• 제목/요약/키워드: Cover-plate

검색결과 190건 처리시간 0.022초

연속형 센서와 웨이브 전파를 이용한 판 구조물의 손상감지 (Damage Detection of Plate Using Long Continuous Sensor and Wave Propagation)

  • 이종원
    • 한국소음진동공학회논문집
    • /
    • 제20권3호
    • /
    • pp.272-278
    • /
    • 2010
  • A method for damage detection in a plate structure is presented based on strain waves that are generated by impact or damage in the structure. Strain responses from continuous sensors, which are long ribbon-like sensors made from piezoceramic fibers or other materials, were used with a neural network technique to estimate the damage location. The continuous sensor uses only a small number of channels of data acquisition and can cover large areas of the structure. A grid type structural neural system composed of the continuous sensors was developed for effective damage localization in a plate structure. The ratios of maximum strains and arrival times of the maximum strains obtained from the continuous sensors were used as input data to a neural network. Simulated damage localizations on a plate were carried out and the identified damage locations agreed reasonably well with the exact damage locations.

강판으로 보강된 원형철근콘크리트교각의 내진성능 평가에 관한 해석적 연구 (Numerical Study on Seismic Performance Evaluation of Circular Reinforced Concrete Piers Confined by Steel Plate)

  • 이명진;박종섭
    • 한국산학기술학회논문지
    • /
    • 제22권1호
    • /
    • pp.116-122
    • /
    • 2021
  • 본 논문은 반복하중을 받는 원형 철근콘크리트 교각 외부에 강판 보강을 적용한 경우, 교각의 성능 향상도를 정량적으로 평가하였다. 범용 유한 요소해석프로그램인 ABAQUS의 다양한 3차원 요소를 적용하여 교각 구조물을 해석하였다. 비탄성, 비선형 해석 변수로는 강판 보강 높이와 교각 높이 비, 강판 보강 두께와 교각 지름 비를 적용하였다. 교각 하부는 고정단으로 고려하였으며, 하중은 교각 상단에 횡 방향 반복하중을 가력하였다. 하중-변위 곡선, 응력-변형률 곡선, 연성도, 에너지 흡수 능력을 고려하여 보강에 따른 교각의 내진 성능 향상도를 평가하였다. 강판으로 보강한 원형철근콘크리트 교각은 보강재로 인한 외부 콘크리트 구속 효과로 인해 기둥의 항복 하중과 극한하중이 평균 3.76배 증가하였고, 에너지 흡수능력은 최대 4배 증가하였다. 소성 힌지가 발생하는 교각 하부 부분만 보강하여도 연성도가 크게 향상되었으며 강판의 두께가 두꺼울수록 에너지 흡수 능력이 가장 큰 값을 나타내었다. 본 연구결과를 토대로 원형철근콘크리트 교각의 외부 강판 보강을 통하여 교각의 구조 성능을 향상시킬 수 있음을 정량적으로 확인할 수 있었다.

마이크로 정량펌프의 유동해석과 작동성능 평가 (The Flow Analysis and Evaluation of the Peristaltic Micropump)

  • 박대섭;최종필;김병희;장인배;김헌영
    • 한국정밀공학회지
    • /
    • 제21권2호
    • /
    • pp.195-202
    • /
    • 2004
  • This paper presents the fabrication and evaluation of mechanical behavior for a peristaltic micropump by flow simulation. The valve-less micropump using the diffuser/nozzle is consists of the lower plate, the middle plate, the upper plate and the tube that connects inlet and outlet of the pump. The lower plate includes the channel and the chamber, and the plain middle plate are made of glass and actuated by the piezoelectric translator. Channels and a chamber on the lower plate are fabricated on high processability silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The upper plate does the roll of a pump cover and has inlet/outlet/electric holes. Three plates are laminated by the aligner and bonded by the anodic bonding process. Flow simulation is performed using error-reduced finite volume method (FVM). As results of the flow simulation and experiments, the single chamber pump has severe flow problems, such as a backflow and large fluctuation of a flow rate. It is proved that the double-chamber micropump proposed in this paper can reduce the drawback of the single-chamber one.

