A STUDY ON THE ACCURACY OF THE ROOT-ZX IN THE CANAL WITH MECHANICALLY FORMED CONSTRICTION (기계적 협착부를 갖는 근관에서 Root-ZX의 정확도에 관한 연구)

  • Kim, Byung-Hyun;Lee, Young-Kyoo;Kim, Young-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.628-632
    • /
    • 1999
  • Currently electronic apex locators have been widely used to determine working length in endodontic treatment. According to Manufacture's recommendation, it is beneficial to find the working length before instrumenting the canal. However, in crown-down pressureless technique, working length of tooth is established following coronal instrumentation 3mm short of radiographic apex. In narrow canals, mechanically formed constriction might be established by coronal instrumentation in some distance from anatomical constriction. The purpose of this study was to evaluate the accuracy of Root-ZX in the canal with mechanical constriction following considerable coronal enlargement with ProFile .06 series. The 40 root canals in 30 extracted mandibular molars were accessed, and their actual length (AL) established by passing a size 10 file just through the minor apical foramen. The teeth were then embedded in an acrylic container with normal saline. The initial canal length(IL) was measured with Root-ZX by negotiating a size 10 file to the apical constriction. The canal was sequentially enlarged to size 40 with ProFile .06 file 3mm short of actual length. The enlarged final canal lengths (FL) were obtained with a size 15 file. The average values of IL, FL were calculated and compared using Repeated measures Analysis of Variance followed Turkey's Studentized Range test. The results were obtained as follows: 1. The initial canal length was 0.12mm shorter than actual canal length(P>0.05). 2. The differences between initial canal length and final canal length were not significant(P>0.05). 3. As a result of this study, regardless of mechanically formed constriction. Root-ZX differentiated between mechanical and anatomic constriction.

  • PDF

LEAKAGE EVALUATION OF SEVERAL SEALERS USING ANAEROBIC BACTERIAL LEAKAGE MODEL (혐기성세균모델을 이용한 봉함제(Sealer)의 미세누출에 관한 연구)

  • Bae, Yong-Kue;Oh, Tae-Suk;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.235-242
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate the sealing ability of three sealers(Sealapex, Pulp canal sealer, AH26) used with continuous wave method using an anaerobic bacterial leakage model. 53 extracted human teeth with straight and single canals were prepared with crown-down pressureless technique using .04, .06 taper Profile(Maillefer, Swiss). Master apical file was maintained as #35 K-file. All canals of the experimental teeth were obturated with continuous wave method using System B(Analytic technology, U.S.A.) The teeth were randomly divided into three experimental groups of 15 and two control groups of 4. Experimental group 1 was obturated with Sealapex and group 2 with Pulp canal sealer, and group 3 with AH26. A dual chamber anaerobic bacterial leakage model was assembled. Brain heart infusion with yeast extract, hemin, menadion, and the chromogenic indicator bromocresol purple was used as the culture broth for Fusobacterium nucleatum(VPI 10197), The specimens were incubated in anaerobic chamber at $37^{\circ}C$ and were observed every 2 to 3 clays, The coronal leakage was evaluated through the color change of culture broth in lower chamber for 60 days. The results were as follows: 1. The incidence of bacterial leakage in group 1 (Sealapex group was 80%, 53% in group 2 (Pulp canal sealer), 27% in group 3 (AH26). 2. There were statistically significant differences in leakage scores between group 1 and group 2, and between group 1 and group 3, respectively. (P<0.05) 3. There was no significantly difference in leakage score between group 2 and group 3. (P>0 05)

  • PDF

THE EFFECT OF SMEAR LAYER TREATMENT ON THE MICROLEAKAGE (Smear layer 처리에 따른 미세누출에 대한 연구)

