• Title/Summary/Keyword: Ct매개변수

Search Result 26, Processing Time 0.026 seconds

Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT (SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가)

  • Kim, Sang Gyu;Kim, Jung Yul;Park, Min Soo;Jo, Seung Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.3-7
    • /
    • 2014
  • Purpose SPECT/CT scan to be performed attenuation correction on the basis of CT induce an overestimation of the site due to the beam hardening artifact by metal cover and reduce the images quality. Therefore, this study using a phantom that has been inserted artificial hip joint investigated that effect on the SPECT/CT image causing by metal artifact for varying the parameters of the Attenuation Map. Materials and Methods Siemens Symbia T16 SPECT/CT equipment was used. Artificial hip joint was inserted to SPECT/PET phantom, 17 mm sphere of Bright Streak area in CT image was filled with Tc-99m so that the radiation activity was 8 times compared to background. And then Hot and Background was measured in varying Wide Beam Coefficient on Attenuation Map and RBR (Region to Background Ratio) of Metal and Non-Metal was calculated and analyzed depending on the presence or absence of the hip joint. Results It tended to hot count of Non-Metal and Metal to increase as the value of the manual mode is increased, hot count ratio with the group of both manual mode 0.5 and 0.4 is the best match. Also, in automatic mode, the ratio of RBRNon-Metal and RBRMetal was 1.135, statistically significant difference was not observed in the manual mode 0.5 and 0.4. Conclusion In the automatic mode of Wide Beam Coefficient in attenuation correction map, it was found that it is over-correction by 13.52%, it was possible to minimize the over-correction by the artifact in 0.5 and 0.4 of manual mode. Further studies should be performed in order to apply to a patient with the help of this and it is considered possible to reduce the over-correction by the metal artifact of an artificial hip joint for Hip-Resurfacing Arthroplasty patients, and to improve the diagnostic performance.

  • PDF

A Germanium Detector Structure PENEL OPE Characteristic Analysis by Computer Simulation (HPGe 검출기의 PENELOPE 전산모사에 의한 특성 분석)

  • Jang, Eunsung;Jang, BoSeok
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.73-77
    • /
    • 2015
  • In order to observe the detailed structure of the detector, it was CT scanned to reproduce the detailed structure of the crystal shapes and traverse layer using the Monte Carlo calculation applying the detector model. The uncertainty of measurement was lowered by adjusting the detector core by the edge effect at a higher energy (400 keV or higher) through the offset of peak efficiency of the gamma ray at low energy. It was confirmed that there was the appropriate matching with spatial dependency using the PENELOPE calculation. That was achieved by adjusting the parameters describing the crystal core and rounding of edge and crystal core.

Experimental Constraint Effect $A_{2}$, Values depending on Displacement according to measuring Positions near Crack Front. (균열선단 근방 변위측정 위치에 따른 구속효과 $A_{2}$)

  • Han, Min-Su;Jang, Seok-Ki;Lee, Don-Chool;Kim, Seong-Jong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.25-30
    • /
    • 2004
  • The magnitude of constraint effect $A_{2}$ values were experimentally estimated using displacement according to measuring positions on the non-linear elastic plastic fracture toughness estimate. For 25.4 mm thickness SS400 steel CT specimen, constraint effect $A_{2}$ values we re dependent on specimen configuration and on measured displacement near crack front. Commonly, Estimating constraint effect $A_{2}$ measuring position for displacement should be existed inside plastic region. Therefore, the ${\delta}_{5}$ method was not reliable for evaluation of constraint effect $A_{2}$ values because measuring position for displacement is in elastic region at crack growth initiation in this paper.

  • PDF

Correlation Between Transient Regime and Steady-State Regime on Creep Crack Growth Behavior of Grade 91 Steel (Grade 91 강의 크리프 균열성장 거동에 대한 천이영역과 정상상태영역의 상관 관계)

  • Park, Jae-Young;Kim, Woo-Gon;Ekaputra, I.M.W.;Kim, Seon-Jin;Kim, Eung-Seon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.12
    • /
    • pp.1257-1263
    • /
    • 2015
  • A correlation between the transient regime and steady state regime on the creep crack growth (CCG) for Grade 91 steel, which is used as the structural material for the Gen-IV reactor systems, was investigated. A series of CCG tests were performed using 1/2" CT specimens under a constant applied load and at a constant temperature of $600^{\circ}C$. The CCG rates for the transient and steady state regimes were obtained in terms of $C^*$ parameter. The transient CCG rate had a close correlation with the steady-state CCG rate, as the slope of the transient CCG data was very similar to that of the steady state data. The transient rate was slower by 5.6 times as compared to the steady state rate. It can be inferred that the steady state CCG rate, which is required for long-time tests, can be predicted from the transient CCG rate obtained from short-time tests.

