• Title/Summary/Keyword: Cryocooler

Search Result 188, Processing Time 0.036 seconds

A study on the in-line type inertance tube pulse tube cryocooler for cooling Superconductor filter

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Kim, Seon-Young;Jung, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.46-50
    • /
    • 2004
  • The Experimental results of the in-line type inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. The pulse tube refrigerator, which has no moving parts at its cold section, is attractive in obtaining higher reliability, simpler construction, and lower vibration than any other small refrigerators. The purpose of this study is to analyze the characteristics of in-line type inertance tube pulse tube refrigerator (IPTR), and to get main factor to improve the performance of the in-line type IPTR. Firstly, design parameters of the in-line IPTR are discussed by ARCOPTR program, and then to find optimal conditions of in-line type IPTR, cool down characteristics according to the variations of the charging pressure, inertance tube volume, regenerator volume and pulse tube volume are measured by the experiment. The lowest temperature of the cold end was about 50 K. Cooling capacity was the highest in the charging pressure of 32 atm. and 5W at 72K. On the other hand, COP of the in-line type IPTR was the highest in the charging pressure of 21 atm. and 0.018 at 77K.

The Basic Insulation Characteristics of Solid-Nitrogen for Cryocooling of HTS Systems (고온초전도 시스템 냉각용 고화질소의 기초 절연 특성)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Lee, Hai-Gun;Song, Jung-Bin;Kim, Hae-Jong;Seong, Ki-Chul;Kim, Sang-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.132-136
    • /
    • 2009
  • Recently, for improvement of the magnetic field of high temperature superconductor (HTS) apparatus, many studies investigating on operating in the range of $20{\sim}65\;K$ with liquid helium or the conducting method using cryocooler are actively reviewed. Also, the cooling method using solid nitrogen as cryogen is being suggested. Since the nitrogen has very large specific heat in solid state, it is expected that it can be operated for a long time without a continuous supply of cooling energy. However, there are still insufficient data on the characteristics of solid nitrogen such as thermodynamic properties and liquid-solid phase change. Especially, there was almost no study done on the electrical insulation properties of solid nitrogen so far. In this study, solid nitrogen to find the electrical characteristics was made by using cryocooler and cryostat, and investigated the flashover discharge and breakdown. The results of this study will be useful as a basic data for electrical insulation design of the HTS system using solid nitrogen as cryogen.

Analysis of electric circuit using capacitor for driving linear compressor (콘덴서를 이용한 선형압축기 구동 전기회로 해석)

  • Ko, Jun-Seok;Kim, Hyo-Bong;Park, Seong-Je;Hong, Yong-Ju;Yeom, Han-Kil;Koh, Deuk-Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.43-47
    • /
    • 2012
  • A linear compressor generates pulsating pressure and oscillating flow in a cryocooler such as Stirling cryocooler and pulse tube refrigerator. It is driven by AC power source and designed to operate at resonance of piston motion. The driving voltage level is determined by electric parameters of resistance, inductance and thrust constant of linear motor. From voltage equation on linear motor, the power factor of driving power is inherently less than 1. The phase difference between voltage and current of supplied power can be zero using capacitor and this can minimize a supply voltage level. Especially, the linear compressor of kW class requires high voltage and thus can cause a difficulty in selecting power supply unit due to limitation of voltage level. The capacitor in driving electric circuit is useful to settle this problem. In this study, the electric circuit of linear compressor is analytically investigated with assumption of mechanical resonance. The electric parameters of commercial linear motor are used in the analysis. The effects of capacitor on driving voltage level and power factor are investigated. From analytic results, it is shown that the voltage level can be mimized with using capacitor in driving electric circuit.

Thermodynamic Analysis of Hydrogen Lquefaction Systems Using Gifford-McMahon Cryocooler

  • Chang, Ho-Myung;Park, Dae-Jong;Kang, Byung-Ha
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.2
    • /
    • pp.39-50
    • /
    • 2000
  • Thermodynamic cycle analysis is presented to estimate the maximum liquefaction rate of hydrogen for various systems using a Gifford-McMahon(GM) cryocooler. Since the present authors` previous experiments showed that the gaseous hydrogen was liquefied approximately at the rate of 5.1 mg/s from the direct contact with a commercial two-stage GM refrigerator, this study has been proposed to predict how much the liquefaction rate can be increased in different configurations using the GM cooler and with improved heat exchangers. The optimal operating conditions have been analytically sought with real properties of normal hydrogen for the Linde-Hampson(L-H) system precooled by single-stage GM, the direct-contact system with two-stage GM, the L-H system precooled by two-stage GM, and the direct-contact system with helium GM-JT (Joule-Thomson). The maximum liquefaction rate has been predicted to be only about 7 times greater than the previous experiment, even though the highly effective heat exchangers may be employed. It is concluded that the liquefaction rate is limited mainly because of the cooling capacity of the commercially available GM cryocoolers and a practical scale of hydrogen liquefaction is possible only if the GM cooler has a greater capacity at 70-100 K.