과대 볼트구멍에 따른 고장력볼트 마찰이음의 사용성에 관한 연구 (A Study on the Serviceability of High-Tension Bolt Friction Joints according to Oversize Bolt Holes)

  • 박정웅;양승현;조강균
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.2055-2061
    • /
    • 2009
  • 고장력볼트 마찰이음에서 모재 및 덮개판을 과대공 제작하였을 경우 연결부의 내하력에 다소의 변화가 발생 될 수 있다. 본 논문에서는 고장력볼트 마찰이음에서 표준공과 과대공에 따라 미끄럼하중과 미끄럼계수의 변화를 파악하기 위하여 정적인장시험을 실시하였다. 정적인장시험결과 모재 및 덮개판의 과대공 제작에 따라 미끄럼계수의 변화가 다소 발생하였으나 이를 정형화시키기에는 다소 무리가 따랐으며, 미끄럼강도는 표준공 제작시의 값과 과대공제작시의 값이 최대 26%의 차이를 나타내었다. 그러나 이는 설계미끄럼강도를 초과하기 때문에 사용하중하에서 연결부의 사용성에 미치는 영향이 미약하므로 강부재 제작시 부득이하게 발생할 수 있는 과대공에 따른 규정을 보다 유연하게 적용시킨다면 구조물의 설계 및 시공시 효율성과 경제성 증대의 효과가 기대된다고 판단되었다.

와이어로프 기반 비부착 보강된 RC 기둥의 내진거동에 대한 T형 강판 정착의 영향 (Influence of Anchorage of T-Plate on the Seismic Performance of RC Columns Strengthened with Unbounded Wire Rope Units)

  • 심재일;양근혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.133-140
    • /
    • 2010
  • 와이어로프와 T형 강판을 이용한 비부착공법의 내진성능을 평가하기 위해 중심 축하중과 반복 횡하중을 받는 5개의 보강된 기둥과 무보강 기둥을 실험하였다. 주요 변수는 T형 강판의 정착방법과 피복 모르터의 유 무이다. 실험결과 T형 강판이 정착된 기둥의 하중분배로 인한 휨 내력 및 연성 증가를 확인할 수 있었다. 그러나 T형 강판이 정착되지 않은 기둥은 연성 증가에는 효과적이지만 T형 강판으로 하중이 분배되지 않았다. 피복 모르터가 있는 보강된 기둥은 효과적인 초기 강성 및 휨 내력 증가를 보였지만 연성증가에는 불리하였다. 단면분할법을 이용해 예측한 보강된 기둥의 최대 휨 내력은 등가응력블럭을 사용하여 예측한 ACI 318-05 기준보다 실험결과를 예측하였다.

Behavior and design of stainless steel tubular member welded end connections

  • Kiymaz, Guven;Seckin, Edip
    • Steel and Composite Structures
    • /
    • 제17권3호
    • /
    • pp.253-269
    • /
    • 2014
  • Among the various alternatives to make a steel tubular member connection, making a slotted and gusset plate welded connection is one of the most frequently preferred alternatives. This type of connection is essentially an end connection that is made by slotting the tube longitudinally, inserting the gusset plate and then placing longitudinal fillet welds at the tube-to-plate interface. In this paper an experimental study on the behaviour of such connections in stainless steel is presented. 24 specimens were tested under concentrically applied axial tensile forces for varying tube-to-gusset plate weld lengths. Both circular and box section members were considered in the test program. Load-deformation curves were obtained and comparisons were made in terms of strength and ductility. The results obtained from the study were then critically examined and compared with currently available design guidance for slotted gusset plate welded tubular end connections. It is noted that no specific rules exist in international specifications on structural stainless steel which cover the design of such connections. Therefore, the results of this study are compared with the existing design rules for carbon steel.

마그네슘합금 판재 정밀성형을 위한 판단조 공정 연구 (Plate Forging Process for Near-net Shaping of Mg-alloy Sheet)

  • 송용현;김세종;이영선;윤은유
    • 소성∙가공
    • /
    • 제30권1호
    • /
    • pp.35-42
    • /
    • 2021
  • Magnesium alloys are used in electronic devices such as laptops due to their lightweight features as well as vibration absorption and electromagnetic shielding properties. However, the precision of electronics is limited by the large number of small and precise ribs, the cost-effective manufacture of which requires appropriate technology. Plate forging is an efficient manufacturing process that can address these challenges. In this study, plate forging of magnesium alloys was investigated specifically for the fabrication of laptop cover. The plate forging process with back-pressure was used for near-net shape formation. Finite element analysis was used to select appropriate variables for back-pressure formation to generate ribs of various sizes and shapes without defects. The reliability of the analysis was verified to manufacture the prototype. The effect of back-pressure can be verified via fabrication of prototypes as well as structure and forming analysis based on finite element method. The process design factor of back-pressure increases formability without defects of under-filling and flow-through. Moreover, the tensile strength was maintained even after high temperature plate forging at 370 ℃, and the elongation was improved.

