• Title/Summary/Keyword: Crestal bone

Search Result 125, Processing Time 0.027 seconds

The FEM Analysis on the Crestal Cortical Bone around the Implant according to the Cancellous Bone Density and Loading Positions (임프란트 매식시 해면골질의 차이에 따른 치밀골 상 응력분석)

  • Jeung, Sin-Young;Kim, Chang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • This study was performed to compare the stress distribution pattern in the crestal cortical bone and cancellous bone using 3-dimensional finite element stress analysis when 2 different Young's modulus(high modulus, model 1; low modulus, model 2) of cancellous bone was assumed. For the analysis, a finite element model was designed to have two square-threaded implants fused together and located at first and second molar area. Stress distribution was observed when vertical load of 200N was applied at several points on the occlusal surfaces of the implants, including central fossa, points 1.5mm, 2mm, 3mm and 3.5mm buccally away from central fossa. The results were as follows; 1. In both model, the maximum Von-Mises stress in the crestal cortical bone was greater when the load was applied at the central point, points 1.5mm and 2mm buccally away from central fossa than other cases. 2. In the cortical bone around first and second molar, model 2 showed greater Von-Mises stress than model 1. It is concluded that when the occlusal contact is afforded, the distribution of stress varies depending on the density of cancellous bone and the location of loading. More favorable stress distribution is expected when the contact load is applied within the diameter of fixtures.

Periimplant bone change after alveolar ridge preservation: radiographic retrospective study (발치와 치조제 보존술 후 식립한 임플란트 주위 골 변화: 후향적 방사선학적 분석)

  • Shim, Da-Eun;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.281-290
    • /
    • 2021
  • Purpose. The aim of this study is to evaluate bone change around the implant in patients who underwent alveolar ridge preservation for implantation in the posterior teeth using radiographic data measuring changes of mesial, distal crestal bone level according to post-implantation, post-final prosthesis delivery and follow-up periods. Materials and methods. In total, 36 implants were placed in 32 patients. The mesial and distal crestal bone level of all the areas where alveolar ridge preservation was performed uses panoramic images taken post-implantation, post-final prosthesis delivery, and follow-up period each was measured and evaluated as a vertical value. The following factors were analyzed: associations between changes of crestal bone level and factors (e.g., age, sex, systemic diseases, dentist, implant location, tooth, bone type, membrane). The statistical analysis was performed using the mean, standard deviation and independent t-test, paired t-test (P < .05). Results. Analysis of crestal bone level differences between periods shows statistically significant differences (P < .05). There was no statistically significant difference when the changes of crestal bone level between post-implantation, post-final prosthesis delivery and follow-up periods were correlated with each factors. Conclusion. After alveolar ridge preservation, bone around the implant remained stable during the maintenance period without being affected by the patient and surgical factors, and alveolar ridge preservation is considered a clinically usable procedure.

Predictability of simultaneous implant placement with sinus floor elevation in the severely atrophic posterior maxillae ; Comparison of lateral and trans-crestal approaches (지상보수교육강좌 1 - 상악동저 거상술을 동반한 임프란트 동시 식립의 예지성 평가; 측방접근술과 치조정접근술의 비교)

  • Kim, Yeong-Wook;Keum, Yoon-Seon;Son, Hyo-Jeong;Lee, Jang-Yeol;Kim, Hyoun-Chull;Lee, Sang-Chull
    • The Journal of the Korean dental association
    • /
    • v.48 no.3
    • /
    • pp.205-217
    • /
    • 2010
  • Purpose The aim of this study is to evaluate the survival rates and analyze the stability of lateral approach and trans-crestal approach for maxillary sinus floor elevation of simultaneous implant placement. Materials and method 407 patients who have been treated in LivingWell dental hospital between 2003 to 2009 were selected. Lateral window technique, osteotome technique and sinus drill technique were used for sinus floor elevation procedure. A total of 714 implants-MP-1 HA coated implant(Tapered Screw $Vent^{TM}$, $Spline^{TM}$, Zimmer, USA), FBR surfaced implant(Pitt-$Easy^{TM}$, Oraltronics, Germany)-were placed in grafted maxillary sinus simultaneously. The autogenous bone or a combination with the allograft or alloplast was grafted into sinus. Sinus floor elevation was combined with vertical/horizontal onlay bone grafts to reconstruct the defect of alveolar ridge. Results The average preoperative height of the maxillary alveolar bone was 5.78mm(range: 0.4mm~12.5mm). 14 implants failed during the healing period(lateral approach: 4, trans-crestal approach: 10) and 3 implant failed after prosthetic loading(lateral approach: 2, trans-crestal approach: 1). The cumulative survival rate of implants after 6 years was 97.6%. Trans-crestal approach(97.4%) and lateral approach(97.9%) had similar survival rates. Conclusion The results indicate that the trans-crestal approach and lateral approach for maxillary sinus elevation is a acceptable method at atrophic maxillary posterior area.

