• 제목/요약/키워드: Cross current

검색결과 1,724건 처리시간 0.029초

A Fast Normalized Cross Correlation-Based Block Matching Algorithm Using Multilevel Cauchy-Schwartz Inequality

  • Song, Byung-Cheol
    • ETRI Journal
    • /
    • 제33권3호
    • /
    • pp.401-406
    • /
    • 2011
  • This paper presents a fast block-matching algorithm based on the normalized cross-correlation, where the elimination order is determined based on the gradient magnitudes of subblocks in the current macroblock. Multilevel Cauchy-Schwartz inequality is derived to skip unnecessary block-matching calculations in the proposed algorithm. Also, additional complexity reduction is achieved re-using the normalized cross correlation values for the spatially neighboring macroblock because the search areas of adjacent macroblocks are overlapped. Simulation results show that the proposed algorithm can improve the speed-up ratio up to about 3 times in comparison with the existing algorithm.

Cross-Linked PVP 게이트 유기 박막트랜지스터 (Organic Thin Film Transistors with Cross-Linked PVP Gates)

  • 장지근;오명환;장호정;김영섭;이준영;공명선;이영관
    • 마이크로전자및패키징학회지
    • /
    • 제13권1호통권38호
    • /
    • pp.37-42
    • /
    • 2006
  • 유기 박막트랜지스터(OTFTs)제작에서 PVP-게이트 절연막의 형성과 처리가 소자성능에 미치는 영향을 조사하였다. 유기 게이트 용액의 제조에서는 polyvinyl 계열의 PVP(poly-4-vinylphenol)를 용질로, PGMEA (propylene glycol monomethyl ether acetate)를 용매로 사용하였다. 또한 열경화성 수지인 poly(melamine-co-formaldehyde)를 경화제로 사용하여 유기 절연막의 cross-link를 시도하였다. MIM 시료의 전기적 절연 특성을 측정한 결과, PVP-기반 유기 절연막은 용액의 제조에서 PGMEA에 대한 PVP와 poly (melamine-co-formaldehyde)의 농도를 증가시킬수록 낮은 누설전류 특성을 나타내었다. OTFT 제작에서는 PGMEA에 대해 PVP를 20 wt%로 섞은 PVP(20 wt%) copolymer와 5 wt%와 10 wt%의 poly(melamine-co-formaldehyde)를 경화제로 추가한 cross-linked PVP(20 wt%)를 게이트 유전 재료로 사용하였다. 제작된 트랜지스터들에서 전계효과 이동도는 5 wt % cross-linked PVP(20 wt%) 소자에서 $0.31cm^2/Vs$로, 그리고 전류 점멸비는 10 wt% cross-linked PVP(20 wt%) 소자에서 $1.92{\times}10^5$으로 가장 높게 나타났다.

  • PDF

지상변압기의 단락보호장치 특성연구 (Characteristics of Short-Circuit Protector in Pad-Mounted Transformer)

  • 김광화;이우영;선종호;김동명;김상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1350-1352
    • /
    • 1995
  • This paper discribed the characteristic of I-t cross-over-point between current limited-fuse and explusion fuse(Bay-O-Net Fuse) and fuse protection in pad-mounted transformer that was generated internal faults and the short circuit of secondary side(load side). In the I-t cross-over-point, current limited fuse was melted when transient recovery voltage was raised rapidly.

  • PDF

과전류에 의해 용단된 소선의 특성해석에 관한 연구 (A Study on the Characteristics Analysis of Strands Melted by Over Current)

  • 최충석;김향곤;김동욱
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.60-65
    • /
    • 2004
  • The PVC insulated flexible cords are used mainly as power supply cords of electric appliance. This electric wire is a stranded wire consisted of dozens of strands. In case stranded wires are disconnected by mechanical stress, it weakens electrically. Finally, the over current flows through stranded wires, and electrical fire occurs. In this study, we analyzed the melting properties of strands by over current, such as melting process, melting current and melting time. And we analyzed that quantity of heat for melting, a cross sectional structure, and surface structure by optical microscope and SEM. As analysis results, melting time decreased as melting current increased. And quantity of heat for melting was low, too. From the cross sectional structure of melted wire, when a melting current low and melting time long, it was found that the dendrite structure grew. However, the dendrite structure is hard to grow because growing time is not enough when a melting current high and melting time short.

Plasmonic Color Filter with Robustness Against Cross Talk for Compact Imaging Applications

  • Cho, Hyo Jong;Do, Yun Seon
    • Current Optics and Photonics
    • /
    • 제4권1호
    • /
    • pp.16-22
    • /
    • 2020
  • In high resolution imaging devices, smaller aperture in the color filter causes cross talk which provides incorrect information. Plasmonic color filters (PCFs) have been reported as an alternative of the conventional color resist based-color filter (CRCF) and many studies on PCFs demonstrated the filtering function by PCFs with a sub-micron size. In this work, we investigated the cross talk performance of PCFs compared to CRCFs. The effect of cross talk over distance from the filter were measured for each filter. Despite poorer spectral filtering characteristics, PCFs were more robust against cross talk than CRCFs. Also, the further away from the filter, the more cross talk appeared. As a result, PCFs showed less cross talk than CRCFs at about 82% of the results measured at a distance of 2~10 ㎛. This study will help to make practical use of PCFs in high-resolution imaging applications.

