• Title/Summary/Keyword: Critical Facility

Search Result 317, Processing Time 0.035 seconds

Preliminary Post-closure Safety Assessment of Disposal Options for Disused Sealed Radioactive Source (폐밀봉선원 처분방식별 폐쇄후 예비안전성평가)

  • Lee, Seunghee;Kim, Juyoul;Kim, Sukhoon
    • Economic and Environmental Geology
    • /
    • v.49 no.4
    • /
    • pp.301-314
    • /
    • 2016
  • Disused Sealed Radioactive Sources (DSRSs) are stored temporally in the centralized storage facility of Korea Radioactive Waste Agency (KORAD) and planned to be disposed in the low- and intermediate-level radioactive waste (LILW) disposal facility in Gyeongju city. In this study, preliminary post-closure safety assessment was performed for DSRSs in order to draw up an optimum disposal plan. Two types of disposal options were considered, i.e. engineered vault type disposal and rock cavern type disposal which were planned to be constructed and operated respectively in LILW disposal facility in Gyeongju city. Assessment end-point was individual effective dose of critical group and calculated by using GoldSim code. In normal scenario, the maximum dose was estimated to be approximately $1{\times}10^{-7}mSv/yr$ for both disposal options. It meant that both options had sufficient safety margin when compared with regulatory limit (0.1 mSv/yr). Otherwise, in well scenario, the maximum dose exceeded regulatory limit of 1 mSv/yr in engineered vault type disposal and the exposure dose was mainly contributed by $^{226}Ra$, $^{210}Pb$ (daughter nuclide of $^{226}Ra$) and $^{237}Np$ (daughter nuclide of $^{241}Am$). For rock cavern type disposal, even though the peak dose satisfied regulatory limit, the exposure doses by $^{14}C$ and $^{237}Np$ were relatively high above 10% of regulatory limit. Therefore, it is necessary to exclude $^{14}C$, $^{226}Ra$ and $^{241}Am$ for two type of disposal options and additional management such as long-term storage and development of disposal container for those radionuclides should be performed before permanent disposal for conservative safety and security.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

A Study on Operation Strategy by Multi-variate Regression of Deagu Arboretum Visitor's Satisfaction (대구수목원 이용객 만족모델을 통한 운영 방안 연구)

  • Kang, Kee-Rae
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.1
    • /
    • pp.36-45
    • /
    • 2012
  • Education on the environment and plants offered by arboretum for today's people not only contribute to foster a better natural environment in urban region but also provide visitors with decent refreshment environment and beyond. In the study, the author undertook the observation on usage behavior and satisfaction model of arboretum visitors expect and investigated the facilities and programs to be offered by arboretum in order to propose the opinion regarding the service. For observation size of variables in a multiple regression analysis of variables is influencing satisfaction rankings walks the line of flow, the educational effect on the environment, cleanliness of the facility, visits pay, natural beauty, diversity of trees, accessibility and friendliness of staff, expansion of facilities in the arboretum and appeared as a complement. In case of visitor attribute, the residents living near the facility showed the highest visit frequency of more than 5 times, especially as part of taking a walk. This proves that the visit to arboretum is considered as part of everyday life, and thus a new program and walk path as well as movement route are needed to be developed for the visitors. In the question relating to the facilities and operation programs in Daegu Arboretum, particularly the requests by visitors, they responded that the establishment of cultural event, beautiful natural scenery, refreshment and convenience facilities is the most critical issue. In addition, the management on withered trees and bare lands is an urgent issue as well. In this sense, the Operation and Management Strategies based upon the visitor behaviors and model of satisfaction are needed to deal with the adoption of diverse events and festivals joined by local residents, ombudsman program, environmental program development for students and teachers within the region, negligent bare lands and withered tree replacement, and cafeteria facility improvement and supplement as well as the bench marking of other facilities than arboretums located in other regions. These items are thought to be sufficiently dealt with by Daegu Arboretum having no more external resources. It is recognized that the visitor satisfaction begins from a minor thing, and a small difference determines a great satisfaction, and thus the software approach rather than hardware one is in need.

