• Title/Summary/Keyword: Cross Bar

Search Result 276, Processing Time 0.028 seconds

Cyclic Loading Test for Beam-to-Column Connections of Concrete Encased CFT Column (콘크리트피복충전 각형강관 기둥-보 접합부의 주기하중 실험)

  • Park, Hong Gun;Lee, Ho Jun;Park, Sung Soon;Kim, Sung Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.55-68
    • /
    • 2014
  • In this study, the beam-to column connections of concrete-encased-and-filled steel tube columns were tested under cyclic loading. Two specimens using steel beams and two specimens using precast concrete beams were tested. The dimension of the column cross section was $670mm{\pm}670mm$. The beam depths were 488mm and 588mm for the steel beams and 700mm for the precast concrete beams. The longitudinal bar ratios of the precast concrete beams were 1.1% and 1.5%. For the connections to the steel beams, continuity plates were used in the tube columns. For the connections to the PC beams, couplers were used for beam re-bar connections. The test results showed that except for a specimen, deformation capacities of the specimens were greater than 4% rotation angle, which is the requirement for the Special Moment Frame. Particularly, specimens using precast concrete beam showed excellent performances in the strength, deformation, and energy dissipation.

Discharging Performance in Length of Hard Labyrinth and Pressure of Cylinder Type Drip Irrigation Hose (원통형 점적기의 압력과 경질미로의 길이에 따른 토출 특성)

  • Kim, Jin Hyun;Woo, Man Ho;Kim, Dong Eok
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.103-109
    • /
    • 2018
  • The performance of drip irrigation devices depends on flow uniformity related to the function of pressure compensation. The flow uniformity can be secured when the internal fluid pressures at the positions of the flow holes are maintained uniformly. The pressure compensation effect of the drip irrigation devices can be optimized with the combination of soft silicon and labyrinth structures. However, for a drip irrigation devices composed of only hard labyrinth structures, the flow rate is changed largely with the length and the internal geometry of the labyrinth structure. Although a drip irrigation devices with only hard labyrinth structures can be fabricated simply, the changes of flow rates with internal fluid pressures are much larger than those of the drip irrigation devices with soft silicon. Because the drip irrigation devices with only labyrinth structures can be utilized widely through the optimization of the fluid pressure, the length of the structures, and the cross-sectional area of them, the study on the optimization can play an important role for enhancing the performance of the drip irrigation devices. In this study, experimental and numerical studies for investigating the performance of the drip irrigation devices had been conducted. In the experiments and numerical calculations(CFD), the variable parameters were the lengths of the labyrinth structures(#1~#8) and the fluid pressures(0.5~3.0 bar).

Properties of Temperature History of Lightweight Mortar for Fire Protection Covering Material in High Strength Concrete (고강도 콘크리트 내화피복용 경량 모르터의 온도이력 성상)

  • Lim, Seo-Hyung
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.45-50
    • /
    • 2012
  • The spalling causes the sever reduction of the cross sectional area with the exposure of the reinforcing steel, which originates a problem in the structural behaviour. By coating surface of high strength concrete with fireproof mortar, the high strength concrete is protected from the spalling in fire and the method to constrain the temperature increase of steel bar within the concrete. The purpose of this study is to investigate the temperature history properties of lightweight mortar using perlite and polypropylene fiber for fire protection covering material. For this purpose, selected test variables were the contents and length of polypropylene fiber. As a result of this study, it has been found that addition of polypropylene fiber to mortar modifies its pore structure and this causes the internal temperature to rise. And it has been found that a new lightweight mortar can be used in the fire protection covering material.

THE STUDY ON THE STRUCTURE OF DAEGYUPYO IN THE EARLY JOSEON DYNASTY (조선전기 대규표의 구조에 대한 연구)

