• 제목/요약/키워드: Coupling coefficient

검색결과 529건 처리시간 0.021초

A study on the working mechanism of internal pressure of super-large cooling towers based on two-way coupling between wind and rain

  • Ke, Shitang;Yu, Wenlin;Ge, Yaojun
    • Structural Engineering and Mechanics
    • /
    • 제70권4호
    • /
    • pp.479-497
    • /
    • 2019
  • In the current code design, the use of a uniform internal pressure coefficient of cooling towers as internal suction cannot reflect the 3D characteristics of flow field inside the tower body with different ventilation rate of shutters. Moreover, extreme weather such as heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind. In this study, the world's tallest cooling tower under construction, which stands 210m, is taken as the research object. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed iteratively using continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind speed and rainfall intensity on the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower body is analyzed. The combination of wind velocity and rainfall intensity that is most unfavorable to the cooling tower in terms of distribution of internal pressure coefficient is identified. On this basis, the wind/rain loads, distribution of aerodynamic force and working mechanism of internal pressures of the cooling tower under the most unfavorable working condition are compared between the four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the amount of raindrops captured by the internal surface of the tower decreases as the wind velocity increases, and increases along with the rainfall intensity and ventilation rate of the shutters. The maximum value of rain-induced pressure coefficient is 0.013. The research findings lay the basis for determining the precise values of internal surface loads of cooling tower under extreme weather conditions.

콘크리트 슬래브궤도에서 레일과 철근 사이의 결합계수에 대한 연구 (A Study on Coupling Coefficient Between Rail and Reinforcing Bars in Concrete Slab Track)

  • 김민석;이상혁;이종우
    • 한국철도학회논문집
    • /
    • 제12권3호
    • /
    • pp.405-411
    • /
    • 2009
  • 고속철도 신호시스템은 ATC시스템을 이용하여 열차의 제한속도를 송신하고, 일부 도시철도 신호시스템은 이동가능거리를 전송한다. 열차제어정보전송은 직접 궤도를 이용하여 차상에 전송하는 방식, 궤도상에 기기를 설치하여 전송하는 방식, 선로변에 기기를 전송하는 방식이 있다. 직접궤도를 도체로 활용하여 궤도를 회로일부로 구성하고, 궤도에 신호를 전송하여 열차가 궤도에서 열차제어 정보를 획득하는 방법으로, 궤도회로를 사용하며, 고속철도, 지하철에서 사용하고 있다. 궤도회로를 사용하는 방식은 반송신호에 정보를 실어서 보내며, 차상장치는 자기결합에 의해서 정보를 획득한다. 콘크리트 슬래브궤도에는 많은 철근을 사용하기 때문에 자갈도상의 궤도에서는 발생되지 않았던 레일과 철근간의 상호작용이 발생한다. 레일과 철근간의 상호작용이 발생하여 레일의 전기적 특성이 변화된다. 본 논문에서는 경부고속철도 2단계 구간에서 사용되는 콘크리트 슬래브궤도에서 레일과 철근 사이의 모델을 이용하여 콘크리트 슬래브궤도의 모델로부터 레일과 철근 사이의 결합계수를 수리적으로 해석하고, 레일과 철근간의 상호작용이 일어나지 않는 경우, 즉 철근에 의한 레일의 전기적 특성의 변화가 없는 결합계수를 정의하였다.

Wind-sand coupling movement induced by strong typhoon and its influences on aerodynamic force distribution of the wind turbine

  • Ke, Shitang;Dong, Yifan;Zhu, Rongkuan;Wang, Tongguang
    • Wind and Structures
    • /
    • 제30권4호
    • /
    • pp.433-450
    • /
    • 2020
  • The strong turbulence characteristic of typhoon not only will significantly change flow field characteristics surrounding the large-scale wind turbine and aerodynamic force distribution on surface, but also may cause morphological evolution of coast dune and thereby form sand storms. A 5MW horizontal-axis wind turbine in a wind power plant of southeastern coastal areas in China was chosen to investigate the distribution law of additional loads caused by wind-sand coupling movement of coast dune at landing of strong typhoons. Firstly, a mesoscale Weather Research and Forecasting (WRF) mode was introduced in for high spatial resolution simulation of typhoon "Megi". Wind speed profile on the boundary layer of typhoon was gained through fitting based on nonlinear least squares and then it was integrated into the user-defined function (UDF) as an entry condition of small-scaled CFD numerical simulation. On this basis, a synchronous iterative modeling of wind field and sand particle combination was carried out by using a continuous phase and discrete phase. Influencing laws of typhoon and normal wind on moving characteristics of sand particles, equivalent pressure distribution mode of structural surface and characteristics of lift resistance coefficient were compared. Results demonstrated that: Compared with normal wind, mesoscale typhoon intensifies the 3D aerodynamic distribution mode on structural surface of wind turbine significantly. Different from wind loads, sand loads mainly impact on 30° ranges at two sides of the lower windward region on the tower. The ratio between sand loads and wind load reaches 3.937% and the maximum sand pressure coefficient is 0.09. The coupling impact effect of strong typhoon and large sand particles is more significant, in which the resistance coefficient of tower is increased by 9.80% to the maximum extent. The maximum resistance coefficient in typhoon field is 13.79% higher than that in the normal wind field.

