• Title/Summary/Keyword: Cross-Tension

Search Result 247, Processing Time 0.027 seconds

Improving the Performance of Hot Rolling Process through Cross Control (Cross Control 기법을 통한 열연 공정의 성능 개선)

  • Jung, Jae-Kyung;Park, Ju-Hyun;Shim, Woo-Chul;Kwon, Oh-Min;Won, Sang-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.561-563
    • /
    • 1999
  • The looper of a hot strip finishing mill is installed between each pair of stands and plays a key role to enhance the product quality of strip by controlling the tension and height of strip in each inter-stand. Though the conventional looper control has achieved the mass products of strip so far, it has difficulties not only tuning gains by means of errors which are caused by coupling effects between strip tension and looper angle both utilizing tension feedback. Therefore, the non-interactive control employing cross controller and tension feedback has been introduced in looper control system in order to overcome the coupling effects existing between tension and looper angle and track the reference tension efficiently. In this paper, we present the cross controllers which play a role to decouple reciprocal effects between tension and looper angle and show better performance.

  • PDF

Experimental Study on the Droplet Formation in a Microchannel with a Cross Junction (십자형 마이크로 채널 내에서의 액적 형성에 관한 실험적 연구)

  • Park, Jae-Hyoun;Bae, Ki-Hwa;Heo, Young-Gun;Suh, Yong-Kweon
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.2
    • /
    • pp.39-47
    • /
    • 2007
  • This paper describes an experimental study on the droplet formation and the subsequent motion in a microchannel having a cross junction. While one kind of liquid (pure water or water-surfactant mixture) is drawn into a horizontal inlet channel, the other kind (oil) is introduced through two vertical inlet channels. Due to the effect of surface tension on the interface between the two fluids, the droplets of the first fluid are formed near the cross junction. In this study, we have found that the droplet formation is affected even by slight difference in the surface tension. When the surface tension between two fluids is decreased, the droplet size is decreased in order to keep the equilibration between the pressure and the surface tension. In addition, the time interval between each of the droplet formations is decreased and the distance between droplets is also decreased when the surface tension is decreased.

Tension Control of Hot Strip Finishing Mill (열간 사상압연 공정의 장력제어)

  • 이동욱;안병준;배종일;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.322-325
    • /
    • 2002
  • We describe the looper controller design for a hot strip mill. The looper is to control the strip tension which influences on the width of the strip. It is very important to control the looper control of the hot strip mill, but difficult to control the looper, because there exists on mutual interaction among strip gauge, looper angle, and strip tension. In this paper, we present the modeling for the hot strip finishing mill to control the tension of the strip and suggest a cross control method. The cross control is a very simple method that allows non-interacting control.

  • PDF

Natural Frequencies of Beams with Step Change in Cross-Section

  • Kim, Yong-Cheul;Nam, Alexander-V.
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.46-51
    • /
    • 2004
  • Natural frequencies of the transverse vibration of beams with step change in cross-section are obtained by using the asymptotic closed form solution. This closed form solution is found by using WKB method under the assumption of slowly varying properties, such as mass, cross-section, tension etc., along the beam length. However, this solution is found to be still very accurate even in the case of large variation in cross-section and tension. Therefore, this result can be easily applied to many engineering problems.

Fatigue Strength Evaluation of Self-Piercing Riveted Al-5052 Joints (셀프 피어싱 리베팅한 Al-5052 접합부의 피로강도 평가)

  • Kang, Se Hyung;Hwang, Jae Hyun;Kim, Ho Kyung
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.1-6
    • /
    • 2015
  • Self-piercing riveting (SPR) is receiving more recognition as a possible and effective solution for joining automotive body panels and structures, particularly for aluminum parts and dissimilar parts. In this study, static strength and fatigue tests were conducted using coach-peel and cross-tension specimens with Al-5052 plates for evaluation of fatigue strength of the SPR joints. For the static experiment results, the fracture modes are classified into pull-out fracture due to influence of plastic deformation of joining area. During the fatigue tests for the coach-peel and cross-tension specimens with Al-5052, interface failure mode occurred on the top substrate close to the rivet head in the most cycle region. There were relationship between applied load amplitude $P_{amp}$ and life time of cycle N, $P_{amp}=715.5{\times}N^{-0.166}$ and $P_{amp}=1967.3{\times}N^{-0.162}$ were for the coach-peel and cross- tension specimens, respectively. The finite element analysis results for specimens were adopted for the parameters of fatigue lifetime prediction. The relation between SWT fatigue parameter and number of cycles was found to be $SWT=192.8N_f^{-0.44}$.

