• Title/Summary/Keyword: Cross Tensile Test

Search Result 197, Processing Time 0.023 seconds

Investigation of Radial Distributions of Tangential Strains and of Moisture Contents within a Log Cross Section by Circumferential Slices

  • Choi, Jun-Ho;Lee, Nam-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.20-28
    • /
    • 2008
  • This study was carried out to provide the so-called circumferential slicing method for investigating radial distributions of the tangential strains and of moisture contents within the log cross section (LC) of Kalopanax pictus during indoor drying it. While the heartwood showed an almost uniform moisture content distribution in the range of about 50~55% in case of the green wood, it has gradually decreased toward the outer side, showing about 19% of moisture content difference from the innermost slice. Although the moisture gradient along the radial direction has gradually become gentle as drying progresses, the sapwood of the outer side represented the moisture contents below the fiber saturation point after 24 hours of drying while the heartwood in the inner part showed the moisture contents higher than the fiber saturation point. The pith side was laid under the tensile stress after 24 hours of drying, and then gradually decreasing toward the bark side, and showed the distribution being switched again to the tensile stress on the bark side. As the drying has progressed, this trend got more intensified, and finally showed the U-shaped distribution model after 48 hours of drying. The circumferential slice test is considered to be suitable in quantitatively determining the tangential strains and moisture content within a LC.

Study of the Effect of Loading Path on the Strain and Mechanical Properties of Aluminum with Flat and Groove Rolling Experiment (순수 알루미늄의 판재압연 및 공형압연시 가공경로에 따른 변형분포와 기계적 성질의 예측)

  • Kim, S.I.;Byon, S.M.
    • Transactions of Materials Processing
    • /
    • v.17 no.6
    • /
    • pp.420-428
    • /
    • 2008
  • The effect of loading path changes on the strain and mechanical properties of a commercial pure aluminum was studied using flat rolling and groove rolling. Material during flat rolling undergoes a continuous monotonic compressive loading, while one during groove rolling experiences a series of cross compressive loading. Four-pass flat rolling and groove rolling experiment are designed such that the aluminum undergoes the same amount of the strain at each pass. The rolling experiment was performed at room temperatures. Specimens for tensile test are fabricated from the plate and bar rolled. In addition, the strain distribution for the plate and bar cold rolled specimens is also calculated by finite element method. The results reveal that differences of loading path attributed by monotonic loading(flat rolling) and cross loading(groove rolling) significantly influence the mechanical properties such as yield stress, ultimate tensile stress, strain hardening and elongation. It is clear that the different loading path can give raise to change the deformation history, although it is deformed with same amount of strain for same material.

A Study on the Alternative Method for Weathering Test of Military Coated Fabrics (군용 도포직물의 내후성시험 대체에 대한 연구)

  • Son, Chanyoung
    • Journal of Korean Society for Quality Management
    • /
    • v.44 no.3
    • /
    • pp.509-526
    • /
    • 2016
  • Purpose: We would like to find the alternative method for the weathering test on rubber coated fabrics and adhesive-coated fabrics for the military products, KS M 0706 (Sunshine carbon arc) to KS M ISO 4892-2 (Xenon arc). Methods: We measured the tensile strength of adhesive-coated fabrics and adhesive products treated with sunshine carbon arc and xenon arc during 100, 150 and 200 hours, respectively. All of the results were treated with statistical test, ANOVA method. We also validate the surface modifications caused by treatment method and time by using FT-IR ATR and, SEM. Results: In case of the thick adhesive-coated fabrics (app. 1 mm), there was no distinctive difference on tensile strength by treatment method and time. In case of the thin mask hood (app. 0.22 mm) and TENT (app. 0.5 mm), there was distinctive difference on tensile strength. Especially, carbon arc showed a huge lowering properties. We could validate the curing from light and moisture, and the functional group change from cross-linking and oxidation using FT-IR ATR. In case of IBS, there was a surface cracks on SEM images. In case of mask hood, there was no distinctive differences, except for a particle falling from decreased affinity between rubber and particles caused by carbon arc. Conclusion: We concluded that there was no problems for changing xenon arc weathering test with same treatment time on IBS, KM7, K21 and adhesive products. In case of TENT and mask hood, there was a difference in tensile strength in accordance with the change of the treated time and method.

