• 제목/요약/키워드: Cross laminated timber (CLT)

검색결과 35건 처리시간 0.033초

Optimized Lamina Size Maximizing Yield for Cross Laminated Timber Using Domestic Trees

  • Jeong, Gi-Young;Lee, Jun-Jae;Yeo, Hwan-Myeong;Hong, Jung-Pyo;Kim, Hyung-Kun;So, Won-Tek;Chung, Woo-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권2호
    • /
    • pp.141-148
    • /
    • 2013
  • The goal of this study was to find the optimum lamina size from red pine (Pinus densiflora) and Japanese cedar (Cryptomeria japonica) logs for the cross laminated timber (CLT) production. From visual inspection of the logs from two species, red pine log showed a larger knot and warp compared to the Japanese cedar. Different cross-sectional sizes of lamina ($110mm{\times}30mm$, $110mm{\times}40mm$, $110mm{\times}50mm$, $50mm{\times}30mm$, $30mm{\times}30mm$) from two species were analyzed for yield and grade. Regardless of the species, the optimized cross sectional size for maximizing the yield was $110mm{\times}30mm$. In grading for the different size laminas from Japanese cedar and red pine, a higher percentage of the first and second grade was found from the $110mm{\times}30mm$ lamina cut.

Evaluation of Bearing Strength of Self-Tapping Screws according to the Grain Direction of Domestic Pinus densiflora

  • LEE, In-Hwan;KIM, Keonho;SHIM, Kug-bo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제50권1호
    • /
    • pp.1-11
    • /
    • 2022
  • To evaluate the bearing strength of red pine cross-laminated timber (CLT) with self-tapping screw (STS), which is widely used as a fastener for connection in CLT building, the bearing test was conducted. Accoring to the STS's diameters (8, 10, 12 mm), the bearing test specimens with half hole were manufactured. Bearing strength was compared and reviewed in consideration of the configuration in STS and the loading direction to the grain of red pine. As a result of the bearing test on the STS's diameter, the yield bearing load increases as the larger diameter of the STS in all directions of the red pine. The bearing strength of the thread part (thread + tip) was higher than the shank part (shank + shank cutter). In compared with the directions to the grain of red pine, the bearing strength of the cross section parallel to the loading direction was the highest, and the tangent section was the lowest bearing strength. The average bearing strength of the loading direction in parallel to the grain was 23.43 MPa, which was about 45% higher than the average 16.16 MPa in perpendicular to the grain. The predicted bearing strength calculated by Eurocode (EN) and Korean Building Code (KBC)'s equation was lower than the experimental value. It is nessesary to propose the new equations of bearing strength reflected the configuration information of STS.

CLT 건축물의 외벽 및 지붕 구조체 레이어 구성 유형 분석 (Analysis of the Types of External Wall and Roof Structure Layer Composition of CLT Building)

  • 유동완;이태구
    • 한국농촌건축학회논문집
    • /
    • 제22권4호
    • /
    • pp.71-78
    • /
    • 2020
  • Today, the whole world is going through a big chaos due to the COVID-19, but paradoxically, the emergence of COVID-19 has been leading to the need for sustainable development, such as Green New Deal that can improve global warming and carbon emissions, and the need for sustainable architecture is growing bigger and bigger in the architectural field as well. The level of CLT buildings in Korea is at a very rudimentary stage, while CLT buildings remedying existing wooden buildings are getting the spotlight among European countries for sustainable architecture. This study was conducted to categorize structure layer compositions of overseas CLT buildings and analyze architectural techniques and materials applied by collecting and analyzing information about CLT structure layer compositions of overseas CLT building-related institutions, companies and cases. When classifying structure layer compositions of foreign CLT buildings depending on the roles of layers. it was revealed that exterior wall structure layers were combined and organized within a sequence of external finishing, ventilation, waterproof, board, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing, sloped roof structure layers were external finishing, ventilation, waterproof, board, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing, flat roof structure layers were external finishing, ventilation, waterproof, planking wood, external insulation, waterproof, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing.

난연특성을 가지는 EVA/Intumescent/나노클레이 복합재료 제조 및 교호집성재(Cross Laminated Timber) 적용 기술 (Preparation of EVA/Intumescent/Nano-Clay Composite with Flame Retardant Properties and Cross Laminated Timber (CLT) Application Technology)

  • 최요석;박지원;이정훈;신재호;장성욱;김현중
    • Journal of the Korean Wood Science and Technology
    • /
    • 제46권1호
    • /
    • pp.73-84
    • /
    • 2018
  • 최근 들어 늘어나고 있는 도시형 화재 사고와 건축 외장재에 따른 화재 피해 사례의 증가에 따라 난연처리기술의 중요성이 부각되고 있다. 특히, 목재를 기반으로 한 건축재료의 활용에 있어서 난연처리기술은 더욱 중요하게 평가되고 있다. Intumescent 시스템은 비할로겐계 난연처리기술의 하나로, 발포와 탄화층 형성을 통하여 난연성을 구현하는 시스템이다. 본 연구에서는 Intumescent 시스템을 적용하기 위해 Ethylene vinyl acetate (EVA)를 매트릭스로 채용하여 복합재료를 제조하였다. Intumescent 시스템의 난연특성을 강화하기 위해 나노클레이를 함께 적용하였다. Intumescent 시스템과 나노클레이 기술을 함께 적용한 복합재료를 시트상의 시험편으로 가공한 후, 이를 활용하여 표면의 난연특성이 강화된 새로운 구조의 교호집성재를 제작하였다. Intumescent 시스템을 적용한 복합재료의 연소특성 평가에서 최대 열방출량이 효과적으로 감소되는 것을 확인할 수 있었다. 표면에 부착된 구조에 따라 CLT는 두 단계에 걸친 연소 현상이 발생했다. 또한, 심부 연소 과정에서 최대 열방출률이 크게 감소하는 경향을 확인할 수 있었다. 이러한 특성은 목재의 연소과정에 있어 연소 확산지연효과가 있을 것으로 판단된다. 표면단판에 대한 난연처리기술 및 복합재료 적용 최적화 기술을 통해 보다 화재특성이 개선된 CLT 구조체 개발이 가능할 것으로 기대된다.

Seismic Reliability Assessment of Mid- and High-rise Post-tensioned CLT Shear Wall Structures

  • Sun, Xiaofeng;Li, Zheng;He, Minjuan
    • 국제초고층학회논문집
    • /
    • 제9권2호
    • /
    • pp.175-185
    • /
    • 2020
  • Currently, few studies have been conducted to comprehend the seismic reliability of post-tensioned (PT) CLT shear wall structures, due to the complexity of this kind of structural system as well as due to lack of a reliable structural model. In this paper, a set of 4-, 8-, 12-, and 16-storey benchmark PT CLT shear wall structures (PT-CLTstrs) were designed using the direct displacement-based design method, and their calibrated structural models were developed. The seismic reliability of each PT-CLTstr was assessed based on the fragility analysis and based on the response surface method (RSM), respectively. The fragility-based reliability index and the RSM-based reliability index were then compared, for each PT-CLTstr and for each seismic hazard level. Results show that the RSM-based reliabilities are slightly less than the fragility-based reliabilities. Overall, both the RSM and the fragility-based reliability method can be used as efficient approaches for assessing the seismic reliabilities of the PT-CLTstrs. For these studied mid- and high-rise benchmark PT-CLTstrs, following their fragility-based reliabilities, the 8-storey PT-CLTstr is subjected to the least seismic vulnerability; while, following their RSM-based reliabilities, the 4-storey PT-CLTstr is subjected to the least seismic vulnerability

Performance of Six-Layered Cross Laminated Timber of Fast-Growing Species Glued with Tannin Resorcinol Formaldehyde

  • Deazy Rachmi TRISATYA;Adi SANTOSO;Abdurrachman ABDURRACHMAN;Dina Alva PRASTIWI
    • Journal of the Korean Wood Science and Technology
    • /
    • 제51권2호
    • /
    • pp.81-97
    • /
    • 2023
  • The aim of this study were to evaluate tannin resorcinol formaldehyde (TRF) for the preparation of cross-laminated timbers (CLTs) made from fast-growing tree species and to analyze the physical and mechanical properties of CLTs. TRF copolymer resin was prepared by using the bark extracts of Swietenia mahagoni (L.) Jacq. It was observed that the TRF adhesive possessed less solid content (23.59%), high viscosity (11.35 poise), and high pH values (10.0) compared to the standard phenol resorcinol formaldehyde. The TRF adhesive was applied to produce CLTs with the addition of 15% tapioca and flour as an extender. The six-layered CLTs were produced from sengon (Falcataria moluccana Miq.), jabon [Anthocephalus cadamba (Roxb) Miq.], coconut (Cocos nucifera L.), and the combination of coconut-jabon and coconut-sengon wood. The analysis of variance revealed that the layer composition of CLT significantly affected the physical and mechanical properties of the beam. While the modulus of rupture met the standard, the moisture content and modulus of elasticity values did not fulfill JAS 1152-2007. All of the CLTs produced in this study demonstrated low formaldehyde emission, ranging from 0.001 mg/L to 0.003 mg/L, thereby satisfying the JAS 1152 for structural glue laminated timber.