BAF에서 분위기 가스와 대류판 형태가 열전달 특성에 미치는 영향 (Effects of the Convector Plate Shape and the Atmospheric Gas on Characteristics of Heat Transfer in a Batch Annealing Furnace)

  • 윤순현;김문경;김대성
    • 한국정밀공학회지
    • /
    • 제13권8호
    • /
    • pp.72-79
    • /
    • 1996
  • In a BAF(Batch Annealing Furnace), various studies have been pursued in order to reduce energy consumption rate to improve productivity and to stabilize the properties of products. The purpose of this study was to investigate the effects of both the atmospheric gas and convector plate shapes on the augmentation of heat transfer. The use of hydrogen instead of nitrogen as an atmospheric gas, combined with high convection in the BAF, has shown that considerable increases in furnace out put and significantly improved material quality are attainable. Because convector plate shapes make the atmosheric gas easily flow density, high diffusivity and reducing character of hydrogen, a better heat transfer rates resulting in uniform material temperature distribution and improved coil surface quality can be achieved. Also, it was found that the closed convector plate took more time for the annealing cycle time than the other plate type(open-type)by about ten hours.

  • PDF

휨을 받는 고장력볼트 체결부에서 과대공에 따른 사용성에 관한 연구 (A Study on Serviceability of Oversized Bolt Hole in High-Tension Bolt Joint Subjected to Bending)

  • 박정웅;양승현;장석인
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2831-2836
    • /
    • 2009
  • 고장력볼트를 이용한 강부재의 연결부에서 마찰력을 초과하는 설계하중이 작용하여 미끄럼이 발생하는 점을 기점으로 볼트와 모재의 전단강도 및 지압강도에 의해 설계하중을 지지하게 된다. 미끄럼량은 볼트의 장력, 접촉면의 마찰계수, 모재구멍내에서 볼트의 위치에 따라 결정되어 질 수 있다. 본 연구에서는 모재 및 덮개판에 대하여 볼트구멍의 크기를 변화시켜 제작된 고장력볼트 체결부에 순수굽힘과 인장력이 작용하는 경우 표준공과 과대공에 따른 미끄럼을 측정하고 비교분석하였다. 표준공을 가지는 경우보다 과대공을 가지는 경우에 $74\sim94%$ 작은 하중에서 미끄럼이 발생하였다. 인장력을 받는 부재에서는 과대공치수가 클수록 미끄럼 하중비가 작게 나타났으며 모재의 과대공치수가 덮개판의 과대공치수보다 미끄럼하중변화와 연관성이 많은 것으로 나타났다.

강구조물(鋼構造物)의 용접연결부(鎔接連結部)의 피로강도(疲勞强度)에 관한 연구(研究)(I) (A Study on the Fatigue Strength of the Welded Joints in Steel Structures(I))

  • 박제선;장동일;정영화
    • 대한토목학회논문집
    • /
    • 제5권3호
    • /
    • pp.161-175
    • /
    • 1985
  • 판항교(鈑桁橋)의 덮개 판(板), 수직보강재(垂直補强材) 및 연결판(連結板) 등의 용접연결부(鎔接連結部)를 포함하는 실물(實物)을 modeling 하여 직접(直接) 피로시험(疲勞試驗)을 행하지 않고서도 계산 program에 의해 S-N 선도(線圖)를 그리는 방안을 정립하여 서울의 수동대교(水東大橋), 제(第) 3 한강교(漢江橋) 및 춘천(春川)의 강촌교(江村橋) 등에 적용해 보았다. 이에 앞서, SS 41, SS 50, SWS 50, SWS 58 등의 구조강(構造鋼)으로서 소재(素材), 균열방향에 평행용정, 균열방향에 직각 용접의 compact tension 시험편을 제작 피로시험을 행하여 계산 program 중의 data로 쓰여질 재료상수(材料常數) c 및 m 값을 구하였다. 이 결과 다음과 같은 결과들을 얻었다. 덮개판(板)의 경우 다른 두 부분보다 피로강도(疲勞强度)가 매우 낮았다. 덮개판(板)의 경우 두께가 커지면 피로강도(疲勞强度)가 상당히 낮아지는 외에는 치수에 그다지 큰 영향을 받지 않으며, c 및 m 값에는 매우 민감한 영향을 받음을 알 수 있었다. c 값 및 m 값이 적어질수록 피로강도(疲勞强度)가 상당히 커지며, m 값이 적어지면 S-N 곡신의 경사가 매우 급해짐을 알 수 있었다. 이와 같은 연구가 계속되어 더 많은 data가 집적(集積)되면 앞으로 설계(設計)될 판항교(鈑桁橋)의 피로설계지침(疲勞設計指針)을 마련하고, 또 기존(旣存) 판항교(鈑桁橋)의 피로(疲勞)에 대한 내용년한(耐用年限)을 추정(推定)할 수 있는 기본(基本) pattern이 제공(提供)할 수 있으리라 사료된다.

  • PDF