직접Quenching 열간 단조용 비조질강의 기계적 성질에 미치는 Quenching온도 및 냉각속도의 영향 (Effect of Quenching Temperature and Cooling Rate on the Mechanical Properties of Direct Quenched Micro-Alloyed Steel for Hot Forging)

  • 신정호;류영주;김병옥;고인용;이오연
    • 한국재료학회지
    • /
    • 제22권10호
    • /
    • pp.513-518
    • /
    • 2012
  • Recently, automobile parts have been required to have high strength and toughness to allow for weight lightening or improved stability. But, traditional micro-alloyed steel cannot be applied in automobile parts. In this study, we considered the influence of quenching temperature and cooling rate for specimens fabricated by vacuum induction furnace. Directly quenched micro-alloyed steel for hot forging can be controlled according to its micro structure and the heat-treatment process. Low carbon steel, as well as alloying elements for improvement of strength and toughness, was used to obtain optimized conditions. After hot forging at $1,200^{\circ}C$, the ideal mechanical properties (tensile strength ${\geq}$ 1,000 MPa, Charpy impact value ${\geq}\;100\;J/cm^2$) can be achieved by using optimized conditions (quenching temperature : 925 to $1,050^{\circ}C$, cooling rate : ${\geq}\;5^{\circ}C/sec$). The difference of impact value according to cooling rate can be influenced by the microstructure. A fine lath martensite micro structure is formed at a cooling rate of over $5^{\circ}C/sec$. On the other hand, the second phase of the M-A constituent microstructure is the cause of crack initiation under the cooling rate of $5^{\circ}C/sec$.

일방향 및 평직 CF/Mg 복합재 적층판의 부식에 따른 미세조직 및 기계적 특성 변화 (Microstructure and Mechanical Property Changes of Unidirectional and Plain Woven CF/Mg Composite Laminates after Corrosion)

  • 임시온;이정무;이상관;박용호;박익민
    • 대한금속재료학회지
    • /
    • 제50권9호
    • /
    • pp.697-702
    • /
    • 2012
  • In this study, unidirectional and plain woven carbon fiber reinforced magnesium matrix composite laminates were fabricated by the liquid pressing infiltration process, and evolutions of the microstructure and compressive strength of the composite laminates under corrosion were investigated by static immersion tests. In the case of the unidirectional composite laminate, the main microstructural damage during immersion appeared as a form of corrosion induced cracks, which were formed at both CF/Mg interfaces and the interfaces between layers. On the otherhand, wrap/fill interface cracks were mainly formed in the plain woven composite laminate, without any cracks at the CF/Mg interface. The formation of these cracks was considered to be associated with internal thermal residual stress, which was generated during cooling after the fabrication process of these materials. As a consequence of the corrosion induced cracks, the thickness of both laminates increased in directions vertical to the fibers with increasing immersion time. With increasing immersion time, the compressive strengths of both composite laminates also decreased continuously. It was found that the plain woven composite laminates have superior corrosion resistance and stability under a corrosive condition than unidirectional laminates.

Laser Source 특성 분석을 통한 Low Depth Marking 공법 연구 및 고찰 (A Study on the Low Depth Marking Method through Laser Source Characteristic Analysis)

  • 전수호;김제호;이영범;문기일
    • 마이크로전자및패키징학회지
    • /
    • 제29권2호
    • /
    • pp.65-71
    • /
    • 2022
  • Mobile PKG Trend는 소형화와 더불어 고용량 제품 요구로 인해 Mold Top Margin 감소가 불가피한 상황이다. 하지만 기존 Laser Marking 공법은 Depth가 깊어 Narrow Top Margin 제품에 적용할 때 중첩 가공에 의한 PKG 강도 저하가 예상되며, Chip Damage와 같은 품질 불량으로 신뢰성이 저하되는 문제점이 있다. 따라서 본 연구에서는 Laser Source 특징 비교를 통해 Narrow Top Margin 제품에 대응할 수 있는 Low Depth Laser Marking 기술을 확보하였으며, PKG 개발 제품에 해당 기술을 적용하여 평가한 결과 Marking Depth 67% 감소와 PKG 강도 12%가 향상됨을 검증하였다. 또한 PKG Mechanical 분석을 통해 발생 가능한 Laser Damage 품질 검증을 진행하였고, Chip Damage(Crack/Chipping) 불량은 발견되지 않았다. 이를 통해 양산 적용 품질 안정성을 확보하였다.