입방정질화붕소입자 전착지석에 의한 전해디버링 시스템 (Electrochemical Deburring System by the Electroplated CBN Wheel)

  • 최인규;김정두
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.19-23
    • /
    • 1996
  • Deburring and edge finishing technology as the last process of machining operation is required for manufacturing of advanced procesion components, duburring has treated as a difficult problem on going tothe highefficency, automation in the FMS. Removal of butt with various shapes, dimensions and properties coultn't has a standard and has depended on manual treatment. Especially, deburring for cross hole inside owing to passing through out perpendicular to a main hole is more difficult, the electrolytic method is proper as its solution at practical aspects. Therefore, for the high effciency and automation of intermal deburring in the cross hole, development of electrolytic debutting technology is needed. So, the new process in the burr treatment is supposed. In this study, in the eliminating burr inside cross hole, the principle and machining performances of electrochemical deburring by Cubic-Boron-Nitrade abrasive electroplate wheel are investigated, Design and manufacture of CBN electroplated wheel and analysis of characteristics with electrolytic debutting are achieved. Also deburring efficiency and electrolytic performance for cross hole were examined according to electrolytic current and electrolytic deburring condition corresponding to acquired edge quality was found out.

  • PDF

고온초전도 테이프를 이용한 다단 전류 도입선의 최적설계 (Optimal Design of Multi-Step Current Leads Using HTS Tapes)

  • 김민수;나필선;설승윤
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.84-88
    • /
    • 2001
  • The optimum cross-sectional area Profile of gas-cooled high-temperature superconductor (HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant safety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-step HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-step current leads are discussed.

  • PDF

EMTP를 이용한 지중 송전 케이블의 시스 순환전류 분석 (EMTP-Analysis of Sheath Circulating Current on Underground Transmission Cables)

  • 하체웅;김정년;이수길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.213-215
    • /
    • 2001
  • This paper describes an improved analysis method for sheath circulating current on three-underground transmission cables using EMTP(Electromagnetic Transient Program). Author studied diversely the sheath circulating current on three-underground cables depending on the various length rate, the phase arrangement, and the grounding resistance of the sheath in the cross-bonded section. It was clear that very large circulating current is generated in cable systems due to unbalanced length rate and phase arrangement in the cross-bonded section. The analysing method for two or more underground cables will be really Improved for cable system utility.

  • PDF

다회선 지중송전 케이블에서의 EMTP를 이용한 시스 순환전류 분석 (Analysis of Sheath Circulating Current on Multi-underground Transmission Cables using EMTP)

  • 하체웅;김정년;이수길;김동욱;이종범;강지원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권10호
    • /
    • pp.510-517
    • /
    • 2002
  • The use of underground transmission cables has continuously increased in densely inhabited urban and suburban area. Due to a increasing demand of underground cables, two or more circuits are installed in parallel for several kilometers. It, however, has not been realized that the sheath circulating current is generated in the system where a large number of cables are laid in the same route. In this paper, sheath circulating current is analyzed by the EMTP and compared with the measured values. Unbalance arrangement of cables or cross-bonding length causes a significant effect on the magnitude of the sheath current. Sheath circulating current could be greatly reduced by the symmetrical configuration of cables and installation of the impedance reduction system. Especially, with the impedance system of 1Ω installed, the sheath circulating current is reduced by 85.7%.

임펄스전류에 의한 배전용 ZnO 피뢰기 소자의 열화특성 (Deterioration Characteristics of ZnO Surge Arrester Blocks for Power Distribution Systems Due to Impulse Currents)

  • 이복희;조성철;양순만
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.79-86
    • /
    • 2013
  • In order to analyze the electrical performance of ZnO surge arresters stressed by the combined DC and AC voltages that are generated in DC/AC converter systems, the leakage current properties of ZnO surge arrester blocks deteriorated by impulse currents were investigated. The test specimens were deteriorated by the 8/$20{\mu}s$ impulse current of 2.5kA and the leakage currents flowing into the deteriorated zinc oxide(ZnO) arrester blocks subjected to the combined DC and power frequency AC voltages are measured. As a result, the leakage currents flowing through deteriorated ZnO surge arrester blocks were higher than those flowing through the fine ZnO surge arrester blocks and the larger the injection number of 8/$20{\mu}s$ impulse current of 2.5kA is, the greater the leakage current is. The leakage current-voltage curves(I-V curves) of the fine and deteriorated ZnO surge arrester blocks stressed by the combined DC and AC voltages show significant difference in the low conduction region. Also the cross-over phenomenon is observed at the voltage close to the knee of conduction on plots of I-V curves.