• 제목/요약/키워드: Cr-Mo-V Steel

검색결과 165건 처리시간 0.041초

고속도강의 미세조직에 미치는 합금원소 및 수직원심주조 조건의 영향 (Influence of Vertical Centrifugal Casting (V.C.C) Conditions and Alloying Elements on Microstructures of High Speed Steel)

  • 김석원;이의종;우기도;김동건
    • 한국주조공학회지
    • /
    • 제20권5호
    • /
    • pp.323-329
    • /
    • 2000
  • The HSS consists of hard carbide and matrix of martensite, and so its characteristics of wear resistance, fracture resistance, and surface roughness are good. This study was undertaken to investigate the influence of Nb and V and manufacturing conditions on microstructural behaviors and characteristics in the HSS cylindrical specimens(90 $mm^{O.D.}$ ${\times}$ 60 $mm^{I.D.}$ ${\times}$ 50 $mm^H$) manufactured using VCC(Vertical Centrifugal Casting). In the specimen of Fe-2C-6Cr-1.5W-3Mo-4V alloy, the amount of MC carbide was increased and $M_7C_3$ carbide was decreased with the increase of V and Nb contents. The primary VC carbide was formed and followed by the rod-type eutectic MC carbide was formed in the cell boundary in 9%V added specimen. MC carbide was increased, and $M_7C_3$ carbide was decreased with the addition of Nb content. In the specimen containing more than 3%Nb, primary NbC carbide was formed within the cell of matrix. With increase in rpm, cell and carbides became fine, and amount of carbide $M_7C_3$ was decreased due to increase in cooling rate.

  • PDF

발전설비 강 용접부의 크리프 특성 평가 기술 개발 (Development of Creep Properties Evaluation Technique for Steel Weldment of Power Plant)

  • 이동환;정영훈;백승세;하정수;송기욱;이송인;유효선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.180-185
    • /
    • 2001
  • In the life assessment for plant structural component, the research on deterioration of toughness and material properties occurred in weldments has been considered as very important problems. In general, the microstructures composed in weldments are hugely classified with weld metal(W.M), fusion line(F.L), heat affected zone(HAZ), and base metal(B.M). It has been reported that the creep characteristics on weldments having variable microstructures could be unpredictably changed. Furthermore, it is also known that HAZ adjacent to F.L exhibits the decreased creep strength compared to those in base or weld metals, and promotes the occurrence of Type III and Type IV cracking due to the growth of grains and the coarsening carbides precipitated in ferritic matrix by welding and PWHT processes. However, the lots of works reported up to date on creep damage in power plant components have been mostly conducted on B.M and the creep properties on a localized microstructures in weldments have not as yet been throughly investigated. In this paper, for various microstructures such as coarse grain HAZ(CGHAZ), W.M and B.M in X20CrMoV121 steel weldment, the small punch-creep(SP-Creep) test using miniaturized specimen(t=0.5mm, 0.25mm) is performed to investigate a possibility for creep characteristics evaluation.

  • PDF

탄소섬유가 혼합된 세라믹 복합재 제동마찰재의 마찰·마모 특성 (Tribological Properties of Ceramic Composite Friction Materials Reinforced by Carbon Fibers)

  • 구병춘;김민수
    • Tribology and Lubricants
    • /
    • 제33권1호
    • /
    • pp.15-22
    • /
    • 2017
  • Because the running speed of vehicles is increasing and a shorter braking distance is required, high heat-resistant brake pads are needed to satisfy the requirements of customers and car makers. In the near future, hazardous materials such as Cu, Cr, Zn, and Sb will be restricted from use in friction materials. Ceramic composites reinforced by carbon fibers are good candidates for eco-friendly friction materials. In this study, we develop ceramic composite friction materials. The friction materials are composed of carbon fibers, Si, SiC, graphite, and phenol resin and are prepared by hot forming and heat treatment at high temperatures. The density, void ratio, and compressive strength are $1.59-1.66g/cm^3$, 16.6-20, and 70-90 MPa, respectively. Friction and wear tests are performed using a pin-on-plate-type reciprocating friction tester at 25, 100, and $200^{\circ}C$. The counterpart material is a CrMoV steel extracted from a KTX brake disc. Friction coefficient, wear amount, and wear mechanism are measured and examined. We determine that the friction coefficients depend on the temperature and the fluctuation of the friction coefficients is larger at higher temperatures. The amount of wear increases with the surface temperatures of the specimens. The tribological properties of the developed composites are similar to those of a Cu-based sintered friction material. Through this study, it is confirmed that ceramic composite materials can be used as friction materials.

