• Title/Summary/Keyword: Criterias and Indicators

Search Result 4, Processing Time 0.019 seconds

A Study to the Applicability of Forest Function Type by Criterias and Indicators for Sustainable Forest Management (지속가능한 산림경영을 위한 기준 및 지표의 산림기능구분에 대한 적용성 연구)

  • Woo, Jong-Choon;Jang, Jae-Young;Shin, Hyun-Ji
    • Journal of Forest and Environmental Science
    • /
    • v.21 no.1
    • /
    • pp.1-15
    • /
    • 2005
  • To be a sustainable forest management, Korea took a Montreal process in many processes. This study applied seven criterias, twenty-seven indicators that are applicable indicators to the forest function type. Forest function type choose representation, suitability, possibility criterias and indicators that forest conditions are thought a great deal of wegit on the forest by a goal. And we can't estimate many forest with same criteria and indicators every time, to apply them need correct data and knowledge about forest.

  • PDF

Development of and Evaluation Tool for the Quality of Patient Care in Musculo-skeletal Disorder (${\cdot}$ 골격장애 환자의 간호질 평가 도구 개발)

  • Choi, Soon-Ook;Kim, Moon-Sil
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.1 no.2
    • /
    • pp.338-348
    • /
    • 1995
  • We need to continuously evaluate for nursing quality and the outcome to reflect nursing, to repair and improve of nursing. The first problem for nursing quality improvement is development of evaluation tool for the quality of nursing care. We need a system for quality assurance evaluation that is, development and framework of evaluation tool for nursing care quality. The purpose of this study was attempted to develop an evaluation tool for the quality of nursing care in musculoskeletal disorder patients. The approach method of nursing quality for the development of the tool in this study was process evaluation framework. The study were devided dvelopment process and reliability, validity verification process. The subjects of development process of this tool are three nursing export groups, and the subject of reliability, validity verification process are 20 samples of two university hospital in seoul, who were within discharge 3 months after admission treatment in musculo-skeletal disorder. Data for this study was collected from March 10 to April 13, 1995. The development process of the tool were as follows : 1. Make preliminary list of the tool by focal group were constituted 12 clinical nurses. 2. Modify and add preliminary list by 4 nursing expert panel. 3. Calculate content validity of the tool by 25 nursing expert panel of judge. 4. Verify reliability and validity of the tool. 5. Finalize an evaluation tool for the quality of the nursing care in musculo-skeletal disorder. The results of this study were as follows : 1) Development an evaluation tool for the quality of nursing care in musculo-skeletal disorder. (1) The evalution tool of this study was developed 5 standards, 33 criterias and 133 indicators. (2) 5 standards were divided according to Nursing Process. from standard 1 to standard 5, involved criterias were each 6(18%), 3(9%), 3(9%), 15(46%), 6(18%). 2) Verify reliability and validity of the tool. (1) Score of adequate degree for content validity of 33 criterias and 133 indicators were every average 2.82. (2) Inter-rater reliabilities(consentaneity score) of the tool by pearson correlation coefficient between three raters were : r=.7506, r=.8934, r=.6695. and Inter-rater reliabilities by single-facet crossed design were : r=.7464. (3) The alpha coefficient relating to internal consistency was .8524 over all 30 items of 33 criterias of developed tool. (4) Score of the quality of nursing care following to generaal characteristics of this study subjects were stastically significant differences according to educational level (F=2.93, p=.029)and diagnosing classification (F=2.50, p=.042). Through this study, I'm sure that the developed tool for the quality of patient care in musculo-skeletal disorder will show the way of more improvement of the quality of nursing care and effective nursing interventions.

