• Title/Summary/Keyword: Crown diameter

Search Result 281, Processing Time 0.025 seconds

Correlation Analysis on Several Factors and Collection Amount of Rhus Lacquer by the Sex of Rhus verniciflua (옻나무의 암수에 따른 주요인자와 옻채취량의 상관분석)

  • Song Byong-Min;Lee Cheol
    • Korean Journal of Plant Resources
    • /
    • v.18 no.2
    • /
    • pp.279-284
    • /
    • 2005
  • The study was conducted to investigate the correlation and regression analysis between the factors - diameter, hight and crown width - and collection amount of Rhus lacquer by the sex of Rhus verniciflua. The relationship between the diameter and the collection amount of the lacquer by the sex of the lacquer tree indicated that, for both of the male and the female, the lacquer amount was likely to increase as the diameter got larger. In general, the male trees tended towards the higher amount of the lacquer than the female. The relationship between the crown width and the collection amount of the lacquer by the sex showed little difference. As the crown became wider, however, the lacquer amount showed the increasing trend. The regression analysis by the sex of the tree indicated that the major factors of the female had larger influence on the lacquer amount than those of the male. The no differences of statistical significance were found among the diameter, the height, the crown width, and the lacquer amount.

EFFECT OF TAPER AND SURFACE AREA OF INNER CROWN ON THE RETENTIVE FORCE OF ELECTROFORMED OUTER CROWN (전기성형술로 제작된 외관의 유지력에 내관의 축면경사도와 표면적이 미치는 영향)

  • Kang Wan-Keun;Lim Jang-Seop;Jeon Young-Chan;Jeong Chang-Mo;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.165-173
    • /
    • 2006
  • Purpose: With gold electroforming system fir the double crown, the secondary crown is electroformed directly onto the primary crown. An even thick layer of high precision can be acquired. It is thought that the retention of electroformed outer crown is primarily acquired by the adhesive force (surface tension) through the saliva which is interposed between precisely fitted inner and outer crown. The purpose of this study was to investigate the effect of taper and surface area of inner crown on the retentive force of electroformed outer crown according to the presence of saliva. Materials and methods: 32 titanium inner crowns with cervical diameter of 8 mm and cone angles of 0, 2, 4, 6 degrees, which had same surface area by regulated height, were machined on a lathe. Another 32 titanium inner crowns with cone angles of 0, 2, 4, 6 degrees, which had doubled surface area by increased cervical diameter. were fabricated. Eight specimens of each group, for a total of 64 titanium inner crowns, were prepared. The electroformed outer crowns were fabricated directly on the inner crowns by using electroforming machine(GAMMAT free, Gramm Technik, Germany). The tertiary frameworks were waxed-up on the electroformed outer crown and cast using nonprecious alloy($Rexillium^(R)III,\;Jeneric^(R)/Pentronh^(R)$ Inc., USA). The cast metal frameworks were sandblasted with alubimium oxides and cemented using resin cement(Superbond C&B, Sun Medical Co., Japan) over the electroformed copings of each specimen. Then, artificial saliva($Taliva^(R)$, Halim Pharm. Co., Korea) was sprayed between the inner and outer crown, and they were connected under 5 kg force. The retentive force was measured by the universal testing machine(Tinius Olsen 1000, Tinius Olsen, USA) with a cross-head speed of 66.67 mm/sec. The direction of cross-head travel was exactly aligned with the path of removal of the respective specimens. This measurement procedures for retentive force of electroformed outer crown with artificial saliva were repeated in the same way without presence of artificial saliva. Results and Conclusion: The following conclusions were drawn: 1. The retentive force of electroformed outer crown was decreased according to increased taper of inner crown(P<.05). 2. The retentive force of electroformed outer crown showed no significant differences according to surface area and the presence of artificial saliva(P>.05).

Effects of Root Head Diameter and Fertilization on Shoot Growth and Root Yield in Angelica gigas NAKAI (근두경의 크기와 시비가 참당귀의 생육 및 수량에 미치는 영향)

  • 조선행;김기준
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.36 no.3
    • /
    • pp.254-258
    • /
    • 1991
  • Experiment was conducted to investigate the effects of size of root crown at transplanting and fertilization on the growth and root yield of Angelica gigas Nakai. Plant height and fresh weight of shoots were increased by fertilizer application, but was not different in emergence rate. Size of root crown at transplanting was also affected the growth of shoot. Plant which had 7.2mm of root crown at transplanting showed highest in plant height and fresh weight of shoots. Growth of root in terms of root length, number of root branches, diameter of root crown, and fresh weight of root was increased by fertilizer application and 5.4mm of root crown at transplanting. Application of fertilizer accelerated the development and growth of node on the stem, which in turn resulted bolting and flowering. Plants which had greater than 7.2mm of root crown at transplanting and application of fertilizer were produced woody roots. Woody roots cannot be used for medicinal purpose. Therefore, yield of roots was highest at transplanting of 3.lmm root crown with fertilizer application.

