• Title/Summary/Keyword: Critical circulating frequency

Search Result 7, Processing Time 0.024 seconds

Critical Suspension Condition of Particles in a Shaking Vessel of Solid-Liquid System (고-액계 진동교반에서 입자의 부유화 한계조건)

  • Lee, Young-Sei;Kim, Moon-Gab;Kato, Yoshihito
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.2
    • /
    • pp.73-81
    • /
    • 1999
  • Shake mixing has been widely used in cell culture. The mixing performance for shake mixing, however, has not been reported quantitatively. The critical circulating frequency and the power consumption for complete suspension of particles, based on the definition of Zwietering, were measured in a shaking vessel containing a solid-liquid system. The critical suspension frequency was correlated by the equation from Baldi's particle suspension model modified with the physical properties of the particles. Critical suspension frequency was correlated as following ; $$N_{JS}={\frac{0.58\;d{_p}^{0.06}(g{\Delta}{\rho}/{\rho}_L)^{0.004}X^{0.03}}{D^{0.35}d^{0.17}{\upsilon}^{0.04}}}$$ The power consumption at the critical suspension condition in the shaking vessel was less than that in an agitated vessel with impeller.

  • PDF

Flow Patterns and Critical Circulation Frequency for Mixing in Shaking Vessels with Various Geometry (진동교반조의 기하형상에 따른 유동상태와 혼합한계회전수)

  • Lee, Young-Sei;Kim, Moon-Gab;Kim, Jong-Shik;Ue, Takafumi;Kato, Yoshihito
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.1
    • /
    • pp.49-56
    • /
    • 2003
  • Based on the flow patterns of cylindrical vessel, the flow patterns of conical vessel, spherical vessel, rectangular vessel and cylindrical vessel with baffles were visualized by a trace method using aluminum powder. In addition, the correlations of the critical circulating frequency for mixing were derived from the experimental results. The conical and spherical vessels which have circular cross sections were same effective as cylindrical vessel for the shake mixing due to developing the rotational flow. Both a rectangular vessel and a cylindrical vessel with baffles should not be adapted for shake mixing because of not developing rotational flows in these type of vessels.

  • PDF

Clinical Features according to the Frequency of Acute Exacerbation in COPD

  • Lee, Seung-Jun;Lee, Seung-Hun;Kim, Yu-Eun;Cho, Yu-Ji;Jeong, Yi-Yeong;Kim, Ho-Cheol;Kim, Jin-Hyun;You, Jin-Jong;Yoon, Chul-Ho;Lee, Jong-Deog;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.4
    • /
    • pp.367-373
    • /
    • 2012
  • Background: Chronic obstructive pulmonary disease (COPD) is now regarded as a heterogenous disease, with variable phenotypes. Acute exacerbation of COPD is a major event that alters the natural course of disease. The frequency of COPD exacerbation is variable among patients. We analyzed clinical features, according to the frequency of acute exacerbation in COPD. Methods: Sixty patients, who visited Gyeongsang National University Hospital from March 2010 to October 2010, were enrolled. Patients were divided into two groups, according to their frequency of acute exacerbation. Frequent exacerbator is defined as the patient who has two or more exacerbation per one year. We reviewed patients' medical records and investigated modified Medical Research Council (MMRC) dyspnea scale, smoking history and frequency of acute exacerbation. We also conducted pulmonary function test and 6-minute walking test, calculated body mass index, degree of airway obstruction and dyspnea and exercise capacity (BODE) index and measured CD146 cells in the peripheral blood. Results: The number of frequent exacerbators and infrequent exacerbators was 20 and 40, respectively. The frequent exacerbator group had more severe airway obstruction (forced expiratory volume in one second [$FEV_1$], 45% vs. 65.3%, p=0.001; $FEV_1$/forced vital capacity, 44.3% vs. 50.5%, p=0.046). MMRC dyspnea scale and BODE index were significantly higher in the frequent exacerbator group (1.8 vs. 1.1, p=0.016; 3.9 vs. 2.1, p=0.014, respectively). The fraction of CD146 cells significantly increased in the frequent exacerbator group (2.0 vs. 1.0, p<0.001). Conclusion: Frequent exacerbator had more severe airway obstruction and higher symptom score and BODE index. However, circulating endothelial cells measured by CD146 needed to be confirmed in the future.

A New DC-DC Converter Topology For High-Efficiency Electric Vehicle Rapid Chargers (전기전동차 급속충전기 고효율화를 위한 새로운 DC-DC 컨버터 토폴로지)

  • Kim, Jin-Hak;Lee, Woo-Seok;Choi, Seung-Won;Lee, Jun-Young;Lee, Il-Oun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.182-189
    • /
    • 2018
  • LLC resonant converters or phase-shift full-bridge converters have been widely used as DC - DC converters for rapid charging of electric vehicles (EVs). However, these converters present critical disadvantages, including a large circulating current, which can hinder efficiency and miniaturization in EV battery charger applications. In this paper, a new DC - DC converter topology is proposed for EV rapid chargers. The proposed converter can operate at high frequency despite a high rated power capacity of over 20kW, and the problem of circulating current can be minimized during the entire battery charging time. Owing to these advantages, the proposed converter can achieve a high conversion efficiency of over 97% for EV rapid charger applications. The performance of the proposed converter is verified with 20kW prototypes in this study.