비선형 유한요소해석을 이용한 조립식 교각의 성능 평가 (Evaluation of Structural Performance of Precast Prefabricated Bridge Column using Nonlinear Finite Element Analysis)

  • 정철헌;윤연석;황은정
    • 대한토목학회논문집
    • /
    • 제28권3A호
    • /
    • pp.383-390
    • /
    • 2008
  • 교량의 하부구조에 프리캐스트 공법을 적용하기 위해 제안된 조립식 교각은 강관과 강봉을 연결구조로 활용하였으며, 강봉에 긴장력을 도입하여 교각의 일체화를 도모하였다. 제안된 조립식 교각 시스템을 적용하여 교각 실험체를 제작하였으며, 준정적 실험을 수행하였다. 실험결과, 교각 실험체의 파괴모드는 휨파괴로 나타났으며, 이음부에서의 손상은 발생하지 않았다. 또한 강봉에 도입된 긴장력으로 변형에 대한 복원능력이 우수하며, 교각의 연성능력이 내진설계기준을 만족하는 것을 확인하였다. 실험체를 대상으로 비선형 유한요소해석을 수행하였으며, 해석기법의 타당성을 검증하였다. 조립식 교각의 하중-변위 관계와 균열발생 위치에 대한 해석결과가 실험결과와 일치함을 확인함으로서 해석방법의 타당성을 확인하였다. 조립식 교각의 강재비, 강봉에 도입되는 긴장력, 콘크리트의 강도를 변수로 하여 비선형유한요소해석을 수행하였다. 해석결과를 통하여 제안된 조립식 교각 시스템의 적절한 수준의 강재비와 강봉에 도입되는 긴장력 등을 정성적으로 평가하였다.

첨단기술을 활용한 시설물 점검 및 진단 기술 검·인증을 위한 성능평가 방법론 (Performance Evaluation Method for Facility Inspection and Diagnostic Technologies)

  • 이영호;배성재;정욱;조재용;홍성호;남우석;김영민;김정렬
    • 한국재난정보학회 논문집
    • /
    • 제16권1호
    • /
    • pp.178-191
    • /
    • 2020
  • 연구목적: 본 연구는 시설물 점검 및 진단분야에 도입될 첨단 기술 및 장비의 동향을 조사하고 미국, 일본, 한국의 표준화 체계를 분석하여 국내 실정에 맞는 시설물 점검 및 진단장비 성능평가 방법의 기본 방향을 제시하고 성능평가 기준이 우선적으로 개발되어야 할 대상을 선정하는 것을 목적으로 한다. 연구방법: 시설물 점검 및 진단에 활용되는 첨단 장비 현황을 분석하기 위하여 시설물통합정보관리시스템(FMS)의 최근 5년간 보고서와 시설물 유지관리 업체와 안전진단전문기관에 소개된 첨단 기술을 조사하였다. 또한, NTIS에 등록되어 있는 과제, 논문, 연구보고서, 특허 등을 검색하였다. 이후 미국, 일본, 한국의 표준화 체계를 조사하여 국내 실정에 맞는 형태의 시설물 점검 및 진단장비 성능평가 방법의 기본 방향을 제시하고 전문가 인터뷰와 설문조사를 수행하여 성능평가 기준이 우선적으로 개발되어야 할 대상을 선정하였다. 연구결과: 자유로운 기술 개발이 이루어지고 지나친 제약이 되는 것을 방지하기 위하여 성능평가 프로세스는 조사항목별로 장비나 기술의 종류에 상관없이 해당 장비나 기술이 목표하는 점검에 대하여 요구되는 목표 성능지표를 개발하여 해당 성능지표를 만족할 경우 성능을 인증해 주는 방식으로 진행될 필요가 있다. 또한, 전문가 인터뷰와 설문조사 결과 내구성 평가의 콘크리트 균열 조사항목과 안전성 평가의 콘크리트/강재 변위/변형/피로 조사항목에 활용되는 첨단장비나 기술들을 대상으로 성능평가 기준을 우선적으로 개발해야 할 필요성을 확인하였다. 결론: 내구성 평가의 콘크리트 균열 조사항목이나 안전성 평가의 콘크리트/강재 변위/변형/피로 조사항목을 대상으로 성능평가 가이드라인을 우선적으로 개발할 필요성이 있으며, 자유로운 기술 개발을 도모하고 기존에 개발된 첨단장비에 새롭게 개발될 첨단장비의 성능을 공통된 기준으로 평가하기 위해서는 표준화된 시편이나 테스트 베드를 구축하여 기술 종류에 관계없이 제시된 요구 성능을 충족하면 성능을 인정하는 방식으로 검증하는 체계를 구축해야 한다.

