• Title/Summary/Keyword: Coverage index

Search Result 288, Processing Time 0.032 seconds

Dosimetric Analysis of Lung Stereotactic Body Radiotherapy Using Halcyon Linear Accelerator

  • Shinhaeng Cho;Ick Joon Cho;Yong Hyub Kim;Jea-Uk Jeong;Mee Sun Yoon;Taek-Keun Nam;Sung-Ja Ahn;Ju-Young Song
    • Progress in Medical Physics
    • /
    • v.34 no.4
    • /
    • pp.48-54
    • /
    • 2023
  • Purpose: In this study, the dosimetric characteristics of lung stereotactic body radiotherapy (SBRT) plans using the new Halcyon system were analyzed to assess its suitability. Methods: We compared the key dosimetric parameters calculated for the Halcyon SBRT plans with those of a conventional C-arm linear accelerator (LINAC) equipped with a high-definition multileaf collimator (HD-MLC)-Trilogy Tx. A total of 10 patients with non-small-cell lung cancer were selected, and all SBRT plans were generated using the RapidArc technique. Results: Trilogy Tx exhibited significant superiority over Halcyon in terms of target dose coverage (conformity index, homogeneity index, D0.1 cc, and D95%) and dose spillage (gradient). Trilogy Tx was more efficient than Halcyon in the lung SBRT beam delivery process in terms of the total number of monitor units, modulation factor, and beam-on time. However, it was feasible to achieve a dose distribution that met SBRT plan requirements using Halcyon, with no significant differences in satisfying organs at risk dose constraints between both plans. Conclusions: Results confirm that Halcyon is a viable alternative for performing lung SBRT in the absence of a LINAC equipped with HD-MLC. However, extra consideration should be taken in determining whether to use Halcyon when the planning target volume setting is enormous, as in the case of significant tumor motions.

Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon (직장풍선을 삽입한 전립선암 환자의 수술 후 방사선 치료 시 용적변조와 세기변조방사선치료계획 비교 평가)

  • Jung, hae youn;Seok, jin yong;Hong, joo wan;Chang, nam jun;Choi, byeong don;Park, jin hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Purpose : The dose distribution of organ at risk (OAR) and normal tissue is affected by treatment technique in postoperative radiation therapy for prostate cancer. The aim of this study was to compare dose distribution characteristic and to evaluate treatment efficiency by devising VMAT plans according to applying differed number of arc and IMRT plan for postoperative patient of prostate cancer radiation therapy using a rectal balloon. Materials and Methods : Ten patients who received postoperative prostate radiation therapy in our hospital were compared. CT images of patients who inserted rectal balloon were acquired with 3 mm thickness and 10 MV energy of HD120MLC equipped Truebeam STx (Varian, Palo Alto, USA) was applied by using Eclipse (Version 11.0, Varian, Palo Alto, USA). 1 Arc, 2 Arc VMAT plans and 7-field IMRT plan were devised for each patient and same values were applied for dose volume constraint and plan normalization. To evaluate these plans, PTV coverage, conformity index (CI) and homogeneity index (HI) were compared and $R_{50%}$ was calculated to assess low dose spillage as per treatment plan. $D_{25%}$ of rectum and bladder Dmean were compared on OAR. And to evaluate the treatment efficiency, total monitor units(MU) and delivery time were considered. Each assessed result was analyzed by average value of 10 patients. Additionally, portal dosimetry was carried out for accuracy verification of beam delivery. Results : There was no significant difference on PTV coverage and HI among 3 plans. Especially CI and $R_{50%}$ on 7F-IMRT were the highest as 1.230, 3.991 respectively(p=0.00). Rectum $D_{25%}$ was similar between 1A-VMAT and 2A-VMAT. But approximately 7% higher value was observed on 7F-IMRT compare to the others(p=0.02) and bladder Dmean were similar among the all plan(P>0.05). Total MU were 494.7, 479.7, 757.9 respectively(P=0.00) for 1A-VMAT, 2A-VMAT, 7F-IMRT and at the most on 7F-IMRT. The delivery time were 65.2sec, 133.1sec, 145.5sec respectively(p=0.00). The obvious shortest time was observed on 1A-VMAT. All plans indicated over 99.5%(p=0.00) of gamma pass rate (2 mm, 2%) in portal dosimetry quality assurance. Conclusion : As a result of study, postoperative prostate cancer radiation therapy for patient using a rectal balloon, there was no significant difference of PTV coverage but 1A-VMAT and 2A-VMAT were more efficient for dose reduction of normal tissue and OARs. Between VMAT plans. $R_{50%}$ and MU were little lower in 2A-VMAT but 1A-VMAT has the shortest delivery time. So it is regarded to be an effective plan and it can reduce intra-fractional motion of patient also.