Effect of Specimen Geometry on Bending and Tensile Strength of Material Used in Dissimilar Joints (이종 접합재의 굽힘 및 인장강도에 미치는 시험편 형상의 효과)

  • Hur, Jang-Wook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.341-346
    • /
    • 2010
  • The effect of specimen geometry on the bending and tensile strengths of dissimilar joints ($\beta-Si_3N_4/S45C$) with copper interlayers was evaluated. The average bending strength of specimens with circular cross sections was higher than that of specimens with rectangular cross sections. The crack initiation stress ($\sigma_i$) was successfully determined by the acoustic emission (AE) method and was approximately 60~80% of the bending strength. The residual stresses near the interfaces on the ceramic side were measured by X-ray diffraction before conducting the bending test. The bending strength and the crack initiation stress decreased with an increase in the residual stresses. The effect of the bending strain component was evaluated by the tensile testing; the tensile strength decreased with an increase in the bending strain component and was approximately 80% of the bending strength.

Experimental Study on Tensile Test Method of Pipe with Jig (파이프의 지그 삽입 인장시험법에 대한 실험적 연구)

  • Park, Jin-Gun;Song, Hyun-Jung;Jin, Da-Jeong;Kim, Ji-Hoon;Cho, Hae-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.5
    • /
    • pp.28-33
    • /
    • 2022
  • A pipe is a hollow, long-form part that is primarily used to transport fluids, such as liquids or gases. Pipes are used in a range of applications in different fields from mechanical purposes to architecture and electrical uses. Despite the significance owing to various usability of pipes, few studies have been conducted using the physical property test method. The tensile test is widely used as a method to check the physical properties of the pipe. The existing pipe tension test contains the possibility to cause errors, which are fractures outside the gauge distance and cross-sectional deformation of the pipe. In this study, a novel pipe tension test method using a jig is presented and pipes with various materials are tested. It is expected that the proposed method can reduce errors that occur in conventional pipes and also obtain more accurate values to enable more efficient testing.

The Influence of Water Environment on the Mechanical Properties of Carbon/Epoxy Reinforced Composite Materials (탄소섬유강화형 복합재료의 기계적 성질에 미치는 수환경의 영향)

  • 김귀식;박경석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.2
    • /
    • pp.52-59
    • /
    • 1993
  • This study is investigated of tensile and fatigue strength for advanced composite materials under hygrothermal environment. The materials used are two types of Carbon/Epoxy reinforced composite materials i.e., 13$0^{\circ}C$ cure-type composite T-1/347, and 18$0^{\circ}C$ cure-type MM-1/982X. These are composed by cross-ply laminates. Test condition is the distilled water of 8$0^{\circ}C$. The separate absorption contents estimated by the Fick's diffusion rule are similar to the experiment results. The tensile strength of T-1/347 wet specimens more increased than that of dry ones, but that of MM-1/982X decreased. The fatigue strengthes of both T-1/347 and MM-1/982X wet specimen more decreased than those of dry specimens.

  • PDF

Tensile bond strength between auto-polymerized acrylic resin and acrylic denture teeth treated with MF-MA solution

  • Thongrakard, Ticha;Wiwatwarrapan, Chairat
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.4
    • /
    • pp.285-289
    • /
    • 2016
  • PURPOSE. This study evaluated the effect of chemical surface treatment using methyl formate-methyl acetate (MF-MA) solution on the tensile bond strength between acrylic denture teeth and auto-polymerized acrylic resin. MATERIALS AND METHODS. Seventy maxillary central incisor acrylic denture teeth for each of three different brands (Yamahachi New Ace; Major Dent; Cosmo HXL) were embedded with incisal edge downwards in auto-polymerized resin in polyethylene pipes and ground with silicone carbide paper on their ridge lap surfaces. The teeth of each brand were divided into seven groups (n=10): no surface treatment (control group), MF-MA solution at a ratio of 25:75 (v/v) for 15 seconds, 30 seconds, 60 seconds, 120 seconds, 180 seconds, and MMA for 180 seconds. Auto-polymerized acrylic resin (Unifast Trad) was applied to the ground surface and polymerized in a pressure cooker. A tensile strength test was performed with a universal testing machine. Statistical analysis of the results was performed using two-way analysis of variance (ANOVA) and post-hoc Dunnett T3 test (${\alpha}$=.05). RESULTS. The surface treatment groups had significantly higher mean tensile bond strengths compared with the control group (P<.05) when compared within the same brand. Among the surface treatment groups of each brand, there were no significantly different tensile bond strengths between the MF-MA groups and the MMA 180 second group (P>.05), except for the Yamahachi New Ace MF-MA 180-second group (P<.05). CONCLUSION. 15-second MF-MA solution can be an alternative chemical surface treatment for repairing a denture base and rebonding acrylic denture teeth with auto-polymerized acrylic resin, for both conventional and cross-linked teeth.