Microbiological Hazard Analysis for HACCP System Application to Vinegared Pickle Radishes (식초절임 무의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.1
    • /
    • pp.69-74
    • /
    • 2013
  • This study has been performed for 150 days from February 1 - June 31, 2012 aiming at analyzing biologically hazardous factors in order to develop HACCP system for the vinegared pickle radishes. A process chart was prepared as shown on Fig. 1 by referring to manufacturing process of manufacturer of general vinegared pickle radishes regarding process of raw agricultural products of vinegared pickle radishes, used water, warehousing of additives and packing material, storage, careful selection, washing, peeling off, cutting, sorting out, stuffing (filling), internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, E. coli O157:H7, Clostridium perfringens, Yeast and Mold before and after washing raw radishes, Bacillus cereus was $5.00{\times}10$ CFU/g before washing but it was not detected after washing and Yeast and Mold was $3.80{\times}10^2$ CFU/g before washing but it was reduced to 10 CFU/g after washing and other pathogenic bacteria was not detected. As a result of testing microorganism variation depending on pH (2-5) of seasoning fluid (condiment), pH 3-4 was determined as pH of seasoning fluid as all the bacteria was not detected in pH3-4. As a result of testing air-borne bacteria (number of general bacteria, colon bacillus, fungus) depending on each workplace, number of microorganism of internal packing room, seasoning fluid processing room, washing room and storage room was detected to be 10 CFU/Plate, 2 CFU/Plate, 60 CFU/Plate and 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of general bacteria and colon bacillus was represented to be high as 346 $CFU/Cm^2$ and 23 $CFU/Cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, colon bacillus was not detected in all the specimen but general bacteria was most dominantly detected in PP Packing machine and Siuping machine (PE Bulk) as $4.2{\times}10^3CFU/Cm^2$, $2.6{\times}10^3CFU/Cm^2$, respectively. As a result of analyzing above hazardous factors, processing process of seasoning fluid where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and threshold level (critical control point) was set at pH 3-4. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.

A Study in an Effective Programs for Emergency Care Delivery System (응급의료 전달체계의 충실 방안)

  • Kwon Sook Hee
    • Journal of Korean Public Health Nursing
    • /
    • v.9 no.1
    • /
    • pp.83-102
    • /
    • 1995
  • As the society is being industrialized, the fast-paced economic development that has caused substantial increase in cerebrovascular and coronary artery diseases and the industrial development and increased use of means of transportation have resulted in the rapid rise of incidents in external injuries as well. So the pubic has become acutely aware of the need for fast and effective emergency care delivery system. The goal of emergency care delivery system is to meet the emergency care needs of patients. The emergency care delivery system is seeking to efficiently satisfy the care needs of people. Therefore the purpose of this study is designed to develop an effective programs for emergency care delivery system in Korea. The following specific objectives were investigated. This emergency care delivery system must have the necessary man power, for transfering the patients, communication net work, and emergency care facilities. 1) Man power Emergency care requires n0t only specialized traning in the emergency treatment but also knowledge and experience i11 other related area, so emergency care personnel traning program should be designed in order to adapt to the specific need of emergency patients. It will be necessary to ensure professional personnel who aquires the sufficient traning and experience for emergency care and to look for legal basis. We have to develop re-educational programs for emergency nurse specialist. They should be received speciality of emergency nursing care so that they will work actively and positively in emergency part. Emergency medical doctor and nurse specialist should be given an education which is related in emergency and critical care. Emergency care personnel will continue to provide both acute and continuing care as partner with other medical team. 2) Transfering the patients. Successful management of pre-hospital care requires adequate traning for the emergency medical technician. Traning program should be required to participate in a actual first aids activites in order to have apportunities to acquire practical skills as well as theoretical knowledge. The system of emergency medical technician should be remarkablly successful with first responder firefighters. Establishing this system must add necessary ambulances operating at any given time. It will be necessary to standardize the ambulance size and equipment. Ambulance should be arranged with each and every fire station. 3) Communication net work. The head office of emergency commumication network should be arranged with the head office of fire station in community. It is proposed that Hot-line system for emergency care should be introduce. High controlled ambulance and thirtial emergency center should simultaneously equip critical-line in order to communication with each other. Ordinary ambulance and secondary emergency facility should also simultaneously equip emergency-line in order to communication with each other. 4) Emergency care facilities. Primary emergency care facilities should be covered with the ambulatory emergency patients-minor illness and injuires. Secondary emergency care facilities should be covered with the emergency admission patients. Third emergency care center should be covered with the critical patients who need special treatments and operation. Secondary and third emergency care facilities should employ emergency medical doctor and emergency nurse specialist to treat in-patients with severe and acute illness and multiple injuires. It should be fashioned for a system of emergency facilities that meets emergency patients needs. Provide incentives for increased number of emergency care facilities with traning in personal/clinical emergency care. 5) Finance It is recommended to put the finance of a emergency care on a firm basis. The emergency care delivery system should be managed by the government or accreditted organizations. In order to facilitate this relevant program the fund is needed for more efficient and effective emergency researchs, service, programs, and policy. 6) Gaining understanding and co-operation of pubic It is also important to undertake pubic education to improve understanding of first aids and C. P. R of individuals, communities and business. It is proposed that teachers and health officers be certified in C. P. R. The C. P. R education can be powerful influence save lives. Lastly appropriate emergency care information must be provided to the pubic for assisting them in choosing emergency care.

