• Title/Summary/Keyword: Critical Factor of Using

Search Result 1,131, Processing Time 0.026 seconds

Factors Affecting Industry and University Collaboration in Education in the Hospitality Industry in Vietnam: A Business Perspective

  • NGUYEN, Thang Quyet;NGUYEN, Hoa Thi Thu
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.2
    • /
    • pp.291-300
    • /
    • 2020
  • This paper studies the factors affecting university and industry collaboration in education in the hospitality industry in Ho Chi Minh City (Vietnam) from a company perspective. The authors use qualitative method and quantitative research to study the matters, specifically using scales and data collected for Cronbach alpha reliability testing, analysizing the discovery factor of EFA, CFA and verifying the regression models through AMOS software with SEM linear modeling. The study proposes four factors: (1) organization factors, (2) contextual factors, (3) process factors, and (4) cooperation perspective impacting on the benefits factors and university and industry collaboration in education. In addition, it is also found that benefits factors has a direct and positive impact on the collaboration in education. The results suggest that the process factor had the strongest positive, followed by the contextual factor. The findings revealed that the benefit factors were significantly related to collaboration in education, which affects university and industry hospitality alliances. This finding confirm that the cooperation perspective (QD) and contextual factors (HC) are critical in collaboration between university and industry. A new point of interest is also identified that the benefits of training links are quite dependent on the linking perspective from tourism businesses.

A Study On Uninterruptible Power Supply System Using PWM Converter (PWM 컨버터를 이용한 무정전전원시스템에 관한 연구)

  • So, Jung-Hwan;Kim, Hong-Sung;Choe, Gyu-Ha;Kim, Han-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.206-208
    • /
    • 1995
  • Recently according to the increasing critical loads such as communication and life support systems stable power supplying becomes more and more important. Therefore it is indespensable to stabilize power source using these instruments - AVR(Automatic Voltage Regulator) or UPS(Uninterrutible Power Supply). This paper deals with ON-LNE UPS which is composed of PWM converter for AC-DC conversion. Using a PWM converter have advantages of low current harmonics and high power factor. In this paper ON-LNE UPS using PWM converter is proposed and its characteristics are investigated.

  • PDF

Fatigue Crack Growth Rate Equation by Crack Closure (균열닫힘현상을 고려한 피로균열전파식)

  • 김용수;강동명;신근하
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.4
    • /
    • pp.81-87
    • /
    • 1991
  • We propose the crack growth rate equation which will model fatigue crack growth rate behavior such that constant stress amplitude fatigue crack growth behavior can be predicted. Constant stress amplitude fatigue tests are conducted for four materials under three stress ratios of R=0.2, R=0.4 and R=0.6. Materials which have different mechanical properties i.e. stainless steel, low carbon steel, medium carbon steel and aluminum alloy are used. Through constant stress amplitude fatigue test by using unloading elastic compliance method, it is confirmed that crack closure is a close relationship with fatigue crack propagation. We describe simply fatigue crack propagation behavior as a function of the effective stress intensity factor range ($\Delta$ $K_{eff}$=U .$\Delta$K) for all three regions (threshold region, stable region). The fatigue crack growth rate equation is given by da / dN=A($\Delta$ $K_{eff}$­$\Delta$ $K_{o}$ )$^{m}$ / ($\Delta$ $K_{eff}$­$\Delta$K) Where, A and m are material constants, and $\Delta$ $K_{o}$ is stress intensity factor range at low $\Delta$K region. $K_{cf}$ is critical fatigue stress intensity factor.actor.

  • PDF

A study on the effect of ground conditions of room and pillar method on pillar and room strain (격자형 지하공간의 지반조건이 암주와 룸 변형률에 미치는 영향에 대한 연구)

  • Ham, Hyeon Su;Kim, Yong Kyu;Park, Chi Myeon;Lee, Chul Ho;Kim, YoungSeok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.577-587
    • /
    • 2021
  • Room and Pillar method is an underground facility construction method that maximizes the strength of the in-situ ground. In order to secure the safety of the underground space, it is necessary to secure the safety of the room actually used in addition to the safety of pillar of the room and Pillar method. In this study, the evaluation method for the safety of the room and rock pillar in the room and pillar method was studied through numerical analysis. Numerical analysis was performed for a total of 125 cases using ground conditions, pillar width, and room width as parameters, and the results were derived. As for the safety factor of the pillar, it was confirmed that the safety factor increased when the strength of the ground increased, and it was confirmed that the increment in the safety factor decreased when the width of the pillar was widened. The room strain was evaluated by applying the Critical strain. As the width of the pillar became narrower, the Critical strain was higher, and as the width of the room became smaller, the Critical strain was smaller. As a result of the correlation analysis between the safety factor of the pillar and the room strain, it was possible to derive the upper limit of the room strain that can secure the standard safety factor of the pillar according to the width of the pillar. It is judged that the results derived from this study can be used as a guideline to secure the safety of the room when the actual design is performed in consideration of the ground conditions and room width.

