• Title/Summary/Keyword: Cross-coupled Control

Search Result 76, Processing Time 0.023 seconds

Comparative analysis of two methods of laser induced boron isotopes separation

  • K.A., Lyakhov;Lee, H.J.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.407-408
    • /
    • 2011
  • Natural boron consists of two stable isotopes 10B and 11B with natural abundance of 18.8 atom percent of 10B and 81.2 atom percent of 11B. The thermal neutron absorption cross-section for 10B and 11B are 3837 barn and 0.005 barn respectively. 10B enriched specific compounds are used for control rods and as a reactor coolant additives. In this work 2 methods for boron enrichment were analysed: 1) Gas irradiation in static conditions. Dissociation occurs due to multiphoton absorption by specific isotopes in appropriately tuned laser field. IR shifted laser pulses are usually used in combination with increasing the laser intensity also improves selectivity up to some degree. In order to prevent recombination of dissociated molecules BCl3 is mixed with H2S 2) SILARC method. Advantages of this method: a) Gas cooling is helpful to split and shrink boron isotopes absorption bands. In order to achieve better selectivity BCl3 gas has to be substantially rarefied (~0.01%-5%) in mixture with carrier gas. b) Laser intensity is lower than in the first method. Some preliminary calculations of dissociation and recombination with carrier gas molecules energetics for both methods will be demonstrated Boron separation in SILARC method can be represented as multistage process: 1) Mixture of BCl3 with carrier gas is putted in reservoir 2) Gas overcooling due to expansion through Laval nozzle 3) IR multiphoton absorption by gas irradiated by specifically tuned laser field with subsequent gradual gas condensation in outlet chamber It is planned to develop software which includes these stages. This software will rely on the following available software based on quantum molecular dynamics in external quantized field: 1) WavePacket: Each particle is treated semiclassicaly based on Wigner transform method 2) Turbomole: It is based on local density methods like density of functional methods (DFT) and its improvement- coupled clusters approach (CC) to take into account quantum correlation. These models will be used to extract information concerning kinetic coefficients, and their dependence on applied external field. Information on radiative corrections to equation of state induced by laser field which take into account possible phase transition (or crossover?) can be also revealed. This mixed phase equation of state with quantum corrections will be further used in hydrodynamical simulations. Moreover results of these hydrodynamical simulations can be compared with results of CFD calculations. The first reasonable question to ask before starting the CFD simulations is whether turbulent effects are significant or not, and how to model turbulence? The questions of laser beam parameters and outlet chamber geometry which are most optimal to make all gas volume irradiated is also discussed. Relationship between enrichment factor and stagnation pressure and temperature based on experimental data is also reported.

  • PDF

The resistance rate of anti-tuberculosis drug isolated from initial tuberculosis patients at a general hospital in Daejeon area (대전지역 일개 종합병원 초진결핵 환자들로부터 분리(分離)된 결핵균(結核菌)의 약제(藥劑) 내성률(耐性率))

  • Lee, Dong-Hoon;Kim, Sang-Ha;Kim, Young-Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5012-5018
    • /
    • 2011
  • According to the nationwide survey of tuberculosis from 1965 to 1995, the incidence and drug resistance rate of tuberculosis have been decreased in Korea, but the prevalence of multidrug resistance of Mycobacterium tuberculosis is still a serious problem. The purpose of this study is to investigate the drug resistance rate and pattern of tuberculosis in Daejeon from 2001 to 2008. Of the total 581cases where the drug susceptibility test was performed, resistance to at least one anti-TB drug was found in 104 cases(17.9%) of these, 68(11.7%) were resistant to at least INH and 41(7.1%) were resistant to at least RFP. Single-drug resistance was found for isolates from 37(6.4%) ; 18(3.1%) of these were resistant to INH and 5(0.9%) to RFP. Multidrug resistance, where TB was resistant to at least isoniazid and refampin, was found in 35 cases(6.0%). and Factors associated with MDR-TB included age under 40-60.The drug-resistance rate of pulmonary TB, especially MDR-TB, is higher in the initial treated patients at a private referral hospital than in those in the pubulic sector. Initial drug resistance is common and the drug susceptibility test is informative for pulmonary TB patients who have not received previous TB treatment. The need for an improved control program, coupled with early diagnosis of MDR-TB, to reduce the spread and development of resistance. Multidrug resistance rate is still problem in korea. Efforts to decrease multidrug resistance rate either independently or in cooperation with the pubulic sector will be needed.

Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰)

  • Choi, Yong;Kim, Jong-Ho;Kim, Joon-Young;Im, Ki-Chun;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Joo, Koan-Sik;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.82-93
    • /
    • 2000
  • Purpose: We characterized the signals obtained from the components of a small gamma camera using Nal(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. Materials and Methods: The small gamma camera system consists of a Nal(Tl) crystal ($60{\times}60{\times}6mm^3$) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y -). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. Results: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately $8{\times}10^3$ counts/sec/${\mu}Ci$. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and $^{99m}Tc$ point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing $2{\sim}7mm$ diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.

