A Surface Treatment Technique for Interim Crown Fabricated by Three-Dimensional Printing with Digital Light-Processing Technology

  • Son, Keunbada;Lee, Jaesik;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • 제14권2호
    • /
    • pp.79-89
    • /
    • 2021
  • Purpose: The technique introduced in this study describes a technique for surface treatment that applies a photocuring resin to the surface of an interim crown fabricated by three-dimensional (3D) printing without a conventional polishing method. The purpose of this study was to evaluate marginal and internal fit and the intaglio surface trueness of interim crowns after surface treatment of 3D-printed crowns for clinical application. Materials and Methods: An interim crown was fabricated using a 3D printer with digital light-processing technology, and the surface support was removed. After the posttreatment process, the resin was thinly applied to the surface of the interim crown and polymerized to solve the esthetic problem of the surface without the conventional polishing process. In addition, the marginal and internal fits were measured to verify the clinical use of this technique, and the trueness was evaluated to confirm the deformation of the inner surface according to the technical application of the outer surface of the interim crown. The difference before and after the evaluation by a statistical method was verified using an independent t-test (α=0.05). Result: There was no significant difference in the marginal and internal fit before and after the application of this technique (P>0.05). There was no significant difference in intaglio surface trueness before and after the application of this technique (P=0.963). Conclusion: There was no change in the marginal and internal fit or in intaglio surface trueness of the interim crowns to which this technology was applied. This surface treatment technique is a more convenient method for interim crowns fabricated using 3D-printing technology without the conventional polishing process.

베릴륨(Be)이 미 첨가된 치과도재소부용 Ni-Cr-Mo계 합금의 미세조직 및 기계적 성질 특성 (Microstructures and Mechanical Properties of Beryllium(Be)-free Ni-Cr-Mo based Alloys for Metal-Ceramic Crown)

  • 송경우;고은경;이정환;정종현;노학;한재익
    • 대한치과기공학회지
    • /
    • 제28권2호
    • /
    • pp.321-329
    • /
    • 2006
  • The popularity of Ni-Cr-Mo based metal alloys for metal-ceramic crown have increased recently because of low price, superior yield strength and rigidity. the use of these alloys give them the potential advantage of thinner copping with the required rigidity for long span bridges. The purpose of this study was to assess the microstructures and mechanical properties of Ni-Cr-Mo-(Si,Al,Nb,Zr,Ti.Cu,Mm) based Alloys not containing beryllium(Be) related toxic effects. The abtained results indicated that as-cast these specimen alloys showed compositional and microstructural differences, and mechanical properties values of Ni69Cr20Mo5Si2Al4 alloy among these specimen alloys was found to be superior to those of commercial Ni-Cr based alloy using in market place today.

  • PDF

Automatic Detection of the Middle Tooth Crown Part for Full Automatic Tooth Segmentation in Dental CT Images

  • Lee, Chan-Woo;Chae, Ok-Sam
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권3호
    • /
    • pp.17-23
    • /
    • 2018
  • In this paper, we propose the automatic detection method which find the middle part of tooth crown to start individual tooth segmentation. There have been many studies on the automation of individual tooth segmentation, but there are still many problems for full automation. Detection of middle part of tooth crown used as initial information for individual tooth segmentation is closely related to performance, but most studies are based on the assumption that they are already known or they can be represented by using a straight line. In this study, we have found that the jawbone curve is similar to the tooth alignment curve by spatially analyzing the CT image, and propose a method to automatically detect the middle part of tooth crown. The proposed method successfully uses the jawbone curves to successfully create a tooth alignment curve that is difficult to detect. As the middle part of tooth crown is in the form of a tooth alignment curve, the proposed method detects the middle part of tooth crown successfully. It has also been verified by experiments that the proposed method works well on real dental CT images.