  • PDF

The Location of Medical Facilities and Its Inhabitants' Efficient Utilization in Kwangju City (광주시(光州市) 의료시설(醫療施設)의 입지(立地)와 주민(住民)의 효율적(效率的) 이용(利用))

  • Jeon, Kyung-Sook
    • Journal of the Korean association of regional geographers
    • /
    • v.3 no.2
    • /
    • pp.163-193
    • /
    • 1997
  • Medical services are a fundamental and essential service in all urban areas. The location and accessibility of medical service facilities and institutions are critical to the diagnosis, control and prevention of illness and disease. The purpose of this paper is to present the results of a study on the location of medical facilities in Kwangju and the utilization of these facilities by the inhabitants. The following information is a summary of the findings: (1) Korea, like many countries, is now witnessing an increase in the age of its population as a result of higher living standards and better medical services. Korea is also experiencing a rapid increase in health care costs. To ensure easy access to medical consultation, diagnosis and treatment by individuals, the hierarchical efficient location of medical facilities, low medical costs, equalized medical services, preventive medical care is important. (2) In Korea, the quality of medical services has improved significantly as evident by the increased number of medical facilities and medical personnel. However, there is still a need for not only quantitative improvements but also for a more equitable distribution of and location of medical services. (3) There are 503 medical facilities in Kwangju each with a need to service 2,556 people. This is below the national average of 1,498 inhabitants per facility. The higher locational quotient and satisfactory population per medical facility showed at the civic center. On the other hand, problem regions such as the traditional residential area in Buk-Gu, Moo-deung mountain area and the outer areas of west Kwangju still maintain rural characteristics. (4) In the study area there are 86 general medicine clinics which provide basic medical services. i. e. one clinic per every 14,949 residents. As a basic service, its higher locational quotient showed in the residential area. The lower population concentration per clinic was found in the civic center and in the former town center, Songjeong-dong. In recently build residential areas and in the civic center, the lack of general medicine clinics is not a serious medical services issue because of the surplus of medical specialists in Korea. People are inclined to seek a consultation with a specialist in specific fields rather than consult a general practitioner. As a result of this phenomenon, there are 81 internal medicine facilities. Of these, 32.1% provide services to people who are not referred by a primary care physician but who self-diagnose then choose a medical facility specializing in what they believe to be their health problem. Areas in the city, called dongs, without any internal facilities make up 50% of the total 101 dongs. (5) There are 78 surgical facilities within the area, and there is little difference at the locational appearance from internal medicine facilities. There are also 71 pediatric health clinics for people under 15 years of age in this area, represents one clinic per 5,063 people. On the quantitative aspect, this is a positive situation. Accessibility is the most important facility choice factor, so it should be evenly located in proportion to demander distribution. However, 61% of 102 dongs have no pediatric clinics because of the uneven location. (6) There are 43 obstetrical and gynecological clinics in Kwangju, and the number of residents being served per clinic is 15,063. These services need to be given regularly so it should increase the numbers. There are 37 ENT clinics in the study area with the lower concentration in Dong-gu (32.4%) making no locational differences by dong. There are 23 dermatology clinics with the largest concentration in Dong-Gu. There are 17 ophthalmic clinics concentrated in the residential area because of the primary function of this type of specialization. (7) The use of general medicine clinics, internal medicine clinics, pediatric clinics, ENT clinics by the inhabitants indicate a trend toward primary or routine medical services. Obstetrics and gynecology clinics are used on a regular basis. In choosing a general medicine clinic, internal medicine clinic, pediatric clinic, and a ENT clinic, accessibility is the key factor while choice of a general hospital, surgery clinic, or an obstetrics and gynecology clinic, thes faith and trust in the medical practitioner is the priority consideration. (8) I considered the efficient use of medical facilities in the aspect of locational and management and suggest the following: First, primary care facilities should be evenly distributed in every area. In Kwangju, the number of medical facilities is the lowest among the six largest cities in Korea. Moreover, they are concentrated in Dong-gu and in newly developed areas. The desired number of medical facilities should be within 30 minutes of each person's home. For regional development there is a need to develop a plan to balance, for example, taxes and funds supporting personnel, equipment and facilities. Secondly, medical services should be co-ordinated to ensure consistent, appropriate, quality services. Primary medical facilities should take charge of out-patient activities, and every effort should be made to standardize and equalize equipment and facility resources and to ensure ongoing development and training in the primary services field. A few specialty medical facilities and general hospitals should establish a priority service for incurable and terminally ill patients. (9) The management scheme for the inhabitants' efficient use of medical service is as follows: The first task is to efficiently manage medical facilities and related services. Higher quality of medical services can be accomplished within the rapidly changing medical environment. A network of social, administrative and medical organizations within an area should be established to promote information gathering and sharing strategies to better assist the community. Statistics and trends on the rate or occurrence of diseases, births, deaths, medical and environment conditions of the poor or estranged people should be maintained and monitored. The second task is to increase resources in the area of disease prevention and health promotion. Currently the focus is on the treatment and care of individuals with illness or disease. A strong emphasis should also be placed on promoting prevention of illness and injury within the community through not only public health offices but also via medical service facilities. Home medical care should be established and medical testing centers should be located as an ordinary service level. Also, reduced medical costs for the physically handicapped, cardiac patients, and mentally ill or handicapped patients should be considered.

