• Title/Summary/Keyword: Cr(VI)-containing wastewater

Search Result 8, Processing Time 0.032 seconds

The Characteristics of Adsorption Treatment of Cr(VI)-containing Wastewater using Kudzu as the Adsorbent (칡을 이용(利用)한 크롬페수(廢水) 흡착(吸着) 처리(處理) 특성(特性))

  • Seo, Myung-Soon;Kim, Dong-Su
    • Resources Recycling
    • /
    • v.17 no.3
    • /
    • pp.56-61
    • /
    • 2008
  • The kudzu has been investigated as an adsorbent for treatment of Cr(VI)-containing wastewater. The specific surface of kudzu was analyzed to be $189.91m^2/g$ and its major composition were found to be nitrogen and oxygen. It was observed that adsorption reaction for Cr(VI) on kudzu meets 1st order in kinetics and Langmuir Model in equilibrium. As the pH of wastewater was increased, the adsorbed amount of Cr(VI) onto kudzu was increased due to the pre-combination of $OH^-$ with adsorbent and the efficiency of adsorption was found to be 60% when real electroplating Cr(VI)-containing wastewater was applied.

Studies on Atomic Absorption Spectrophotometric Analysis of Hexavalent Chromium in Waste Water by Solvent Extraction (용매 추출법에 의한 폐수중 6가크롬의 원자흡수 분광분석에 관한 연구)

  • Eung-Pyo Kim;Young-Sang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.423-432
    • /
    • 1986
  • Atomic absorption spectrophotometric (AAS) determination of hexavalent chromium [Cr(VI)] in a waste water was studied. Cr(VI) was extracted with p-xylene from the wastewater, in the way of ion pair formation with anion exchanger aliquat-336(tri-caprylmethyl ammonium chloride). 100ml waste water, after organic materials were extracted out with toluene, was acidified with conc. HCl adjusting the medium to pH 0.5 and 20ml of p-xylene containing 0.01M aliguat-336 was used to extract Cr(VI) from the acidified solution. The absorbance of chromium was measured with air-acetylene flame at 357.9nm. Standard addition method was used in the determining concentration of Cr(VI) extracted. No interference has been found in the extraction of Cr(VI) by the Al(III), Fe(III) and Cr(III) ion presented. However, Fe(II) decreased the absorbance of Cr(VI), due to the fact Fe(II) reduces Cr(VI) to Cr(III). The contained organic material was removed prior to extracting process, since it may reduced the absorbance of Cr(VI). The recovery of added Cr(VI) was over 96%, which seems to be promising and the relative standard deviation was 3.95%

  • PDF

Removal of Hexavalent Chromium by using Biomass (바이오매스를 이용한 6가 크롬의 제거)

  • Park, Donghee;Park, Jong Moon
    • Korean Chemical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.107-113
    • /
    • 2006
  • Not only Cr(VI) is very toxic, but also it is a major pollutant in soil and groundwater. Thus Cr(VI)-containing wastewater must be treated before being discharged into the environments. Recently, biosorption technology using abundant biomass has been considered as an innovative one for removing Cr(VI) from aqueous solution. In this review article, current research and future works on Cr(VI) biosorption were widely described. Particularly, the removal mechanism of Cr(VI) by biomass was described in detail, which has been misunderstood by many researchers until now.

Effects of Ionic Strength, Background Electrolytes, Heavy Metals, and Redox-Active Species on the Reduction of Hexavalent Chromium by Ecklonia Biomass

  • PARK DONGHEE;YUN YEOUNG-SANG;JO JI HYE;PARK JONG MOON
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.4
    • /
    • pp.780-786
    • /
    • 2005
  • The biomass of the brown seaweed, Ecklonia, was used to remove Cr(VI) from wastewater. Previously, Cr(VI) was removed through its reduction to Cr(III) when brought into contact with the biomass. In this study, the effects of ionic strength, background electrolytes, and Cr(III), Ni(II), Zn(II), and Fe(III) on the Cr(VI) reduction were examined. An increased ionic strength inhibited the Cr(VI) reduction. The presence of other heavy metals, such as Cr(III), Ni(II), or Zn(II), only slightly affected the Cr(VI) reduction, while Fe(III) enhanced the reduction. Although the above various parameters could affect the reduction rate of Cr(VI) by Ecklonia biomass, these effects were relatively smaller than those of pH and temperature. In addition, the previously derived rate equation was found to be applicable over a range of ionic strengths and with different background electrolytes. In conclusion, Ecklonia, bioniass may be a good candidate as a biosorbent for the removal of Cr(VI) from wastewaters containing various other impurities, and scale-up to a practical process may be accomplished using the previously derived rate equation.

Simultaneous Removal of Phenol and Hexavalent Chromium by Rhodococcus sp. CP01 (Rhodococcus sp. CP01에 의한 페놀과 6가 크롬이온의 동시 제거)

