• Title/Summary/Keyword: Cr Plating

Search Result 155, Processing Time 0.024 seconds

Chromium and nickel concentrations in air and in serum of workers in chromium and nickel electroplating plants (도금업 근로자의 혈청과 공기중 크롬 및 니켈 농도)

  • Choi, Ho Chun;Kim, Hae Jeong;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.117-127
    • /
    • 1991
  • The exposure level of chromium and nickel for chrome and nickel plating workers were evaluated. Chromium and nickel concentrations in serum from 82 exposed workers and 66 controls, who were not exposed occupationally to metals, were analyzed by flameless atomic absorption spectrophotometry. The results were as follows : 1. The recovery percent of chromium and nickel concentrations in personal air samples were 95-108.2%, 88.0-107.7%, precisions (C.V., %) were 2.7-3.1%, 2.1-4.4%. respectively. 2. The recovery percent of chromium and nickel concentrations in serum were 93.6-106.4%, 91.3-107.9% and precisions (C.V. %) were 1.1-7.6%, 2.4-5.4% respectively. 3. The exposure level of chromium and nickel concentrations in the place of preparation process were $2.0{\pm}2.00{\mu}g/m^3$, chromplating were $35.7{\pm}53.07{\mu}g/m^3$, $2.8{\pm}3.42{\mu}g/m^3$, nickelplating were $4.6.0{\pm}5.8{\mu}g/m^3$, $18.62{\pm}4.41{\mu}g/m^3$, and covering were $2.9{\pm}2.02{\mu}g/m^3$, $1.1{\pm}0.47{\mu}g/m^3$ respectively. There were significant difference of concentrations for chromium and nickel in workplaces by groups statistically. 4. Chromium concentrations in serum of exposed group and control were $0.68{\pm}0.399{\mu}g/l$, $1.41{\pm}0.748{\mu}g/l$, respectively. There were significant difference of concentrations for chromium and nickel in serum by groups statistically. 5. Chromium and nickel concentrations in serum of exposed group were not significant by workplaces.

  • PDF

Surface Properties of Chromium Nitrided Carbon Steel as Separator for PEMFC (크롬질화처리한 저탄소강의 고분자 전해질 연료전지 분리판으로서의 표면특성)

  • Choi, Chang-Yong;Kang, Nam-Hyun;Nam, Dae-Geun
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.5
    • /
    • pp.173-178
    • /
    • 2011
  • Separator of stack in polymer electrolyte membrane fuel cell (PEMFC) is high cost and heavy. If we make it low cost and lighter, it will have a great ripple. In this study, low carbon steel is used as base metal of separator because the cost of low carbon steel is very cheaper commercial metal material than stainless steels, which is widely used as separator. Low carbon steel has not a good corrosion resistance. In order to improve the corrosion resistance and electrolytic conductivity, low carbon steel needs to be surface treated. We made Chromium electroplated layer of $5{\mu}m$, $10{\mu}m$ thickness on the surface of low carbon steel and it was nitrided for 2 hours at $1000^{\circ}C$ in a furnace with 100 torr nitrogen gas pressure. Cross-sectional and surface microstructures of surface treated low carbon steel are investigated using SEM. And crystal structures are investigated by XRD. Interfacial contact resistance and corrosion tests were considered to simulate the internal operating conditions of PEMFC stack. The corrosion test was performed in 0.1 N $H_2SO_4$ + 2 ppm $F^-$ solution at $80^{\circ}C$. Throughout this research, we try to know that low carbon steel can be replaced stainless steel in separator of PEMFC.

The Application of Plasma Nitrocarburizing and Plasma Post Oxidation Technology to the Automobile Engine Parts Shafts (자동차 엔진부품용 Shaft에 플라즈마 산질화기술 적용)