  • PDF

Comparison of Aviary, Barn and Conventional Cage Raising of Chickens on Laying Performance and Egg Quality

  • Ahammed, M.;Chae, B.J.;Lohakare, J.;Keohavong, B.;Lee, M.H.;Lee, S.J.;Kim, D.M.;Lee, J.Y.;Ohh, S.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.8
    • /
    • pp.1196-1203
    • /
    • 2014
  • This study intended to compare the productive performance of three different layer raising systems; conventional cage (CC), barn (BR) and aviary (AV). The AV is welfare bestowed housing that allows free locomotion for birds within the BR. The BR allows bird's free locomotion inside BR but without multilevel structures. Both pullets and cockerels were housed together in both AV and BR, but only pullets in CC. Seventeen weeks old Lohmann Brown Lite (n = 800) pullets were housed in AV during this study. The same age layer pullets were simultaneously assigned to either at CC or BR to compare egg production performance with AV. The duration of experiment was 40 weeks (from 21st to 60th week). There were no remarkable differences in egg production, hen day egg production (HDEP) and average egg weight among three rearing systems. First 20 weeks (phase-1) average HDEP (%) of AV, CC, and BR were 85.9, 88.8, 87.1 and average egg weights (g) were 57.5, 59.9, and 56.9 respectively. Those of the remaining 20 weeks (phase-2) were 87.1, 87.9, 85.5 and 64.2, 63.0 62.1, respectively. Daily feed intakes (122 g, 110 g, 125 g); feed conversion ratio (2.4, 2.1, 2.5) and daily egg mass (53.9 g, 54.4 g, 52.8 g) data from AV, CC, and BR were not influenced significantly by the respective raising systems. Daily feed intake of layers in both AV (124 g) and BR (127 g) tended to be higher than that in CC (113 g) during phase-2. Overall, exterior egg quality (dirty and cracked eggs) in both phases was superior in BR compared with AV and CC, whereas CC generated intermediate results. This study indicated that the HDEP per se in AV and BR were not significantly different from that in CC. The study implied that the facility depreciation cost for AV and cost for increased feed intake in AV compared to CC are believed to be critical to evaluate the cost effectiveness of egg production in AV.