박막에서의 박막두께에 따른 자기탄성계수의 거동 예측 (Magnetoelastic Coupling Coefficients with Film Thicknesses in Ultrathin Films)

  • 송오성
    • 한국자기학회지
    • /
    • 제5권2호
    • /
    • pp.112-114
    • /
    • 1995
  • 매우 얇은 박막에서 자기탄성계수는 효과이방성에너지와 마찬가지로 박막두께에 반비례하여, B/sup eff/ = B/sup b/ + B/sup s/ /t 으로 수학적, 물리적으로 예측됨을 보였다. 이러한 박막두께가 얇아질수록 표면자기탄성계수(surface magnetoelastic coupling coefficient)에 의한 영향이 커지므로 많은 공학적 의미를 내포하고 있다.

  • PDF

적층 압전 액추에이터의 전기-기계적 특성 분석 (ELECTROMECHANICAL ANALYSIS OF PIEZOELECTRIC STACK ACTUATOR)

  • 하기홍;이수일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.374-378
    • /
    • 2014
  • The piezoelectric materials convert from mechanical energy to electrical energy. The piezoelectric materials are used in various engineering applications such as piezoelectric ultrasonic actuators. Since the piezoelectric coupling characteristics of the actuator systems should be considered at the initial design stage, it is essential to analyze the piezoelectric coupling characteristics of the ultrasonic actuators. In this study, we analyzed the electromechanical characteristics of piezoelectric stacked actuator using the equivalent circuit model with modal mass stiffness parameters. It was compared the admittance of piezoelectric stack actuators with the analytical circuit model and the finite element model. Also, the coupling coefficient of piezoelectric stack actuator was discussed according to the number of stacks of actuators.

  • PDF

Wind-induced responses of Beijing National Stadium

  • Yang, Q.S.;Tian, Y.J.
    • Wind and Structures
    • /
    • 제14권3호
    • /
    • pp.239-252
    • /
    • 2011
  • The wind-induced mean, background and resonant responses of Beijing National Stadium are investigated in this paper. Based on the concepts of potential and kinetic energies, the mode participation factors for the background and the resonant components are presented and the dominant modes are identified. The coupling effect between different modes of the resonant response and the coupling effect between the background and resonant responses are analyzed. The coupling effects between the background and resonant components and between different modes are found all negligible. The mean response is approximately analogous to the peak responses induced by the fluctuating wind. The background responses are significant in the fluctuating responses and it is much larger than the resonant responses at the measurement locations.

Silane Coupling제(劑)와 고분자탄성체간(高分予彈性體間)의 용액반응(溶液反應)에 대한 속도론적(速度論的) 해석(解析) (Kinetic Analysis of Solution Reaction between CR and Silane Coupling Agents)

  • 박영수;윤정식;유종선;백남철
    • Elastomers and Composites
    • /
    • 제25권2호
    • /
    • pp.112-116
    • /
    • 1990
  • In this study, as one way of developing the new cross-linking method that is curable in water, kinetic analysis of solution reaction between CR and silane coupling agents was attemped. First, CR was reacted with silane coupling agents in solution state. According to the time, reaction quantity was pursued by gas chromatography. Also, reaction rate coefficient and activation energy were calculated from the reaction quantity. Silane coupling agents which were used in this study were MPS, CPS and VES.

  • PDF

화재피해를 입은 콘크리트 건축물의 염해 내구수명 산정 (Life Expectation of Salt Attack for Fire Damaged RC Structure)

  • 박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.15-16
    • /
    • 2017
  • The properties of concrete damaged by fire change according to the temperature. Diffusion coefficient of chloride ion also can change which affect the life expectation under salt circumstance. Diffusion coefficient was measured by NT BUILD 492 using the concrete specimen damaged by high temperature. FEM analysis was performed to predict the life expectancy which can help to diagnose the concrete diagnose and to design maintenance strategy.

  • PDF

Efficiency Enhancement of Wireless Power Transfer with Optimum Coupling Mechanism for Mid-range Operation

  • Anowar, Tanbir Ibne;Kumar, Narendra;Ramiah, Harikrishnan;Reza, Ahmed Wasif
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1556-1565
    • /
    • 2017
  • This paper depicts the design, implementation and analysis of efficient resonant based wireless power transfer (WPT) technique using three magnetic coupled coils. This work is suitable for mid ranged device due to small form factor while minimizing the loading effect. A multi turned loop size resonator is exploited for both the transmitter and receiver for longer distance. In this paper, class-E power amplifier (class-E PA) is introduced with an optimum power tracking mechanism of WPT system to enhance the power capability at mid-range with a flat gain. A robust method of finding optimum distance is derived with an experimental analysis of the designed system. In this method, the load sensitive issue of WPT is resolved by tuning coupling coefficient at considerable distances. Our designed PA with a drain efficiency of 77.8% for a maximum output of 5W is used with adopted tuning technique that improves the overall WPT system performance by 3 dB at various operating points.

다단 FSCS를 이용한 초광대역 특성의 대역저지 필터 (Ultra-wideband BSF Using Multi-stage FSCS)

  • 윤태순
    • 한국전자통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.439-444
    • /
    • 2020
  • 본 논문에서는 결합선로와 개방형 스터브를 통해 간단히 구현되는 FSCS의 결합계수에 따른 특성을 분석하고, FSCS로 구현되는 대역저지 필터의 대역저지 대역폭을 향상시키고자 다단의 FSCS를 제안하였다. FSCS는 스터브에 의해 기본 공진 주파수가 결정되며 결합선로의 결합계수에 의해 대역폭을 조절할 수 있다. 논문에서는 결합선로와 스터브의 전기적 길이를 절반으로 하는 FSCS를 추가로 연결하여 다단 FSCS를 구현하였으며, 3단 FSCS로 구성된 대역저지 필터는 저지 대역 177.3% (1.15~12.72GHz)와 저지대역에서의 최대 반사 손실 1dB의 측정 결과를 보였다.