  • Jeon, Eun-Kab;Park, Ik-Min;Lee, In-Sup
    • Korean Journal of Materials Research
    • /
    • v.16 no.11
    • /
    • pp.681-686
    • /
    • 2006
  • Plasma nitrocarburising and plasma post oxidation were performed to improve the wear and corrosion resistance of S45C and SCM440 steel by a plasma ion nitriding system. Plasma nitrocarburizing was conducted for 3h at $570^{\circ}C$ in the nitrogen, hydrogen and methane atmosphere to produce the ${\varepsilon}-Fe_{2-3}$(N, C) phase. Plasma post oxidation was performed on the nitrocarburized samples with various oxygen/hydrogen ratio at constant temperature of $500^{\circ}C$ for 1 hour. The very thin magnetite ($Fe_3O_4$) layer $1-2{\mu}m$ in thickness on top of the $15{\sim}25{\mu}m$ ${\varepsilon}-Fe_{2-3}$(N, C) compound layer was obtained by plasma post oxidation. A salt spray test and electrochemical testing revealed that in the tested 5% NaCl solution, the corrosion characteristics of the nitrocarburized compound layer could be further improved by the application of the superficial magnetite layer. Throttle valve shafts were treated under optimum plasma processing conditions. Accelerated life time test results, using throttle body assembled with shaft treated by plasma nitrocarburising and post oxidation, showed that plasma nitrocarburizing and plasma post oxidation processes could be a viable technology in the very near future which can replace $Cr^{6+}$ plating.

Exposed level of workers in the factory next to a lead recycling factory (연 재생공장 인접 근로자들의 연 폭로정도에 관한 조사)

  • Kim, Jin-Ha;Lee, Duk-Hee;Lee, Yong-Hwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.693-700
    • /
    • 1996
  • The purpose of this study was to determine whether workers at a factory next to a lead recycling factory in Pusan, were affected by lead contamination. The mean air lead concentration of lead recycling factory was $0.21mg/m^3(TWA=0.05mg/m^3)$. Thirty-nine male workers of Factory A, Cr. plating factory next to the lead recycling factory were exposed group and a comparison group, 62 male workers of Factory B were selected from another Cr. plating factory about 8.5km away from lead recycling factory. Air lead concentration of each workplace was checked for 4 times from August f to August 20 in 1995 by low volume air sampler. Each subject was interviewed about age, life-style, smoking, work history, and residence etc, and venous blood was drawn for lead measurement by graphite furnace atomic absorption spectrometry. We have observed that air lead concentration and blood lead concentration of Factory A was higher than Factory $B(2.6{\pm}1.6\;Vs.\;1.2{\pm}0.2{\mu}g/m^3,\;14.9{\pm}1.6\;Vs.\;12.2{\pm}1.6{\mu}g/dl)$. We believe that other environmental lead sources such as transportation and residence did not affect air lead and blood lead concentration differences of both factory. We concluded that high air lead and blood lead concentration of Factory A were caused by lead contamination generated by the neighboring lead recycling factory.

  • PDF

Limitation of Nitrogen ion Implantation and Ionplating Techniques Applied for Improvement of Wear Resistance of Metallic Implant Materials (금속 임플란트 소재의 내마모성 향상을 위하여 적용되는 질소 이온주입 및 이온도금법의 한계)

  • 김철생
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.157-163
    • /
    • 2004
  • Nitrogen ion implantation and ion plating techniques were applied for improvement of the wear resistance of metallic implant materials. In this work, the wear dissolution behaviour of a nitrogen ion implanted super stainless steel (S.S.S, 22Cr-20Ni-6Mo-0.25N) was compared with those of S.S.S, 316L SS and TiN coated 316L SS. The amounts of Cr and Ni ions worn-out from the specimens were Investigated using an electrothermal atomic absorption spectrometry. Furthermore, the Ti(Grade 2) disks were coated with TiN, ZrN and TiCN by use of low temperature arc vapor deposition and the wear resistance of the coating layers was compared with that of titanium. The chemical compositions of the nitrogen ion implanted and nitride coated layers were examined with a scanting auger electron spectroscopy. It wat observed that the metal ions released from the nitrogen ion implanted S.S.S surface were significantly reduced. From the results obtained, it was shown that the nitrogen ion implanted zone obtained with 100 KeV ion energy was easily removed within 200,000 revolutions from a wear dissolution testing under a similar load condition when applied to artificial hip joint. The remarkable improvement in wear resistance weir confirmed by the nitrides coated Ti materials and the wear properties differ greatly according to the chemical composition of the coating layers. for specimens with the same coating thickness of about 3$\mu\textrm{m}$, TiCN coated Ti showed the highest wear resistance. However, after removing the coating layers, the wear rates of all nitrides coated Ti reverted to their normal rates of below 10,000 revolutions from Ti-disk-on-disk wear testing under the same load condition. From the results obtained, it is suggested that the insufficient depth of the 100 Kel N$\^$+/ ion implanted zone and of the nitrides coated layers of 3$\mu\textrm{m}$ are subject to restriction when used as frictional parts of load bearing implants.