프리캐스트 PSC 곡선 거더교의 구조거동에 대한 실험적 연구 (Experimental Study on Structural Behavior of Precast PSC Curved Girder Bridge)

  • 김성재;김성배;엄기하;김장호
    • 대한토목학회논문집
    • /
    • 제34권6호
    • /
    • pp.1731-1741
    • /
    • 2014
  • 교통수요의 증가에 따른 교통혼잡을 피하기 위하여 고가도로와 고속도로, 경전철 등이 활발히 건설되고 있으며, 이에 따라 접속부 등과 같은 곡률반경이 작은 곡선교 구간의 발생이 증가하고 있다. 초기에는 직선형의 주형을 연결하여 곡선을 이루는 방법을 사용하였으나, 공사비의 증가와 미관성 측면에서 용이하지 않아 강재를 사용한 곡선주형이 개발되어 적용되고 있다. 강재의 특성상 기하학적인 형상을 구현하는데 상대적으로 손쉽기 때문에 대부분의 곡선교에서는 강재를 이용한 강박스 거더교를 주로 사용하고 있다. 그러나 강박스 거더교는 초기 공사비가 고가이고, 도장과 같은 지속적인 유지관리가 필요한 문제점을 가지고 있다. 최근에는 I형 강재 플레이트 거더를 사용하는 방법이 활발히 연구되고 있으나 곡선 I형상의 특성상 개단면이고 얇은 플레이트를 사용하기 때문에 비틀림 강성이 매우 작아 안전성에 문제가 있는 것으로 지적되고 있다. 이러한 곡선강교의 대안으로 경제성과 안전성이 확보되는 프리캐스트 PSC 곡선거더가 제시되고 있다. 이에 본 연구에서는 프리캐스트 PSC 곡선거더를 효율적으로 제작할 수 있는 스마트 몰드 시스템을 개발하고 이를 적용한 2주형 40m 실물교량의 정적 휨 파괴 실험을 통하여 안전성을 확인하고자 한다. 제작단계에서 단일 거더는 곡률반경에 의해 거더의 전도에 대한 안정성이 문제가 있으나 가로보로 연결된 멀티거더는 하중분배가 적절히 이루어지며 안정성이 확보되는 것으로 나타났다. 정적구조 실험결과에서는 균열하중(1,400 kN)이 설계하중(450 kN)의 약 3배 이상 높은 것으로 나타났으며, 허용처짐량에 해당하는 하중은 설계하중의 4배인 1,800 kN에서 발생하여 사용성과 안전성이 모두 확보되는 것으로 나타났다.