An experimental study of a circular cylinder's two-degree-of-freedom motion induced by vortex

  • Kim, Shin-Woong;Lee, Seung-Jae;Park, Cheol-Young;Kang, Donghoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.330-343
    • /
    • 2016
  • This paper presents results of an experimental investigation of vortex-induced vibration (VIV) of a flexibly mounted and rigid cylinder with two-degrees-of-freedom with respect to varying ratio of in-line natural frequency to cross-flow natural frequency, $f^*$, at a fixed low mass ratio. Combined in-line and cross-flow motion was observed in a sub-critical Reynolds number range. Three-dimensional displacement meter and tension meter were used to measure dynamic responses of the model. To validate the results and the experiment system, x and y response amplitudes and ratio of oscillation frequency to cross-flow natural frequency were compared with other experimental results. It has been found that the higher harmonics, such as third and more vibration components, can occur on a certain part of steel catenary riser under a condition of dual resonance mode. In the present work, however, due to the limitation of a size of circulating water channel, the whole test of a whole configuration of the riser at an adequate scale for VIV phenomenon was not able to be conducted. Instead, we have modeled a rigid cylinder and assumed that the cylinder is a part of steel catenary riser where the higher harmonic motions could occur. Through the experiment, we have found that even though the cylinder was assumed to be rigid, the occurrence of the higher harmonic motions was observed in a small reduced velocity ($V_r$) range, where the influence of the in-line response is relatively large. The transition of the vortex shedding mode from one to another was examined by using time history of x and y directional displacement over all experimental cases. We also observed the influence of in-line restoring force power spectral density with $f^*$.

Analysis of Multi-Agent-Based Adaptive Droop-Controlled AC Microgrids with PSCAD: Modeling and Simulation

  • Li, Zhongwen;Zang, Chuanzhi;Zeng, Peng;Yu, Haibin;Li, Hepeng;Li, Shuhui
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.455-468
    • /
    • 2015
  • A microgrid (MG) with integrated renewable energy resources can benefit both utility companies and customers. As a result, they are attracting a great deal of attention. The control of a MG is very important for the stable operation of a MG. The droop-control method is popular since it avoids circulating currents among the converters without using any critical communication between them. Traditional droop control methods have the drawback of an inherent trade-off between power sharing and voltage and frequency regulation. An adaptive droop control method is proposed, which can operate in both the island mode and the grid-connected mode. It can also ensure smooth switching between these two modes. Furthermore, the voltage and frequency of a MG can be restored by using the proposed droop controller. Meanwhile, the active power can be dispatched appropriately in both operating modes based on the capacity or running cost of the Distributed Generators (DGs). The global information (such as the average voltage and output active power of the MG and so on) required by the proposed droop control method to restore the voltage and frequency deviations can be acquired distributedly based on the Multi Agent System (MAS). Simulation studies in PSCAD demonstrate the effectiveness of the proposed control method.

Theoretical Heat Flow Analysis and Vibration Characteristics During Transportation of PCS(Power Conversion System) for Reliability (전력변환장치 캐비넷에서의 내부발열 개선을 위한 열유동 분석 및 유통안전성 향상을 위한 진동특성 분석)

  • Joo, Minjung;Suh, Sang Uk;Oh, Jae Young;Jung, Hyun-Mo;Park, Jong-Min
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.2
    • /
    • pp.143-149
    • /
    • 2022
  • PCS needs to freely switch AC and DC to connect the battery, external AC loads and renewable energy in both directions for energy efficiency. Whenever converting happens, power loss inevitably occurs. Minimization of the power loss to save electricity and convert it for usage is a very critical function in PCS. PCS plays an important role in the ESS(Energy Storage System) but the importance of stabilizing semiconductors on PCB(Printed Circuit Board) should be empathized with a risk of failure such as a fire explosion. In this study, the temperature variation inside PCS was reviewed by cooling fan on top of PCS, and the vibration characteristics of PCS were analyzed during truck transportation for reliability of the product. In most cases, a cooling fan is mounted to control the inner temperature at the upper part of the PCS and components generating the heat placed on the internal aluminum cooling plate to apply the primary cooling and the secondary cooling system with inlet fans for the external air. Results of CFD showed slightly lack of circulating capacity but simulated temperatures were durable for components. The resonance points of PCS were various due to the complexity of components. Although they were less than 40 Hz which mostly occurs breakage, it was analyzed that the vibration displacement in the resonance frequency band was very insufficient. As a result of random-vibration simulation, the lower part was analyzed as the stress-concentrated point but no breakage was shown. The steel sheet could be stable for now, but for long-term domestic transportation, structural coupling may occur due to accumulation of fatigue strength. After the test completed, output voltage of the product had lost so that extra packaging such as bubble wrap should be considered.