  • PDF

MEASURING CROWN PROJECTION AREA AND TREE HEIGHT USINGLIDAR

  • Kwak Doo-Ahn;Lee Woo-Kyun;Son Min-Ho
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.515-518
    • /
    • 2005
  • LiDAR(Light Detection and Ranging) with digital aerial photograph can be used to measure tree growth factors like total height, height of clear-length, dbh(diameter at breast height) and crown projection area. Delineating crown is an important process for identifying and numbering individual trees. Crown delineation can be done by watershed method to segment basin according to elevation values of DSMmax produced by LiDAR. Digital aerial photograph can be used to validate the crown projection area using LiDAR. And tree height can be acquired by image processing using window filter$(3cell\times3cell\;or\;5cell\times5cell)$ that compares grid elevation values of individual crown segmented by watershed.

  • PDF

Distribution, Size and Development Phases of Knots for Pinus sylvestris L. var. mongolica Litvin in Northeast China

  • Jia, Weiwei;Li, Fengri
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.5 s.162
    • /
    • pp.313-320
    • /
    • 2005
  • This study was performed in a 38-year-old Mongolian pine (Pinus sylvestris L. var. mongolica Litvin) plantation in northeast China. Data were collected from 5 sample trees with different canopy position ranging in DBH from 14.6 cm to 23.8 cm. Sawn speciments that included the biggest knot were taken from the stem below the living crown. Number and distribution of knots per whorl below the living crown were studied by relative height below living crown (RHBC). A linear model expressed as function of whorl age (AGE), whorl height ($H_k$) and the stem diameter at which the whorl was located ($D_k$) was developed to predict the knot diameter and angle. The number of annual rings in four periods and the width of respective zone alone stem were used as dependant variables to analyze the knot develop phases. In average, the number of years from branch birth to ceased forming rings was 7.8, the branches remained alive for 4.2 years without forming annual rings, and branches were occluded 14.4 years after their death. These results can provide abundance branch and knot information so as to describe current and past tree growth dynamic of Mongolian pine plantation.

Finite element analysis on the stress of supporting bone by diameters and lengths of dental implant fixture (유한요소법을 이용한 치과 임플란트 고정체의 직경과 길이에 따른 지지골의 응력 분석)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.151-156
    • /
    • 2016
  • Purpose: The dental implant should be enough to endure chewing load and it's required to have efficient design and use of implant to disperse the stress into bones properly. This study was to evaluate the stress distribution on a supporting bone by lengths and diameters of the implant fixture. Methods: The modeling and analysis of stress distribution was used for the simple molar porcelain crown model by Solidworks as FEM program. It was designed on applying with tightening torque of 20 Ncm of a abutment screw between a cement retained crown abutment and a fixture. The fixtures of experimental model used 10, 13mm by length and 4, 5mm by diameter. A external vertical loading on the two buccal cusps of crown and performed finite element analysis by 100 N. Results: The maximum von Mises stress(VMS) of all supporting bone models by fixture length and diameter were concentrated on the upper side of supporting compact bone. The maximum stress of each model under vertical load were 164.9 MPa of M410 model, and 141.2 MPa of M413 model, 54.3 MPa of M510 model, 53.6 MPa of M513 model. Conclusion: The stress reduction was increase of fixture's diameter than it's length. So it's effective to use the wider fixture as possible to the conditions of supporting bone.

