• 제목/요약/키워드: Cryogenic Temperature

검색결과 635건 처리시간 0.026초

인입 전류에 따른 실리콘(Silicon) 다이오드의 극저온 p-n 접합의 문턱 전압 특성 (Properties of p-n junction threshold voltage of Silicon diode by transport current in cryogenic temperature)

  • 이안수;이승제;이응로;고태국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.864-867
    • /
    • 2003
  • Since the development of semiconductors, various related research has been conducted. During research, silicon diodes have been commonly used because of their simplicity and low cost in the manufacturing process. This research deals with p-n junction threshold voltages from silicon diodes due to transport current at a cryogenic temperature. At a cryogenic temperature(77K) we could get minimum current which junction threshold voltage becomes constant. This is experimented on GPIB communication and it consist of programmable current source, multimeter which gauge the threshold voltage in a very low temperature caused by transport current from 5nA to 1mA and $LN_2$(77K) for coolant. This experiment is programmed all process using Measurement studio(Lab window) tool.

  • PDF

Survival of the Insulator under the electrical stress condition at cryogenic temperature

  • Baek, Seung-Myeong;Kim, Sang-Hyun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.10-14
    • /
    • 2013
  • We have clearly investigated with respect to the survival of the insulator at cryogenic temperature under the electrical stress. The breakdown and voltage-time characteristics of turn-to-turn models for point contact geometry and surface contact geometry using copper multi wrapped with polyimide film for an HTS transformer were investigated under AC and impulse voltage at 77 K. Polyimide film (Kapton) 0.025 mm thick is used for multi wrapping of the electrode. As expected, the breakdown voltages for the surface contact geometry are lower than that of the point contact geometry, because the contact area of the surface contact geometry is lager than that of the point contact geometry. The time to breakdown t50 decreases as the applied voltage is increased, and the lifetime indices increase slightly as the number of layers is increased. The electric field amplitude at the position where breakdown occurs is about 80 % of the maximum electric field value. The relationship between survival probability and the electrical stress at cryogenic temperature was evident.

Insulation Characteristics for a Conduction-Cooled HTS SMES

  • Cheon H.G.;Baek S.M.;Seong K.C.;Kim H.J;Kim S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권2호
    • /
    • pp.39-43
    • /
    • 2005
  • Toward the practical applications, on operation of conduction-cooled HTS SMES at temperatures well below 77 K should be investigated, in order to take advantage of a greater critical current density of HTS and considerably reduce the size and weight of the system. Recently, research and development concerning application of the conduction-cooled HTS SMES that is easily movement are actively progressing in Korea. Electrical insulation under cryogenic temperature is a key and an important element in the application of this apparatus. However, the behaviors of insulators for cryogenic conditions in air or vacuum are virtually unknown. Therefore, this work focuses on the breakdown and flashover phenomenology of dielectrics exposed in vacuum for temperatures ranging from room temperature to cryogenic temperature. Firstly, we summary the insulation factors of the magnet for HTS SMES. And a surface flashover as well as volume breakdown in air and vacuum has been investigated with two kind insulators. Finally, we will discuss applications for the HTS SMES including aging studies on model coils exposed in vacuum at cryogenic temperature.

Development of a PLD heater for continuous deposition and growth of superconducting layer

  • Jeongtae Kim;Insung Park;Gwantae Kim;Taekyu Kim;Hongsoo Ha
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권2호
    • /
    • pp.14-18
    • /
    • 2023
  • Superconducting layers deposited on the metal substrate using the pulsed laser deposition process (PLD) play a crucial role in exploring new applications of superconducting wires and enhancing the performance of superconducting devices. In order to improve the superconducting property and increase the throughput of superconducting wire fabricated by pulsed laser deposition, high temperature heating device is needed that provides high temperature stability and strong durability in high oxygen partial pressure environments while minimizing performance degradation caused by surface contamination. In this study, new heating device have been developed for PLD process that deposit and growth the superconducting material continuously on substrate using reel-to-reel transportation apparatus. New heating device is designed and fabricated using iron-chromium-aluminum wire and alumina tube as a heating element and sheath materials, respectively. Heating temperature of the heater was reached over 850 ℃ under 700 mTorr of oxygen partial pressure and is kept for 5 hours. The experimental results confirm the effectiveness of the developed heating device system in maintaining a stable and consistent temperature in PLD. These research findings make significant contributions to the exploration of new applications for superconducting materials and the enhancement of superconducting device performance.

Gas-lift를 이용한 극저온 추진제의 재순환 성능에 대한 실험 (Experimental Study on Cryogenic Propellant Circulation using Gas-lift)

  • 권오성;이중엽;정용갑
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.551-554
    • /
    • 2006
  • Inhibition of propellant temperature rising in liquid propulsion rocket using cryogenic fluid as a propellant is very important. Especially propellant temperature rising during stand-by after filling and pre-pressurization can bring into cavitation in turbo-pump. One of the method preventing propellant temperature rising in cryogenic feeding system is recirculating propellant through the loop composed of propellant tank, feed pipe, and recirculation pipe. The circulation of propellant is promoted through gas-lift effect by gas injection to lower position of recirculation pipe. In this experiment liquid oxygen and gas helium is used as propellant and injection gas. Under atmospheric and pressurized tank ullage condition, helium injection flow-rate is varied to observe the variation of recirculating flow-rate and propellant temperature in the feed pipe. There is appropriate helium injection flow-rate for gas-lift recirculation system.