A Study on the Use of Active Protocol Using the Change of Pitch and Rotation Time in PET/CT (PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구)

  • Jang, Eui Sun;Kwak, In Suk;Park, Sun Myung;Choi, Choon Ki;Lee, Hyuk;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.67-71
    • /
    • 2013
  • Purpose: The Change of CT exposure condition have a effect on image quality and patient exposure dose. In this study, we evaluated effect CT image quality and SUV when CT parameters (Pitch, Rotation time) were changed. Materials and Methods: Discovery Ste (GE, USA) was used as a PET/CT scanner. Using GE QA Phantom and AAPM CT Performance Phantom for evaluate Noise of CT image. Images are acquired by using 24 combinations that four stages pitch (0.562, 0.938, 1.375, 1.75:1) and six stages X-ray tube rotation time (0.5s-1.0s). PET images are acquired using 1994 NEMA PET Phantom ($^{18}F-FDG$ 5.3 kBq/mL, 2.5 min/frame). For noise test, noise are evaluated by standard deviation of each image's CT numbers. And then we used expectation noise according to change of DLP (Dose Length Product) to experimental noise ratio for index of effectiveness. For spatial resolution test, we confirmed that it is possible to identify to 1.0 mm size of the holes at the AAPM CT Performance Phantom. Finally we evaluated each 24 image's SUV. Results: Noise efficiency were 1.00, 1.03, 1.01, 0.96 and 1.00, 1.04, 1.02, 0.97 when pitch changes at the QA Phantom and AAPM Phantom. In case of X-ray tube rotation time changes, 0.99, 1.02, 1.00, 1.00, 0.99, 0.99 and 1.01, 1.01, 0.99, 1.01, 1.01, 1.01 at the QA Phantom and AAPM Phantom. We could identify 1.0 mm size of the holes all 24 images. Also, there were no significant change of SUV and all image's average SUV were 1.1. Conclusion: 1.75:1 pitch is the most effective value at the CT image evaluation according to pitch change and It doesn't affect to the spatial resolution and SUV. However, the change of rotation time doesn't affect anything. So, we recommend to use the effective pitch like 1.75:1 and adequate X-ray tube rotation time according to patient size.

  • PDF

Study of 68Ga Labelled PET/CT Scan Parameters Optimization (68Ga 표지 PET/CT 검사의 최적화된 매개변수에 대한 연구)

  • In Suk Kwak;Hyuk Lee;Si Hwal Kim;Seung Cheol Moon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.111-127
    • /
    • 2023
  • Purpose: Gallium-68 (68Ga) is increasingly used in nuclear medicine imaging for various conditions such as lymphoma and neuroendocrine tumors by labeling tracers like Prostate Specific Membrane Antigen (PSMA) and DOTA-TOC. However, compared to Fluorine-18 (18F) used in conventional nuclear medicine imaging, 68Ga has lower spatial resolution and relatively higher Signal to Background Ratio (SBR). Therefore, this study aimed to investigate the optimized parameters and reconstruction methods for PET/CT imaging using the 68Ga radiotracer through model-based image evaluation. Materials and Methods: Based on clinical images of 68Ga-PSMA PET/CT, a NEMA/IEC 2008 PET phantom model was prepared with a Hot vs Background (H/B) ratio of 10:1. Images were acquired for 9 minutes in list mode using DMIDR (GE, Milwaukee WI, USA). Subsequently, reconstructions were performed for 1 to 8 minutes using OS-EM (Ordered Subset Expectation Maximization) + TOF (Time of Flight) + Sharp IR (VPFX-S), and BSREM (Block Sequential Regularized Expectation Maximization) + TOF + Sharp IR (QCFX-S-400), followed by comparative evaluation. Based on the previous experimental results, images were reconstructed for BSREM + TOF + Sharp IR / 2 minutes (QCFX-S-2min) with varying β-strength values from 100 to 700. The image quality was evaluated using AMIDE (freeware, Ver.1.0.1) and Advanced Workstation (GE, USA). Results: Images reconstructed with QCFX-S-400 showed relatively higher values for SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), count, RC (Recovery Coefficient), and SUV (Standardized Uptake Value) compared to VPFX-S. SNR, CNR, and SUV exhibited the highest values at 2 minutes/bed acquisition time. RC showed the highest values for a 10 mm sphere at 2 minutes/bed acquisition time. For small spheres of 10 mm and 13 mm, an inverse relationship between β-strength increase and count was observed. SNR and CNR peaked at β-strength 400 and then decreased, while SUV and RC exhibited a normal distribution based on sphere size for β-strength values of 400 and above. Conclusion: Based on the experiments, PET/CT imaging using the 68Ga radiotracer yielded the most favorable quantitative and qualitative results with a 2 minutes/bed acquisition time and BSREM reconstruction, particularly when applying β-strength 400. The application of BSREM can enhance accurate quantification and image quality in 68Ga PET/CT imaging, and an optimization process tailored to each institution's imaging objectives appears necessary.

