• Title/Summary/Keyword: Cr-addition

Search Result 934, Processing Time 0.029 seconds

EFFECTS OF Pt AND Cr ADDITION ON MAGNETIC PROPERTIES IN Co-Cr-P-Pt MAGNETIC THIN FILMS

  • Sohn, H.K.;Shin, K.H.;Lee, T.D.;Kang, T.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.618-622
    • /
    • 1995
  • We studied the effects of Pt and Cr addition in a new Co-Cr-P-Pt alloy system with the coercivity higher than 2000 Oe even when they were deposited without substrate heating and bias voltage. The coercivity of the films increased from 1000 to 2000 Oe or higher by addition of 12 at.%Pt. The variation of the anisotropy field with increasing Pt content was similar to that of the coercivity. This indicate that the increase of the coercivity might be associated with increase of the anisotropy field with Pt addition. With the addition of Cr, the coercivity of the films increased up to 8 at.%Cr and the coercive squareness of the films decreased. The angular variation of coercivity deviated at a lower angle from domain wall motion mode as the Cr content increases. From these result, it is believed that the grain isolation of the films is enhanced with the addition of Cr.

  • PDF

Surface Analysis of Ni-Cr and Co-Cr Alloys with Addition of Ti and Mo for Dental CAD/CAM Use (Ti 및 Mo 첨가에 따른 치과 CAD/CAM용 Ni-Cr 및 Co-Cr합금의 표면분석)

  • Moon, Dae-Sun;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.3
    • /
    • pp.139-148
    • /
    • 2018
  • In this study, surface analysis of Ni-Cr and Co-Cr alloys with addition of Ti and Mo for dental CAD/CAM use has been researched experimentally. The surface characteristics of the alloys were examined by Vickers hardness test, bonding strength test, surface roughness test, field-emission scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction spectroscopy. The shrinkage of the sintered Ni-Cr alloy alloy was slightly larger than that of Ni-Cr-Ti alloy, and larger than Co-Cr alloy. Also, the addition of Mo showed a tendency to decrease shrinkage somewhat. From the result of XRD analysis, NiCr, $Ni_3Cr$ and $Ni_3Ti$ were observed in the sintered Ni-13Cr-xTi and Ni-13Cr-xMo alloys. In addition, ${\sigma}-CrCo$, $Co_2Mo_3$ and $TiCo_2$ were formed in the sintered Co-Cr-xTi and Co-Cr-xMo alloys. Surface hardness of Ti and Mo added alloy was higher than those of Ni-Cr and Co-Cr alloy. The bond strength between sintered alloy and porcelain was $16.1kgf/mm^2$ for Ni-13Cr alloy, $17.8kgf/mm^2$ for Ni-13Cr-5Ti alloy, and $8.2kgf/mm^2$ for Ni-13Cr-10Ti alloy, respectively.

Effects of Alloying Elements on the Pitting Behavior of Ti-Al Intermetallic Compounds (TiAl 금속간화헙물의 공식거동에 미치는 합금원소의 영향)

  • 이호종;최한철
    • Journal of the Korean institute of surface engineering
    • /
    • v.31 no.3
    • /
    • pp.157-164
    • /
    • 1998
  • Effects of alloying elements on the pitting behavior of Ti-Al intermetalic compounds in the electrolytic soution containing Cl- were investigated through electrochemical tets and corrosion morphologies. Corrosion potential increased in the case of Cr addition to Ti-48%Al, whereas it decreased in the case of Si and B addition. The simultaneous addition of Cr and Si increased passive current density and decrosion corrosion potential. The passive current density of N addtion was higher than that of B addition in H2SO4 solution. With the addition of alloying elements, The pitting resistance decreased in order of TiAl>TiAlSi>TiAlN>TiAlB>TiAlCr and whin siumultaneous addition, it decreased in order of TiAlCrSi>TiAlCrBN>TiAlCrrN. The surface merohology after pitting test showed that the TiAl coataining Si had for fewer pits than that containing Cr and N simultaneously.