지르코니아/알루미나 복합 지대주의 생물학적 안정성에 관한 연구 (Biological stability of Zirconia/Alumina composite ceramic Implant abutment)

  • 배규현;한증석;김태일;설양조;이용무;구영;조기영;정종평;한수부;류인철
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.555-565
    • /
    • 2006
  • The purpose of the present study is to evaluate the biological stability of the zirconia/alumina composite abutment by histologic and radiographic examination in clinical cases. 17 partially edentulous patients (5 men and 12 women, mean age 47) were treated with 37 implants. The implants were placed following the standard two-stage protocol. After a healing period of 3 to 6 months, zirconia/alumina composite abutments were connected. All radiographs were taken using paralleling technique with individually fabricated impression bite block, following insertion of the prosthesis and at the 3-, 6-, 12 month re-examinations. After processing the obtained images, the osseous level was calculated using the digital image in the mesial and distal aspect in each implant. An ANOVA and t-test were used to test for difference between the baseline and 3-, 6-, 12 months re-examinations, and for difference between maxilla and mandible. Differences at P <0.05 were considered statistically significant. For histologic examination, sample was obtained from the palatal gingiva which implant functioned for 12 months. Sections were examined under a light microscope under various magnifications. Clinically, no abutment fracture or crack as well as periimplantitis was observed during the period of study. The mean bone level reduction(${\pm}standard$ deviation) was 0.34 rom(${\pm}\;0.26$) at 3-months, 0.4 2mm(${\pm}\;0.30$) at 6-months, 0.62 mm(${\pm}\;0.28$) at 12-months respectively. No statistically significant difference was found between baseline and 3-, 6-, 12-months re-examinations (p > 0.05). The mean bone level reduction in maxilla was 0.33(${\pm}0.25$) at 3-months, 0.36(${\pm}0.33$) at 6-months, 0.56(${\pm}0.26$) at 12-months. And the mean bone level reduction in mandible was 0.35(${\pm}0.27$) at 3-months, 0,49(${\pm}0.27$) at 6-months, 0.68(${\pm}0.30$) at 12-months. No statistical difference in bone level reduction between implants placed in the maxilla and mandible. Histologically, the height of the junctional epithelium was about 2.09 mm. And the width was about 0.51 mm. Scattered fibroblasts and inflammatory cells, and dense collagen network with few vascular structures characterized the portion of connective tissue. The inflammatory cell infiltration was observed just beneath the apical end of junctional epithelium and the area of direct in contact with zirconia/alumina abutment. These results suggest the zirconia/alumina composite abutment can be used in variable intraoral condition, in posterior segment as well as anterior segment without adverse effects.

Strength and failure characteristics of the rock-coal combined body with single joint in coal

  • Yin, Da W.;Chen, Shao J.;Chen, Bing;Liu, Xing Q.;Ma, Hong F.
    • Geomechanics and Engineering
    • /
    • 제15권5호
    • /
    • pp.1113-1124
    • /
    • 2018
  • Geological dynamic hazards during deep coal mining are caused by the failure of a composite system consisting of the rock and coal layers, whereas the joint in coal affects the stability of the composite system. In this paper, the compression test simulations for the rock-coal combined body with single joint in coal were conducted using $PFC^{2D}$ software and especially the effects of joint length and joint angle on strength and failure characteristics in a rock-coal combined body were analyzed. The joint length and joint angle exhibit a deterioration effect on the strength and affect the failure modes. The deterioration effect of joint length of L on the strength can be neglected with a tiny variation at ${\alpha}$ of $0^{\circ}$ or $90^{\circ}$ between the loading direction and joint direction. While, the deterioration effect of L on strength are relatively large at ${\alpha}$ between $30^{\circ}$ and $60^{\circ}$. And the peak stress and peak strain decrease with the increase of L. Additionally, the deterioration effect of ${\alpha}$ on the strength becomes larger with the increase of L. With the increase of ${\alpha}$, the peak stress and peak strain first decrease and then increase, presenting "V-shaped" curves. And the peak stress and peak strain at ${\alpha}$ of $45^{\circ}$ are the smallest. Moreover, the failure mainly occurs within the coal and no apparent failure is observed for rock. At ${\alpha}$ between $30^{\circ}$ and $60^{\circ}$, the secondary shear cracks generated in or close to the joint tips, cause the structural instability failure of the combined body. Therefore, their failure models present as a shear failure along partial joint plane direction and partially cutting across the coal body or a shear failure along the joint plane direction. However, at ${\alpha}$ of $60^{\circ}$ and L of 10 mm, the "V-shaped" shear cracks cutting across the coal body cause its final failure. While crack nucleations at ${\alpha}$ of $0^{\circ}$ or $90^{\circ}$ are randomly distributed in the coal, the failure mode shows a V-shaped shear failure cutting across the coal body.