Comparison of polymer-based temporary crown and fixed partial denture materials by diametral tensile strength

  • Ha, Seung-Ryong;Yang, Jae-Ho;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.14-17
    • /
    • 2010
  • PURPOSE. The purpose of this study was to investigate the diametral tensile strength of polymer-based temporary crown and fixed partial denture (FPD) materials, and the change of the diametral tensile strength with time. MATERIAL AND METHODS. One monomethacrylate-based temporary crown and FPD material (Trim) and three dimethacrylate-based ones (Protemp 3 Garant, Temphase, Luxtemp) were investigated. 20 specimens (${\phi}\;4\;mm\;{\times}\;6\;mm$) were fabricated and randomly divided into two groups (Group I: Immediately, Group II: 1 hour) according to the measurement time after completion of mixing. Universal Testing Machine was used to load the specimens at a cross-head speed of 0.5 mm/min. The data were analyzed using one-way ANOVA, the multiple comparison Scheff$\acute{e}$ test and independent sample t test ($\alpha\;=\;0.05$). RESULTS. Trim showed severe permanent deformation without an obvious fracture during loading at both times. There were statistically significant differences among the dimethacrylate-based materials. The dimethacrylate-based materials presented an increase in strength from 5 minutes to 1 hour and were as follows: Protemp 3 Garant (23.16 - 37.6 MPa), Temphase (22.27 - 28.08 MPa), Luxatemp (14.46 - 20.59 MPa). Protemp 3 Garant showed the highest value. CONCLUSION. The dimethacrylate-based temporary materials tested were stronger in diametral tensile strength than the monomethacrylate-based one. The diametral tensile strength of the materials investigated increased with time.

Improvement of R-value in Al-Mg-Si-Cu Alloy Sheets by Cross Rolling (크로스 압연에 의한 Al-Mg-Si-Cu 합금 판재의 소성변형비의 향상)

  • Lee, Kwang-jin;Jeon, Jae-yeol;Woo, Kee-do
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.6
    • /
    • pp.488-492
    • /
    • 2011
  • Heat-treatable Al-Mg-Si-Cu alloy sheets, which are expected to have a growing demand, were fabricated by Cross rolling to improve their formability. The mechanical properties and texture of the sheets after the final annealing process were investigated by a tensile test, EBSD and XRD analysis. The grain size of the cross-rolled sheets was remarkably decreased compared to conventional rolled sheets, and the R-value of the cross-rolled sheets was notably increased by about one and a half times that of the conventional rolled sheet. Cube{001}<100> and cubic system orientations were strongly developed in conventional rolled sheets. However, randomized textures were formed in the cross-rolled sheets without specific texture. It is thought that much shear deformation was induced during the cross rolling. The results show that the cross rolling method is effective for improving the R-value of aluminum alloys sheets and their grain refinement. As a result, it is considered that cross rolling is effective for improving formability.

Experimental Study on GFRP Reinforcing Bars with Hollow Section (중공형 GFRP 보강근의 인장성능 실험연구)

  • You, Young-Jun;Park, Ki-Tae;Seo, Dong-Woo;Hwang, Ji-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Fiber-reinforced polymer (FRP) has been generally accepted by civil engineers as an alternative for steel reinforcing bars (rebar) due to its advantageous specific tensile strength and non-corrosiveness. Even though some glass fiber reinforced polymer (GFRP) rebars are available on a market, GFRP is still somewhat uncompetitive over steel rebar due to their high cost and relatively low elastic modulus, and brittle failure characteristic. If the price of component materials of GFRP rebar is not reduced, it would be another solution to increase the performance of each material to the highest degree. The tensile strength generally decreases with increasing diameter of FRP rebar. One of the reasons is that only fibers except for fibers in center resist the external force due to the lack of force transfer and the deformation of only outer fibers by gripping system. Eliminating fibers in the center, which do not play an aimed role fully, are helpful to reduce the price and finally FRP rebar would be optimized over the price. In this study, the effect of the hollow section in a cross-section of a GFRP rebar was investigated. A GFRP rebar with 19 mm diameter was selected and an analysis was performed for the tensile test results. Parameter was the ratio of hollow section over solid cross-section. Four kinds of hollow sections were planned. A total of 27 specimens, six specimens for each hollow section and three specimens with a solid cross-section were manufactured and tested. The change by the ratio of hollow section over solid cross-section was analyzed and an optimized cross-section design was proposed.