  • PDF

Effects of Mo and Si on the Coercivity of CoCrTa/CrMo and CoCrTa/CrSi Thin Film Media (CoCrTa/CrX (X=Mo, Si) 자성박막의 보자력에 미치는 Mo와 Si의 영향)

  • 조준식;남인탁;홍양기
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.4
    • /
    • pp.203-209
    • /
    • 1999
  • Effects of Mo and Si addition in Cr underlayer on magnetic properties of CoCrTa/CrMo and CoCrTa/Si thin films media were investigated. Thin films were prepared with DC magnetron sputtering system. The thickness of CoCrTa magnetic layer and Cr underlayer were fixed at 300 $\AA$ and 700 $\AA$, respectively. The substrate heating temperature was kept constant at 26$0^{\circ}C$ for both magnetic layer and underlayer preparation. The coercivity increase of CoCrTa film was realized due to Mo addition in Cr underlayer. Si addition made a small decrease in coercivity. Coercivity increase seems to be attributed by the improvement of preferred orientation of Cr(200) plane. It is found that lattice fit between Cr(200) and CoCrTa(1120) of CrMo underlayer is better than that of CrSi underlayer. This small misfit may also contribute coercivity increase.

  • PDF

Microstructure and Mechanical Properties of Ni-Cr-Mo Based Dental Cast Iron for Porcelain-Fused-to-Metal Firing (도재소부용 Ni-Cr-Mo계 치과용 합금의 미세조직 및 기계적성질)

  • Choi, D.C.
    • Journal of Korea Foundry Society
    • /
    • v.27 no.3
    • /
    • pp.120-125
    • /
    • 2007
  • The microstructure, mechanical properties and melting range of Ni-Cr-Mo based alloys were investigated to develop Be-free Ni-Cr-Mo base dental alloys for Porcelain-Fused-to-Metal Firing(PFM). All as-cast alloys showed dendritic structure. Rockwell hardness of 20Cr7Mo was increased with addition of Si and Ti. On the contrary, it was decreased with addition of Co. The duplex alloying elemental addition such as 3Co + xTi, 2Si + xCo and 2Si + xTi to 20Cr7Mo resulted in much increase of hardness. Rockwell hardness and compressive strength for 20Cr3CoSiTi or 17Cr6CoSiTi alloy that add Si-Ti had similar values compared to the commercial alloys. Melting range for 20Cr3CoSiTi and 17Cr6CoSiTi alloy that add Si-Ti showed similar or lower than commercial alloys. In conclusion, 20Cr3CoSiTi and 17Cr6CoSiTi alloys can be applied for commercial use.

Effect of Ni and Mo Addition on Fatique Property in 12Cr Steel (12Cr강의 피로특성에 미치는 Ni+Mo 첨가의 영향)

  • Lee, Jin-Kyung;Bae, Dong-Su
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.4_2
    • /
    • pp.435-441
    • /
    • 2021
  • This research was performed to study the effect of the Ni + Mo addition on the fatigue properties in 12Cr steel. After heat treatment of 12Cr steel and 12Cr-Ni-Mo steel, tensile tests, impact tests, hardness tests, and rotary bending fatigue tests were performed, respectively. The fatigue fracture surface was observed and analyzed using SEM and EDS. The fatigue limit of 12Cr steel was 554 MPa, which was 49 MPa higher than 505 MPa of 12Cr-Ni-Mo steel. Striations, which are the shape of the typical fatigue fracture surface, were observed at the fracture surface near the starting point of fatigue fracture in the 12Cr steel and 12Cr-Ni-Mo steel. However, unlike the case of 12Cr steel, 12Cr-Ni-Mo steel also had a mixed fracture surface with the fatigue and the ductile fracture surface. When brittle non-metallic inclusions exist near the starting point of fatigue failure, the crack propagation was further promoted and the fatigue life was drastically reduced.

Effects of the Addition of Other Carbides on the Properties of Submicron WC-10% Co Cemented Carbides (초미립 WC-10%Co 초경합금의 물성에 미치는 타탄화물 첨가의 영향)

  • 이승원
    • Journal of Powder Materials
    • /
    • v.3 no.2
    • /
    • pp.86-90
    • /
    • 1996
  • The effects of added VC, Cr$_3$C$_2$ and TaC on the microstructures and properties of submicron WC-10%Co cemented carbides. The relative sintered density of compact was increased by addition of Cr$_3$C$_2$ but decreased oppositely by addition of VC or TaC. The growth of WC grains was significantly suppressed by addition of these carbides. The hardness of these alloys was increased by addition of other carbides and showed a maximum value by simultaneously added VC and Cr$_3$C$_2$. The transverse rupture strength(T.R.S.) was in- creased by addition of Cr$_3$C$_2$, while it was decreased by addition of VC or TaC. The relative sintered density and T.R.S. of these alloys were improved by HIP-treatment. The maximum T.R.S. was 328kg/mm$^2$ in the Wc-10%Co cemented carbide with addition of 0.5%VC.