Fatigue Strength Evaluation of Mechanical Press Joints of Cold Rolled Steel Sheet under Cross-Tension Loading (냉간압연강 판재 기계적 접합부의 십자형 인장 하중하에서의 피로강도)

  • Kim, Jong-Bong;Kim, Taek-Young;Kang, Se-Hyung;Kim, Ho-Kyung
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.1-7
    • /
    • 2014
  • In this study, for the evaluation of the static and fatigue joining strength of the joint, the geometry of the cross-tension specimen was adopted. The specimens were produced with optimal joining force and fatigue life of the clinch joint specimens was evaluated. The material selected for use in this study was cold rolled mild steel (SPCC) with a thickness of 0.8 mm. The maximum tensile load was 708 N for the specimen with single point. The fatigue endurance limit (=42.6 N) per point approached to 6% of the maximum tensile strength at a load ratio of 0.1, suggesting that the joints are vulnerable to cross-tension loading during fatigue. Compared to equivalent stress and maximum principal stress, the SWT fatigue parameter and equivalent strain can properly predict the current experimental fatigue life. The SWT parameter can be expressed as $SWT=2497.5N^{-0.552)_f$.

An Asymptotic Solution and the Green's Function for the Transverse Vibration of Beams with Variable Properties

  • Kim, Yong-Chul
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.34-38
    • /
    • 2010
  • An analytical solution procedure for the dynamic response of beams with variable properties is developed by using an asymptotic solution and the Green's function. This asymptotic closed form solution is derived for the transverse vibration of beams under the assumption of slowly varying properties, such as mass, cross-section, tension etc., along the beam length. However, this solution is still found to be very accurate even in the case of large variation, such as step change in cross-section, mass, and tension. Therefore, this derived asymptotic closed form solution and the Green's function can be easily applied to find dynamic responses for various kind of beam vibration problems.

The Tension Control by using CDM of the Full Stand Hot Finishing Mill

  • Lee, Dong-Wook;Ahn, Byoung-Joon;Kim, Young-Ho;Lee, Man-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.67.1-67
    • /
    • 2002
  • We describe the looper controller design for a hot strip mill. The looper is to control the strip tension which influences on the width of the strip. It is very important to control the looper control of the hot strip mill, but difficult to control the looper, because there exists on mutual interaction among strip gauge, looper angle, and strip tension. In this paper, we present the modeling for the hot strip finishing mill to control the tension of the strip and suggest a cross control method of full-stand hot strip finishing mill. The cross control is a very simple method that allows non-interacting control.

  • PDF

Natural Frequencies and Mode Shapes of Beams with Step Change in Cross-Section

  • Kim, Yong-C.;Nam, Alexander V.
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.152-157
    • /
    • 2003
  • Natural frequencies of the transνerse vibration of beams with step change in cross-section are obtained by using the asymptotic closed form solution. This closed form solution is found by using WKB method under the assumption of slowly varying properties, such as mass, cross-section, tension etc., along the beam length. However, this solution is found to be still very accurate even in the case of large variation in cross-section and tension. Therefore, this result can be easily applied to many engineering problems.

  • PDF

The experimental investigation on the characteristics of the cabling tension (케이블 포설장력 특성에 대한 실험적 고찰)

  • Kim, Dong-Hun;Han, Jin-Woo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.49-53
    • /
    • 2009
  • If you are installing communications cables in the pipeline based on the kind of cable installation tension within the allowed range of the tension must be maintained. The tension of the installation affected by the cable types, cable jacketed status, cross-sectional shape of the pipeline, the substance present in the pipeline, pipeline linear, the direction of the cable is installed. Depending on the size of the cable installation tension fatal influence on the quality of communication, or, at worst, the cable can be cut. In this paper, test bed for building a pipeline and using optical cable and such cable tension was measured. Freedom of access to the pipeline used in the experiment, and installed in conjunction with the cable tension was measured. It possible for the cable installation to determine whether a duplicate, and have compared the actual measured tension value and the theoretical expression.

  • PDF