  • Mihn, Byeong-Hee;Lee, Ki-Won;Kim, Sang-Hyuk;Ahn, Young-Sook;Lee, Yong-Sam
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.2
    • /
    • pp.29-37
    • /
    • 2012
  • In this paper, we study the structure of the Daegyupyo (大圭表, Large Gnomon) of the early Joseon dynasty. A Gyupyo (圭表, Gnomon that is Guibiao as pronounced in Chinese) is composed of a Pyo (表, Biao as pronounced in Chinese) making a shadow and a Gyu (圭, Gui as pronounced in Chinese) measuring its length. It is known that the Daegyupyo with the 40-feet height was constructed between the sixteenth to seventeenth year of the King Sejong reign (1444 - 1445) on the basis of the record of Yuanshi (元史, the History of the Yuan Dynasty). By analyzing historical documents such as Joseonwangjosillok (朝鮮王朝實錄, the Annals of the Joseon Dynasty), Yuanshi, and Jegaryeoksangjip (諸家曆象集, a work written by Sunji Lee), we found a possibility that the Ji (池, a pond) on the Gyu was located in the north side of the Pyo. This structure is different from that in previous studies, but is in a good agreement with that of the 40-feet Guibiao remaining in Dengfeng (登封) of China. Regarding to the Hoengyang (橫梁, cross-bar), we suggest that it was set up by double 5-feet supporting arms apart from the north tip of the Pyo in the radial direction. The 3:4:5 ratio in a rectangular triangle was used to place the Heongyang on the top of the Pyo at a distance of 4-feet (3-feet) in the vertical (horizontal) direction. We also discuss the structural problem when the Hoengyang is positioned apart from the top of the Pyo by supporting arms. In conclusion, we think that this study should be useful in restoring the Daegyupyo of the Joseon dynasty.

Cyclic Loading Tests for Prefabricated Composite Columns Using Steel Angle and Reinforcing Bar (PSRC 합성기둥의 반복가력 실험)

  • Hwang, Hyeon Jong;Eom, Tae Sung;Park, Hong Gun;Lee, Chang Nam;Kim, Hyoung Seop
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.6
    • /
    • pp.635-647
    • /
    • 2013
  • PSRC composite column is a concrete encased steel angle column. In the PSRC composite column, the steel angles placed at the corner of the cross-section resists bending moment and compression load. In the present study, using the performance criteria in KBC 2009, cyclic lateral loading test was performed for PSRC columns to verify the seismic performance. The test parameters were the column type, the use of continuous hoop, and the use of studs for steel angle. 2/3 scale specimens of a conventional composite column and three PSRC columns were tested. The test results showed that the load-carrying capacity predicted by KBC 2009 correlated well with the test results. The specimens also exhibited good deformation and energy dissipation capacities. After concrete cover spalling under cyclic loading, the load-carrying capacity were decreased by buckling of longitudinal bars and steel angles. When continuous hoop was used, the deformability of the PSRC column was improved, preventing early buckling of the steel angles.

A Hydraulic Experiment Using Artificial Seaweed for Coastal Erosion Prevention (인공식생을 이용한 해빈침식방지에 관한 수리실험)

  • Kim, Beom Mo;Jeon, Yong Ho;Yoon, Han Sam
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.4
    • /
    • pp.266-273
    • /
    • 2016
  • Two-dimensional hydraulic experiments were performed to assess the impact of artificial seaweed on wave energy attenuation, and coastal erosion prevention. In this experimental study, erosion geometry and wave reflection coefficients were determined for normal and stormy incident waves, with and without artificial seaweed. The coastline of beaches without artificial vegetation was observed to retreat, and the longshore bar height increased in normal and stormy conditions. Through the introduction of artificial seaweed (of widths 0.8 m, and 1.6 m), the coastline was found to advance in the offshore direction due to material deposition. From these results, it is shown that artificial seaweed alters the cross-section of beaches, such that it is possible to prevent coastline erosion.

Implications of yield penetration on confinement requirements of r.c. wall elements

  • Tastani, Souzana P.;Pantazopoulou, Stavroula J.
    • Earthquakes and Structures
    • /
    • v.9 no.4
    • /
    • pp.831-849
    • /
    • 2015
  • Seismic-design procedures for walls require that the confinement in the critical (plastic hinge) regions should extend over a length in the compression zone of the cross section at the wall base where concrete strains in the Ultimate Limit State (ULS) exceed the limit of 0.0035. In a performance-based framework, confinement is linked to required curvature ductility so that the drift demand at the performance point of the structure for the design earthquake may be met. However, performance of flexural walls in the recent earthquakes in Chile (2010) and Christchurch (2011) indicates that the actual compression strains in the critical regions of many structural walls were higher than estimated, being responsible for several of the reported failures by toe crushing. In this study, the method of estimating the confined region and magnitude of compression strain demands in slender walls are revisited. The objective is to account for a newly identified kinematic interaction between the normal strains that arise in the compression zone, and the lumped rotations that occur at the other end of the wall base due to penetration of bar tension yielding into the supporting anchorage. Design charts estimating the amount of yield penetration in terms of the resulting lumped rotation at the wall base are used to quantify the increased demands for compression strain in the critical section. The estimated strain increase may exceed by more than 30% the base value estimated from the existing design expressions, which explains the frequently reported occurrence of toe crushing even in well confined slender walls under high drift demands. Example cases are included in the presentation to illustrate the behavioral parametric trends and implications in seismic design of walls.