  • Lee, Jung-Min;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.378-389
    • /
    • 2006
  • The purpose of this study was to compare the sealing ability of root canal obturation with or without the treatment of smear layer. Eighty extracted human teeth with one canal were selected Instrumentation was performed with crown-down technique. After instrumentation, root canals of the NaOCl group and NaOCl-6 group were irrigated with 3% NaOCl. EDTA group and EDTA-6 group were irrigated with 17% EDTA. Then all teeth were obturated using continuous wane obturation technique NaOCl group and EDTA group were immersed in methylene blue solution for 84hours. NaOCl-6 group and EDTA-6 group were immersed in methylene blue solution for 6months. The teeth were sectioned at 1.5 mn (Level 1), 3.0 mm (Level 2) and 4.5 mm (Level 3) from the root apex. The length of dye-penetrated inter-face and the circumferential length of canal at each level were measured using Sigma-Scan Pro 5.0. 1. The mean leakage ratio was decreased cervically. 2. NaOCl group showed higher mean leakage ratio than EDTA group at each level. But there was significant difference at level 1 only (p < 0.05). 3. NaOCl-6 group showed higher mean leakage ratio than EDTA-6 group at each level. But there was significant difference at level 1 only (p < 0.05). 4. NaOCl-6 group showed higher mean leakage ratio than NaOCl group at each level. But there was significant difference at level 1 only (p < 0.05). 5. EDTA-6 group showed higher mean leakage ratio than EDTA group at each level. But there was no significant difference. 6. In NaOCl group and NaOCl-6 group, scanning electron micrographs of tooth sections generally covered with smear layer. In EDTA group and EDTA-6 group, tooth sections showing the penetration of sealers to opened dentinal tubules. The results suggest that removal of smear layer was effective to reduce the apical microleakage of the root canal.

Obturation efficiency of non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments (0.06-경사도의 니켈-티타늄 기구로 형성된 레진 만곡근관에서 비표준화 GUTTA-PERCHA CONE의 근관충전 효율)

  • Lee, Eun-Ah;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.79-85
    • /
    • 2005
  • The purpose of this study was to evaluate the obturation efficiency of a non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments. Sixty simulated curved root canals in clear resin blocks were prepared with crown-down technique using 0.06 taper rotary $ProTaper^{TM}$and ProFile (Dentsply-Maillefer) until apical canal was size 30. Root canals were randomly divided into 4 groups of 15 blocks and obturated with cold-laterally compacted gutta-percha technique by using either a non-standardized size medium gutta-percha cone or an ISO-standardized size 30 one as a master cone. Gutta-percha area ratio were calculated at apical levels of 1, 3 and 5 mm using AutoCAD 2000 after cross-sectioning, and the data were analyzed with one-way and two-way ANOVAs and Duncan's multiple range test. Non-standardized size medium cone groups showed significantly higher gutta-percha area ratio than standardized cone groups at all apical levels (p < 0.01). Non-standardized cone groups used significantly less accessory cones than standardized cone groups (p < 0.01).

Evaluation of retrievability using a new soft resin based root canal filling material (레진 계통의 근관 충전재의 제거 용이성에 대한 평가)

  • Shin Su-Jung;Lee Yoon;Park Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.323-329
    • /
    • 2006
  • The aim of this study was to evaluate the retrievability of Resilon as a root canal filling material Twenty-seven human single-rooted extracted teeth were instrumented utilizing a crown down technique with Gates-Glidden burs and ProFile system. In group1 (n = 12) canals were obturated with gutta percha and AH-26 plus sealer using a continuous wave technique and backfilled. In group 2 (n = 15) Resilon was used as a filling material. Then teeth were sealed and kept in $37^{\circ}C$ and 100% humidity for 7 days. For retreatment, the samples were re-accessed and filling material was removed using Gates-Glidden burs and ProFiles. Teeth were sectioned longitudinally to compare the general cleanliness and amount of debris $({\times}\;75)$ using SEM. Chi-square test was used $({\alpha}\;=\;0.05)$ to analyze the data. The total time required for removal of filling materials was expressed as mean ${\pm}SD$ (min) and analyzed by the Student t-test $({\alpha}\;=\;0.05)$, Required time for retreatment was $3.25\;{\pm}\;0.32$ minutes for gutta percha/ AH 26 plus sealer and $3.05\;{\pm}\;0.34$ minutes for Resilon. There was no statistically significant difference between the two experimental groups. There was no significant difference between the groups in the cleanliness of the root canal wall. This study showed that Resilon was effectively removed by Gates-Glidden burs and ProFiles.

A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS (엔진구동형 NiTi 파일의 근관성형효과 비교)

  • Kim, Bo-Hye;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.88-95
    • /
    • 2010
  • The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.