치과보철물의 평균수명에 관한 연구 (A Study on the Life Expectancy of the Dental Prosthetic Restorations)

  • Young-Ku Kim
    • Journal of Oral Medicine and Pain
    • /
    • 제20권2호
    • /
    • pp.317-325
    • /
    • 1995
  • This study was performed to investigate the mean life expectancy of dental prosthetic restorations. The author has examined 352 dental prosthesis clinically and radiologically, and decided the success(survival) and failure(mortality) of the dental prosthesis. The dental prosthesis which had been treated in the Seoul National University Dental Hospital, two private clinics in Seoul, one university dental hospital, and two private clinics in local province were included in this study. The survival analysis using product limit estimator was used and the mean life expectancy of each type of dental prosthesis was calculated. The results were as follows : 1. The life expectancies were 10.5 years in gold crown and bridge, 8.5 years in porcelain fused to metal crown and bridge, 8.3 years in nonprecious metal crown and bridge, 8.1 years in removal partial denture, and 7.7 years in full denture. 2. The causes of mortality were in the order of dental caries(24.6%), fracture of dental prosthesis(19.2%), periodontal problems(18.6%), chronic chewing difficulty and dysfunction due to dental prosthesis(15.0%), excessive exposure of abutments due to the marginal defect of dental prosthesis(14.4%), abnormal occlusion due to severe attrition of artificial teeth in dentures(3.0%), periapical problems(2.4%), perforation of dental prosthesis(1.8%), and loose contacts with neighboring tooth(1.2%). 3. Among survival cases, 66.5% showed normal chewing ability and 31.9% showed partial chewing ability. However, 1.6% of them complained loss of chewing ability. 4. Among failure cases, 6.6% showed normal chewing ability and 38.9% showed partial chewing ability. However, 54.5% of them complained loss of chewing ability.

  • PDF

유리단 국소의치의 교합하중 적용시 이중금관, 어태치먼트 및 RPI clasp 유지장치에 따라 지대치와 의치상에 미치는 응력 비교 (Comparison of Stress of the Abutment Teeth and Denture Base in Distal Extension Removable Partial Dentures Retained Konus Crown, Precision Attachment and RPI Clasp with the Occlusal Load Application)

  • 전인식;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제28권2호
    • /
    • pp.331-346
    • /
    • 2006
  • Free-end partial dentures, which are supported by teeth surrounded by dental root membranes and elastic mucous membrane tissues, may cause stress to the abutment teeth due to external force imposed on the denture base, increase the mobility of the abutment teeth, and bring about a change in the periodontal tissue. General retainers used in partial dentures are categorized into clasp, attachment, and Konus crown. Stress imposed on the abutment teeth and mobility of the denture base have relations with the lifetime of a crown and abutment teeth, and have direct relations with the chewing ability. Thus, a need arises to make a comparative analysis of stress of the three direct retainers on the abutment teeth and interpret the mobility of the denture base. This study designed three kinds of removable partial dentures (one kind of attachment partial denture, one kind of Konus crown partial denture, and one kind of clasp partial denture), and fabricated Dentiforms of bilateral partial dentures (Kennedy Class I) with lower left 1st premolar and lower right 1st and 2nd premolars being as the abutment teeth. A strain gauge was installed in the mesial and distal surface of the lowerr left 1st premolar (No. 34) of the fabricated dentiform and in the lower part of the denture base, and installed were a clasp partial denture, an attachment partial denture, and a Konus crown partial denture. Then, the vertical static load of 5kgf and 7.5kgf at the occlusion surface of the lower left No. 6 molar was generated for a total of 20 frequencies of load each using a push-full gauge, and thus a change in the output of the strain gauge was measured. With the respective application of Konus crown, attachment and RPI clasp in the free-end partial denture, surveyed was the distribution of stress imposed on the abutment teeth and the denture base according to the location of occlusion force load so as to come up with the following results. 1. Konus crown and attachment partial dentures generated much stress, and more stress on the abutment teeth than RPI clasp dentures did. Attachment dentures tended to further intensify stress on the abutment teeth than Konus crown dentures did. 2. Attachment dentures and Konus dentures imposed less stress on the denture base than RPI clasp dentures did. There was no stress difference between Attachment and Konus crown dentures. 3. Dentures that were designed with the application of retainers using sturdy linkage methods tended to be less mobile.

