• Title/Summary/Keyword: CsV

Search Result 361, Processing Time 0.027 seconds

Impurity analysis of Ta films using secondary ion mass spectrometry (이차이온 질량분석기를 이용한 탄탈 박막내의 불순물 분석)

  • ;;Minoru Isshiki
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.1
    • /
    • pp.22-28
    • /
    • 2004
  • Ta films were deposited on Si (100) substrates at zero substrate bias voltage and a substrate bias voltage of -125 V ($V_{s}$ = -125 V) using a non-mass separated ion beam deposition system. To investigate the effect of the negative substrate bias voltage on the impurity concentration in the Ta films, secondary ion mass spectrometry (SIMS) was used to determine impurities in the Ta films. By the SIMS depth profiles with $Cs^{+}$ cluster ion beam, high intensities of O, C and Si were clearly found in the Ta film at $V_{s}$ = 0 V, whereas these impurities remarkably decreased in the Ta film at $V_{s}$ = -125 V. Furthermore, from the SIMS result with $Cs^{+}$ and $O_2^{+}$ ion beams, it was found that applying the negative substrate bias voltage could affect individual impurity contents in the Ta films during the deposition. Discussions concerning the effect of the negative substrate bias voltage on the impurity concentration of Ta films will be described in details.

The signal property and structure design of CsI:Na/a-Se for diagnostic x-ray imaging (진단 X선 영상을 위한 CsI:Na/a-Se 구조설계 및 신호특성)

  • Park, Ji-Koon;Heo, Ye-Ji;Park, Jeong-Eun;Park, Sang-Jin;Kim, Hyun-Hee;No, Ci-Chul;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.35-38
    • /
    • 2009
  • Flat-panel x-ray detectors using a phosphor and photoconductor material have been used for application in various medical modalities. In this study, the monte carlo simulation, optical and x-ray response characteristics were investigated in the conversion structure obtained by a columnar CsI:Na scintillation layer with a photosensitive amorphous selenium layer. Firstly, from the measurement of luminescent spectrum of CsI:Na and absorption spectrum of a-Se layer, the signal conversion characteristics are analysed. And also, the x-ray sensitivity is measured and compared with conventional a-Se($500{\mu}m$) as a function of electrical field. From the experimental result, the x-ray sensitivities of the CsI:Na($180{\mu}m$)/a-Se($30{\mu}m$) detector and the a-Se($500{\mu}m$) detector were $7.31nC/mR-cm^{2}$ and $3.95nC/mR-cm^{2}$at an electric field of $10V/{\mu}m$, respectively.

  • PDF

Kaolin 토양에 대한 동전기적 제염기술 적용 연구

  • 원휘준;안병길;김계남;이철용;이병직;오원진
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.802-807
    • /
    • 1998
  • Cs$^{+}$ 이온으로 오염된 kaolin 토양에 대한 동전기적 토양제염 연구를 수행하였다. 실험실 규모의 제염장치를 제작하여 계의 pH, 전류 및 전압 변화를 측정하였으며 전압 변화에 따른 전기삼투 흐름속도의 변화와 산 전선의 이동속도 변화를 조사하였다. 일정시간에서, Cs$^{+}$ 이온의 제거량은 계에 걸어준 전압에 비례하여 증가하였고 실험으로부터 구한 본 계의 electroosmotic permeability coefficient (K$_{e}$)는 4.27 x $10^{-6}$ $\textrm{cm}^2$/V.S 이다.

  • PDF

Anti-Proliferative Effect of Polysaccharides from Salicornia herbacea on Induction of G2/M Arrest and Apoptosis in Human Colon Cancer Cells

  • Ryu, Deok-Seon;Kim, Seon-Hee;Lee, Dong-Seok
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.11
    • /
    • pp.1482-1489
    • /
    • 2009
  • In this study, we investigated the anti-proliferative effect of polysaccharides from Salicornia herbacea on HT-29 human colon cancer cells. Crude polysaccharides from S. herbacea (CS) were prepared by extraction with hot steam water, and fine polysaccharides from S. herbacea (PS) were obtained through further size exclusion chromatography. The anti-proliferative effect of CS and PS were measured using the MTS assay, apoptosis analysis, cell cycle analysis, and RT-PCR. HT-29 cells were treated with CS or PS at different dosages (0.5, 1, 2, 4 mg $ml^{-1}$) for 24 or 48 h. CS and PS inhibited proliferation and stimulated apoptosis of cells in a dose-dependent manner. Flow cytometric analysis after Annexin V-FITC and PI staining revealed that treatment with CS or PS increased total apoptotic death of cells to 24.99% or 91.59%, respectively, in comparison with the control (13.51 %). PS increased early apoptotic death substantially - up to 12 times more than the control. Treatment with CS or PS resulted in a concentration-dependent increase of the G2/M cell population of the cell cycle as determined by flow cytometry. G2/M arrest was induced significantly with the highest concentration (4 mg $ml^{-1}$) of PS. RT-PCR was performed to study the correlation between G2/M arrest and transcription of cell cycle control genes. The anti-proliferative activity of CS and PS was accompanied by inhibition of cyclin B1, and Cdc 2 mRNA. Moreover, both CS and PS induced expression of the p53 tumor suppressor gene and the Cdk inhibitor p21. These results suggest that polysaccharides from S. herbacea have anti-cancer activity in human colon cancer cells.

