• Title/Summary/Keyword: Coupling loss

Search Result 591, Processing Time 0.031 seconds

6.78MHz Capacitive Coupling Wireless Power Transfer System

  • Yi, Kang Hyun
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.987-993
    • /
    • 2015
  • Wireless power transfer technologies typically include inductive coupling, magnetic resonance, and capacitive coupling methods. Among these methods, capacitive coupling wireless power transfer (CCWPT) has been studied to overcome the drawbacks of other approaches. CCWPT has many advantages such as having a simple structure, low standing power loss, reduced electromagnetic interference (EMI) and the ability to transfer power through metal barriers. In this paper, the CCWPT system with 6.78MHz class D inverter is proposed and analyzed. The proposed system consists of a 6.78MHz class D inverter with a LC low pass filter, capacitor between a transmitter and a receiver, and impedance transformers. The system is verified with a prototype for charging mobile devices.

Coupling loss variation as the shape of fiber ends and the fiber arrangement in a fiber Fabry-Perot filter (광섬유 Fabry-Perot필터에서 광섬유 단면의 모양과 배치에 따른 결합손실 변화)

  • 김종호;예윤해
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.230-235
    • /
    • 1997
  • Coupling loss variation as the shape of fiber ends and the fiber arrangement in a fiber Fabry-Perot cavity, formed with two optical fibers with dielectric mirror coatings on their ends, is analyzed. For the intended features it is assumed that one of two fibers is processed to have a concave mirror whose curvature is the same as that of the wavefront of the Gaussian beam from the first fiber. In this assumption, it was turned out that the coupling loss at the cavity length of 15 ${\mu}{\textrm}{m}$ is less than 0.5% even with tilt angle of 0.2$^{\circ}$, curvature error of 70 ${\mu}{\textrm}{m}$, cavity length error of 8 ${\mu}{\textrm}{m}$, and lateral alignment error of 0.5 ${\mu}{\textrm}{m}$. Thus, low loss and high-finesse fiber Fabry-Perot filters whose cavity length is greater than several ${\mu}{\textrm}{m}$ can be obtained easily if the receiving fiber end is properly formed.

  • PDF

High performance couplers using micromachined transmission lines in millimeter-wave band (마이크로 머시닝 기술을 이용한 밀리미터파 대역 저 손실 결합기에 관한 연구)

  • Lim, Byeong-Ok;Kim, Sung-Chan;Baek, Tae-Jong;Shin, Dong-Hoon;Rhee, Jin-Koo
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.925-928
    • /
    • 2005
  • In this study, we fabricated the DAMLs using surface micromachining technology as well a low loss coupler for the millimeter-wave band applications using these DAMLs. The structure of DAML is that a signal line is supported on ground plane by dielectric posts. Therefore it has advantages about the loss characteristic and the stable structure. The other advantage of the DAML process is a simple and convenient technique using 4 mask steps, even if it has a micromachining technology. The lowest loss of the fabricated DAML was obtained 2.2 dB/cm at 110 GHz. To obtain the low loss characteristic, couplers were designed and fabricated by using DAMLs. The fabricated ring hybrid coupler has the coupling of 3.58 dB and the thru of 3.31 dB at 60 GHz. We can also obtain the coupling of 3.42 dB, the thru of 3.82 dB from fabricated branch line coupler at 60 GHz.

  • PDF

Design of a Broadband Single Balanced Diode Mixer Using a Vortical Coupling Structure (Vertical Coupling 구조를 이용한 광대역 단일 평형 다이오드 혼합기의 설계)

  • Lee Myeong-Gil;Yun Tae-Soon;Nam Hee;Lee Jong-Chul
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.4 no.3 s.8
    • /
    • pp.45-50
    • /
    • 2005
  • In this paper, a broadband single balanced mixer is presented using a wideband rat-race implementation by vertical coupling. Frequency is selected as $1.5{\sim}3$ GHz for RF, $1.64{\sim}3.14$ GHz for LO, and 140 MHz for IF signals. When LO signal with 6 dBm at 2.7 GHz is injected, a conversion loss of 7.5 dB and RF to LO isolation of 30 dB are obtained. Also, an average conversion loss of 10 dB, RF to LO isolation of 30 dB, and LO to IF isolation of 45 dB are obtained for frequency band of $1.5{\sim}3$ GHz.

  • PDF

An Experimental Study on Steel Plate Coupling Beam (철골 플레이트 커플링 보의 실험적 연구)

  • Hong, Sung-Gul;Lim, Woo-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.301-304
    • /
    • 2008
  • This paper presented an structural efficiency of steel coupling beam jointed single plate shear connections with seat and top angle. Parameters for the test specimens were are seat and top angle, reinforcing of concrete, embedded length, section loss. Steel coupling beam with angle showed excellent strength, stiffness, energy dissipation capacity. The specimen with no reinforcement around the embedded steel plate showed slightly low deformation capacity because of early failure in the precast concrete walls. However, the specimen with reinforcement around the embedded steel plate showed good deformation capacity. Deformation capacity was not decrease despite short embedded length. The specimen with section loss showed excellent deformation capacity. Because shear strength of steel coupling beam was lesser than of connections. These results showed that for workability and cost efficiency, the proposed system is promising for one of steel coupling beam.

