• 제목/요약/키워드: Cross Correlation Function

검색결과 366건 처리시간 0.03초

단위 충격 응답함수를 이용한 원형관 시스템의 주출감지 연구 (Leak Detection of Circular Piping Systems by Using Unit Impulse Response Function Analysis)

  • 전오성;윤병옥;김창호
    • 소음진동
    • /
    • 제4권3호
    • /
    • pp.337-343
    • /
    • 1994
  • A method of the leak detection from the pipe system by using accelerometer is proposed. The signal detected from accelerometer is proved experimentally to be a dispersive wave. Based on the experiments, a method using the narrow band pass filter and the unit impulse response function is analyzed. The method uses the characteristics of the unit impulse response function, that the function is available evenin the narrow band signal because, unlike the cross correlation, it is normalized by the auto spectrum. The accelerometer is quite easier to use than the hydrophone in adapting to the pipe system.

  • PDF

The association of perfluoroalkyl substances (PFAS) exposure and kidney function in Korean adolescents using data from Korean National Environmental Health Survey (KoNEHS) cycle 4 (2018-2020): a cross-sectional study

  • Jisuk Yun;Eun-Chul Jang;Soon-Chan Kwon;Young-Sun Min;Yong-Jin Lee
    • Annals of Occupational and Environmental Medicine
    • /
    • 제35권
    • /
    • pp.5.1-5.14
    • /
    • 2023
  • Background: Perfluoroalkyl substances (PFAS) are chemicals widely used in various products in everyday life. Due to its unique strong binding force, the half-life of PFAS is very long, so bioaccumulation and toxicity to the human body are long-standing concerns. In particular, effects on kidney function have recently emerged and there are no studies on the effect of PFAS on kidney function through epidemiological investigations in Korea. From 2018 to 2020, the Korean National Environmental Health Survey (KoNEHS) cycle 4, conducted an epidemiological investigation on the blood concentration of PFAS for the first time in Korea. Based on this data, the relationship between PFAS blood concentration and kidney function was analyzed for adolescents. Methods: We investigated 5 types of PFAS and their total blood concentration in 811 middle and high school students, living in Korea and included in KoNEHS cycle 4, and tried to find changes in kidney function in relation to PFAS concentration. After dividing the concentration of each of the 5 PFAS and the total concentration into quartiles, multivariable linear regression was performed to assess the correlation with kidney function. The bedside Schwartz equation was used as an indicator of kidney function. Results: As a result of multivariable linear regression, when observing a change in kidney function according to the increase in the concentration of each of the 5 PFAS and their total, a significant decrease in kidney function was confirmed in some or all quartiles. Conclusions: In this cross-sectional study of Korean adolescents based on KoNEHS data, a negative correlation between serum PFAS concentration and kidney function was found. A well-designed longitudinal study and continuous follow-up are necessary.

배관-유체 연성진동을 이용한 누수지점 탐지알고리듬 개발연구 (An Algorithm for Leak Locating using Coupled Vibration of Pipe-Water)

  • Lee, Yeong-Seop;Yun, Dong-Jin
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.985-990
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband noise from a leak location and can be propagated to both directions of water pipes. This sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than 300m.

  • PDF

배관-유체 연성진동을 이용한 누수지점 탐지 알고리듬 개발 연구 (An Algorithm for Leak Locating using Coupled Vibration of Pipe-Fluid)

  • 이영섭;윤동진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.798-803
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband sound from a leak location and this sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than 300m.

  • PDF

시간지연 추정을 통한 누수위치 식별 연구 (Time Delay Estimation for the Identification of Leak Location)

  • 이영섭;윤동진;김치엽
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.327-332
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband noise from a leak location and can be propagated to both directions of water pipes. This sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than loom.

