• Title/Summary/Keyword: Cryogenic fluid

Search Result 117, Processing Time 0.026 seconds

Conceptual design of cryomodules for RAON

  • Kim, Y.;Lee, M.K.;Kim, W.K.;Jang, H.M.;Choi, C.J.;Jo, Y.W.;Kim, H.J.;Jeon, D.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.3
    • /
    • pp.15-20
    • /
    • 2014
  • The heavy ion accelerator that will be built in Daejeon, Korea utilizes superconducting cavities operating in 2 K. The cavities are QWR (quarter wave resonator), HWR (half wave resonator), SSR1 (sing spoke resonator1) and SSR2. The main role of the cryomodule is supplying thermal insulation for cryogenic operation of the cavities and maintaining cavities' alignment. Thermal and structural consideration such as thermal load by heat leak and heat generation, cryogenic fluid management, thermal contraction, and so on. This paper describes detailed design considerations and current results have being done including thermal load estimation, cryogenic flow piping, pressure relief system, and so on.

CFD Simulation of thermoacoustic oscillations in liquid helium cryogenic system

  • wang, xianjin;niu, xiaofei;bai, feng;zhang, junhui;chen, shuping
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Thermoacoustic oscillations (TAOs) could be often observed in liquid helium cryogenic system especially in half-open tubes. These tubes have closed warm end (300K) and open cold end (usually 4.4K). This phenomenon significantly induces additional heat load to cryogenic system and other undesirable effects. This work focuses on using computational fluid dynamics (CFD) method to study TAOs in liquid helium. The calculated physical model, numerical scheme and algorithm, and wall boundary conditions were introduced. The simulation results of onset process of thermoacoustic oscillations were presented and analyzed. In addition, other important characteristics including phase relation and frequency were studied. Moreover, comparisons between experiments and the CFD simulations were made, which demonstrated thevalidity of CFD simulation. CFD simulation can give us a better understanding of onset mechanism of TAOs and nonlinear characteristics in liquid helium cryogenic system.

Study of thermoacoustic oscillations in half-open tubes for saturated superfluid helium

  • Wang, Xianjin;Niu, Xiaofei;Bai, Feng;Zhang, Junhui;Chen, Shuping
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.68-73
    • /
    • 2022
  • Thermoacoustic oscillations (TAOs) are spontaneous pressure oscillations frequently seen in hydrogen or helium cryogenic systems. Half-open tubes connected to cryogenic fluid with a closed room temperature end have a high potential for oscillation generation. Thermoacoustic oscillations will result in significant pressure fluctuations and additional heat load, endangering the security and stability of the cryogenic system. The goal of this paper is to investigate TAOs in superfluid helium using both theoretical and experimental methods. Five half-open tubes with varied typical inner diameters inserted into superfluid helium were installed in a test cryostat. The onset characteristics of thermoacoustic oscillations were presented and studied. The effect of temperature profile was discussed. Finally, a simple eliminating method was introduced.

Experiemtnal Tests of Cryogenic Liuid Spill on a Plate (극저온 유체 유출현상에 관한 연구)

  • Ryu, Yong Hee;Hwang, Yun Ji;Lee, Yun Han;Kim, Kwang Seok;Lee, Jae Hun;Sim, Hee Jun
    • Plant Journal
    • /
    • v.16 no.3
    • /
    • pp.42-46
    • /
    • 2020
  • In the large LNG process in FLNG or FSRU, sudden temperature drops of the steel in the event of LNG leaks may cause brittle fracture of the structure. In this paper, we investigate the principle and process of forming a cryogenic fluid on a steel plate through a cryogenic spillage experiment, and analyze the correlation of the temperature distribution of the steel plate according to the distance from the nozzle and exposure time. Two types of cryogenic fluids were used: LN2 and LNG. The cyogenic liquid was released on the steel plate at 1.6L/min for LN2 and 1.5L/min for LNG. For the steel, DH was used and the temperature was measured at 10 points in total. The Leidenfrost effect was observed on the steel plate, and the temperature distribution of the steel was varied according the flow path and the heat of evaporation of the fluid.

Development Test of Pyro-Valve for Cryogenic Gaseous Helium in Pressurization System of Launch Vehicle (발사체 가압시스템용 극저온 헬륨가스 파이로밸브 개발시험)

  • Chung, Yong-Gahp;Han, Sang-Yeop;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.293-297
    • /
    • 2009
  • Valves, which are used to supply or block the flow of cryogenic pressurant in the pressurization system of liquid-propellant propulsion system in a launch vehicle, are pneumo-actuated valve, solenoid valve, pyro-valve, etc. Both pneumo-actuated valve and solenoid valve have more complex structure and are heavier than pyro-valve. For this study, a couple of pyro-valves, which are applicable to cryogenic and high-pressure fluid (cryogenic gaseous helium), have a simple structure, and are comparably light, are designed, manufactured, and tested (proof-pressure/leakage tests, performance test, vibration test, helium supply tests).