현장계측을 통한 지하증축공사 중 가설구조물의 거동 사례연구 (Behavior Case Study of Temporary Structures during Underground Extension Work by Field Measurement)

  • 김의석;민병찬;강민규;김동관;최항석
    • 한국지반환경공학회 논문집
    • /
    • 제21권8호
    • /
    • pp.5-13
    • /
    • 2020
  • 노후시설물의 지하공간 확장공사 시 공사 중 소음 및 진동 문제 뿐만 아니라 기존 주민의 임시 거주공간 확보가 필요하고, 상업용, 공업용, 사회용 등의 시설물의 경우에는 시설물 이용의 중단에 따른 피해가 예상되므로, 지하증축 공사 중 소음 및 진동을 최소화하여 공사 중에도 기존 시설물의 이용을 가능하게 하는 기술이 필요하다. 따라서 본 연구에서는 가설구조물의 안정성 문제와 공사 중 발생되는 소음진동 문제를 효과적으로 해결하여 지하증축 공사 중 시설물을 이용하면서 진행한 공사현장의 시공단계별 계측결과로 가설구조물과 주변지반의 거동을 분석하여 국내 현실에 적합한 지하증축공사 모델을 제시하였다. 시공 시 발생되는 문제를 해결하기 위해 초기 굴착 후 슬라브 선타설공법을 적용한 현장의 계측결과(건물경사계, 균열측정계, 구조물경사계, 지표침하계)를 확인한 결과 건물경사계와 구조물경사계는 슬라브 선타설후 변위가 감소하거나 수렴하는 경향을 확인할 수 있었으며, 균열측정계와 지표침하계는 관리기준 이내의 안정적인 모습을 확인할 수 있었다. 이 결과로 볼 때, 지하증축 공사 시 지하층 슬라브를 선타설하는 것은 공사 중 발생하는 소음·진동의 문제를 해결해주는 것 뿐만 아니라 지하증축 공사 시 가설구조물의 안정성을 확보하는데 큰 역할하고 있는 것을 확인할 수 있었다.

슬래그 골재를 사용한 10 mm 밀입도 아스팔트 혼합물의 골재입도 기준 연구 (A Study on Aggregate Gradation of 10 mm Dense-graded Asphalt Mixture using Slag Aggregate)

  • 조신행;김경남;김낙석
    • 대한토목학회논문집
    • /
    • 제35권6호
    • /
    • pp.1367-1375
    • /
    • 2015
  • 제강슬래그 골재를 사용한 박층 아스팔트 포장공법을 위해 10 mm 밀입도 아스팔트 혼합물의 골재 입도기준을 제시하고자 하였다. 기존 WC-1, WC-3과 같은 밀입도 아스팔트 혼합물의 골재 입도기준은 퓰러모델에 의해 제시되었으나 10 mm 밀입도 아스팔트의 경우 최대밀도선과 유사한 입도를 얻게 되어 부드러운 혼합물이 되는 경향을 나타내었다. 국외 입도기준을 참고하여 골재 맞물림과 최소 골재간극률을 확보하기 유리한 입도를 제시하였다. 제시된 입도의 검증을 위해 골재 입도특성지표인 입도비(GR)와 골재다짐밀도(CAD)를 사용하여 혼합물 물성과의 상관관계를 분석하였다. 골재 입도 및 다양한 특성을 반영할 수 있는 CAD 지표의 $R^2$가 0.86~0.99로 매우 높게 나타났다. CAD 지표를 이용하여 다양한 골재 입도를 검토한 결과 제시 입도기준이 마샬안정도와 VMA 등 배합설계 인자에 보다 안정적인 것으로 나타났다. 또한 균열저항성 향상을 위해 0.3 mm 이하 골재의 통과중량백분율을 10% 이상으로 제한함으로서 터프니스가 약 15% 향상되어 효과적임을 확인 할 수 있었다.