• 제목/요약/키워드: CsI(Tl)

검색결과 66건 처리시간 0.031초

방사능 수치 오염 지도 작성을 위한 방사선 계측 시스템 연구 (Study of Radiation Mapping System for Water Contamination in Water System)

  • 나원경;김한수;연제원;이레나;하장호
    • 방사선산업학회지
    • /
    • 제5권2호
    • /
    • pp.185-189
    • /
    • 2011
  • As nuclear industry has been developed, a various types of radiological contamination has occurred. After 9.11 terror in U.S.A., it has been concerned that terrorists' active area has been enlarged to use nuclear or radioactive substance. Recently, the most powerful earth-quake stroke, which triggered a massive tsunami in Japan and then Fukushima nuclear power plant reactor has suffered from a serious accident in history. The Fukushima reactor accident has occurred an anxiety of radiation leaks and about 170,000 people have been evacuated from the accidental area near the nuclear power plant. For these reasons, a social chaos can be occurred if radiological contamination occurs to the supply system for the drinking water. As such, the establishment of the radiation monitoring system for the city main water system is compelling for the national security. In this study, a feasibility test of radiation monitoring system which consists of unified hybrid-type radiation detectors was experimented for multi detection system by using gamma-ray imaging. The hybrid-type radiation sensors were fabricated with CsI(Tl) scintillators and photodiodes. A preamplifier and amplifier was also fabricated and assembled with the sensor in the shielding case. For the preliminary test of detection of radiological contamination in the river, multi CsI(Tl)-PIN photodiode radiation detectors and $^{137}Cs$ gamma-ray source were used. The DAQ was done by Linux based ROOT program and NI DAQ system with Labview program. The simulated contamination was assumed to be occurred at Gapcheon river in Daejeon city. Multi CsI(Tl)-PIN photodiode radiation detectors were positioned at the Gapcheon river side. Assuming that the radiological contaminations flows in the river the $^{137}Cs$ gamma-ray source has been moved and then, the contamination region was reconstructed.

섬광체 옆 표면처리가 소형 감마카메라 영상에 미치는 효과 (Effects of Scintillation Crystal Surface Treatments on Small Gamma Camera Imaging)

  • 김종호;최용;김준영;오차환;김상은;최연성;이경한;주관식;김병태
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권6호
    • /
    • pp.515-521
    • /
    • 1999
  • 감마카메라에서 섬광체는 감마선을 검출하여 카메라의 영상 특성을 결정하는 주요한 센서역할을 한다. 이 연구에서는 감마카메라 제작시에 고려되어야 하는 섬광체의 옆표면처리가 감마카메라영상에 미치는 영향에 대하여 고찰하였다. 섬광체는 크기가 20mm (직경 $\times$10mm(두께)인 NaI(TI) 와 CsI(TI)를 설정하여 옆표면처리를 반사체와 흡수체로 하였다 . 선정한 4개의 섬광체에서 감마선에 의해 발생한 섬광이 광전자증배관의 광음극에 도달할 때 까지의 광학적 특성을 몬테카를로(Monte Carlo) 시뮬레이션 방법을 이용하여 고찰하였다. 또한 이 네 개의 섬광체를 위치민감형 광전자증배관에 광학적으로 결합하여 Tc-99m 140 keV 에 대한 민감도와 플러드 영상, 에너지 분해능 그리고 위치분해능을 측정하였다. 시뮬레이션 결과, NAI(TI)-반사체가 가장 우수한 민감도를 보인 것으로 계산되었으며, 감마카메라를 이용하여 획득한 플러드영상에서 민감도는 NAI(TI)-반사체 2920cps/$\mu$Ci, NaI(TI)-흡수체2322 cps/$\mu$Ci, CsI(TI) 반사체 1754 cps/$\mu$Ci, CsI(TI)/흡수체 1401 cps/$\mu$Ci로 축정되었다. 내인성 위치분해능은 NaI(TI)-반사체 5.17mm, , NaI(TI)-흡수체 4.54mm, CsI(TI)-반사체 6.99m, CsI(TI)-흡수체 6.31 mm FWHM의 결과를 나타냈다. Tc -99m 140 keV에 대한 에너지분해능은 NaI(TI)-반사체 12.5%, NAI(TI) -흡수체 23.5%, CSI(TI)-반사체 20.5%, CsI(TI) -흡수체 33.3% FWHM으로 측정되었다. 이 연구에서는 감마카메라에서 사용되는 섬광체의 옆표면처리가 카메라의 주요특성에 직접적인 영향을 미친다는 것을 시뮬레이션과 실체 측정방법으로 고찰할 수 있었으며, 두 가지 방법이 일치된 결과를 보여주었다. 결론적으로 섬광체와 광전자증배관 그리고 Tc-99m 선원을 이용하여 영상획득을 목적으로 하는 감마카메라 제작에서는 NAaI(TI) 섬광체가 CSI(TI) 보다 적합하며, 해상력을 고려할 경우에는 섬광체 옆표면을 흡수체로 민감도를 고려할 경우에는 반사체로 선택하여 처리해야 함을 확인하였다.