금속 임플란트 소재의 내마모성 향상을 위하여 적용되는 질소 이온주입 및 이온도금법의 한계 (Limitation of Nitrogen ion Implantation and Ionplating Techniques Applied for Improvement of Wear Resistance of Metallic Implant Materials)

  • 김철생
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권2호
    • /
    • pp.157-163
    • /
    • 2004
  • 금속 임플란트 재료들의 마모저항을 향상시키기 위하여 질소 이온주입 및 이온도금 기술을 적용하였다. 질소 이온주입 된 초내식성 스테인리스강(S.S.S)의 마모이온용출 특성을 S.S.S, 316L SS, TiN코팅된 316S SS와 비교 평가하기 위하여 탄소로 원자흡수분광분석기를 이용하여 시편들로부터 마모용출된 Cr과 Ni 이온량을 측정하였다. 또한, 저온아크증착법을 이용하여 TiN, ZrN, TiCN코팅된 Ti(Grade 2)원반의 마모저항을 비교하였고, 질소이온주입 및 질화물 코팅된 표면충의 화학적 조성은 SAES(scanning Auger electron spectroscopy)를 이용하여 분석하였다. 질소 이온주입된 S.S.S 표면으로부터 마모에 의하여 용출된 Cr과 Ni 이온량은 표면처리하지 않은 스테인리스강들에 비하여 크게 감소하였다 그러나 인공고관절에 걸리는 하중조건 하에서 실행된 마모이온용출실험에서 이온에너지 100 KeV로 질소이온 주입된 표면층은 20만회 내에서 쉽게 제거되었다. 질화물 코팅된 Ti 시편들의 마모저항도 크게 향상되었고, 그 마모특성은 코팅층의 화학적 조성에 따라 크게 차이가 났다. 코팅두께 3Um의 코팅시편들 중 TiCN 코팅된 티타늄이 가장 높은 내마모 특성을 보였으나 같은 하중조건 하에서 disk(Ti)-on-disk 마모실험에서 그 질화물 코팅면들의 마모 무게감 소비는 1만회 아래에서 모두 Ti의 마모비와 유사하게 전환되었다. 본 실험으로부터 얻어진 연구결과에 의하면, 100 KeV 질소이온주입 및 두께 3$\mu\textrm{m}$의 길화코팅된 표면층의 경우 표면 경화충의 깊이가 충분치 않아 높은 하중을 받는 임플란트의 마찰부위에 사용하기에는 한계가 있음을 보였다.

진단용 다엽콜리메이터 개발을 위한 몬테칼로 시뮬레이션 연구 (Monte Carlo Simulation for Development of Diagnostic Multileaf Collimator)

  • 한수철;박승우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.595-600
    • /
    • 2016
  • 진단방사선 검사 시 환자선량을 감소하기 위한 목적으로 진단용 다엽콜리메이터를 제작하고자 하며, 제작 전 사전연구로서 진단용 다엽콜리메이터에 사용되는 차폐물질 및 차폐효율에 대한 몬테칼로 시뮬레이션을 수행하였다. 몬테칼로 시뮬레이션 코드(MCNPX, LANL, USA)를 이용하여 진단방사선 기기(ReX-650R, Listem, Korea)을 모델링하기 위하여, SRS-78 프로그램을 이용하여 관전압(80, 100, 120 kVp)에 따라 에너지 스펙트럼을 획득하였다. 진단용 다엽콜리메이터의 제작을 위하여 사용된 재료는 SKD-11(탄소 : 1.6%, 규소 : 0.4%, 망간 : 0.6%, 크롬 : 5%, 몰리브덴 : 1%, 바나듐 : 0.3%, 밀도: $7.87g/cm^3$)이며 이를 진단방사선 기기에 진단용 다엽콜리메이터($10{\times}0.5{\times}0.5cm^3$, 좌우 20개씩) 형태로 전산 모사하였다. 진단용 다엽콜리메이터의 차폐효율을 확인하기 위하여 MCNPX 코드의 tally6을 이용하여 에너지별로 차폐효율을 계산하였다. 에너지에 따른 차폐효율은 80 kVp 일 때, 98.3% 차폐되었으며, 100 kVp는 95.7%, 마지막으로 120 kVp는 93.6%가 차폐되는 것을 확인할 수 있었다. 본 연구결과를 기반으로 MLC형태 및, 누설선량에 대한 연구를 진행하여 진단방사선 기기에서 사용 가능한 진단용 다엽콜리메이터 개발에 필요한 정보를 제공할 수 있을 것이라 사료된다.