RADIOGRAPHIC EVALUATION OF THE PROXIMAL BONE LEVEL BETWEEN TWO IMPLANTS : A 3-YEAR COMPARATIVE STUDY BETWEEN BR$BR{\AA}$NEMARK AND ITI IMPLANTS IN THE MANDIBULAR POSTERIOR REGION (하악 구치부에 식립된 Br${\aa}$nemark 임프란트와 ITI 임프란트에서 임프란트간 치조정간골의 높이변화에 대한 방사선학적 비교)

  • Yi, Sang-Hwa;Cha, In-Ho;Shim, June-Sung;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.458-470
    • /
    • 2004
  • Statement of problem: Br${\aa}$nemark or ITI are two currently most widely used implant systems but with contrasting design, surgical and restoration methods. Purpose: The purpose of this study was to compare changes and its statistical significance in bone height and shape which may rise due to the differences between two implant systems. Also to analyse the effect of inter-implant distance on annual bone height changes. Material & Method: Those patients who were treated with two or more of either Br${\aa}$nemark or ITI implants at posterior mandibular area at Yonsei University Dental Hospital, Implant Clinic were selected. At annual examination appointments, standardised radiographs using parallel technique were taken. Marginal bone and inter-implant crestal bone changes were measured and following results were obtained. Results: 1) When ITI and Br${\aa}$nemark system were compared, both annual marginal and inter-implant crestal bone height changes in ITI system in the first two years were smaller than Br${\aa}$nemark and they were statistically significant. On the third year, however, there was no statistical difference between two implant systems on their annual bone level changes (p>0.05). 2) The Marginal and inter-implant crestal bone changes were compared when inter-implant distance was less than 4mm. Statistically significant bone level changes were noted on the first year only for ITI implants but in the first and second year for Br${\aa}$nemark implants (p>0.05). 3) When comparing angulation changes between marginal bone and implant fixture, ITI system had smaller angulation changes but the annual changes were not statistically significant (p>0.05). Conclusion: Within the limitation of this study, it could be concluded that Br${\aa}$nemark implant systems had more changes in marginal and inter-implant crestal bone level in the first and second year after loading with statistical significance. Further studies are recommended to see the effects of these bone loss during the first and second year after loading on the long term prognosis of Br${\aa}$nemark Implants.

Evaluation of the Availability of Implant placement using Ridge Expansion Osteotomy (REO) (치조능확장골절단술을 이용한 임프란트 식립술의 유용성 평가)

  • Kim, Yeong-Gyun;Yun, Pil-Yeong;Kim, Beom-Su
    • The Journal of the Korean dental association
    • /
    • v.46 no.4
    • /
    • pp.243-247
    • /
    • 2008
  • Purpose : Ridge expansion osteotomy (REO) has been introduced when it is necessary to expand narrow crestal ridge with simultaneous implant placement. This study has designed to evaluate the clinical availability of REO. Materials and methods : Subject were patients who had visited Seoul National University Bundang Hospital from July. 2003 to December, 2005 for implant placement using REO by one surgeon. Intraoperative and postoperative complication, failure of initial osseointegration and marginal bone resorption were estimated using electronic medical record and periapical radiography. Twenty?three patients, 8 males and 15 females, mean age 51, ranged 18 to 72, were treated for mean 26 months, ranged from 16 months to 46 months. Results : Mean diameter and length of implants placed at upper anterior, were 3.72mm and 13.32mm each other. Guided bone regeneration and ridge splitting were accompanied in this study. Five cases of cortical bone fracture, three cases of crestal bone loss more than 2mm, 2cases of gingival recession, and 2 cases of infection were noted, but there were no implants removed because of disintegration. Success rate of implant was 91.7%, even if survival rate of implant was 100%. In addition, there were no statistical significance between the success rate of REO and bone graft(p>0.05). Conclusion : Based on the results of the present study, it can be concluded that REO technique is reliable for implant placement at atrophic ridge with adequate height compared to bone graft and other osteotomies for ridge expansion, but care should be taken of esthetic problem such as gingival recession because of crestal bone resorption from trauma by osteotome.