  • PDF

Calibration of cylindrical NaI(Tl) gamma-ray detector intended for truncated conical radioactive source

  • Badawi, Mohamed S.;Thabet, Abouzeid A.
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1421-1430
    • /
    • 2022
  • The computation of the solid angle and the detector efficiency is considering to be one of the most important factors during the measuring process for the radioactivity, especially the cylindrical γ-ray NaI(Tl) detectors nowadays have applications in several fields such as industry, hazardous for health, the gamma-ray radiation detectors grow to be the main essential instruments in radiation protection sector. In the present work, a generic numerical simulation method (NSM) for calculating the efficiency of the γ-ray spectrometry setup is established. The formulas are suitable for any type of source-to-detector shape and can be valuable to determine the full-energy peak and the total efficiencies and P/T ratio of cylindrical γ-ray NaI(Tl) detector setup concerning the truncated conical radioactive source. This methodology is based on estimate the path length of γ-ray radiation inside the detector active medium, inside the source itself, and the self-attenuation correction factors, which typically use to correct the sample attenuation of the original geometry source. The calculations can be completed in general by using extra reasonable and complicate analytical and numerical techniques than the standard models; especially the effective solid angle, and the detector efficiency have to be calculated in case of the truncated conical radioactive source studied condition. Moreover, the (NSM) can be used for the straight calculations of the γ-ray detector efficiency after the computation of improvement that need in the case of γ-γ coincidence summing (CS). The (NSM) confirmation of the development created by the efficiency transfer method has been achieved by comparing the results of the measuring truncated conical radioactive source with certified nuclide activities with the γ-ray NaI(Tl) detector, and a good agreement was obtained after corrections of (CS). The methodology can be unlimited to find the theoretical efficiencies and modifications equivalent to any geometry by essential sufficiently the physical selective considered situation.

방사선 분포측정용 CsI(Tl) 검출기 설계 및 신호처리에 관한 연구 (The Study of CsI(Tl) Scintillation Detector Design and Signal Processing for the Measurement of the Radiation Distribution)

  • 황영관;이남호;김종열;정상훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.778-779
    • /
    • 2016
  • 본 논문에서는 공간상에 분포된 방사선원에 대해 화소단위로 방사선 신호를 탐지하기 위한 섬광 검출기를 설계하고, 탐지신호를 취득하기 위한 모듈을 설계하여 방사선 영상화를 위한 연구를 수행하였다. 방사선 분포측정을 위해 적용한 검출기는 CsI(Tl) 섬광체와 결합효율이 높은 수광센서로 구성하였으며, 수광센서를 통해 획득된 신호를 처리하기 위해 펄스 신호를 증폭, 성형 한 후 임계치를 기준으로 펄스를 계수하기 위한 장치를 구현하였다. 제작된 검출기의 성능을 검증하기 위해 감마선 교정시설을 이용하여 검출기에 대한 성능 시험을 수행하고 그 결과를 분석하였다. 본 논문의 결과는 제작된 검출기에 방향성을 부여하기 위한 차폐체 및 조사부를 적용한 후 방향을 이동시켜 개별적인 영역의 값을 2차원 적으로 나타냄으로써 선원의 분포측정을 위한 기초자료로 활용될 것이다.

  • PDF

섬광체 옆표면처리가 감마카메라 영상에 미치는 효과 (Effects of Scintillation Crystal Surface Treatments on Gamma Camera Imaging)

  • 김종호;최용;오차환;김준영;이만영;김상은;최연성;주관식;김병태
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.303-304
    • /
    • 1998
  • We investigated the effects of scintillation crystal surface treatment on gamma camera imaging. The NaI(Tl) and CsI(Tl) (20 mm (dia.) $\times10mm$ (thick) plate) scintillators were chosen for this study. Two different surface treatments, white and black reflectors, were applied to NaI(Tl) and CsI(Tl). The optical properties of generated scintillation light were evaluated using Monte Carlo simulation and postion sensitive photo multiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of a gamma camera system with the scintillators coupled to a PSPMT. Based on the results, we concluded that the careful consideration of surface treatments of the scintillator was necessary in order to develop the gamma camera having good sensitivity and spatial resolution.

  • PDF