping paper permeability of 810 CU, filter pressure drop of 319 mm$H_2O$, respectively.

  • PDF

Preparation and Characterization of Epitaxial $YBa_2Cu_3O_{7-\delta}$ Thin Films for Fabrication of High-$T_{c}$ Superconducting Microwave Devices (마이크로파 소자 응용을 위한 고온초전도 $YBa_2Cu_3O_{7-\delta}$ 에피택셜 박막의 제조 및 특성분석)

  • 강광용;한석길;김제하;이상렬
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.26-30
    • /
    • 1995
  • We describe the preparation and characterization of epitaxial thin films made with high temperature superconductor, $YBa_2Cu_3O_{7-\delta}$. The influence of processing parameters for YBCO thin films on MgO substrates in-situ grown by the pulsed laser deposition, including parameters of a laser beam energy, oxygen pressure, substrate temperature, target-substrate dis-tance is discussed. The characteristics of YBCO thin films were analyzed by using XRD, R-T measurement, AFM, crosssectional TEM, and RBS. For examples of microwave device applications, The fabrication and characterization of the microstrip lowpass filter and bandpass filter are also presented.

  • PDF

A Study on the Reduction of Exposure Dose and Contrast Improvement by Use of Heavy Elements Filter (X선 진단영역에서 중원소(Ho) 여과판 사용에 따른 피폭선량 감소와 대조도 개선에 관한 연구)

  • Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.91-96
    • /
    • 2000
  • This work was on the reduction of exposure dose and contrast improvement by Use of Heavy Elements Filter From the result of experimental evaluation, it was found that the beam harding of X-ray was not showed in Ho and Gd, heavy elements filters, contrast to Cu and Al filters In which the harding showed. And the ratio of transit dose to surface dose and the load of X-ray tube increase in order of Al, Cu, Gd and Ho, respectively. The contrast of X-ray images using the intensifying screen and the input phosphor showed the higher value in order of Cu, Al, Gd and Ho. Therefore, in the case of using contrast media and phosphor in region of diagnostic radiology, X-ray image quality depends primarily on kVp and heavy elements filters.

  • PDF

A Study on Antibacterial Assesment of High Efficiency Antibacterial Air Filter (고효율 항균 필터의 항균력 평가에 관한 연구)

  • 권혁구;정진도;류해열;정우성;박덕신
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.549-554
    • /
    • 2002
  • Recently, interest in hygiene has been arouse in the health care field. Consequently, Filters with antibacterial agent applied to improve air quality by sterilizing bacteria, fungi, etc. We actually installed antibacterial air filter containing 2.5wt%Ag zeolite on the air intake route to air-conditioner in passenger cu, and evaluated filter's performance on antibacterial effect. By the microbe liquid spattering method, we found that the antibacterial air filter has notably sufficient antibacterial efficiency against standard strains and wild type strains. Antibacterial effect was observed at whole area of filter media by zone of inhibition test. The evaluation of microbe quantity was conducted through mixing dilution plate culture method. In comparison with ordinary filter, the amount of germs attached on antibacterial air filters was larger. The amount of germs attached on ordinary filters was very small since ordinary filters contained less dust. In comparison in antibacterial air filter with thickness, the amount of germs attached on 9mm filter was smaller than that of on 6mm filter. i.e. thicker filter, superior efficiency.

  • PDF

A Study on Reduction of Exposure Dose in Tomography of the Chest (흉부단층촬영시(胸部斷層撮影時) 피폭선량(被曝線量)의 저감(低減)에 관(關)한 연구(硏究))

  • Lino, Yu;Lee, Man-Koo;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakurai, Tatsuya;Park, Yong-Hee;Kim, Chang-Nam;Shin, Tong-Sik
    • Journal of radiological science and technology
    • /
    • v.17 no.2
    • /
    • pp.29-35
    • /
    • 1994
  • Tomographic examination requires several times of exposure usually, therefore, reduction of radiation dose per exposure without loss of image quality proves of great benefit to patient. We compared the exposure doses under the following experimental conditions, A and B. A is the combination of SRO 380(rare earth screen) and SRH(high contrast film) with additional Cu filters or without. B is the widely used combination which is BH-III and Cronex-4 without additional filter. As a result, comparing with the condition B, the condition A with additional filter of Cu 0.15 mm + Al 0.7 mm, Cu 0.4 mm+ Al 0.4 mm and Cu 0.8 mm showed better Image quality and lower surface dose, 44 %, 31 % and 24 % of the condition B, respectively.

