• Title/Summary/Keyword: Cr-51

Search Result 362, Processing Time 0.022 seconds

Laboratory Tests of Chromium-51 Complexes for teak Detection in Pipes Carrying A Liquid Flow

  • Kim, You-Sun;Lee, Byung-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.231-237
    • /
    • 1974
  • For detection and localization of leaks in closed vessels or pipes carrying liquid flow, $^{51}$ Cr-EDTA and $^{51}$ Cr-DTPA were synthesized and, the column and batch equilibrium experiments were carried out. In the column experiment, the recovery of $^{51}$ Cr-EDTA is 100% in quartz sand and 80.9% in steel sawdust, and that of $^{51}$ Cr-DTPA is 77.4% in quartz sand and 6.4% in steel sawdust. The recovery curve. $^{51}$ Cr-DTPA system in steel sawdust does not show a certain plateau, exceptionally. In general, $^{51}$ Cr-EDTA is adsorbed less than $^{51}$ Cr-DTPA. In the batch equilibrium experiment, the distribution coefficients (Kd) and effect of pH were investigated by using quartz sand, montmorillonite, steel sawdust, and mixed cement raw material as media. In general, the Kd values for $^{51}$ Cr-EDTA are lower than that of $^{51}$ Cr-DTPA. The Kd values for $^{51}$ Cr-EDTA are almost zero at pH 6.0, 7.0, and 8.0.

  • PDF

The Effect of Dietary Pectin on the Upper Gastrointestinal Transit Rate in Rats (흰쥐에 있어서 펙틴이 식이의 상부소화관내 이동 속도에 미치는 영향)

  • Kim, Jung-In
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.21 no.6
    • /
    • pp.627-632
    • /
    • 1992
  • The effect of dietary pectin in the upper gastrointestinal transit rate was studied. Rats fed fiber-free diet or 10% pectin diet were offered 51-$CrCl_3,$ a transit marker. The movement of 51-Cr dose through the gastrointestinal tract was measured at intervals from 20 minutes to 6 hours after dosing. pectin significantly increased gastric emptying rate upto 3 hours after dosing. Pectin also increased small intestinal transit rate from 3 hours to 4 hours after dosing. The results suggest that delayed gastric emptying is not likely the important aspect of the mechanism by which pectin could flatten the post-prandial response of serum glucose and insulin.

  • PDF

Estimation of Glomerular Filtration Rate using Chromium-51 EDTA (Cr-51 EDTA GFR 검사 결과의 분석 및 의의)

  • Lim, Soo-Yeon;Moon, Hyoung-Ho;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.98-103
    • /
    • 2009
  • Purpose: Correct estimation of Glomerular filtration rate (GFR) is very important for an accurate clinical assessment of the kidney function. This study compares four GFR markers, a serum creatinine-based estimation using MDRD formula, Cystatin-C, Cr-51 EDTA 2 samples and 6 samples. Materials and Methods: Serum creatinine concentrations, Cystatin-C serum concentrations and Cr-51 EDTA clearance are measured in 43 patients who received or donated kidney. Results: The correlation coefficient between serum based estimated GFR (MDRD) and Cr-51 EDTA 6 samples was 0.817 (p<0.01). The correlation coefficient between Cystatin-C based GFR and EDTA 6 samples was 0.7322 (p<0.01). Regression analysis showed a statistically significant correlation between Cr-51 EDTA 2 samples and 6 samples (r=0.971, p<0.01). Mean value and ${\pm}2SD$ for the difference between Cr-51 EDTA 2 samples and 6 samples were 4.7 mL/min and ${\pm}9.3$ respectively. Conclusions: The estimation of two samples Cr-51 EDTA showed that the method can be simplified by reducing blood samples without losing its high accuracy.

  • PDF

The Use of Radioactive $^{51}Cr$ in Measurement of Intestinal Blood Loss ($^{51}Cr$을 사용(使用)한 장관내(賜管內) 출혈량측정법(出血量測定法))

  • Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.1
    • /
    • pp.19-26
    • /
    • 1970
  • 1. Sixteen normal healthy subjects free from occult blood in the stool were selected and administered with their $^{51}Cr$ labeled own blood via duodenal tube and the recovery rate of radioactivity in feces and urine was measured. The average fecal recovery rate was 90.7 per cent ($85.7{\sim}97.7%$) of the administered radioactivity, and the average urinary excretion rate was 0.8 per cent ($0.5{\sim}1.5%$) 2. There was a close correlation between the amount of blood administered and the recovery rate from the feces; the more the blood administered, the higher the recovery rate was. It was also found that the administration of the tagged blood in the amount exceeding 15ml was suitable for measuring the radioactivity in the stools. 3. In five normal healthy subjects whose circulating erythrocytes had been tagged with $^{51}Cr$, there was little fecal excretion of radioactivity (average 0.9 ml of blood per day). This excretion is not related to hemorrhage and the main route of excretion of such an negligible radioactivity was postulated as gastric juice and bile. 4. A comparison of the radioactivity in the blood and feces of the patients with $^{51}Cr$ labeled erythrocytes seems to be a valid way of estimating intestinal blood loss.