A 3-dimensional Finite Element Analysis of Stress Distribution in the Supporting Bone by Diameters of Dental Implant Fixture (골유착성 치과 임플랜트 고정체 직경에 따른 지지골의 응력분포에 관한 삼차원 유한요소 분석적 연구)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.69-76
    • /
    • 2004
  • The objective of this finite element method study was to analyze the stress distribution induced on a supporting bone by 3.75mm, 4.0mm, 5.0mm diameter of dental implant fixture(13mm length). 3-dimensional finite element models of simplified gold alloy crown(7mm height) and dental implant structures(gold cylinder screw, gold cylinder, abutment screw, abutment, fixture and supporting bone(cortical bone, cancellous bone) designs were subjected to a simulated biting force of 100 N which was forced over occlusal plane of gold alloy crown vertically. Maximum von Mises stresses(MPa) under vertical loading were 9.693(3.75mm diameter of fixture), 8.885(4.0mm diameter of fixture), 6.301(5.0mm diameter of fixture) and the highest von Mises stresses of all models were concentrated in the surrounding crestal cortical bone. The wide diameter implant was the good choice for minimizing cortical bone-fixture interface stress.

  • PDF

Effects of Tree Form on Number of Cone Formation in Korean White Pine (Pinus koraiensis S. et Z.) (잣나무에 있어서 수형(樹形)이 결실량(結實量)에 미치는 영향(影響))

  • Chon, Sang Keun;Noh, Youn Hee
    • Journal of Korean Society of Forest Science
    • /
    • v.62 no.1
    • /
    • pp.19-23
    • /
    • 1983
  • Number of 1-year-old cone in Pinus koraiensis was influenced by the factors consisting of the tree form. Number of cones increased with increasing DBH, diameter, volume of crown and number of forked stems. However, tree height, crown length, and the ratio of crown diameter to crown length showed no significant relations with number of cones.

  • PDF

Crown Fuel Characteristics and Fuel Load Estimation of Pinus densiflora S. et Z. in Bonghwa, Gyeongbuk (경북 봉화 지역 소나무림에 대한 수관연료 특성과 연료량 추정)

  • Jang, Mina;Lee, Byungdoo;Seo, Yeonok;Kim, Sungyong;Lee, Young Jin
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.3
    • /
    • pp.402-407
    • /
    • 2011
  • The objectives of this study were to analyze the crown vertical structure, crown bulk density, and to develop regression models for predicting crown fuel load using the data from 10 destructively sampled Pinus densiflora trees in Bonghwa, Gyeongbuk. The fuel loads were observed higher in the middle portion of the vertical distribution of crown followed by the lower portion and upper portion of Pinus densiflora, respectively. Approximately 25% crown fuel load was found in the needle while 33% was observed in the branches with <1 cm diameter with a total of 58% available fuel loads. The average crown bulk density was $0.45kg/m^3$, and $0.27kg/m^3$ of this was available in the needles and branches with <1 cm diameters. The resulting models in linear equations were able to account for 84% and 88% of the observed variation, while the allometric equations with diameter at breast height as the single predictor showed better results to account for 90% and 95% of the observed variation in the available crown fuel loads and total crown fuel loads, respectively. The suggested equations in this study could provide quantitative fuel load attributes for crown fire behavior models and fire management of red pine stands in Bonghwa areas.

A MORPHOMETRIC STUDY OF THE MAXILLARY PRIMARY FIRST MOLARS USING THREE-DIMENSIONAL SCANNER (3차원 스캐너를 이용한 상악 제1유구치 치관의 크기와 형태에 관한 연구)

  • Lee, Jong-Beom;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.643-652
    • /
    • 2006
  • The purpose of this study was to elucidate the size and morphologic characteristics of maxillary primary first molars in Korean children using three-dimensional laser scanner and compare three-dimensional image with preformed stainless steel crown. Scanned three-dimensional images of dental cast taken from 132 children(male 62, female 70) by three-dimensional laser scanner(Breuckmann opto-Top HE100, INUS, Korea) were used. Mesiodistal diameter, buccolingual diameter, occlusogingival height and crown shape of each image were calculated by Rapidform 2004 program(INUS, Korea). The values were statistically compared by independent samples t-test with 95% of significant level. The results were as follows : 1. No significant difference in crown size was found between left and right maxillay primary first molar(p>0.05). 2, Significant difference in mesiodistal diameter, buccolingual diameter, buccal occlusogingival height was found between male and female (p<0.05), and crown size of male was bigger than that of female. 3. Average image of maxillay primary first molar was shaped three-dimensionally and measured. In comparison with 3M stainless steel crown, this image was similar with No.4 or No.5 SS crown in male, No.4 in female. In comparison with ILSUNG SS crown, this image was similar with No.5 in male, No.4 in female. 4 Mesiolingual line angle area, distolingual line angle area and buccogingival ridge were more obvious in average image than 3M stainless steel crown. ILSUNG SS crown was more square and had longer mesiodistal diameter than average 3D image.

  • PDF