  • PDF

Effects of ZrC and VC Addition on the Diffusion Induced Recrystallization of TiC--$Cr_3C_2$ (TiC-$Cr_3C_2$ 계 확산구동 재결정에 미치는 ZrC와 VC 첨가영향)

  • 채기웅
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.2
    • /
    • pp.223-227
    • /
    • 1996
  • The effect of ZrC and VC addition on the diffusion induced recrystallization (DIR) of TiC-Cr3C2 has been investigated. With in creasing the amount of added ZrC to Cr3C2 the DIR of TiC was suppressed at the begining and then occurred. On the contrary the DIR was accelerated with the addition of VC to Cr3C2 Because the lattice parameters of (Ti, Cr)C and (Ti,V)C are smaller and that of (Ti, Zr)C is larger than that of TiC the lattice parameter of (Ti,Cr,Zr)C is expected to be similar to that of TiC,. The results indicate that the strain energy due to lattice mismatch between TiC and solid-solution carbide is the driving force of the observed energy due to lattice mismatch between TiC and solid-solution carbide is the driving force of the observed DIR.

  • PDF

Formation of Reactive Oxygen Species and Cr(V) Entities in Chromium(VI) Exposed A549 Cells (크롬 6가 투여 후 A549 세포에서의 Reactive Oxygen Species와 크롬 5가의 발생)

  • 박형숙
    • Environmental Analysis Health and Toxicology
    • /
    • v.11 no.1_2
    • /
    • pp.49-57
    • /
    • 1996
  • The production of reactive oxygen species on addition of hexavalent chromium (potassium dichromate, $K_2Cr_2O_7$ ) to lung cells in culture was studied using flow cytometer analysis. A Coulter Epics Profile flow cytometer was used to detect the formation of reactive oxygen species after $K_2Cr_2O_7$ was added to A549 cells grown to confluence. The cells were loaded with the dye, 2',7'-dichlorofluorescein diacetate, after which cellular esterases removed the acetate groups and the dye was trapped intracellularly. Reactive oxygen species oxidized the dye, with resultant fluorescence. Increased doses of Cr(VI) caused increasing fluorescence (10-fold higher than background at 200 gM). Addition of Cr(III) compounds, as the picolinate or chloride, caused no increased fluorescence. Electron paramagnetic resonance (EPR) spectroscopic studies indicated that three (as yet unidentified) spectral "signals" of the free radical type were formed on addition of 20, 50, 100 and 200 gM Cr(VI) to the A549 cells in suspension. Two other EPR 'signals" with the characteristics of Cr(V) entities were seen at field values lower than the standard free radical value. radical value.

  • PDF

Effect of Mo addition on the Creep Properties of 9Cr-3W Steel (9Cr-3W 강의 크리프 특성에 미치는 Mo 첨가의 영향)

  • Kim, Yong-Rai;Jang, Jinsung;Kim, Tae-Kyu
    • Journal of Korea Foundry Society
    • /
    • v.33 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • The effect of the Mo addition on the high temperature creep properties of the 9Cr-3W steel was also evaluated. Two experimental steels, (9Cr-3W and 9Cr-3W-0.5Mo), were prepared using a vacuum induction melting process, followed by hot rolling and heat treatment processes. Three types of precipitates, ($M_{23}C_6$, Nb-rich MX and V-rich MX) were observed in a typical tempered martensitic matrix. Significant effects of the Mo addition on the tensile properties were not observed. However, the creep properties at $650^{\circ}C$ under applied stresses of 140 and 150 MPa were considerably enhanced by the Mo addition. The microstructural observation after the creep test indicated that the addition of Mo could function to retain the recovery of the martensitic matrix, thus resulting in the enhanced creep properties of the 9Cr-3W-0.5Mo steel. Furthermore coarsening of the $M_{23}C_6$ carbides and formation of Laves phases were observed in both samples after the creep tests.