A Study of the Structure and Luminescence Properly of BaMgAl10O17:Eu2+ Blue Phosphor using Scattering Method (Scattering법을 이용한 BaMgAl10O17:Eu2+ 청색형광체의 구조와 발광특성 연구)

  • 김광복;김용일;구경완;천희곤;조동율
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.1
    • /
    • pp.67-74
    • /
    • 2002
  • A phosphor for Plasma Display Panel, BaMgAl$_{10}$ O$_{17}$ :Eu$^{2+}$, showing a blue emission band at about 450nm was prepared by a solid-state reaction using BaCO$_3$, $Al_2$O$_3$, MgO, Eu$_2$O$_3$ as starting materials wish flux AlF$_3$. The study of the behaviour of Eu in BAM phosphor was carried out by the photoluminescence spectra and the Rietveld method with X-ray and neutron powder diffraction data to refine the structural parameters such as lattice constants, the valence state of Eu, the preferential site of Mg atom and the site fraction of each atom. The phenomenon of the concentration quenching was abound 2.25~2.3wt% of Eu due to a decrease in the critical distance for energy transfer of inter-atomic Eu. Through the combined Rietveld refinement, R-factor, R$_{wp}$, was 8.11%, and the occupancy of Eu and Mg was 0.0882 and 0.526 at critical concentration. The critical distance of Eu$^{2+}$ in BAM was 18.8$\AA$ at 2.25% Eu of the concentration quenching. Furthermore, c/a ratio was decreased to 3.0wt% and no more change was observed over that concentration. The maximum entropy electron density was found that the modeling of $\beta$-alumina structure in BaMgAl$_{10}$ O$_{17}$ :Eu$^{2+}$correct coincided showing Ba, Eu, O atoms of z= 1/4 mirror plane.e.ane.e.

Nonhydrostatic Effects on Convectively Forced Mesoscale Flows (대류가 유도하는 중규모 흐름에 미치는 비정역학 효과)

  • Woo, Sora;Baik, Jong-Jin;Lee, Hyunho;Han, Ji-Young;Seo, Jaemyeong Mango
    • Atmosphere
    • /
    • v.23 no.3
    • /
    • pp.293-305
    • /
    • 2013
  • Nonhydrostatic effects on convectively forced mesoscale flows in two dimensions are numerically investigated using a nondimensional model. An elevated heating that represents convective heating due to deep cumulus convection is specified in a uniform basic flow with constant stability, and numerical experiments are performed with different values of the nonlinearity factor and nonhydrostaticity factor. The simulation result in a linear system is first compared to the analytic solution. The simulated vertical velocity field is very similar to the analytic one, confirming the high accuracy of nondimensional model's solutions. When the nonhydrostaticity factor is small, alternating regions of upward and downward motion above the heating top appear. On the other hand, when the nonhydrostaticity factor is relatively large, alternating updraft and downdraft cells appear downwind of the main updraft region. These features according to the nonhydrostaticity factor appear in both linear and nonlinear flow systems. The location of the maximum vertical velocity in the main updraft region differs depending on the degrees of nonlinearity and nonhydrostaticity. Using the Taylor-Goldstein equation in a linear, steady-state, invscid system, it is analyzed that evanescent waves exist for a given nonhydrostaticity factor. The critical wavelength of an evanescent wave is given by ${\lambda}_c=2{\pi}{\beta}$, where ${\beta}$ is the nonhydrostaticity factor. Waves whose wavelengths are smaller than the critical wavelength become evanescent. The alternating updraft and downdraft cells are formed by the superposition of evanescent waves and horizontally propagating parts of propagating waves. Simulation results show that the horizontal length of the updraft and downdraft cells is the half of the critical wavelength (${\pi}{\beta}$) in a linear flow system and larger than ${\pi}{\beta}$ in a weakly nonlinear flow system.

Yaw Gearbox Design for 4MW Class Wind Turbine (4MW급 풍력발전기용 요 감속기 설계)

  • Lee, Hyoung-Woo;Kim, In-Hwan;Lee, Jae-Shin
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.2
    • /
    • pp.142-148
    • /
    • 2022
  • In this paper, the weight reduction design of the yaw gearbox for wind turbine was performed through the finite element analysis method, and the stability was checked by performing the critical speed analysis. The weight reduction product can improve engine efficiency, save parts materials, and earn economic benefits. The yaw gearbox is lightweighted with the goal of achieving a safety rate of 1.3 or higher for wind turbine as indicated by IEC61400-1. In order to reduce the weight of the carrier, a topology optimization method was performed. The safety factor was verified by performing finite element analysis on the carrier. In addition, the housing and carrier were modeled using the finite element method, and the gear train was modeled using MASTA. For the yaw gearbox, the housing and carrier FE model and the gear train model were connected by the partial structural synthesis method to perform the rotational vibration analysis. Vibration excitation sources are mass unbalance and gear mesh frrequemcy, and as a result of the critical speed analysis, it was found that there was no resonance within the operating speed range.