  • PDF

A Study on Ecological Evaluation of Habitat Suitability Index using GIS - With a case study of Prionailurus bengalensis in Samjang-Sanchung Road Construction - (GIS를 이용한 서식지적합성지수(HSI)의 생태영향평가 활용방안연구 - 삼장-산청 국도건설공사를 사례에서 삵을 중심으로 -)

  • Lee, Sang-Don;Kwon, Ji-Hye;Kim, Ah-Ram;Jung, Ji-Hyang
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.801-811
    • /
    • 2012
  • For biodiversity conservation, Biological Impact Assessment is very important. The focus of the study is to enhance efficient Environment Impact Assessment(EIA) based on collecting existing information of endangered species covering the status survey, estimation of effects and reducing methods. Habitat Suitability Index(HSI) can be applicable to Ecological Impact Assessment and finding various reducing methods based on estimating effects. For this study, the EIA report of Samjang - Sanchung highway construction was chosen as an example and Prionailurus bengalensis euptilura as an endangered species was chosen to assess the ecosystem impact on road construction. Water, road, ground coverage, slope, altitude as variables of habitat were weighted and final HSI map was calculated using Arc map and Arc view. Through comparing of before and after HSI, quantitative estimating on effects was possible to minimize impact of road construction to wildlife habitat.

Seasonal Variability of Marine Algal Flora and Community Structure at Gumgap, Jindo, on the Southwestern Coast of Korea (한국 남서해안 진도군 금갑의 해조상 및 군집구조의 계절 변화)

  • Yoo, Hyun-Il;Heo, Jin-Suk;Choi, Han-Gil
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.1
    • /
    • pp.300-307
    • /
    • 2015
  • Seasonal variation in marine macroalgal community structure was examined at the intertidal zones of Geumgap, Jindo, Korea, from October 2013 to August 2014. In total, 56 macroalgal species were identified, including 9 green, 12 brown, and 35 red algae. Annual seaweed biomass was 548.96 g wet wt. /$m^2$ with seasonal range between 371.08 g wet wt. /$m^2$ at summer and 32.91 g wet wt. /$m^2$ at winter. The dominant seaweed in terms of biomass was Sargassum thunbergii and subdominant species were Gelidium elegans, Sargassum fusiforme, and Ishige okamurae. The vertical distribution of seaweeds from the upper to lower intertidal zones was Gloiopeltis spp., Ulva spp.- S. thunbergii, S. fusiforme, Ishige okamurae - S. thunbergii, S. fusiforme, G. elegans. Annual seaweed coverage, richness index (R), evenness index (J'), and diversity index (H') values were 27.95%, 6.10, 0.38, and 1.38, respectively. Coarsely branched form was the most dominant functional group in terms of species number and biomass among benthic macroalgal species.

Selection of radiation treatment plan technique at breast cancer operating technique (유방암 수술기법에 따른 방사선치료계획 기법의 선택)

  • Kim, Jeong-Ho;Bae, Seok-Hwan;Kim, Ki-Jin;Yoo, Se-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.125-130
    • /
    • 2015
  • Techniques, using physical wedge filter and using dynamic wedge filter and FIF(Field in Field) and ISCT(Irregular Surface Compensating Technique), have been developed according to progress of radiation therapy of breast cancer. Measurement of dose was done to judge the usefulness of technique using three cases, non tissue loss after breast conserving operating and tissue loss after breast conserving operating and mastectomy. Dose indexes of breast tissue, CI (Conformity Index), HI (Homogeneity Index) and QOC (Quality of Coverage), dose index of skin, or dose indexes of lung, volume of 50 percent dose and 20 percent dose were estimated and compared. Using dynamic wedge filter is useful plan at non tissue loss allowing for high dose of lung. FIF and ISCT are useful plan at tissue loss. ISCT is useful plan at mastectomy. Henceforth, we need to apply to valid plan and body type and thorax size.

Studies on the Properties of the Plasma TEOS $SiO_2$ Film (PECVD TEOS $SiO_2$막의 특성에 관한 연구)

  • 이수천;이종무
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.2
    • /
    • pp.206-212
    • /
    • 1994
  • Effects of the film deposition process parameters on the properties such as deposition rate, etch rate, refractive index, stress and step coverage of plasma enhanced chemical vapor deposited (PECVD) tetraethylorthosilicate glass (TEOS) SiO2 film were investigated and analysed using SEM, FTIR and SIMS techniques. Increasing TEOS flow or decreasing O2 flow increased the deposition rate and the compressive stress of the oxide film but produced a less denser film. The deposition rate decreased owing to the decrease in the sticking coefficient of the TEOS and the O2 molecules onto the substrate Si with increasing the substrate temperature. Increasing the substrate temperature produced a denser film with a lower etch rate and the higher refractive index by lowering SiOH and moisture contents. Increasing the rf power increases the ion bombardment energy. This increase in energy, in turn, increases the deposition rate and tends to make the film denser. No appreciable changes were found in the deposition rate but the refractive index and the stress of the film decreased with increasing the deposition pressure. The carbon content in the plasma TEOS CVD oxide film prepared under our standard deposition conditions were very low according to the SIMS analysis results.