  • PDF

Analysis of Micronuclei and Its Association with Genetic Polymorphisms in Hospital Workers Exposed to Ethylene Oxide (에틸렌옥사이드(Ethylene oxide)에 노출된 병원 근로자들의 소핵 빈도와 유전적 감수성 지표와의 연관성)

  • Lee, Sun-Yeong;Kim, Yang-Jee;Choi, Young-Joo;Lee, Joong-Won;Lee, Young-Hyun;Shin, Mi-Yeon;Kim, Won;Yoon, Chung-Sik;Kim, Sung-Kyoon;Chung, Hai-Won
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.6
    • /
    • pp.429-439
    • /
    • 2011
  • Objectives: Ethylene oxide (EtO) is classified as a human carcinogen, but EtO is still widely used to sterilize heat-sensitive materials in hospitals. Employees working around sterilizers are exposed to EtO after sterilization. The aim of the present study was to assess the exposure of EtO level, coupled with occupationally induced micronuclei from hospital workers. The influence of genetic polymorphisms of detoxifying genes (GSTT1 and GSTM1) and DNA repair genes (XRCC1 and XRCC3) on the frequencies of micronuclei in relation to exposure of EtO was also investigated. Methods: The study population was composed of 35 occupationally exposed workers to EtO, 18 student controls and 44 unexposed hospital controls in Korea. Exposure to EtO is measured by passive personal samplers. We analyzed the frequencies of micronuclei by performing cytokinesis-block micronucleus assay (CBMN assay) and GSTM1, GSTT1, XRCC1, and XRCC3 were also genotyped by performing polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP). Results: The frequencies of micronuclei in EtO exposure group, student controls and hospital controls were $18.00{\pm}7.73$, $10.47{\pm}7.96$ and $13.86{\pm}6.35$ respectively and their differences were statistically significant, but no significant differences according to the level of EtO were observed. There was a dose-response relationship between the frequencies of micronuclei and cumulative dose of EtO, but no significantly differences were observed. We also investigated the influence of genetic polymorphisms (GSTM1, GSTT1, XRCC1, and XRCC3) on the frequencies of micronuclei, but there were no differences in the frequencies of micronuclei by genetic polymorphisms. Conclusions: The frequencies of micronuclei in EtO exposure group was significantly higher than control groups. A dose-response relationship was found between the level of EtO exposure and the frequencies of micronuclei, but no statistically differences were observed. We also found that the frequencies of micronuclei were increased according to cumulative EtO level. There was no association of the genetic GSTM1, GSTT1, XRCC1, and XRCC3 state with the frequency of micronuclei induced by EtO exposure.

Effects of Repeated Immobilization Stress on the Renal Peripheral Benzodiazepine Receptor in Rats (반복적 부동화 스트레스가 흰쥐 신장의 말초성 benzodiazepine 수용체에 미치는 영향)

  • Park Yong Hoon;Moon Han Ku;Shin Son Moon;Lee Eun Ju;Lee Eun Sil;Ha Jeoung-Hee
    • Childhood Kidney Diseases
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 1999
  • Purpose : Several modulatory factors for renal peripheral benzodiazepine receptor (PBR) has been reported, but their physiological significance remains elusive. Tissue-specific, stress-induced down-regulation of renal PBR coupled with the pharmacological stimulation of these effects by angiotensin II suggested that physiological significance of renal PBR may be related to the pathophysiology of stress-induced hypertension. The boderline hypertensive rat (BHR) has been used extensively to study the interaction of environmental factors, such as stress and blood pressure. The BHR is the first-generation progeny of a cross between the spontaneously hypertensive rat and the control Wistar-Kyoto rat. The pathogenesis of stress induced hypertension in this model is not demonstrated well. Methods In this study, BHR (male, 150-200 g) and Sprague-Dawley (SD, male, 150-200 g) rats were treated by repeated immobilization to induce anxiety. We used plus-maze performance to observe the level of anxiety by measuring percent open crosses and percent time in open. Results : Percent open crosses and percent time in open in BHR were lower than in SD rats (P<0.05). Receptor densities of renal PBR in BHRs were significantly lower than those of SDs (P<0.05). We also observed that the renal PBR was upregulated in the repeatedly stressed (immobilization, 2 hours daily, for 2 weeks) rats, both in the BHR and SD. However, the density of renal PBR in the stressed BHR was still lower than that of stressed SD. Renal PBR has been suggested to be an important organs which Is responsible for the production of cholesterol-derived products during stress. Conrlusion : From these results, it can be summarized that the lowed density of renal PBR may be involved in the pathogeneis of stress-induced hypertension.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF