• Title/Summary/Keyword: Cross current

Search Result 1,736, Processing Time 0.028 seconds

Switch Design of TM Type SIDO DC-DC Buck Converter for Camera Module (카메라 모듈용 TM 방식 SIDO DC-DC 벅 컨버터의 스위치 설계)

  • Choi, Hun;Lee, Dong-Keon;Jeong, Hang-Geun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.57-63
    • /
    • 2012
  • In this paper, a switch sizing method is proposed in order to prevent the cross-regulation in the TM type SIDO DC-DC buck converter. In TM type SIDO DC-DC buck converter, a DCM operation is required. In the DCM operation, the inductor peak current is larger than that in the CCM. Because of the larger inductor peak current and the added switch resistance, the voltage drop is increased, resulting in possible cross-regulation. To solve this problem, the switch resistance must be considered in sizing the switch. To simplify the calculation of the resistance, the inductor current was replaced by the average load current. Using the proposed method, TM type SIDO DC-DC buck converter for camera module was designed to provide two independent supply voltage(2.8 V and 1.8 V). The designed circuit was fabricated in a standard $0.35{\mu}m$ CMOS process. At a switching frequency of 1 MHz and a load current of 200 mA, a power effciency of 80.7% was achieved.

The Relation of Cross-sectional Residual Current and Stratification during Spring and Neap Tidal Cycle at Seokmo Channel, Han River Estuary Located at South Korea (대.소조기시 한강하구 석모수로에서 단면 잔차류와 성층간의 관계 연구)

  • Choi, Nak-Yong;Yoon, Byung-Il;Kim, Jong-Wook;Song, Jin-Il;Lim, Eun-Pyo;Woo, Seung-Bhum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.3
    • /
    • pp.149-158
    • /
    • 2012
  • This study analyzed cross-sectional variations in residual current and strengths of stratification by observing cross-sectional velocity and salinity during spring tide and neap tide, respectively, for continuous 13-hour periods at 2 observation lines at northern and southern end of Seokmo Channel, which is located west of Ganghwado. Salinity distribution of channel depends on not only neap and spring tide but also impact of salinity. The residual current component was obtained by removing $M_2$ and $M_4$ tidal components that were extracted using the least squares method on 13-hour velocity component. Cross-section of residual velocity at northern and southern end of Seokmo Channel exhibited southward residual components at channel's surface layer, but northward residual current was observed at channel's bottom layer, clearly showing a 2-layer tidal circulation between surface and bottom layers. The variation in location of appearing northward residual current according to changes in spring and neap tidal cycle and its correlation with stratification were analyzed using the Richardson number and Simpsonhunter index. At northern and southern end of Seokmo Channel, northward residual current appears in the location where Richardson number is large, Simpson-hunter index appears as a value greater than 4.

The Change of Dielectric Constant and Leakage Current of PVA (polyvinyl alchol) by Increasing Temperature and Concentration

  • Lee, Tae-Ho;Jang, Jae-Ho;Nam, Ho-Seong;Jo, Han-Na;No, Yong-Han
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.388.1-388.1
    • /
    • 2014
  • The performance of PVA(polyvinyl alchol) is better than another organic dielectric material. Therefore, PVA has been researched for organic and in-organic dielectric material. But research of changing PVA's dielectric constant and leakage current by increasing temperature and concentration was insigificant. We try to find pure PVA and cross-linked PVA's characteristic of dielectric by changing temperature and concentration. 5/10/15wt% PVA concentration (5% interval) was in progress, PVA at $100/150/200/250^{\circ}C$ ($50^{\circ}C$ interval) of experiments was conducted in relation to temperature. The higher the concentration, leakage currents decrease, and dielectric constant is increased. With regard to temperature, we could not see a big change of leakage current and dielectric constant of pure PVA until $200^{\circ}C$. However, we could see a tendency to increase significantly at $250^{\circ}C$. Also, leakage current and dielectric constant of cross-linked PVA gradually increased from at $100^{\circ}C$ to $200^{\circ}C$ and then sharply increased from at $250^{\circ}C$. We tried to find that PVA's inner bonds(hydroxyl group (OH-) lead to the results.

  • PDF

Study on the Output Current for Electrochemical Low-energy Neutrino Detector with Regards to Oxygen Concentration

  • Suda, Shoya;Ishibashi, Kenji;Riyana, Eka Sapta;Aida, Yani Nur;Nakamura, Shohei;Imahayashi, Yoichi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.373-377
    • /
    • 2016
  • Background: Experiments with small electrochemical apparatus were previously carried out for detecting low-energy neutrinos under irradiation of reactor neutrinos and under natural neutrino environment. The experimental result indicated that the output current of reactor-neutrino irradiated detector was appreciably larger than that of natural environmental one. Usual interaction cross-sections of neutrinos are quite small, so that they do not explain the experimental result at all. Materials and Methods: To understand the experimental data, we propose that some biological products may generate AV-type scalar field B0, leading to a large interaction cross-section. The output current generation is ascribed to an electrochemical process that may be assisted by weak interaction phenomena. Dissolved oxygen concentrations in the detector solution were measured in this study, for the purpose of understanding the mechanism of the detector output current generation. Results and Discussion: It was found that the time evolution of experimental output current was mostly reproduced in simulation calculation on the basis of the measured dissolved oxygen concentration. Conclusion: We mostly explained the variation of experimental data by using the electrochemical half-cell analysis model based on the DO concentration that is consistent to the experiment.

Fault Line Detection Methodology for Four Parallel Lines on the Same Tower

  • Li, Botong;Li, Yongli;Yao, Chuang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1217-1228
    • /
    • 2014
  • A method for faulted line detection of four parallel lines on the same tower is presented, based on four-summing and double-differential sequences of one terminal current. Four-summing and double-differential sequences of fault current can be calculated using a certain transformation matrix for parameter decoupling of four parallel transmission lines. According to fault boundary conditions, the amplitude and phase characteristics of four-summing and double-differential sequences of fault current is studied under conditions of different types of fault. Through the analysis of the relationship of terminal current and fault current, a novel methodology for fault line detection of four parallel transmission line on the same tower is put forward, which can pick out the fault lines no matter the fault occurs in single line or cross double lines. Simulation results validate that the methodology is correct and reliable under conditions of different load currents, transient resistances and fault locations.

A Study on the Fire Risk of High-voltage Cables for Electrical Vehicles (전기차용 고전압 케이블의 화재 위험성에 관한 연구)

  • Sin Dong Kang;Ye Jin Park;Si Hyun Kim;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.8-14
    • /
    • 2023
  • This study presents the characteristics of short circuits (SCs) caused by excessive currents in high-voltage cables used in electric vehicles and emphasizes the need to calculate the cross-sectional areas of these cables according to the SC current. Three direct current power supplies were connected in parallel to test the SC characteristics caused by excessive currents, and a timer and a magnetic contactor were used to deliver the conduction time and SC current. A circular infrared-radiation heater was used to test the temperature-dependent SC characteristics, a thermocouple was used to measure the temperature, and a shunt resistor was used to measure the current. As the SC current increased, the fusing time of the cable decreased. Additionally, a high-voltage cable (with an area of 16 mm2 ) used in electric vehicles fused when a current (approximately equal to 55 times the allowable current) flowed for 0.2 s (operating time of the protective device). When the SC current is 10 kA, the cable may fuse during the operating time of the protective device, thus creating a fire hazard. In electric vehicles, the size of the SC current increases in proportion to the capacity of the battery. Thus, the cross-sectional areas of the cables used should be calculated accordingly, and cable operations should be properly coordinated with the surrounding protective devices.

Improving the Ownership Regulation in the Broadcasting Industry (방송사업의 소유겸영규제 개선)

  • LEE, Suil
    • KDI Journal of Economic Policy
    • /
    • v.33 no.4
    • /
    • pp.85-118
    • /
    • 2011
  • This paper uses the horizontal regulation system as the base analysis framework. The study clearly defines the regulatory goals of the followings: the horizontal cross-ownership regulations on program provider (PP) and platform provider, the vertical regulation on cross-ownership between PP and platform operator, the regulation on cross-ownership of program provider by terrestrial broadcasting company, and the regulation on cross-ownership between terrestrial broadcasting company and platform provider. Then, by analyzing the conformity between goals and criteria of regulations and the adequacy of the regulation level according to regulatory purposes, this paper examines the justifiability of each regulation and extracts improvement measures that suite regulatory purposes. This analysis finds following appropriate measures: replacing the horizontal cross-ownership regulation on PP with conduct regulations, such as designating major broadcasting programs or replacing the current criterion of cross-ownership regulation from sales to the audience market share; reshaping the horizontal cross-ownership regulation on platform provider so that system operator (SO), satellite broadcaster and Internet protocol television (IPTV) operator would be applied by the same regulation based on the number of subscribers of pay television services; and discontinuing other cross-ownership regulation. In this way, the study shows that with appropriate regulations on cross-ownership of PP, there would be no need for additional regulation on vertical integration between PP and platform operator. On the other hand, given that the regulation on terrestrial broadcasting cross-ownership of PP could be justified only by regulatory purpose of the protection of the diversity of public opinions, it would be desirable to replace the current criteria of the number of PPs with the criteria of the audience market share. Lastly, the study shows that when platform operator is targeted by the cross-ownership regulation based on the number of subscribers of pay television services, the regulation on cross-ownership between terrestrial broadcasting company and platform provider should be replaced with conduct regulations, such as designating must-offer channels and major broadcasting programs.

  • PDF

Formation and Characterization of Polyvinyl Series Organic Insulating Layers (폴리비닐 계열 유기절연막 형성과 특성평가)

  • Jang Ji-Geun;Jeong Jin-Cheol;Shin Se-Jin;Kim Hee-Won;Kang Eui-Jung;Ahn Jong-Myong;Seo Dong-Gyun;Lim Yong-Gyu;Kim Min-Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.1 s.14
    • /
    • pp.39-43
    • /
    • 2006
  • The polyvinyl series organic films as gate insulators of thin film transistor(TFT) have been processed and characterized on the polyether sulphone (PES) substrates . The poly-4-vinyl phenol(PVP) and polyvinyl toluene (PVT) were used as solutes and propylene glycol monomethyl ether acetate(PGMEA) as a solvent in the formation of organic insulators. The cross-linking of organic insulators was also attempted by adding the thermosetting material, poly (melamine-co-formaldehyde) as a hardener in the compound. The electrical characteristics measured in the metal-insulator-metal (MIM) structures showed that insulating properties of PVP layers were generally superior to those of PVT layers. Among the layers of PVP series; copolymer PVP(10 wt%), 5wt% cross-linked PVP(10 wt%), copolymer PVP(20 wt%), 5 wt% cross-linked PVP(20 wt%) and 10 wt% cross-linked PVP(20 wt%), the 10 wt% cross-linked PVP(20 wt%) layer showed the lowest leakage current of 1.2 pA at ${\pm}10V$. The ms value of surface roughness and the capcitance per unit area are 2.41 and $1.76nF/cm^2$ in the case of 10 wt% cross-linked PVP(20 wt%) layer, respectively.

  • PDF

Cross Leg Flap Using Septocutaneous Flap and Cast Immobilization (중격피부 피판과 석고붕대 고정을 이용한 하지 교차 피판술)

  • Choi, Soo-Joong;Yoon, Tae-Kyung;Lee, Young-Ho;Lee, Eung-Joo;Chang, Ho-Guen;Chang, Jun-Dong
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.2
    • /
    • pp.165-174
    • /
    • 1998
  • Large soft tissue defect of the ankle and foot can present a difficult reconstructive problem to the surgeon. Local musculocutaneous, local fasciocutaneous or free flap is usually the first choice for providing soft tissue coverage. However, in certain situations, local flaps from the same leg and free flap may not be suitable. These include extensive soft tissue injury, where no suitable recipient vessels can be found, previous local fasciocutaneous flap or free flap failure. In such cases, we have utilized the septocutaneous(fasciocutaneous) branch flap of posterior tibial artery from the opposite healthy limb. We present 5 cases of cross leg flaps, which have been modernized with current understanding of vascular anatomy and current fixation technology. All cross leg flaps were based on the axial blood supply of the fasciocutanous branch of the posterior tibial artery. Cross-clamping with bowel clamp was used to create intermittent periods of ischemia. Adjacent lower extremity joints were exercised during the periods of attachment. The results have been quite encouraging. We conclude that the cross leg flap using septocutaneous flap and cast immobilization can be successfully and expeditiously used to cover defects of the ante and foot.

  • PDF

Lateral vibration control of a low-speed maglev vehicle in cross winds

  • Yau, J.D.
    • Wind and Structures
    • /
    • v.15 no.3
    • /
    • pp.263-283
    • /
    • 2012
  • This paper presents a framework of nonlinear dynamic analysis of a low-speed moving maglev (magnetically levitated) vehicle subjected to cross winds and controlled using a clipped-LQR actuator with time delay compensation. A four degrees-of-freedom (4-DOFs) maglev-vehicle equipped with an onboard PID (Proportional-Integral-Derivative) controller traveling over guideway girders was developed to regulate the electric current and control voltage. With this maglev-vehicle/guideway model, dynamic interaction analysis of a low-speed maglev vehicle with guideway girders was conducted using an iterative approach. Considering the time-delay issue of unsynchronized tuning forces in control process, a clipped-LQR actuator with time-delay compensation is developed to improve control effectiveness of lateral vibration of the running maglev vehicle in cross winds. Numerical simulations demonstrate that although the lateral response of the maglev vehicle moving in cross winds would be amplified significantly, the present clipped-LQR controller exhibits its control performance in suppressing the lateral vibration of the vehicle.