  • PDF

A development of linear compressor for a cryogenic stirling cooler (극저온 스터링 냉동기용 선형 압축기 개발)

  • 지상우;임경화;강희석;강경태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.731-734
    • /
    • 2001
  • A cryogenic stirling cooler is currently under development at Korea Institute of Industrial Technology(KITECH). Cryocooler has many kinds of types. The stirling cooler is the most appropriate one for under 80K with the trait of long life cycle and small size. The stirling cooler uses helium as a working fluid. Helium is pressurized by the linear compressor which is driver by linear motor. In this paper, the change of pressure and volume is studied by the isothermal analysis method. It is necessary to investigate the optimized pressure to meets the highest COP. The compressor's piston and expender's displacer interact according to the working fluid's pressure level and the phase difference. This paper presents the relation between the initial pressure and the work of cryocooler. By that results, we can predict the performance of linear compressor.

  • PDF

Tank Pressure Control of PWM Sol V/V for Thrust Control of Launch Vehicle (발사체 추력제어 안정성을 위한 PWM 솔밸브의 탱크압력제어)

  • Lee, Joong-Youp;Hong, Moon-Geun;Han, Sang-Yeop;Kim, Young-Mog
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.565-568
    • /
    • 2006
  • This paper achieved dynamic characteristics with test to use solenoid valve for flight model that have present. Designed pressure control virtual system which PWM solenoid valve to use test result. Examination compared solenoid valve dynamic characteristics in atmosphere and cryogenic fluid and presented technique and valuation method that measured upstream and down stream pressure of solenoid valve, as well as, temperature, excitation voltage etc. These test results could confirm solenoid valve response time and maximum using frequency characteristic at use in atmosphere and cryogenic temperature and this derived design variables pressure control system from those bases.

  • PDF

Application of Foil Gas Bearing to the 38kW, 100000 RPM Class High Speed Motor (38kW, 100000 RPM 고속모터에 대한 포일 가스 베어링 응용 개발)

  • Kim, Kyeong-Su;Park, Ki-Cheol;Kim, Seung-Woo;Lee, In
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.127-131
    • /
    • 2003
  • Foil gas bearing is a noncontact bearing operated by coupled interaction between hydrodynamic pressure of viscous fluid and elastic deformation of foil structure. It has valuable advantages, such as low power loss, long life, oilless environment and low vibration, over conventional bearings for the high speed applications. A high speed BLDC motor adopting the foil bearing has been developed. It is designed to have 38㎾ power at 100,000 RPM for a cryogenic cooler whose operating fluid is neon. In this paper, structural development details especially for the foil gas bearing and rotordynamics are presented.

  • PDF

Experimental Investigation on the Freezing Condition of Printed Circuit Heat Exchanger for Cryogenic Liquid Hydrogen Vaporizer (극저온 액체수소 기화기용 인쇄기판 열교환기의 동결 조건에 관한 실험적 연구)

  • WOOKYOUNG KIM;BOKYEM KIM;SANGHO SOHN;KONG HOON LEE;JUNGCHUL KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.2
    • /
    • pp.240-248
    • /
    • 2024
  • The purpose of this study is to investigate the freezing phenomena in printed circuit heat exchanger (PCHE) for cryogenic liquid hydrogen vaporizer. Local freezing phenomena in hot channels should be avoided in designing PCHE for cryogenic liquid hydrogen vaporizer. Hence, the flow and thermal characteristics of PCHE is experimentally investigated to figure out the conditions under when freezing occurs. To conduct lab-scale PCHE experiment, liquid nitrogen is used as a working fluid in cold channels instead of using liquid hydrogen. Glycol water is used as a working fluid in hot channels. Based on the experimental data, ratio between mass flow rates of cold channels and that of hot channels is proposed as contour map to avoid the freezing phenomena in PCHE.

Analysis of Propellant Feeding Sub-Systems for Liquid Rocket (SINDA/FLUINT를 활용한 발사체 추진기관 공급계 해석)

  • Cho, Nam-Kyung;Jeong, Yong-Gahp;Han, Sang-Yeop;Kim, Young-Mog
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.241-244
    • /
    • 2006
  • The analysis of propellant feeding sub-system is performed using a commercial code SINDA/FLUINT, the comprehensive finite-difference, one-dimensional, lumped parameter tool. With the code, cryogenic helium supply system, liquid oxygen supply system, helium injection cooling system are evaluated. The code gave satisfactory estimation scheme for propulsion system characterized by cryogenic temperature and high pressure, two phase flow. This paper focuses on presenting calculation scheme of propulsion sub-system using one-dimensional code like SINDA/FLUINT.

  • PDF