The effect of MTAD on the apical leakage of obturated root canals: an electrochemical study (MTAD의 치근단 누출에 미치는 영향에 대한 전기화학적 연구)

  • Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.119-124
    • /
    • 2006
  • The purpose of this study was to evaluate the effect of newly developed endodontic root canal cleanser (MTAD) on the apical leakage of obturated root canal using an electrochemical method. Canals of 60 extracted single-rooted human teeth were prepared by using a crown-down technique with rotary nickel-titanium files. In Group 1 (positive control group) and 2 (negative centre) group), 5.25% NaOCl was used as a canal irrigant and no canal wall treatment was done. In group 3 only 5.25% NaOCl were used as canal irrigant, canal wall treatment and final rinse. In group 4, specimens were irrigated with 5.25% NaOCl, treated with 5 ml of 17% EDTA for 5 minutes and final rinsed with 5.25% NaOCl Specimens of group 5 were irrigated with 1 3% NaOCl and treated with 5 ml of MTAD for 5 minutes. All root canals are dried with paper points and obtuated with gutta-percha and AH plus as a sealer using a continuous wave of condensation technique except in the group 1. The electrical resistance between the standard and experimental electrodes in canals was measured over a period of 10 days. Rising of apical leakage with time was observed for all the groups. Group 4 and 5 showed lower apical leakage than group 3 but differences between the group 3, 4 and 5 were no statistical significance at any measurement time.

센서 네트워크용 초소형 OS

  • Song, Jun-Geun;Ma, Pyeong-Su;Park, Seung-Min
    • Information and Communications Magazine
    • /
    • v.24 no.7
    • /
    • pp.26-35
    • /
    • 2007
  • 최근 몇 년간 유비쿼터스 서비스를 구현하기 위한 핵심 기술 중 하나인 무선 센서 네트워크에 대한 관심이 높아지고 있다. 무선 센서 네트워크 기술은 물류, 유통, 환경 감시, 홈오토메이션, 군사 분야 등 다양한 분야에 적용 될 수 있기 때문에 앞으로 관련 분야의 시장 또한 커질 것으로 예상되고 있다 [1]. 무선 센서 네트워크는 기존 유선 센서 네트워크나 무선 네트워크 환경과는 많은 차이를 가진다. 우선 극도로 제한된 시스템 자원만을 가질 수 있으며, 열악한 환경 속에서 무선매체를 통해 유기적으로 동작하여야 하는 특징을 가지고 있다. 적게는 수십 개에서 많게는 수백, 수천 개의 자율적인 하드웨어 노드들로 구성되는 무선 센서 네트워크에서 제한된 자원을 효과적으로 활용하기 위해서는 센서 노드에 적합한 운영체제가 필수적으로 요구된다. 지난 몇 년간 센서 노드하드웨어의 발달과 더불어 많은 센서 네트워크용 초소형 운영체제가 개발되어왔다. 현재 많이 알려져 있는 센서 네트워크용 OS로는, 가장 활발한 참여를 보이고 있는 TinyOS[3]부터 SOS[4], MANTIS[5], Contiki[6], T-kernel[7] 등이 있으며, 국내 기술로 개발된 Nano-Qplus[8] 등이 존재한다. 본고에서는 우선 센서 네트워크에 대한 배경 지식과 플랫폼 등에 대한 내용을 간단히 다루고, 본론에서 센서 네트워크용 운영체제가 가져야 할 조건과 현재 개발되어 있는 센서 네트워크 OS들의 특징에 대해 간략히 살펴보도록 하겠다. 또한 센서 네트워크 OS와 밀접한 연관성을 가지는 분야에 대해 간단히 살펴보고, 마지막으로 앞으로의 방향에 대해 알아본다.고려해 볼 때 atlas의 장축의 시계방향 회전은 액티베이터의 사용 효과로 생각되며, 이는 차후 II급 부정교합자에서 액티베이터 치료 효과를 판단하는 또 하나의 지표가 될 수 있다고 생각한다.인해 한반도를 포함한 동아시아 대륙이 태평양판 쪽으로 밀려감으로써 섭입하던 태평양판의 각도가 급해져 동아시아 연변에 강력한 흡입력이 발생하였으며, 이 때문에 태평양판의 운동 방향이 북북서에서 서북서방향으로 회전되었을 가능성이 있다. 따라서 약 51 Ma부터 한반도 동남부에는 지판 경계의 강력한 흡입력으로 동서 내지 서북서-동남동의 인장력이 작동되어 B그룹 암맥군이 관입한 것으로 해석된다.Ledge는 세 군 모두에서 나타나지 않았다. 4. 파일 binding 횟수는 MC군이 가장 적고 PT군이 가장 많았다 (p < 0.05). 이상의 결과를 볼 때, Mtwo 전동 파일을 crown-down technique으로 사용하는 것이 single length technique과 유사한 성형 효율을 보이면서도 더 안전할 것으로 추정된다.고 1명(3%)에서 원격전이를 보였다. 치료 중 급성 합병증으로 11명(37%)에서 RTOG grade 1-2의 장염을 보였으며 1명은 대장의 천공이 발생하여 수술로 치유되었다. 12명(40%)에서 RTOG grade 1-2의 급성 방광염을 보였다. 3명(10%)에서 RTOG grade 1-2의 백혈구 감소증이 보였으며 1명에서 심한 백혈구 감소증(RTOG grade 4)이 나타났으나 회복되어 치료를 완료하였다. 만성 합병증으로 5명(15%)에서 RTOG grade 1-2의 만성 장염을 보였으며 별다른 치료 없이 지내고 있으며