  • PDF

A Study on the Electrical and Mechanical Properties of AlN for Insulation of a Conduction-Cooled HTS SMES (전도냉각 고온초전도 SMES 절연용 AlN의 전기적 및 기계적 특성 연구)

  • Choi, J.H.;Kwag, D.S.;Cheon, H.G.;Min, C.H.;Kim, H.J.;Jung, S.Y.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.957-958
    • /
    • 2007
  • The conduction-cooled HTS SMES magnet is operated in cryogenic temperature. The insulation design at cryogenic temperature is an important element that should be established to accomplish miniaturization that is a big advantage of HTS SMES. However, the behaviors of insulators for cryogenic conditions in air or vacuum are virtually unknown. Therefore, we need active research and development of insulation concerning application of the conduction-cooled HTS SMES. Specially, this paper was studied about high vacuum and cryogenic temperature breakdown and flashover discharge characteristics between cryocooler and magnet-coil. The breakdown and surface flashover discharge characteristics were experimented at cryogenic temperature and vacuum. Also, we were experimented about mechanical properties of 4-point bending test. From the results, we confirmed that about research between cryocooler and magnet-coil established basic data in the insulation design.

  • PDF

Closed-Loop Cooling System for High Field Mangets (고자기장용 자석을 위한 밀폐순환형 냉각장치)

  • Choi, Y.S.;Kim, D.L.;Lee, B.S.;Yang, H.S.;Painter, T.A.;Miller, J.R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • A closed-loop cryogenic cooling system for high field magnets is presented. This design is motivated by our recent development of cooling system for 21 tesla Fourier Transform ion Cyclotron Resonance (FT-ICR) superconducting magnets without any replenishment of cryogen. The low temperature superconducting magnets are immersed in a subcooled 1.8 K bath, which is connected hydraulically to the 4.2 K reservoir through a narrow channel. Saturated liquid helium is cooled by Joule-Thomson heat exchanger and flows through the JT valve, isenthalpically dropping its pressure to approximately 1 6 kPa, corresponding saturation temperature of 1.8 K. Helium gas exhausted from pump is now recondensed by two-stage cryocooler located after vapor purify system. The amount of cryogenic Heat loads and required mass flow rate through closed-loop are estimated by a relevant heat transfer analysis, from which dimensions of JT heat exchanger and He II heat exchanger are determined. The detailed design of cryocooler heat exchanger for helium recondensing is performed. The effect of cryogenic loads, especially superfluid heat leak through the gap of weight load relief valve, on the dimensions of cryogenic system is also investigated.

A Study on the Insulation Properties of Cryogen for the HTS SMES (고온 초전도 에너지 저장장치용 극저온 냉매의 절연 특성 연구)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Lee, Hai-Gun;Song, Jung-Bin;Kim, Hae-Jong;Seong, Ki-Chul;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.16-19
    • /
    • 2009
  • Recently, for improvement of the magnetic field of high temperature superconductor (HTS) apparatus, many studies investigating on operating in the range of $20{\sim}65K$ with liquid helium or the conducting method using cryocooler is actively reviewed. Also, the cooling method using solid nitrogen as cryogen is being suggested. Since the nitrogen has very large specific heat in solid state, it is expected that it can enable long time operation without a continuous supply of cooling energy. However, there is still insufficient data on the characteristics of solid nitrogen such as thermodynamic properties and liquid-solid phase change. Especially, there was almost no study done on the electrical insulation properties of solid nitrogen so far. In this study, solid nitrogen to find the electrical characteristics was made by using cryocooler and cryostat, and investigated the flashover discharge and breakdown. The results of this study will be useful as a basic data for electrical insulation design of the HTS system using solid nitrogen as cryogen.

Feasibility Study of an HTS Transformer (고온 초전도 변압기 경제성 평가)

  • 김성훈;김우석;한송엽;최경달;주형길;홍계원
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.229-232
    • /
    • 2002
  • In this paper, we investigated the cost comparison between a 30 MVA high temperature superconducting(HTS) transformer and a conventional large power transformer, and estimated a break even point in time of the HTS transformer comparing to the conventional large power transformer. A value between 5, 000 and 8, 500 kA-m is chosen to calculate the price of HTS tape in a 30 MVA HTS transformer. And the number of cryocooler is decided by estimating the generated energy loss in HTS transformer.

  • PDF

Heat Transfer Analysis of the Radiation Shield in Cryogenic Systems (극저온 시스템의 복사쉴드의 열전달 해석)

  • 정은수;박희찬;양형석;장호명
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.177-180
    • /
    • 2002
  • A numerical model to obtain the temperature distribution in a radiation shield of cryogenic systems was proposed. Conformal mapping was used to transform the eccentric physical region of the upper plate to the concentric numerical region. The effects of the thickness of the radiation shield, the emissivities of the vacuum chamber and the radiation shield, and the eccentricity between the centers of the upper plate and the contact area with a cryocooler on the maximum temperature difference in a radiation shield were shown.

  • PDF