  • PDF

Miniaturized Narrow Band-pass Filter with λg/4 Short Stubs Using S-Shaped Folded Coupling Structure (크기가 축소된 S 형태의 Folded 커플링 구조를 이용한 λg/4 단락형 협대역 스터브 대역통과 여파기)

  • Yoon, Ki-cheol;Kim, Seong-cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.10
    • /
    • pp.2269-2274
    • /
    • 2015
  • In this paper, the reduced size in horizontal sizes of the narrow band pass filter (BPF) with λg/4 short stub using S shaped folded coupling structure is presented. This BPF with narrow bandwidth show flexible bandwidth with variation of the position of the stubs using the Qe(external quality factor) without changing the impedance value. On the other hand, by replacing the horizontal quarter-wavelength transmission lines with the equivalent S shaped coupled line, the BPF with reduced the size of horizontal can be realized. The proposed BPF shows the insertion loss of 1.46 dB and the return loss of 16.5 dB with bandwidth of 3.4 % at the center frequency of 5.8 GHz, respectively.

Design of a Rod-Type Aspheric Lens Collimator for Optical Telecommunication (막대 형태의 비구면 렌즈를 이용한 광통신용 시준기의 설계)

  • Kang, Seok-Bong;Kang, Eun-Kyoung;HwangBo, Chang-Kwon;Kang, Sang-Do;Kim, Jong-Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.31-35
    • /
    • 2008
  • A rod-type aspheric lens collimator for the optical telecommunication system which shows high coupling efficiency and experiences small coupling loss for misalignment errors is designed. The working distance, thickness, and diameter of the rod-type aspheric lens are determined to be close to those of the GRIN lens collimator in order to replace the GRIN lens with the rod-type aspheric lens. Since the coupling loss mainly originated from the spherical aberration of the lens, the spherical aberration in the rod-type aspheric lens is reduced drastically, and it turns out that the coupling efficiency of the rod-type aspheric lens collimator is higher than that of the available collimators, such as ball lens, GRIN lens, and C-type lens collimators.

Study on vibration energy characteristics of vehicle-track-viaduct coupling system considering partial contact loss beneath track slab

  • Liu, Linya;Zuo, Zhiyuan;Zhou, Qinyue;Qin, Jialiang;Liu, Quanmin
    • Structural Engineering and Mechanics
    • /
    • v.75 no.4
    • /
    • pp.497-506
    • /
    • 2020
  • CA mortar layer disengagement will give rise to the overall structural changes of the track and variation in the vibration form of the ballastless track. By establishing a vehicle-track-viaduct coupling analysis and calculation model, it is possible to analyze the CRTS-I type track structure vibration response while the track slab is disengaging with the power flow evaluation method, to compare the two disengaging types, namely partial contact loss at one edge beneath track slab and partial contact loss at midpoint beneath track slab. It can also study how the length of disengaging influences the track structures vibration power. It is showed that when the partial contact loss beneath track slab, and the relative vibration energy level between the rail and the track slab increases significantly within [10, 200]Hz with the same disengaging length, the partial contact loss at one edge beneath track slab has more prominent influence on the vibration power than the partial contact loss at midpoint beneath track slab. With the increase of disengaging length, the relative vibration energy level of the track slab grows sharply, but it will change significantly when it reaches 1.56 m. Little effect will be caused by the relative vibration energy level of the viaduct. The partial contact loss beneath the track slab will cause more power distribution and transmission between the trail and track slab, and will then affect the service life of the rail and track slab.

Performance of Direct-Conversion Receiver with AC-Coupling in DC-Offset interference environment (DC-Offset 간섭환경에서 AC-Coupling을 갖는 직접변환 수신기의 성능)

  • 성봉훈;송윤정;김영완;김내수;서종수
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.9-14
    • /
    • 2002
  • Direct-conversion receiver(DCR) architecture has superior advantages in size, cost, and power over superheterodyne receiver architectures. However, the use of direct-conversion receiver architecture has been limited due to the direct-current offset noise. The ac coupling, which is used to overcome the direct-current offset noise, causes an inter-symbol interference(ISI), whose effects can be effectively mitigated using an equalizer. In this paper, the performance of a direct-conversion receiver with ac coupling in the presence of direct-current offset is analyzed via computer simulation. The simulation result shows that by using decision feedback equalizer with LMS(Least Mean Square) algorithm, signal-to-noise ratio loss of the direct-conversion receiver compared to the idea receiver can be reduced to less than 1㏈ for corner frequencies as large as 10% of the symbol rate.

  • PDF

A Study on Electrical Properties and Structure Analysis of Epoxy-Ceramic Composite Materials (에폭시-세라믹 복합재료의 전기적 특성 및 구조분석)

  • 정지원;홍경진;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.9-12
    • /
    • 1994
  • Epoxy-Ceramic Composite have good insulating, therma1 and mechanical properties, so it is studied actively on this material. In this thesis, we made a composite material b)\ulcorner filling Epoxy Resin with ceramics treated with Sillane Coupling Agent and studied dielectric and insulating characteristics according to treatment density of Sillane Coupling Agent and weight percent of filler. As a result, loss tangent increase and electrical breakdown voltage decrease according to increasing treatment density of sillane coupling agent because Interface matching between matrix and filler is not good. The best treatment density of sillane coupling agent is 0.5% water solution, in this density the best interface matching is achieved so good dielectric and insulation characteristics are shown. Dielectric and insulation characteristics according to weight percent of filler are best at 25wt.

  • PDF