  • PDF

자동차 환경에서 TDOA를 이용한 화자위치추정 방법 (On the speaker's position estimation using TDOA algorithm in vehicle environments)

  • 이상헌;최홍섭
    • 디지털콘텐츠학회 논문지
    • /
    • 제17권2호
    • /
    • pp.71-79
    • /
    • 2016
  • 본 논문에서는 차량 내부 환경에서 음성인식 성능을 향상시켜 안정적인 차량 제어를 위한 방법으로 사용하는 음원 위치추정방법의 성능 비교와 개선 방법을 제안하였다. 일반적으로 음원 위치추정에는 TDOA알고리즘을 사용하는데 여기에는 시간영역에서 상호상관함수를 이용하는 방법과, 주파수 영역에서 계산하는 GCC-PHAT 방법이 있다. 이중 GCC-PHAT 방법은 상호상관함수보다 반향과 잡음에 강한 특성을 보인다고 알려져 있다. 본 연구에서는 반향과 잡음이 많은 차량 환경에서 위 두 방법의 성능을 비교하고 추가로 미디언 필터 사용을 제안하여 음원위치 추정 성능과 시스템의 안정성을 나타내는 지표로 사용하는 분산값이 모두 향상됨을 확인하였다. 실험결과에서 음성을 사용한 실험에서는 두 방법의 성능 차이가 거의 없지만, 노래신호를 사용한 음원위치 추정에서는 GCC-PHAT 방법이 상호상관함수에 비해 인식률이 10% 우수함을 확인하였다. 또한 미디언 필터를 추가한 경우에는 상호상관함수 방법의 인식률을 최고 11%까지 향상시킬 수 있었고 분산값에서도 두 방법 모두 안정적인 성능을 보여주었다.

운동중의 임피던스 신호에서 상호상관 관계를 이용한 특성점의 검출 (Delection of Distinctive Points in Impedance Cardiogram during Exercise by Cross-Correlation Method)

  • 오인식;송철규;김덕원;차일환
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 추계학술대회
    • /
    • pp.93-95
    • /
    • 1991
  • As the ensemble averaged dZ/dt signal during exercise is smoothed, it is difficult to find the distinctive marks. The cross correlation function was made use of estmating these marks. LVET was calculated based on the calculated parameters of the characteristic points. For the accuracy validation, LVET calculated by hand, by the ensemble average and the cross correl at ion were compared.

  • PDF

PSP를 이용한 압력측정에서의 상관법에 의한 이미지 등록 (Correlation Based Image Registration for Pressure Sensitive Paint)

  • 박상현;성형진
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.63-66
    • /
    • 2003
  • A new algorithm, CBIR (Correlation Based Image Registration) was proposed to improve the resolution of image registration for PSP (Pressure Sensitive Paint). The local displacement vectors were obtained by finding the displacement which maximizes the cross-correlation between two interrogation windows of 'wind-off' and 'wind-on' images. A recursive multigrid processing was employed to increase the non-linear spatial resolutions. The variations of image were precisely measured without identifying the control points.

  • PDF

PSP 압력측정을 위한 상관법에 의한 이미지 등록 (Correlation-Based Image Registration for Pressure Measurements Using Pressure-Sensitive Paint)

  • 박상현;성형진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1778-1782
    • /
    • 2004
  • A new algorithm, CBIR (Correlation-Based Image Registration) was proposed to improve the resolution of image registration for PSP (Pressure-Sensitive Paint). The local displacement vectors were obtained by finding the displacement which maximizes the cross-correlation between two interrogation windows of 'wind-off' and 'wind-on' images. A recursive multigrid processing was employed to increase the non-linear spatial resolutions. The variations of image were precisely measured without identifying the control points.

  • PDF

Effect of land use and urbanization on groundwater recharge in metropolitan area: time series analysis of groundwater level data

  • Chae, Gi-Tak;Yun, Seong-Taek;Kim, Dong-Seung;Choi, Hyeon-Su
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.113-114
    • /
    • 2004
  • In order to classify the groundwater recharge characteristics in an urban area, a time series analysis of groundwater level data was performed. For this study, the daily groundwater level data from 35 monitoring wells were collected for 3 years (Fig. 1). The use of the cross-correlation function (CCF), one of the time series analysis, showed both the close relationship between rainfall and groundwater level change and the lag time (delay time) of groundwater level fluctuation after a rainfall event. Based on the result of CCF, monitored wells were classified into two major groups. Group I wells (n=10) showed a fast response of groundwater level change to rainfall event, with a delay time of maximum correlation between rainfall and groundwater level near 1 to 7 days. On the other hand, the delay time of 17-68 days was observed from Group II wells (n=25) (Fig. 1). The fast response in Group I wells is possibly caused by the change of hydraulic pressure of bedrock aquifer due to the rainfall recharge, rather than the direct response to rainfall recharge.

  • PDF