The Reliability and Validity of the Evaluation Tool for the Performance Outcomes in Simulation Practicum -Focused on 'Applying Nursing Process through Critical Thinking' in Women's Health Nursing Simulation Practicum - (시뮬레이션 실습에서 학습성과 평가도구의 신뢰도 및 타당도 -여성건강 간호학 실습에서 비판적 추론과정을 통한 간호과정 적용(학습성과)을 중심으로-)

  • Lee, Yun Jung;Yeo, Ji Young;Lee, Sun-Kyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.154-162
    • /
    • 2017
  • The aim of study was to identify the reliability and validity of an evaluation tool developed on the basis of performance outcome in Women's Health Nursing simulation practicum. A total of 110 undergraduate nursing students were recruited from one college. Data collection of this study was conducted between August and December of 2014. The data were analyzed using factor analysis, multitrait/multi-item matrix analysis, Pearson's correlation coefficient, and Cronbach's alpha with SPSS win 20.0 program. An exploratory factor analysis demonstrated that the four-factor structures of 10 items explained 68.2% of the total variance. It was significantly correlated with the Critical Thinking Disposition scale(r=.42, p <.001). The Cronbach's alpha was 0.89,ranging from 0.61 to 0.92. The results of this study support the reliability and validity of this evaluation tool. It could be a useful tool in evaluating the performance outcome in simulation practicum for nursing students.

A Design Secure QR-Login User Authentication Protocol and Assurance Methods for the Safety of Critical Data Using Smart Device (스마트 기기를 이용한 안전한 QR-Login 사용자 인증 프로토콜의 설계 및 중요 정보의 안전성 보증을 위한 방법)

  • Lee, Jae-Sik;You, Han-Na;Cho, Chang-Hyun;Jun, Moon-Seog
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.10
    • /
    • pp.949-964
    • /
    • 2012
  • Our PC have been under constant threat of malicious codes and viruses today. As many new ways of cyber attacks are being developed, such as zero-day-attack, nobody's PC is guaranteed to be safe from the attacks. In case where a user uses the existing verification protocol on a unsecured PC, the user's verification information may well be threatened by sniffing or man-in-the-middle attack. Especially, deadly attacks like memory hacking would give hard time for users to even recognize any symptom of virus infection. Therefore, this paper designs secured QR-Login user verification protocol for smart devices that are ready to communicate with QR-Code and proposes a way to keep critical data safe when using the internet. This way, user would be able to safeguard his/her critical data even when under attack by unknown attacks and safely carry out extremely sensitive task, like financial trading, on the device.

Increased expression of vascular endothelial growth factor-C and vascular endothelial growth factor receptor-3 after pilocarpine-induced status epilepticus in mice

  • Cho, Kyung-Ok;Kim, Joo Youn;Jeong, Kyoung Hoon;Lee, Mun-Yong;Kim, Seong Yun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.23 no.4
    • /
    • pp.281-289
    • /
    • 2019
  • Vascular endothelial growth factor (VEGF)-C and its receptor, vascular endothelial growth factor receptor (VEGFR)-3, are responsible for lymphangiogenesis in both embryos and adults. In epilepsy, the expression of VEGF-C and VEGFR-3 was significantly upregulated in the human brains affected with temporal lobe epilepsy. Moreover, pharmacologic inhibition of VEGF receptors after acute seizures could suppress the generation of spontaneous recurrent seizures, suggesting a critical role of VEGF-related signaling in epilepsy. Therefore, in the present study, the spatiotemporal expression of VEGF-C and VEGFR-3 against pilocarpine-induced status epilepticus (SE) was investigated in C57BL/6N mice using immunohistochemistry. At 1 day after SE, hippocampal astrocytes and microglia were activated. Pyramidal neuronal death was observed at 4 days after SE. In the subpyramidal zone, VEGF-C expression gradually increased and peaked at 7 days after SE, while VEGFR-3 was significantly upregulated at 4 days after SE and began to decrease at 7 days after SE. Most VEGF-C/VEGFR-3-expressing cells were pyramidal neurons, but VEGF-C was also observed in some astrocytes in sham-manipulated animals. However, at 4 days and 7 days after SE, both VEGFR-3 and VEGF-C immunoreactivities were observed mainly in astrocytes and in some microglia of the stratum radiatum and lacunosum-moleculare of the hippocampus, respectively. These data indicate that VEGF-C and VEGFR-3 can be upregulated in hippocampal astrocytes and microglia after pilocarpine-induced SE, providing basic information about VEGF-C and VEGFR-3 expression patterns following acute seizures.