  • PDF

The influence of screw type and osseointegration ratio on stress distribution in two different endosseous implants

  • Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.348-357
    • /
    • 2000
  • The purpose of this study is to examine the effect of partial osseointegration situation on bone loading patterns around two different free-standing screw shaped implants (Nobel Biocare, Gothenburg, Sweden and Degussa-Huls, Hanau, German). Two dimensional axisymmetric Finite element models of two implants(10mm length and 4mm diameter) were created according to different bone quantity, quality and osseointegration ratio in maxilla and mandible bone. At the same time uni-cortical and hi-cortical fixation were analyzed. Generally, full bond case showed less stress than partial bond case in overall area and mandibular model showed less amount of stress than that of maxilla model. Maximum stress of the Branemark implant is higher than that of ANKYLOS regardless of bonding ratio at crestal and apex region. However, more stress concentration was noted in ANKYLOS implant at screw body area especially in mandible. The effect of bicortical fixation on crestal bone stress reduction is dramatical in mandible however, there was no significant effect in maxillary case. The effect of partial bond on stress distribution was more significant at screw body and apex region than in crestal region. Partial bond cases demonstrated greater stress accumulation in trabecular bone than cortical bone. It is concluded that the more accurate model of implant and bone which affects stress and strain distribution is needed to mimic in vivo behavior of implants.

  • PDF

Analysis of factors affecting crestal bone loss around the implants

  • Park, Ji-Hoon;Kim, Young-Kyun;Yun, Pil-Young;Yi, Yang-Jin;Yeo, In-Sung;Lee, Hyo-Jung;Park, Jin-Young
    • Journal of Korean Dental Science
    • /
    • v.2 no.2
    • /
    • pp.12-17
    • /
    • 2009
  • Purpose : To determine whether peri-implant crestal bone loss could be affected by systemic disease, primary ISQ value, implantation method (submerged vs. non-submerged), surface treatment, and bone density Materials and methods : Patients who underwent fixture installation from June 24, 2005 to October 23, 2008 at Seoul National University Bundang Hospital were evaluated. A total of 157 patients (male: 52, female: 85) had 346 fixtures installed. Among them, 49 patients had periapical radiographs taken 1 year after prostheses were first set. A total of 97 fixtures were implanted. In particular, 30 fixtures were installed in patients with systemic diseases such as diabetes mellitus, cardiovascular disease, hypertension, and liver disease. The immediate stability of implants was measured with $Osstell^{tm}$. Implant surface treatment was classified into two groups (RBM, Cellnest (Anodized)), and bone density, into four groups (D1~D4). The bone resorption on the mesial and distal areas of fixtures was measured with periapical radiographs using the paralleling technique, and the mean value was calculated. The length determination program in IMPAX (AGFA, Belgium) was used. Results : At least 332 out of 346 (96%) installed GS II implants were successfully osseointegrated 1 year after prostheses were first set. The mean value of the bone resorption of the installed GS II implants was 0.44mm. The minimum value was 0mm, and the maximum value, 2.85mm. There was a statistically significant difference between the implantation methods (submerged, non-submerged) with regard to the amount of alveolar bone loss 1 year after prostheses were first set (p<0.05). Non-submerged implants showed less crestal bone loss. Note, however, that other variables had no correlation with crestal bone loss (p>0.05). Conclusion : There was a statistically significant difference between the 1-stage method and 2-stage method with regard to the amount of alveolar bone loss 1 year after prostheses were first set. Systemic disease, primary ISQ value, surface treatment, and bone density were not associated with alveolar bone loss. Other variables were assumed to have a correlation with alveolar bone loss.