  • 최광현;오영숙;김병동;최성찬
    • Korean Journal of Microbiology
    • /
    • v.36 no.4
    • /
    • pp.279-284
    • /
    • 2000
  • Simultaneous reduction of Cr(VI) and degradation of phenol was observed in batch and bench-scale continuous stirred tank reactors using Rhodococcus sp. CP01 isolated from leachate. The strain CP01, which was capable of utilizing phenol as a sole source of carbon and energy, completely reduced added hexavalent chromium (0.25 mM) to its trivalent form during 60 hr batch assay under optimal conditions (pH 7.0 and 1,000 mg/L of phenol concentration). The rates of Cr(VI) reduction and phenol degradation were estimated as 4.17 $\mu$M Cr(VI) and 38.4 mg phenol.$L^{-1}{\cdot}hr^{-1}$, respectively. The continuous culture experiment was conducted for 46 days using synthetic feed containing different levels of chromate (0.0625 to 0.25 mM) and phenol(1,000 to 4,000 mg/L). With a hydraulic retention time of 100 hr, Cr(VI) reduction efficiency was mostly 100% for influent Cr(VI) and phenol concentrations of 0.125 mM and 3,000 mg/L, respectively. During quasi-steady-state operation, specific rate of Cr(VI) reduction was calculated as 0.34 mg Cr(VI).g $protein^{-1}{\cdot}hr^{-1}$ which was comparable to reported values obtained by using glucose as growth substrate. The results suggest the potential application of biological treatment for detoxification of wastewater contaminated simultaneously with Cr(VI) and pheonol.

  • PDF

Mechanism of Removal of Cr(VI) Ions from Solution by Borosilicate Glasses Containing Alkaline Earth Oxides (알칼리토 금속산화물이 함유된 붕규산염계 유리를 이용한 용액 중 Cr6+ 이온 제거 기구)

  • Back, Il-Hee;Lim, Hyung-Bong;Kim, Cheol-Young
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.3
    • /
    • pp.222-227
    • /
    • 2011
  • The hexavalent chromium ions in wastewater are highly toxic chemicals even at low concentrations. It causes serious diseases, such as cancer, skin disease, digestive trouble et. al. In this study, $Cr^{6+}$ ions were removed by using borosilicate glasses. Various glasses system with different compositions were prepared and then reacted in a solution contaning $Cr^{6+}$ ions. After the reaction, the concentration of the $Cr^{6+}$ ions remained in the solution was measured by ICP-OES. The reacted surface of the glasses was also analyzed by using a XRD, SEM, and EDS. When $Na_2O-RO-SiO_2-B_2O_3$ (RO=MgO, CaO, SrO, BaO) glasses were reacted with a solution containing $Cr^{6+}$ ions, the optimum removal efficiency of $Cr^{6+}$ ions was observed in the BaO glass. $Ba^{2+}$ ions leached out of these glasses combine with $Cr^{6+}$ ions in a solution to form $BaCrO_4$ crystals on the glass surface. In this manner, the $Cr^{6+}$ ions can be removed from the solution. It is conceivable that $Ba^{2+}$ ions are reacted with $Cr^{6+}$ ions in a solution immedeately after leaching out of the glasses. The pH of the solution for optimum removal of $Cr^{6+}$ ions were 3.0~5.0.

Reduction of Hexavalent Chromium by Leachate Microorganisms in a Continuous Suspended Growth Culture (연속배양 체제에서의 침출수 미생물에 의한 6가 크롬이온의 환원)

  • Kim, Hyoun-Young;Oh, Young-Sook;Kim, Yeong-Kwan;Choi, Sung-Chan
    • Korean Journal of Microbiology
    • /
    • v.34 no.3
    • /
    • pp.126-131
    • /
    • 1998
  • Reduction of hexavalent chromium to its trivalent form by leachate microorganisms was studied in batch and bench-scale continuous stirred tank reactor. The inoculum was a culture of microorganisms in leachate and capable of providing up to 90% chromate reduction during 72 h batch assay with $20mg\;Cr(VI)\;L^{-1}$ in minimal media containing different levels of leachate (10 to 60%) and glucose (50 to 200 mM). Addition of glucose increased the efficiency of chromate reduction, but adverse effect was observed with increase of leachate probably due to the competitive inhibition between chromate and sulfate ions. The continuous culture experiment was conducted for 124 days using synthetic feed containing different levels of chromate (5 to $65mg\;L^{-1}$) at room temperature. With a hydraulic retention time of 36 h, chromate reduction efficiency was mostly 100% when Cr(VI) concentrations in the reactor were in the range of 5 to $50mg\;L^{-1}$ Specific rate of Cr(VI) removal was calculated as $3.492mg\;g^{-1}\;protein\;h^{-1}$ during the period of 101~124 days from the start-up which showed 81.2% of average reduction efficiency. The results indicate the potential application of using leachate microorganisms for detoxification of hexavalent chromium in various chromium-contaminated wastewater from landfill or tannery sites.

  • PDF

A Study on the Applicaton of Electrical Resistivity Survey in the Contaminated Soil and Groundwater Site (토양 및 지하수 오염지역에 대한 전기비저항탐사의 적용성 연구)

  • Chae, Seungheon;Lee, Sangeun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.525-539
    • /
    • 2020
  • A site containing buried solid waste and treated water and oil storage containers from a leather manufacturing plant was studied through soil and groundwater pollution and electrical resistivity surveys with the aim of identifying areas polluted by leachate generated by landfilling with leather waste and leakage wastewater. It was found that TPH and Zn exceeded environmental standards for soil pollution and, for leachate and groundwater, Cr(VI) concentrations exceeded standard levels for groundwater quality. An electrical resistivity survey was used to elucidate soil and groundwater pollution characteristics and diffusion pathways. Ten survey lines were set up with an electrode spacing of 5 m in a dipole-dipole array. The hydraulic characteristics of soil determined by groundwater contamination surveys matched well the low-resistivity-anomaly zones. Electrical resistivity surveys of areas containing contaminated soil and groundwater that have irregular strata due to waste reclamation are thus useful in highlighting vertical and horizontal pollutant diffusion pathways and in monitoring contaminated and potentially contaminated areas.