• Title/Summary/Keyword: Coupling mechanism

Search Result 331, Processing Time 0.031 seconds

Shear mechanism of steel fiber reinforced concrete deep coupling beams

  • Li, Kou;Zhao, Jun;Ren, Wenbo
    • Structural Engineering and Mechanics
    • /
    • v.73 no.2
    • /
    • pp.143-152
    • /
    • 2020
  • Deep coupling beams are more prone to suffer brittle shear failure. The addition of steel fibers to seismic members such as coupling beams can improve their shear performance and ductility. Based on the test results of steel fiber reinforced concrete(SFRC) coupling beams with span-to-depth ratio between 1.5 and 2.5 under lateral reverse cyclic load, the shear mechanism were analyzed by using strut-and-tie model theory, and the effects of the span-to-depth ratio, compressive strength and volume fraction of steel fiber on shear strengths were also discussed. A simplified calculation method to predict the shear capacity of SFRC deep coupling beams was proposed. The results show that the shear force is mainly transmitted by a strut-and-tie mechanism composed of three types of inclined concrete struts, vertical reinforcement ties and nodes. The influence of span-to-depth ratio on shear capacity is mainly due to the change of inclination angle of main inclined struts. The increasing of concrete compressive strength or volume fraction of steel fiber can improve the shear capacity of SFRC deep coupling beams mainly by enhancing the bearing capacity of compressive struts or tensile strength of the vertical tie. The proposed calculation method is verified using experimental data, and comparative results show that the prediction values agree well with the test ones.

Coupling mechanism of a loop-type ground radiation antenna

  • Zahid, Zeeshan;Kim, Hyeongdong
    • ETRI Journal
    • /
    • v.41 no.4
    • /
    • pp.528-535
    • /
    • 2019
  • The coupling mechanism of a loop-type ground radiation antenna is investigated in this paper. We use the equivalent circuit model of the antenna and a full-wave simulation to explain the coupling mechanism of the antenna. We analyze the effects of various antenna parameters on the coupling between the antenna element and the ground plane to examine the conditions for enhancing the coupling. Based on simulations with the equivalent circuit model, full-wave simulations, and measurements, we propose optimal design considerations for the antenna. The findings of this study will aid the design and understanding of loop-type ground radiation antennas for mobile devices.

Mechanism Analysis and Stabilization of Three-Phase Grid-Inverter Systems Considering Frequency Coupling

  • Wang, Guoning;Du, Xiong;Shi, Ying;Tai, Heng-Ming;Ji, Yongliang
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.853-862
    • /
    • 2018
  • Frequency coupling in the phase domain is a recently reported phenomenon for phase locked loop (PLL) based three-phase grid-inverter systems. This paper investigates the mechanism and stabilization method for the frequency coupling to the stability of grid-inverter systems. Self and accompanying admittance models are employed to represent the frequency coupling characteristics of the inverter, and a small signal equivalent circuit of a grid-inverter system is set up to reveal the mechanism of the frequency coupling to the system stability. The analysis reveals that the equivalent inverter admittance is changed due to the frequency coupling of the inverter, and the system stability is affected. In the end, retuning the bandwidth of the phase locked loop is presented to stabilize the three-phase grid-inverter system. Experimental results are given to verify the analysis and the stabilization scheme.

The mechanism of rockburst-outburst coupling disaster considering the coal-rock combination: An experiment study

  • Du, Feng;Wang, Kai;Guo, Yangyang;Wang, Gongda;Wang, Liang;Wang, Yanhai
    • Geomechanics and Engineering
    • /
    • v.22 no.3
    • /
    • pp.255-264
    • /
    • 2020
  • With the ongoing development of deep mining of coal resources, some coal mine dynamic disasters have exhibited characteristics of both coal-gas outbursts and rockbursts. Therefore, research is required on the mechanism of rockburst-outburst coupling disaster. In this study, the failure characteristics of coal-rock combination structures were investigated using lab-scale physical simulation experiments. The energy criterion of the rockburst-outburst coupling disaster was obtained, and the mechanism of the disaster induced by the gas-solid coupling instability of the coal-rock combination structure was determined. The experimental results indicate that the damage of the coal-rock structure is significantly different from that of a coal body. The influence of the coal-rock structure should be considered in the study of rockburst-outburst coupling disaster. The deformation degree of the roof is controlled by the more significant main role of the gas pressure and the difference in the strength between the rock body and the coal body. The outburst holes and spall characteristics of the coal body after the failure of the coal-rock structure are strongly affected by the difference in strength between the roof and the coal body. The research results provide an in-depth understanding of the mechanism of rockburst-outburst coupling disasters in deep mining.