  • PDF

Magnetoresistance of IrMn-Based Spin Filter Specular Spin Valves (IrMn 스핀필터 스페큘라 스핀밸브의 자기저항 특성)

  • Hwang, J.Y.;Rhee, J.R.
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.6
    • /
    • pp.236-239
    • /
    • 2004
  • We studied the specular spin valve (SSV) having the spin filter layer (SFL) in contact with the ultrathin free layer composed of Ta3/NiFe2/IrMn7/CoFel/(NOLl)/CoFe2/Cu1.8/CoFe( $t_{F}$)/Cu( $t_{SF}$ )/(NOL2)/Ta3.5 (in nm) by the magnetron sputtering system. For this antiferromagnetic I $r_{22}$M $n_{78}$-pinned spin filter specular spin valve (SFSSV) films, an optimal magnetoresistance (MR) ratio of 11.9% was obtained when both the free layer thickness ( $t_{F}$) and the SFL thickness ( $t_{SF}$ ) were 1.5 nm, and the MR ratio higher than 11% was maintained even when the $t_{F}$ was reduced to 1.0 nm. It was due to increase of specular electron by the nano-oxide layer (NOL) and of current shunting through the SFL. Moreover, the interlayer coupling field ( $H_{int}$) between free layer and pinned layer could be explained by considering the RKKY and magnetostatic coupling. The coercivity of the free layer ( $H_{cf}$ ) was significantly reduced as compared to the traditional spin valve (TSV), and was remained as low as 4 Oe when the $t_{F}$ varied from 1 nm to 4 urn. It was found that the SFL made it possible to reduce the free layer thickness and enhance the MR ratio without degrading the soft magnetic property of the free layer.

RF Integrated Electromagnetic-Noise Filters Incorporated with Nano-granular Co41Fe38AI13O8 Soft Magnetic Thin Films on Coplanar Transmission Line

  • Sohn, Jae-Cheon;Yamaguchi Masahiro;Lim, Sang-Ho;Han, Suk-Hee
    • Journal of Magnetics
    • /
    • v.10 no.4
    • /
    • pp.163-170
    • /
    • 2005
  • The RF integrated noise filters are fabricated by photolithography. The stack for the electromagnetic noise filters consists of the nano-granular ($Co_{41}Fe_{38}AI_{13}O_8$) soft magnetic film / $SiO_2$ / Cu transmission line / seed layer (Cu/Ti) / $SiO_2$-substrate. A good signal-attenuation feature along with a low signal-reflection feature is observed in the present filters. Especially in the noise filter incorporated with a $Co_{41}Fe_{38}AI_{13}O_8$ magnetic film with lateral dimensions of $2000{\mu}m$ wide, 15 mm long and $1{\mu}m$ thick, the maximum magnitude of signal attenuation reaches -55 dB, and the magnitude of signal reflection is below -10 dB in the overall frequency range. And this level of signal attenuation is much larger than that of a noise filter incorporated with a Fe magnetic film.

Implementation of Ladder Type SAW Filters for Mobile Communication (이동통신 시스템을 위한 사다리형 표면탄성파 필터의 구현)

  • 이택주;정덕진
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.3
    • /
    • pp.1-9
    • /
    • 2003
  • In this paper, we designed a highly suppressed sidelobe ladder type RF SAW bandpass filter based on 1-port resonator, for 800 MHz mobile communication system. In order to get the highest device characteristics, we optimized some important parameters such as the electrode thickness, electrode lambda weghting of the reflectors, and static capacitance ratio. Furthermore, we fabricated the Tx and Rx. filter using optimized parameters. Implemented filters can be used in 800 MHz mobile communication system and external impedance matching circuits are not needed. RF filter was fabricated on 36$^{\circ}$LiTaO$_3$ substrates with Al-Cu (W 3 %)and mounted 3.8mm$\times$3.8mm$\times$1.5mm SMD package. Developed filters has 2.3 dB insertion loss in the 25 MHz pass-band, 33MHz with 3-dB insertion loss, stop-band rejection of 30 dB, passband ripple is less than 0.5 The power durability of the filters measured about 3.5W and the maximum temperature variation within -2$0^{\circ}C$~8$0^{\circ}C$ was 0.09 dB/$^{\circ}C$ of 3-dB insertion loss.

The Effect of Filter Paper on the Results of Trace Analysis (거름종이가 미량 분석 결과에 미치는 영향)

  • Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.174-178
    • /
    • 2003
  • Analytical chemists frequently use filter papers during the course of experiments without any hesitation. However, the results of analysis could be deteriorated by the various ions which are extracted from filter papers. In some filter paper made for qualitative use, about $300{\mu}g$ sodium and many other cations were detected. Although the quantities of contaminants was low in the filter paper made for quantitative use, significant amount of Fe, Si, Al, Cu and Zn was detected as well as alkali element. Many cations and anions were also detected in the filtrate obtained from the glass fiber filter.

High Temperature Superconducting Pseudo-Lumped Element Bandpass Filter

  • Min, Byoung-Chul;Choi, Young-Hwan;Kim, Hong-Teuk;Moon, Seung-Hyun;Lee, Seung-Min;Oh, Byung-Du
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.42-46
    • /
    • 1999
  • A high-temperature superconducting 1.78 GHz bandpass filter, designed for PCS applications, is presented. The structure consists of microstrip pseudo-lumped elements, which enables miniaturization of the filter. A 5-pole microstrip filter could be realized on a 37 mm $\times$ 9 mm $LaAlO_3$ substrate, using double-sided high-temperature superconducting $YBa_2Cu_3O{7-\delta}$ thin film. This filter showed 0.7 % fractional bandwidth, 0.3 dB insertion loss, and 12 dB return loss in the passband at 60 K.

  • PDF