  • PDF

줄-톰슨 극저온 냉각기용 벨로우즈의 변형해석 (Deformation Analysis of Self-regulating Bellows in Joule-Thomson Cryocooler)

  • 이상은;이태원
    • 한국정밀공학회지
    • /
    • 제25권4호
    • /
    • pp.100-107
    • /
    • 2008
  • Bellows is an important component in Joule-Thomson cryocooler, which minimize the excessive flow of the cryogenic gas. The bellows is made of Monel 400 and its geometry is an axial symmetric shell. During cool-down process, the pressure and volume within bellows must be satisfied with Benedict-Webb-Rubin state equation. Moreover, Poisson's ratio of Monel 400 is nearly constants, but its Young's modulus varies for a drop in temperature. Under these conditions, bellows contracts in the axial direction like a spring. To evaluate deformation of bellows at cryogenic temperature, the numerical calculation of the volume within bellows and finite element analysis are iteratively used in this research. the numerical results show that deformation of the bellows is approximately linear for change of temperature.

154 kV급 고온초전도 변압기의 중성선용 60 kV 부싱의 기초 절연설계 (The Basic Insulation Design of 60 kV Bushing for Netural Line of 154 kV Class HTS Transformer)

  • 최재형;최진욱;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권3호
    • /
    • pp.32-35
    • /
    • 2008
  • A common problem in many fields of cryogenic power engineering is applying high voltage to cold parts of superconducting apparatus. In many cases, a bushing provides electrical insulation for the conductor which makes the transition from ambient temperature to the cold environment. The 60 kV class cryogenic high voltage bushing for neutral line of the 154 kV / 100MVA high temperature superconducting (HTS) transformer was described. The bushing is energized with the line-to-ground voltage between the coaxial center and outer surrounding conductors; in the axial direction, there was a temperature difference from ambient to about 77 K. For the insulation design of cryogenic bushing, electrical insulation characteristics of the GFRP were discussed in this paper.

LNG 배관 시스템용 1인치 글로브 밸브 개발 및 성능실험 (Development and Performance Test on the 1-Inch Glove Valve for the LNG Piping System)

  • 이중섭;이치우
    • 한국기계가공학회지
    • /
    • 제16권1호
    • /
    • pp.9-16
    • /
    • 2017
  • This study describes the development of a 1-inch cryogenic glove valve for an LNG pumping system and localization development achieved through the performance test. The cryogenic valve used in the LNG pumping system plays an important role in maintaining a flow rate by LNG transportation. This trial manufactured goods, which was achieved through reverse engineering and developing the assembly process. The result of the leak test satisfied the internal pressure condition using the 78-bar normal temperature test and maintained the anti-leakage condition. Also, the result of the cryogenic leak test (BS 6364: low temperature test procedure) maintained anti-leakage at -196 and 52 bar, which satisfied the test standards.

Study of thermoacoustic oscillations in half-open tubes for saturated superfluid helium

  • Wang, Xianjin;Niu, Xiaofei;Bai, Feng;Zhang, Junhui;Chen, Shuping
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.68-73
    • /
    • 2022
  • Thermoacoustic oscillations (TAOs) are spontaneous pressure oscillations frequently seen in hydrogen or helium cryogenic systems. Half-open tubes connected to cryogenic fluid with a closed room temperature end have a high potential for oscillation generation. Thermoacoustic oscillations will result in significant pressure fluctuations and additional heat load, endangering the security and stability of the cryogenic system. The goal of this paper is to investigate TAOs in superfluid helium using both theoretical and experimental methods. Five half-open tubes with varied typical inner diameters inserted into superfluid helium were installed in a test cryostat. The onset characteristics of thermoacoustic oscillations were presented and studied. The effect of temperature profile was discussed. Finally, a simple eliminating method was introduced.

Breakdown Characteristics of Insulation Materials for a Termination of Power Transmission Class HTS Cable

  • Kwag Dong-Soon;Cheon Hyeon-Gweon;Choi Jae-Hyeong;Kim Sang-Hyun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권2호
    • /
    • pp.37-42
    • /
    • 2006
  • A research on several characteristics such as volume breakdown and surface discharge of insulators for a termination of power transmission class HTS cable was performed. We investigated the surface discharge of glass fiber reinforced plastic (GFRP) under air, cryogenic nitrogen gas and nitrogen gas media. The breakdown characteristics of these media were studied. Experimental results revealed that flashover voltage greatly depends on pressure, temperature, the kinds of insulating media and voltages, but it is slightly affected by shape and material of electrode. The breakdown voltage of liquid nitrogen, cryogenic nitrogen gas and nitrogen gas deeply depends on the shape and dimension of electrode, kinds of voltages and pressure. Moreover, the breakdown voltage of cryogenic nitrogen gas and flashover voltage of GFRP in the cryogenic nitrogen gas is also influenced by temperature and vapour-mist density of the gas.