Failure analysis of prestressed concrete containment vessels under internal pressure considering thermomechanical coupling

  • Yu-Xiao Wu;Zi-Jian Fei;De-Cheng Feng;Meng-Yan Song
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4504-4517
    • /
    • 2023
  • After a loss of coolant accident (LOCA) in the prestressed concrete containment vessels (PCCVs) of nuclear power plants, the coupling of temperature and pressure can significantly affect the mechanical properties of the PCCVs. However, there is no consensus on how this coupling affects the failure mechanism of PCCVs. In this paper, a simplified finite element modeling method is proposed to study the effect of temperature and pressure coupling on PCCVs. The experiment results of a 1:4 scale PCCV model tested at Sandia National Laboratory (SNL) are compared with the results obtained from the proposed modeling approach. Seven working conditions are set up by varying the internal and external temperatures to investigate the failure mechanism of the PCCV model under the coupling effect of temperature and pressure. The results of this paper demonstrate that the finite element model established by the simplified finite element method proposed in this paper is highly consistent with the experimental results. Furthermore, the stress-displacement curve of the PCCV during loading can be divided into four stages, each of which corresponds to the damage to the concrete, steel liner, steel rebar, and prestressing tendon. Finally, the failure mechanism of the PCCV is significantly affected by temperature.

Mechanistic Study of Half-titanocene-based Reductive Pinacol Coupling Reaction

  • Kim, Young-Jo;Do, Young-Kyu;Park, Sung-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.11
    • /
    • pp.3973-3978
    • /
    • 2011
  • The reductive pinacol coupling reaction of aldehydes or ketones creating a new C-C bond has been a major tool to produce 1,2-diol compounds. The reaction mechanism is known to be composed of sequential three steps (activation, coupling, and dissociation). In this work, we studied the dissociation step of half-titanocene-based catalytic systems. Cp and $Cp^*$ derivatives of the pinacolato-bridged dinuclear complex were synthesized and evaluated as possible models for intermediates from the coupling step. We monitored $^1H$-NMR spectra of the reaction between the metalla-pinacol intermediates and $D_2O$. New reaction routes of the dissociation step including oxo- and pinacolato-dibridged dinuclear complexes and oxo-bridged multinuclear complexes have been suggested.

Equivalent Admittance of a Slit Fed by a Flanged Parallel-Plate Waveguide and Maximum Coupling Mechanism through a Narrow Slit (플랜지된 평행평판도파관으로 급전된 슬릿의 등가 어드미턴스 및 좁은 슬릿을 통한 최대결합 메커니즘)

  • 이종익;김강욱;조영기
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.11
    • /
    • pp.1116-1122
    • /
    • 2004
  • The problem of electromagnetic coupling through a slit in a flanged parallel-plate waveguide is considered. The equivalent slit admittance associated with reactive powers near the coupling slit inside and outside the waveguide has been obtained. The maximum coupling mechanism for the case of narrow slit has been quantitatively discussed. The effects of various geometrical parameters such as guide height, slit width, and slit of offset on the radiation characteristics of the geometry have been investigated.

Dual Stage Servo Controller for Image Tracking System (듀얼 스테이지 서보 시스템을 이용한 영상 추적장치의 정밀제어)

  • Choi, Young-Joon;Kang, Min-Sig
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.2 s.191
    • /
    • pp.86-94
    • /
    • 2007
  • In this paper, a dual stage servo mechanism has been developed for image tracking system to improve control performances such as small rise time, small overshoot, small settling time, small stabilization error etc. A secondary stage, a platform, actuated by a pair of electro-magnets is mounted on a conventional elevation gimbal. In this mechanism, the gimbal provides large range but slow motion and the platform provides small range but fast positioning. A sliding mode control is applied to the platform positioning to attain robust performances and stability in the presence of the disturbance related to dynamic coupling of the gimbal and the platform. Results from experiments illustrate that the suggested dual stage mechanism controlled by the sliding mode control is effective in improving responses and attenuating the disturbance response related with dynamic coupling.

Structural Aspects of GPCR-G Protein Coupling

  • Chung, Ka Young
    • Toxicological Research
    • /
    • v.29 no.3
    • /
    • pp.149-155
    • /
    • 2013
  • G protein-coupled receptors (GPCRs) are membrane receptors; approximately 40% of drugs on the market target GPCRs. A precise understanding of the activation mechanism of GPCRs would facilitate the development of more effective and less toxic drugs. Heterotrimeric G proteins are important molecular switches in GPCR-mediated signal transduction. An agonist-activated receptor interacts with specific sites on G proteins and promotes the release of GDP from the $G{\alpha}$ subunit. Because of the important biological role of the GPCR-G protein coupling, conformational changes in the G protein upon receptor coupling have been of great interest. One of the most important questions was the interface between the GPCR and G proteins and the structural mechanism of GPCR-induced G protein activation. A number of biochemical and biophysical studies have been performed since the late 80s to address these questions; there was a significant breakthrough in 2011 when the crystal structure of a GPCR-G protein complex was solved. This review discusses the structural aspects of GPCR-G protein coupling by comparing the results of previous biochemical and biophysical studies to the GPCR-G protein crystal structure.