How IT Drives Innovations for Public Service: Mobile Office for Seoul Metropolitan Railway (IT 기반의 공공서비스 혁신: 서울도시철도공사의 모바일 오피스 사례)

  • Cho, Nam-Jae;Choi, Joung-In;Oh, Seung-Hee
    • Information Systems Review
    • /
    • v.14 no.1
    • /
    • pp.67-84
    • /
    • 2012
  • Recent increases in uncertainty and speed of market change are driving the adoption of new intelligent mobile office systems. Organizational information systems paradigm suggests that a right match between organizational characteristics and the use of technology is critical in producing desired results. Following such perspective this study developed the mobile office system case of Seoul Metropolitan Railway Transit(SMRT) in Korea. SMRT developed the mobile task-supporting environment that help the management of subway lines real-time without the restriction of time and space. They named the system as ST&F(SMRT Talk and Flash). They decided to develop the application systems in-houses they did not want to be overly dependent on external services in future changes and developments of the system. The new practice reduced the time for moving back and forth to 10% of their working time from previous 20%. The time used for paper works and administration chore also reduce to 10% of their working time from previous 30% on the average. The employees could use 80% of their time to concentrate on the completion of assigned task. The effects of this improvement resulted in the heightened efficiency of the use of human resources and the heightened level of railway safety. The case of SMRT shows that the mobile office system can be applied and extended to various business areas such as facility management and maintenance beyond such typical uses as sales and marketing support. Also, The result of case study will be a useful guideline on the construction and using of mobile office system.

  • PDF

Humidifier disinfectant lung injury, how do we approach the issues?

  • Choi, Jihyun Emma;Hong, Sang-Bum;Do, Kyung-Hyun;Kim, Hwa Jung;Chung, Seockhoon;Lee, Eun;Choi, Jihyun;Hong, Soo-Jong
    • Environmental Analysis Health and Toxicology
    • /
    • v.31
    • /
    • pp.19.1-19.7
    • /
    • 2016
  • A large portion of the Korean population has been exposed to toxic humidifier disinfectants (HDs), and considering that the majority of the victims are infants, the magnitude of the damage is expected to be considerably larger than what has currently been revealed. The current victims are voicing problems caused by various diseases, including but not limited to lung, upper respiratory tract, cardiovascular, kidney, musculoskeletal, eye, and skin diseases, etc. However, there has been difficulty in gaining validation for these health problems and identifying causal relationships due to lack of evidence proving that toxic HD is the specific causes of extrapulmonary diseases such as allergic rhinitis. Furthermore, the victims and bereaved families of the HD case have not received any support for psychological distress such as post-traumatic stress disorder, depression, feelings of injustice, and anger caused by the trauma. In addition, because the underlying mechanisms of the toxic materials within the HDs such as polyhexamethylene guanidine phosphate, poly(oxyalkylene guanidine) hydrochloride, chloromethylisothiazolinone /methylisothiazolinone have yet to be determined, the demand for information regarding the HD issue is growing. The victims of the HD cases require support that goes beyond financial aid for medical costs and living expenses. There is a desperate need for government-led integrated support centers that provide individualized support through health screenings; in other words, we need an integrated facility that provides the appropriate social support to allow the victims to recover their physical and mental health, so as to well prepare them to return to a normal life. The implementation of such a plan requires not only the close cooperation between those departments already directly involved such as the Ministry of Environment and the Ministry of Health and Welfare, but also active support on a national scale from pan-governmental consultative bodies.

Estimation of Water Production Cost from Seawater Reverse Osmosis (SWRO) Plant in Korea (국내 해수담수화 플랜트 생산수 단가 추정)

  • Hwang, Moon-Hyun;Han, Doseon;Kim, In S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.169-179
    • /
    • 2017
  • This study was conducted to supply information that can be utilized as data for desalination plant construction in the future by estimating unit cost of water production in the potential site of Incheon, Daesan, Yeosu, Busan, Ulsan and Sokcho in Korea. The production costs in Sokcho and Ulsan were similar to those of Busan and Yeosu. Those four sites showed better economic range due to low construction cost for intake facility compared to Incheon and Daesan. Although the salinity measured in the above 6 sites did not show perceptible effect on the production cost, the difference of seasonal seawater temperature needs to be considered due to the change of flux in reverse osmosis (RO) membrane. It turned out that the most critical parameters are the amortization in a year by the analysis of life cycle and the capacity of plant. Incheon and Daesan showed the difference of production cost up to 29% at the condition of amortization in 25 year, and up to 22% depending on plant capacity. However, the production cost in this study did not take into account of other indirect costs, therefore, this should be considered as the minimum cost.