A Study on Castability and Roughness of the Casts Using Non-precious Alloys (비귀금속 합금을 이용한 주조체의 주조성과 Roughness에 관한 연구)

  • Kim, Jang-Ju
    • Journal of Technologic Dentistry
    • /
    • v.20 no.1
    • /
    • pp.5-11
    • /
    • 1998
  • The purpose of this study is to evaluate the castability and surface roughness of the casts using Non-percious alloys. For samples of 25 wax patterns, it is made from eight layers of sheet wax, arranged in the escalating layers. After fabricated wax patterns, using 5 kinds of Ni-Cr alloys is casted, and the casts are sandblasted. To castability, magnifier is used and values of surface roughness of the casts is measured with profilometer(tracing length 1.75mm, cutoff value 0.25mm) The results are as follows : 1. The castanbility of alloys, in case of C alloys, showed with $8.0{\pm}0.0000$, and in case of CS alloys and N alloys showed equal with $7.8{\pm}0.4472$, respectively. T alloys and V alloys showed equal with $7.2{\pm}0.4472$, respectively. 2. The values of surface roughness of the casts are decreased more T alloys than in case of order alloys, and in order, increased in case of CS alloys, C alloys, V alloys, N alloys, respectively.

  • PDF

Electrogravimetric and Electrochemical Ac Response of Polypyrrole Films

  • Yang, Haesik;Lee, Hochun;Kwak, Juhyoun
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.663-668
    • /
    • 1995
  • Ion transport of a polypyrrole/chloride (PPy/Cl) film and a polypyrrole/poly(styenesulfonate) (PPy/PSS) film as a function of applied dc potential was investigated by employing electrogravimetric impedance technique and electrochemical impedance technique. The cation and anion contribution to the whole charge capacitance and the diffusion coefficients of cation and anion in a PPy/PSS film were calculated by fitting the electrogravimetric impedance data with proposed model circuit. The diffusion coefficients of $Na^+$ in a 1 M $NaClO_4$ solution are over 1 order of magnitude larger than those of $ClO{_4}^-$, and $ClO{_4}^-$ contribution to charge compensation decreases as dc potential lowers. The charge compensation of a PPy/Cl film ir a 1 M CsCl solution is carried out largely by $Cl^-$ at 0.2 V vs. Ag/AgCl and by $Cs^+$ as well as $Cl^-$ at -0.4 V.

  • PDF

Potentiometric Characteristics of Ion-Selective Electrodes Based on Upper-Rim Calix[4]crown Neutral Carrier

  • 강유라;오현준;이경문;차근식;남학현;백경수;임혜재
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.2
    • /
    • pp.207-211
    • /
    • 1998
  • Potentiometric characteristics of DOS plasticized PVC-based membranes containing upper-rim calix[4]crown neutral carrier to various metal cations and protonated alkylamines have been examined. Although the calix[4]crown-based membrane electrodes exhibited substantial emf responses to alkali and alkaline earth metal cations, their high detection limits (- log[Cs+]=4.5) and sub-Nernstian response slopes (48 mV/pCs+) to the most selective cation, cesium, indicate that the metal cation complexing ability of calix[4]crown is much weaker than that of macrocyclic crown ethers. However, the calix[4]crown-based membrane electrodes exhibited near-Nernstian response slopes (56 mV/decade for hexylNH3+) with low detection limits (log[hexylNH3+]= - 6.7) to most alkylammonium ions compared to those of blank (DOS plasticized PVC membrane with no ionophore) or crown ether-based membranes. While the selectivity patterns of blank and crown ether-based membranes are determined primarily by the lipophilicity of alkylammonium ions, the membranes doped with calix[4]crown ionophore could effectively discriminate the steric shapes of nonpolar alkyl groups of alkylammonium ions.

The Possible Modification of the Half Life of the $^{133}Cs$ nucleus in the Finite Space (유한한 공간에서 $^{133}Cs$ 원자핵 반감기의 변화에 대한 연구)

  • Jeong, Moon-Taeg;Dong, Kyung-Rae
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.213-218
    • /
    • 2009
  • A theoretical investigation has been carried out on how the energy width of the excited state of the nuclei is modulated when the $\gamma$-ray source is placed between two gold plates, at the center of the gold cylinder or the sphere. The width of the 81-keV level of $^{133}Cs$ is shown to become narrower by 3.7% at 4.2 K by reabsorption of $\gamma$ rays scattered backward from the parallel plates which are made of a 0.05-cm-thick, 3-cm-radius gold plates and separated from each other by 1.0 mm. With a 0.05-cm-thick, 5-cm-long, 1.0-mm-radius gold cylinder, we found that a width became narrower by 6.5%. In addition, when the nuclei is located in a spherical reflector of 1.0 mm in radius made of gold with a thickness of 0.5 mm. the level width is reduced by about 18.2% at a temperature 4.2 K. The results of this study indicates that the life-time of energy level was prolonged.

  • PDF