  • PDF

Development of an evaluation tool for the quality of nursing care in neurosurgical intensive care unit patients (신경외과 중환자 간호의 질평가 도구개발)

  • Kim, Nam-Young;Jang, Keum-Seong
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.7 no.2
    • /
    • pp.285-300
    • /
    • 2001
  • To meet standards for high quality of care and satisfied customers, an evaluation tool about nursing care is necessary. And, We need to evaluate our practice continuously for the improvement in quality and outcomes. This study was intended to develop an evaluation tool about nursing care in NSICU, and was progressed of 3 steps; development, content validity verification and reliability verification. Data were obtained and analysed from Feb. To April, 2000. Development process of the study was as follows A preliminary list was made item by item on the basis of clinical Experience, literature review and patients' record review. Then the standards, criteria and indicators of preliminary evaluation tool were set by 5 clinical nursing panel, and their content validity was reviewed by 27 ICU nurses. Finally, an evaluation tool was developed and verified the reliability at c-university hospital located in Kwang-Ju. The results of this was as follows 1) The evaluation tool of this study developed 8 standards, 39 criterias and 106 indicators. The standards were divided into two dimensions. One was process dimension which contained 4 standards(26 criteria), The other was outcome dimension which contained 4 standards(13 criteria). 2) the Average content validity of the tool was 3.39 at standards, 3.55 at criteria and 3.51 at indicators. 3) Interrater reliability of the tool is r=.7993(p<.001) & internal consistency reliability ${\alpha}$ is .6031 4) Scores of NSICU Patients who participated in this study were 57 at total mean score, 58 at process mean score and 56 at outcome mean score The evaluation tool developed in this study seems to be useful in evaluation nursing practice appropriately for the improvement of nursing care in NSICU. I hope that this evaluation tool can be used effectively in NSICU as an intervention for the improvement of quality control.

  • PDF

Development of An Evaluation Tool for the Quality of Patient Care Chonic Renal Failure (만성 신부전 환자간호의 질평가 도구개발)

  • Yang, Young-Ock;Kim, Moon-Sil
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.2 no.1
    • /
    • pp.57-72
    • /
    • 1996
  • Provision of better nursing care to patients is a difficult but important task. The first problem for nursing quality improvement is development of evaluation tool for the quality of nursing care. This study tries to develop a patient care tool for patients with chronic renal failure. This study as a procedural evaluation of patient care, tries to show what, how, at what order to provide care to patients with chronic renal failure. This study is divided into process of development of tool, its reliability and validity. Among process of development of tool is focal group, small expert group and expert evaluation group. To develop approprieteness of tool, nurses working is four major hospitals is Seoul were selected. To evaluate the credibility of subjects, 19 patient who were hospitalized and discharged within 3 months were selected. The period for collecting data for reliability and valiability evaluation was between Sept. 20 to Oct. 18, 1995. The development process of this study is as follows ; 1. Make preliminary list of the tool by focal group consisting of 8 clinical nurses. 2. Modify and add preliminary list by 4 expert nursing panel. 3. Calculate content validity of the tool by 23 nursing expert panel of judge. 4. Verity relability and validity of the tool. 5. Finalize an evaluation tool for the quality of nursing care in chronic renal failure patient. The result of this study were as follows ; 1. Development of evaluation tool for the quality of nursing care in chronic renal failure. 1) The evaluation of this study was developed 5 standards, 28 criteria. and 130 indicators 2) Nursing care evaluation scores for chronic renal failure patients were average 68.8. 2. Verity reliability and validity of the tool. 1) 5 standards were divided into 4 point scale and according to 28 creteria, indicators of standard were 3.72 and of criteria were 3.77 2) Inter - rater reliability (consentaneity score) of the tool by pearson correlation coefficient betwwen rates were r= .72, r= .75 and interreliabilities by single - facet crossed design were r= .96. 3) The alpha coeffecient relating to internal consistency was .7259 over 27 items of 28 criterias of developed tool. Through this study, I'm sure that the developed tool for the quality of patient care in chronic-renal failure patient will show the way of more improvement of the quality of nursing care and effective nursing intervention.

  • PDF