Development of Ply-Lam Composed of Japanese Cypress Laminae and Korean Larch Plywood

  • FUJIMOTO, Yoshiyasu;TANAKA, Hiroshi;MORITA, Hideki;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제49권1호
    • /
    • pp.57-66
    • /
    • 2021
  • In recent years, the use of cross laminated timber (CLT) has been evolving. In addition, CLT manufactured with various species such as Japanese cedar has been developed to utilize the local resources in each country. However most factories in Japan produce CLT by bonding the laminae in width direction for orthogonal layers, where grain of element is perpendicular to the grain of outer layer, and this process is considered to be one of the factors that reduce productivity. A new wood based material (hereinafter referred to as Ply-lam) using wooden panel such as plywood for the orthogonal layer was developed in order to improve productivity in CLT manufacturing and improve quality. Japanese cypress lamina was used for the parallel layer, where grain of element is parallel to the grain of outer layer, of CLT and Korean larch plywood was used for the orthogonal layer, in order to effectively use Korean larch and expand the utilization of Japanese cypress. The cross-sectional construction of the Ply-lam was 5-layers 5-plies, and the dimensions were 1000 mm (width) × 150 mm (depth) × 4000 mm (length). As a performance evaluation of the manufactured Ply-lam, strength tests such as out-of-plane bending, in-plane bending, out-of-plane shearing and in-plane shearing tests were carried out. As the result of this study, Ply-lam composed of Japanese cypress lamina panels and Korean larch plywood showed very higher out-of-plane bending strength compared to the standard strength of CLT. And the result obtained in other tests seems to show a sufficiently high value.

Numerical Simulation on Disproportionate Collapse of the Tall Glulam Building under Fire Conditions

  • Zhao, Xuan;Zhang, Binsheng;Kilpatrick, Tony;Sanderson, Iain
    • 국제초고층학회논문집
    • /
    • 제10권4호
    • /
    • pp.311-321
    • /
    • 2021
  • Perception of the public to structural fires is very important because there are only a number of tall timber buildings constructed in the world. People are hesitating to accept tall timber buildings, so it is essential to ensure the first generation of tall timber buildings to a very high standard, especially fire safety. Right now, there are no specific design standards or regulations for fire design of tall timber buildings in Europe. Even though heavy timber members have better fire resistance than steel components, many conditions still need to be verified before considering the use of timber materials, e.g. fire spread, post-fire collapse, etc. This research numerically explores the structural behaviours of a tall Glulam building when one of its internal Glulam (Glued laminated timber) columns fails after sustaining a full 120-min standard fire and is removed from the established finite element building model created in SAP2000. The numerical results demonstrate that the failure and removal of the selected internal Glulam column may lead to the local failure of the adjacent CLT (Cross laminated timber) floor slabs, but will not lead to large disproportionate damage and collapse of the whole building. Here, the building is assumed to be located in Glasgow, Scotland, UK.

구조용 집성판(CLT)-콘크리트 경계면의 전단성능 평가 (Shear Performance Evaluation at the Interface Between CLT and Concrete)

  • 박금성
    • 한국공간구조학회논문집
    • /
    • 제21권3호
    • /
    • pp.35-42
    • /
    • 2021
  • An experimental study was carried out to evaluate the shear performance at the interface composed of structural laminates and concrete. The main variables are the number of CLT layers and the shape of the shear connector. The number of CLT layers consisted of 3 and 5 layers. A total of 6 test specimens for shear performance evaluation were prepared in the form of a shear connector, a direct screw type and a vertically embedded type. As a result of the experiment, similar behavior was shown in all specimens, regardless of the number of layers, including direct screw type (SC series) and vertically embedded type (VE series). The behavior at the joint surface was damaged due to the occurrence of initial shear cracks, expansion of shear groove cracks, and splaying at the interface after the maximum load.After the maximum load, the shear strength decreased gradually due to the effect of the shear connector. It can be seen that the shear strength of all specimens is determined by shear and compression stress failure of concrete at the interface of the notch joint.

경사못이 적용된 CLT-콘크리트 접합부의 하중전달능력 (Load Bearing Capacity of CLT - Concrete Connections with Inclined Screws)

  • 김경태;김종호
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.3-13
    • /
    • 2018
  • Load bearing capacity of dowel type fasteners loaded perpendicular to the shear plane is determined based on Johansen's yield theory (Johansen, 1949). In case of inclined screws whose axis is no longer perpendicular, the ultimate load of connection increases because of additional axial withdrawal capacity. To calculate load bearing capacity for inclined screws, KBC2016 and Eurocode5 provide design equations using the combination of two effects; axial and bending strength. Although their equations have been validated for a long time, there is still minimal information how to apply them for concrete-CLT joints. Since there are not many test data available, engineers have to make certain assumptions and thus results may look inconsistent in practice. In this paper, authors would like to describe the current approach and assumptions indicated by KBC2016 and Eurocode 5 and how they match the experimental results in terms of shear strength of CLT-concrete connections. To fulfill the objective, several push-out tests were performed on nine different test specimens. Each specimen has different penetration angles and depths. By analyzing load-displacement curves, the maximum shear strength, stiffness, and ductility were obtained. Shear strength values were compared with the current design codes and theoretical equations proposed in this paper. Observations on stiffness and ductility were briefly discussed.