A COMPARATIVE STUDY ON THE CANAL CONFIGURATION AFTER SHAPING BY PROFILE, PROTAPERTM AND K-FLEXOFILE IN SIMULATED CANALS WITH DIFFERENT ANGLES OF CURVATURE (ProFile, ProTaperTM K-Flexofile 근관 성형시 근관의 만곡도에 따른 근관 형태 변화 비교연구)

  • Lee, Bo-Kum;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.294-302
    • /
    • 2005
  • The purpose of this study was to evaluate the canal configuration after shaping by ProFile. ProTaper and K-Flexofile in simulated resin canals with different angles of curvature. Three types of instruments were used: ProFile. ProTaper. K-Flexofile. Simulated root canals. which were made of epoxy resin. were prepared by ProFile. ProTaper with rotary instrument using a crown-down pressureless technique. and hand instrumentation was performed by K-Flexofile using a step-back technique. All simulated. canals were prepared up to size 25 file at end-point of preparation. Pre and post instrumentation images were recorded with Scanner. Assessment of canal shape was completed with Image Analysis program. Measurements were made at 1. 2. 3. 4. 5. 6. 7. 8. 9 and 10mm from the apex. At each level. outer canal width. inner canal width. total canal width. and amount of transportation from original axis were recorded. Instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA analysis of variance and the Sheffe's test. The result was that ProFile and ProTaper maintain original canal shape regardless of the increase of angle of curvature than K-Flexofile. ProFile show significantly less canal transportation and maintained original canal shape better than ProTaper.

A STUDY ON TRANSPORTATION OF APICAL FORAMEN AFTER OVERINSTRUMENTATION BY PROFILE® ;PROTAPERTM AND K3TM IN SIMULATED CANALS WITH DIFFERENT CURVATURES (ProFile®, ProTaperTM 및 K3TM Ni-Ti 파일의 과기구 조작이 치근단공 변위에 미치는 영향)

  • Yang, Hyun;Yang, In-Seok;Hwang, Yun-Chann;Hwang, In-Man;Yoon, Suk-Ja;Kim, Won-Jae;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • This study was done to evaluate transportation of the apical foramen after 0.5 mm overinstrumentation by ProFile, ProTaper and $K^3$ in simulated resin root canal. Sixty simulated resin root canal with a curvature of J and S-shape were divided into two groups. Each group consisted of three subgroups with 10 blocks according to the instruments used: $ProFile^{(R)},\;ProTaper^{TM},\;and\;K^{3TM}$. Simulated resin root canal was prepared by ProFile, ProTaper and $K^3$ with 300 rpm by the crown-down preparation technique. Pre- and post-instrumentation apical foramen images were overlapped and recorded with Image-analyzing microscope 100X (Camcope, Sometech Inc, Korea). The amounts of difference in width and dimension on overlapped images were measured after reference points were determined by Image Analysis program ($Image-Pro^{(R)}$ Express, Media Cybernetic, USA). Data were analyzed using Kruskal-Wallis and Mann-Whitney U-test. The results suggest that ProFile showed significantly less canal transportation and maintained original apical foramen shape better than $K^3$ and ProTaper.