  • PDF

A 2-Year Longitudinal Study of Untreated Periodontal Disease in Young Adults (20대의 치주염 진행에 대한 2년간의 종적연구)

  • Um, Heung-Sik
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.3
    • /
    • pp.523-531
    • /
    • 1998
  • The purpose of this investigation was to examine the pattern of progression of periodontitis and the change in the extent and severity of the periodontal condition in young adults. Fourteen subjects with periodontitis, 11 males and 3 females in the age range 22-26, participated in the study. Following a baseline examination, the subjects were monitored for gingival index, probing pocket depth, gingival recession, probing attachment level and radiogrphic crestal bone height for 24 months without therapy. Re-examination were performed after 12 and 24 months. Gingival index, probing pocket depth, gingival recession and probing attachment level were assesed at 6 locations per tooth, and crestal bone height was assessed by subtraction radiography. The results from the follow-up examination revealed that the subjects underwent minor changes with respect to a series of different clinical parameters. The mean values of gingival index was improved, however, the mean values of probing pocket depth, gingival recession, probing attchment level and crestal bone height showed no significant change between baseline and the re-examination after 1 and 2 years.

  • PDF

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE EFFECT OF CORTICAL ENGAGEMENT ON IMPLANT LOAD TRANSFER IN POSTERIOR MANDIBLE (하악구치부 피질골 engagement가 임플란트 하중전달에 미치는 영향에 관한 3차원 유한요소법적 응력분석)

  • Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.607-619
    • /
    • 1999
  • Cortical support is an important factor, as the engagement of the fixture in strong compact bone offers an increased load-carrying capacity and initial stability. Because of the poor bone quality in the posterior mandible and other anatomic considerations, it has been suggested that implant fixtures be placed in these locations with apical engagement of the lingual cortical plate for so-called bicortication. The purpose of this investigation was to determine the effect of cortical engagements and in addition polyoxymethylene(POM) intramobile connector(IMC) of IMZ implant on implant load transfer in edentulous posterior segment of mandible, using three-dimensional (3D) finite element analysis models composed of cortical and trabecular bone involving single implant. Variables such as (1) the crestal peri-implant defect, (2) the apical engagement of lingual cortical plate, (3) the occlusal contact position (a vertical load at central fossa or buccal cusp tip), and (4) POM IMC were investigated. Stress patterns were compared and interfacial stresses along the bone-implant interface were monitored specially. Within the scope of this study, the following observations were made. 1) Offset load and angulation of fixture led to increase the local interfacial stresses. 2) Stresses were concentrated toward the cortical bones, but the crestal peri-implant defect increased the interfacial stresses in trabecular bone. 3) For the model with bicortication, it was noticed that the crestal cortical bone provided more resistance to the bending moment and the lingual cortical plate provided more support for the vertical load. But Angulation problem of the fixture from the lingual cortical engagement caused the local interfacial stress concentrations. 4) It was not clear that POM IMC had the effect on stress distribution under the present experimental conditions, especially for the cases of crestal peri-implant defect.

  • PDF

Evaluation of platform switching and its clinical application (Platform switching(또는 Platform shifting) 개념 및 임상적용에 관한 고찰)

  • Yang, Byoung-Eun;Song, Sang-Hun;Kim, Seong-Gon
    • The Journal of the Korean dental association
    • /
    • v.45 no.9 s.460
    • /
    • pp.562-570
    • /
    • 2007
  • Many dentists and patients expect that implant function and esthetics will not change over time. However, even the most successful implant restorations with ideal position, vertical height, and occlusion can be aesthetically pleasing, but may hide a common problem. Many dentists noticed that there can be some circumferential bone loss around the neck of the implants. To circumvent this bone loss, a "platform switching" concept was introduced recently. The basic concept of platform switching is by moving the fixture-abutment interface further away from the crestal bone to minimize crestal bone loss. Since crestal bone loss is a multifactor problem, it is important to consider microgap formation and micromotion between the implant and abutment because platform switching does not solve the problem on its own. In this article, we reviewed studies concerning platform switching and discussed the clinical application and the problems that may occur with its use.

  • PDF