  • PDF

The relationships between the arrangement of teeth, root resorption, and dental maturity in bovine mandibular incisors

  • An, Jin-kyu;Matsumoto, Yoshiro;Ono, Takashi
    • 대한치과교정학회지
    • /
    • 제47권6호
    • /
    • pp.365-374
    • /
    • 2017
  • Objective: The objective of this study is to investigate the eruption pattern and root resorption of the bovine anterior dentition in relation to growth-related parameters based on dental maturity. Methods: A cross-sectional study was conducted on 110 bovine anterior mandibles by using standard radiography, cone-beam computed tomography (CBCT), and actual measurements. We determined the relationships between the stages of dental maturity by using a modification of Demirjian's method and various growth-related parameters, such as the activity of the root-resorbing tissue and mobility of the deciduous teeth. The correlation of growth-related parameters with interdental spacing and distal unusual root resorption (DRR) of the deciduous fourth incisor was assessed. The cause of mesial unusual root resorption (MRR) of the deciduous fourth incisor was determined on the basis of the arrangement of the permanent third incisor. Results: An independent t-test and chi-square test indicated significant differences in growth-related parameters associated with dental arch length discrepancy and factors related to the shedding of deciduous teeth between the low and high dental maturity groups. The samples with interdental spacing and DRR showed a larger sum of mesiodistal permanent crown widths and higher dental maturity than did the respective controls. Samples with MRR tended to show a lingually rotated distal tip of the adjacent tooth crown. Conclusions: Dental maturity has relevance to the interdental spaces and unusual root resorption of mixed dentition. The position of the adjacent tooth crown on CBCT may be correlated with the occurrence of unusual root resorption of the incisor.

금관 가공의치에서의 대구치 지대치에 관한 형태학적 연구 (A MORPHOLOGIC STUDY ON MOLAR ABUTMENT DIES)

  • 정헌영
    • 대한심미치과학회지
    • /
    • 제3권1호
    • /
    • pp.44-50
    • /
    • 1995
  • Abutment dies which resemble the actual size and shape of crown abutment is essential in most of the research area of fixed prosthodontics like marginal accuracy, crown seating, behavior of luting agent and so on. Seeing the large portion of research is done with round shaped dies in different size and cone angles, the necessity of research on the crown abutment is self-evident. 500 molar abutments were collected randomly through the commercial dental laboratoy, regrdless of their position in the dental arch, sex, and age. The measurements of 22 points of a die were done, and the results were as fogbows : 1. The height of the molar dies was $3.9{\pm}1.2mm$ 2. The bucco-lingual width was $8.9{\pm}1.2mm$ at the base, and $7.4{\pm}1.2mm$ at the occlusal. 3. The desio-sistal width was $8.2{\pm}1.2mm$ at the base, and $7.0{\pm}1.3mm$ at the occlusal.

  • PDF

인공치관용(人工齒冠用) Glass-Ceramics의 결정화(結晶化)에 관(關)한 연구(硏究) (A Study on the Crystallization of Glass-Ceramics for Dental Crown)

  • 정인성
    • 대한치과기공학회지
    • /
    • 제14권1호
    • /
    • pp.95-118
    • /
    • 1992
  • Glass ceramics for crown were prepared by adding 3$\sim$11 wt% TiO2 to the weight percent composition of 34.7 CaO, 27.8 SiO2, 18.3P2O5, 12.6MgO and 6.6 TiO2. The starting glasses were prepared by melting the powdered batch in alumina crucible at 1350$\sim$1400 for 1 hr and then quenching into a distilled water. The nucleation and crystallization of the crystalline glass ceramics for crown were studied by DTA, SME and X-ray diffraction analysis. Frit containing 9.11 wt% TiO2 had crystallization temperature of 850$\sim$1075 and major crystalline phase was identified by X-ray diffraction as diopside(CaO-MgO-2SiO2). Activation energies for the crystallization processes were obtained from DTA by varing rates for the fits, and were calculated from modified Ozawa and Kissinger equations. Activation energy for the crystallization processes of the S-4 frit was 489.6 KJ/mol.

  • PDF