  • PDF

Synthesis of $[^{51}Cr]Cr(III)$-EDTA Complex and Measurement of Glomerular Filtration Rate br Radioactivity Counting of Head and Neck Region ($[^{51}Cr]Cr(III)$-EDTA 착물 합성 및 $[^{51}Cr]Cr(III)$-EDTA 주사후 두경부 방사능 계측에 의한 사구체 여과율 측정)

  • Yang, Seung-Dae;Lim, Sang-Moo;Chun, Kwon-Soo;Suh, Yong-Sup;Yoon, Yong-Ki;Park, Hyun;Woo, Kwang-Sun;Chung, Wi-Sup;Oh, Ok-Doo;Lee, Jung-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.364-370
    • /
    • 1994
  • The purpose of this study is to evaluate the clinical application of the no carrier added $[^{51}Cr]Cr(III)$-EDTA complexes, produced at Korea Cancer Center Hospital. The $[^{51}Cr]Cr(III)$-EDTA complexes, usefut for measurement of GFR were prepared at room temperature in the presence of bicarbonate catalysts. The radiochemical purity of $[^{51}Cr]Cr(III)$-EDTA was over 99% by paper electrophoresis. The time activity curves were obtained by counting the blood samples from 5 volunteers and counting the head and neck regions with whole body counter after injection of the $^{51}Cr$-EDTA, respectively. After the nonlinear regression, the area under curve was obtained. The plasma clearance of the $^{51}Cr$-EDTA was calculated with injected dose/AUC. The clearance rate calculated with the head and neck counting data was in good agreement with the result from the plasma sample radioactivity at 1-3 hrs after injection. From this result, the counting of head and neck region and the nonlinear regression by 2-compartment model could be applied for the measurement of the clearance rate. Using MIRD system, the absorbed radiation dose was calculated by residence $time{\times}S$. The absorbed whole body radiation dose was negligibly small.

  • PDF

Diffusion of Cr(VI) in Porous Media (심층 지하에서의 육가 크롬 확산)

  • 현재혁
    • The Journal of Engineering Geology
    • /
    • v.3 no.2
    • /
    • pp.203-214
    • /
    • 1993
  • Underground Injection Control regulations for Class I injection wells require that the vertical dufusion be considered as a mechanism for transport of contaninants in evaluating containment Due to the low permeability in the confining aquitard, the movement of contaminants over the long term is controlled by the molecular diffusion. The movement can be predicted, using the Fick' S second law of diffusion. The diffusion coefficient in Fick' s law has been determined experimentally in this study. Instantaneous injection of $^{51}Cr$ was used to trace the distribution of Cr(VI) in soil plugs and an analytical solution was applied to calculate the diffusion coefficients. This study shows the effect of environmental factors, such as temperature, chloride concentration, applied amount of $^{51}Cr$, and bulk density of injection formations on diffusion of Cr(VI)

  • PDF

CYTOTOXICITY OF RETROGRADE FILLING MATERIALS TESTED BY 51Cr RELEASE, MIT AND LD ACTIVITY (51Cr방출과 MTT 및 LD활성도를 이용한 역충전재의 세포독성에 관한 연구)

  • Choi, La-Young;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.409-428
    • /
    • 1994
  • Endodontic surgery is performed when conventional endodontic therapy fails or is contraindicated. In such cases, retrograde filling materials including amalgam, composite resin, and various cements have been used. Biocompatibilty and margin sealing ability of retrograde filling materials are important for the long term success of endodontic surgery. In vitro cell culture is frequently used as the method of measuring the biocompatibilty of dental materials. The purpose of this study was to evaluate the cytotoxicity of six kinds of retrograde filling materials including newly developed light curing glass ionomer cements. Each material was mixed according to. the manufacture's instruction and evaluated as : freshly mixed, 24-hour after mixing, and 168-hour after mixing respectively. The elution solution was extracted after 24-hour contact with materials using media. Cytotoxicity was evaluated by direct contact, or elution contact. Test results of radiochromium($^{51}Cr$) release, cell viability using tetrazolium dye (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl dimethyltetrazolium bromide(MTT) test and lactate dehydrogenase(LD) of damaged L929 cells were analyzed. In the $^{51}Cr$ release of direct contact, all experimental retrograde filling materials except amalgam and glass ionomer cement showed increased cytotoxicity compared to control. In the $^{51}Cr$ release of elution solution, the released $^{51}Cr$ was so minimal that it was impossible. to evlauate the cytotoxicity exactly. The elution solutions of glass ionomer cement and IRM showed marked cytotoxicity in MTT test. LD enzyme activity was highest in tests of direct contact with composite, light curing composite, and light curing glass ionomer cement and IRM. Amalgam revealed least cytotoxicity while IRM showed cytotoxicity using all three methods. Composite, light curing composite and light curing glass iomomer cement were cytotoxic in the tests of $^{51}Cr$ release and LD activity. Glass ionomer cement showed cytotoxic effect only in the MTT method. From these results it is suggested that the standardization and optimization of cytotoxicity testing, especially using elution solutions, should be strongly advised.

  • PDF