  • PDF

Comparison of plan dosimetry on multi-targeted lung radiotherapy: A phantom-based computational study using IMRT and VMAT

  • Khan, Muhammad Isa;Rehman, Jalil ur;Afzal, Muhammad;Chow, James C.L.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3816-3823
    • /
    • 2022
  • This work analyzed the dosimetric difference between the intensity modulated radiotherapy (IMRT), partial/single/double-arc volumetric modulated arc therapy (PA/SA/DA-VMAT) techniques in treatment planning for treating more than one target of lung cancer at different isocenters. IMRT and VMAT plans at different isocenters were created systematically using a Harold heterogeneous lung phantom. The conformity index (CI), homogeneity index (HI), gradient index (GI), dose-volume histogram and mean and maximum dose of the PTV were calculated and analyzed. Furthermore, the dose-volume histogram and mean and maximum doses of the OARs such as right lung, contralateral lung and non GTV were determined from the plans. The IMRT plans showed the superior target dose coverage, higher mean and maximum values than other VMAT techniques. PA-VMAT technique shows more lung sparing and DA-VMAT increases the V5/10/20 values of contralateral lung than other VMAT and IMRT techniques. The IMRT technique achieves highly conformal dose distribution to the target than other VMAT techniques. Comparing to the IMRT plans, the higher V5/10/20 and mean lung dose were observed in the contralateral lung in the DA-VMAT.

Dielectric and Passivation-Related Properties of Pecvd PSG (PECVD PSG의 유전 및 보호막특성에 관한 연구)

  • 유현규;강영일
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.2
    • /
    • pp.90-96
    • /
    • 1985
  • The properties of plasma-enhanced CVD phosphorous silicate glass (PECVD PSG) for passivation layer are studied . Phosphorous contentration was analyzed with X-ray fluores-cence. As a result, PECVD PSG has a limiting phosphors concentration of about 8 mole%. Curves relating to etcll rate, infrared absorption ratio, and sheet resistivity were adapted to monitor phosphorous concentration indirectly Dielectric properties, step coverage, crack resistance, and gettering effect are discussed in both of atmospheric pressure CVD (APCVO) and PECVD oxide. PECVD SiO2 film have density of about 2.4 g/㎤ at deposition rate of 450$\AA$/min, refractive index of about 1.53, and breakdown at fields of II-13 MV/cm. Crack resistance of PECVD oxide is greater than APCVD oxide. PECVD PSG films contained with 2 mole % phosphorous show good step coverage and gettering ability. The obtained results show more advantages in PECVD PSG than in APCVD PSG for device passivation.

  • PDF

Differences in Artificial Nest Boxes Use of Tits Between Deciduous and Coniferous Forests

  • Rhim, Shin-Jae;Lee, Ju-Young
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.5 s.162
    • /
    • pp.338-341
    • /
    • 2005
  • This study was conducted to describe the differences in artificial nest boxes use of tits between deciduous and coniferous forests at 2nd campus of Chung-Ang University ($37^{\circ}00^{\prime}04^{{\prime}{\prime}}N$, $127^{\circ}13^{\prime}96^{{\prime}{\prime}}E$), Ansung, Korea from January to August 2005. Tree species richness, tree species diversity index (H') and total basal areas were higher in deciduous forest than in coniferous forest. High, middle, low and understory canopy layers were more developed in deciduous forest, except the coverage of bush-ground layer. Varied tit Parus varius, marsh tit P. palustris and great tit P. major used the artificial nest boxes in this study. Number of breeding pairs of tits used artificial nest boxes, clutch size, and weight and size of eggs were higher in deciduous forest than in coniferous forest. The differences in habitat structure between study sites are very likely to have influenced how breeding birds used the available habitat. Artificial nest boxes could be used as management and conservation tool for birds, particularly in areas, where the availability of natural cavities and coverage of higher layer are limited.

Reconstruction of Multiple Digital Defects by Temporary Syndactylization Using a Lateral Arm Free Flap

  • Sae Hwi Ki;Jin Myung Yoon;Tae Jun Park;M. Seung Suk Choi;Min Ki Hong
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.745-749
    • /
    • 2022
  • Background Soft tissue defects of the multiple finger present challenges to reconstruction surgeons. Here, we introduce the use of a lateral arm free flap and syndactylization for the coverage of multiple finger soft tissue defects. Methods This retrospective study was conducted based on reviews of the medical records of 13 patients with multiple soft tissue defects of fingers (n = 33) that underwent temporary syndactylization with a microvascular lateral arm flap for temporary syndactylization from January 2010 to December 2020. Surgical and functional outcomes, times of flap division, complications, and demographic data were analyzed. Results Middle fingers were most frequently affected, followed by ring and index fingers. Mean patient age was 43.58 years. The 13 patients had suffered 10 traumas, 2 thermal burns, and 1 scar contracture. Release of temporary syndactyly was performed 3 to 9 weeks after syndactylization. All flaps survived, but partial necrosis occurred in one patient, who required a local transposition flap after syndactylization release. The mean follow-up was 15.8 months. Conclusion Coverage of multiple finger defects by temporary syndactylization using a free lateral arm flap with subsequent division offers an alternative treatment option.