Correlation of Pre-treatment FDG Uptake to Therapeutic Response and Relapse in Patients with Small Cell Lung Cancer (소세포폐암의 치료전 FDG섭취와 치료반응 및 재발과의 연관성)

  • Seo, Young-Soon;Kwon, Seong-Young;Jeong, Shin-Young;Song, Ho-Chun;Min, Jung-Joon;Kim, Kyu-Sik;Kim, Young-Chul;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.538-545
    • /
    • 2007
  • Purpose: We evaluated correlation of $^{18}F$-FDG uptakes, therapeutic response and relapse in pre-treatment $^{18}F$-FDG PET/CT in patients with SCLC. Materials and methods: We included 26 patients with pathologically proven small cell lung cancer. Total 102 lesions (26 lungs, 69 lymph nodes and 8 metastatic lesions) were evaluated. All patients underwent $^{18}F$-FDG PET/CT for staging. The maxSUV was used as a parameter of $^{18}F$-FDG uptake. The patients were divided into responders and non-responders according to response criteria on chest CT scan after 3 cycles of chemotherapy. We compared maxSUV between two groups by using independent t-test. To access correlation with $^{18}F$-FDG uptake and relapse, maxSUV and interval time to relapse was analyzed by correlation analysis. The cutoff value of maxSUV was evaluated by ROC curve. Results: Twelve-one patients (81%) were responders and five patients were non-responders on follow-up chest CT scan. The mean maxSUV of main lung lesions in responders and non-responders were $14.15{\pm}3.72$ and $9.17{\pm}2.15$, respectively. The maxSUV in the responders was significantly lower than that in non-responders (p<0.05). According to ROC curve, point of cut that predicts therapeutic response was 8.98 with 100% sensitivity and 57% specificity. The correlation analysis between $^{18}F$-FDG uptakes and interval time to relapse showed a significant negative correlation (p<0.05, r=-0.757). Conclusion: The pre-treatment $^{18}F$-FDG uptake of responders was significantly lower than that of non-responders. Patients with high $^{18}F$-FDG uptake in pre-treatment $^{18}F$-FDG PET/CT relapse earlier.

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

Crack Growth Instability for Ductile Material Using the Compact Tension Specimen (컴팩트 인장 시편을 이용한 연성 재료의 불안정 균열 성장에 관한 연구)

  • 이홍서;김희송
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.928-937
    • /
    • 1989
  • Applicability of $T_{\delta}$ proposed by Shin et al as an instability parameter for ductile material is investigated, Both general fracture test and instability fracture test are performed using compact tension specimens of structural alloy steel(SCM4), The values of ( $T_{\delta}$)$_{app}$(applied tearing modules) estimated from the real load vs. crack growth curve measured from experiments are compared with those estimated from the limit load vs. crack growth curve. The results are:(1) the $T_{\delta}$ parameter may be used as a crack instability parameter:(2) the use of ( $T_{\delta}$)$_{app}$ estimated from the load-crack growth curve, proposed in this study is reasonably justified.ified.d.

Intelligent Shape Analysis Using Multi-sensory Interaction (다중 감각 인터랙션을 이용한 지능형 형상 분석)

  • Kim, Jeong-Sik;Kim, Hyun-Joong;Choi, Soo-Mi
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10a
    • /
    • pp.139-142
    • /
    • 2006
  • 본 논문에서는 햅틱 피드백과 스테레오 비쥬얼 큐를 혼합한 다중 감각 기반의 지능형 3차원 형상 분석 방법을 소개한다. 지능형 형상 분석 방법은 3차원 모델의 구조에 대한 보다 상세한 정보를 제공한다. 특히 의료 분야에 사용될 경우 전문가의 개입을 최소화하여 질병 진단 및 치료 등에 사용될 수 있다. 본 연구에서는, MRI나 CT 영상으로부터 생성된 3차원 매개변수형 모델을 이용하여 유사 모델 집단을 대표하는 통계 형상을 구축한 후, SVM (Support Vector Machine) 학습 알고리즘을 이용하여 두 집단간 형상 차이를 분석한다. 3차원 형상에 대한 신속한 시각적 이해와 직관적 조작감은 물체 표면의 형상 변화를 분석하는데 효과적으로 사용될 수 있다. 본 논문에서는 물체 조작 및 관찰 등의 작업을 수행할 때, 햅틱 피드백과 스테레오 비쥬얼 큐를 혼합한 인터랙션 기법을 사용하여 공간감과 깊이감을 향상시켜 형상 분석 결과를 효과적으로 분석한다. 본 연구에서는 해마, 관상 동맥, 뇌와 같은 인체 장기를 실험 데이터로 사용하여 제안한 SVM 기반의 분석 방법과 인터랙션 환경의 성능을 평가한다. 본 연구에서 구현한 SVM 기반 이진 분류기는 두 집단간 형상 차이를 효과적으로 분석하며, 또한 다중 감각 인터랙션은 사용자가 분석 결과를 관찰하고 카메라 및 형상을 효율적으로 조작하는 데 도움을 준다.

  • PDF