Stud reinforcement in beam-column joints under seismic loads

  • Abdollahzadeh, Gholamreza;Ghalani, Saeed Eilbeigi
    • Computers and Concrete
    • /
    • v.18 no.3
    • /
    • pp.297-317
    • /
    • 2016
  • Current codes recommend large amounts of shear reinforcement for reinforced concrete beam-column joints that causes significant bar congestion. Increase in congestion of shear reinforcement in joint core (connection zone), leads to increase accomplishment problems. The congestion may also lead to diameter limitations on the beam bars relative to the joint dimensions. Using double headed studs instead of conventional closed hoops in reinforced concrete beam-column joints reduces congestion and ensures easier assembly of the reinforcing cage. The purpose of this research is evaluating the efficiency of the proposed reinforcement. In this way, 10 groups of exterior beam-column joints are modeled. Each group includes 7 specimens by different reinforcing details in their joint core. All specimens are modeled by using of ABAQUS and analyzed subjected to cyclic loading. After verification of analytical modeling with an experimental specimen, 3D nonlinear specimens are modeled and analyzed. Then, the effect of amount and arrangement of headed studs on ductility, performance, ultimate strength and energy absorption has been studied. Based on the results, all joints reinforced with double headed studs represent better performance compared with the joints without shear transverse reinforcement in joints core. The behavior of the former is close to joints reinforced with closed hoops and cross ties according to the seismic design codes. By adjusting the arrangement of double-headed studs, the decrease in ductility, performance, ultimate moment resistant and energy absorption reduce to 2.61%, 0.90%, 0.90% and 1.66% respectively compared with the joints reinforced by closed hoops on the average. Since the use of headed studs reduces accomplishment problems, these amounts are negligible. Therefore, use of double-headed studs has proved to be a viable option for reinforcing exterior beam-column joints.

Perceptions of Turkish University Students about the Effects of Water Pipe Smoking on Health

  • Sahin, Sevil;Cinar, Nursan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.11
    • /
    • pp.4615-4621
    • /
    • 2015
  • Background: The popularity of the water pipe, also referred to as hookah, narghile, shisha or hubble-bubble, has increased tremendously during the past few decades. This study was conducted to determine student water pipe smoking status and perceptions about the effects of water pipe smoking on health in a state university in Ankara. Materials and Methods: This cross-sectional study was conducted between September 2014 and January 2015. The data were collected with a questionnaire and "The Scale of Perception about the Effects of Water Pipe Smoking on Health". The data obtained were evaluated in IBM SPSS (version 20.0) statistical package program in computer. One-way analysis of variance (ANOVA) was used for the analyses by checking homogeneity of variances and Student's t-test. Values of p<0.05 were considered statistically significant. Results: The total mean score obtained by young people who took part in the study was determined as ($\bar{X}=65.20{\pm}1.25$, min=33, max=75). Upon comparison of the total mean scores obtained by young people from the Scale of Perception about the effects of water pipe smoking on health and gender variable, the scores obtained by the females students were higher than those of the male students with a statistically significant difference (t=7.525, p<0.05). A statistically significant difference was observed between the total mean scores obtained by young people with cigarette and water pipe smoking status (for each, t=-3.731, p<0.05; t=-13.987, p<0.05). Conclusions: In conclusion, university students have wrong knowledge on the dangers of water pipe smoking. There was a high prevalence of using water pipes among university students. Gender significantly affected the perceptions about the effect of water pipe smoking on health in our sample.

Numerical Analysis on a Hydrogen Diaphragm Compressor with Various Oil Distribution Holes Pattern for Hydrogen Compressor (수소용 다이어프램 압축기의 오일 분배 홀 패턴에 따른 수치해석)

  • Park, Hyun-Woo;Shin, Young-Il;Kim, Gyu-Bo;Song, Ju-Hun;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • There are several types of compressors which are appropriate for hydrogen gas station. Diaphragm type of compressor is the one of them and it satisfies the requirements for that purpose in terms of maintaining gas purity and making high pressure over 700 bar. The objective of this study is to find an optimal design of oil distribution hole configuration. The number of holes is changed maintaining total cross-sectional area of holes. Five cases(1 hole, 4, 8,16 and 24 holes) were studied through Fluid Structure Interaction(FSI) analysis method. Gas and oil pressure, the deflection and stress of the diaphragm were analysed during compression and suction process respectively. There is no specific difference among the cases during compression. An additional deflection due to the existence of hole was found during suction for all case. But the highest deflection and stress were found in the 1 hole case. It was seen that 60% decrease of stress in magnitude in 24 hole case compare to the 1 hole case.