• 제목/요약/키워드: Coupled System

검색결과 3,200건 처리시간 0.027초

교전급 수중운동체 DEVS-HLA 시뮬레이션을 위한 전술통제체계의 DEVS 기반 상세 구현 방법 (The DEVS-based Detailed Implementation Method of the Command and Fire Control System for the Underwater Vehicle DEVS-HLA Simulation in the Engagement Level)

  • 손명조;차주환;김태완;이규열;나영인
    • 대한조선학회논문집
    • /
    • 제47권4호
    • /
    • pp.628-645
    • /
    • 2010
  • To perform the engagement level simulation between the underwater vehicle model and the surface model those are constituted with various systems/ sub-systems, we implemented four different federates as a federation according to the IEEE 1516 HLA (High Level Architecture) protocol that is the international standard in the distributed simulation. Those are CFCS (Command and Fire Control System) federate, motion federate, external entities (torpedos, countermeasure and surfaceship) federate, and visualization federate that interacts with OSG (Open Scene Graph)-based visualization rendering module. In this paper, we present the detailed method about the model constitution for discrete event simulation in the distributed environment. For the sake of this purpose, we introduce the DEVS (Discrete Event System Specification)-HLA-based modeling method of the CFCS federate that reflects not only the interations between models, but also commands from user and tactics manager that is separated from the model. The CFCS federate makes decisions in various missions such as the normal diving, the barrier misision, the target motion analysis, the torpedo launch, and the torpedo evasion. In the perspective of DEVS modeling, the CFCS federate is the coupled model that has the tactical data process model, command model and fire control model as an atomic model. The message passing and time synchronization with other three federates are settled by the $m\ddot{a}k$ RTI (Runtime Infrastructure) that supports IEEE 1516. In this paper, we provides the detailed modeling method of the complicated model that has hierarchical relationship such as the CFCS system in the submarine and that satisfies both of DEVS modeling method for the discrete event simulation and HLA modeling method for the distributed simulation.

우리나라 근해 대형트롤 어선의 선교업무 특성 (Characteristics of bridge task in Korean coastal large trawler)

  • 김민선;신현옥;이주희;황보규
    • 수산해양기술연구
    • /
    • 제49권3호
    • /
    • pp.301-310
    • /
    • 2013
  • To suggest a standard concerning with the arrangement of bridge equipment, the authors conducted the video observations with 3CCD (charge coupled device) cameras installed on the ceil of the bridge for monitoring the working activities of two bridge teams (the skipper/mate1 and the skipper/mate2) in a Korean coastal large trawler(gross tonnage: 139) for five days from July 30th. 2010 and analyzed of the data. Work elements coded by the work activities were input on the sheet of work analysis by the time unit of 1 sec according to the time occurred. A single work element among the work activities for every 5 minutes was denoted as the number of occurrence. The frequency of equipment usage was limited only in the usage of the equipment. In the case of the navigation and the towing net two ranks were integrated and analyzed. On the other hand, in the case of the casting net and the hauling net, two processes were integrated to as one and then analyzed separately as two ranks. As the results, 15 elements of work was carried out between two bridge teams for the observation; lookout, radar, GPS plotter, fish finder, net monitor, fishing deck, RPM indicator, rudder angle indicator, compass card, for maneuver; steering, ship speed control, trawl winch operation and external communications, paper works and others. It was found that the work load of the skipper per 5 minutes accordance with the navigation, the casting net, the towing net and the hauling net are 20.5 times, 11.9 times, 38.0 times and 9.5 times respectively, the mates are 65.2 times, 66.5 times, 85.7 times and 59.1 times respectively. The radar was shown the highest frequency of the equipment usage and the next was the fish finder, the GPS plotter and the external communications in the case of the navigation. In the case of the towing net the frequency of usage was high the ranking as the radar, the net monitor, the fish finder, the GPS plotter, the steering system and the external communications. In the case of the integrated process both of the casting and hauling net the trawl winch was shown the highest frequency to the skipper and the next was the GPS plotter and the radar, and the steering system was shown the highest frequency to the mate and the next was the radar, the ship speed control system, the GPS plotter, the net monitor and the fish finder.

Ubiquitous Sensor Network 및 Social Sensor Networking을 이용한 도시 에너지 모니터링 가시화 시스템 설계 (System Design for a Urban Energy Monitoring and Visualization Environment Using Ubiquitous Sensor Network and Social Sensor Networking)

  • 최윤;장명호;김성아
    • 한국HCI학회논문지
    • /
    • 제5권2호
    • /
    • pp.7-14
    • /
    • 2010
  • 센서 네트워크에 의해 수집되는 다양한 도시 데이터는 도시를 이해하고 분석하는데 있어서 필수적인 수단으로 자리매김하고 있다. 특히 Ubiquitous Sensor Network(USN) 기술들은 u-City 구현에 있어 중추신경망을 제공하였다. 이 연구는 도시 에너지의 사용량에 관한 정보를 USN을 이용하여 수집하고, 이를 도시공간정보와 연계된 직관적 가시화 환경을 통해 제공함으로써 u-City에서 에너지 공급계획을 수립, 모니터링하고, 궁극적으로 실사용자가 능동적으로 에너지를 절약할 수 있도록 도와주는 애플리케이션 구현을 목적으로 한다. 특히 3차원 지리정보환경의 층위에 다층적인 에너지 모니터링 정보를 동적으로 조합하면서 다양한 사용자의 관점에 대응하는 환경을 제시하였다. 또한 도시공간정보에 기반을 둔 논리적 LOD를 제공함으로써 효과적인 실시간 에너지 사용 모니터링 도구를 제공한다. 이를 위하여 관련 선행연구를 분석하여 어플리케이션 구현을 위한 시스템의 개념과 구성을 정의하고 데이터 구조 및 가시화방안을 구체화하였다. 본 논문에서는 특히 시스템 구현에 요구되는 공간정보, E-GIS 데이터, 에너지 사용량 센서 데이터를 효과적으로 조합하는 가시화 방법론, 직관적 표현방법, 데이터 구조 및 어플리케이션의 연구결과를 제시하고 Social Sensor Networking을 이용한 모니터링 확장 적용방안에 대해 연구한다.

  • PDF

주사본 권한을 이용한 동적 트랜잭션 분배 알고리즘 (A Dynamic Transaction Routing Algorithm with Primary Copy Authority)

  • 김기형;조행래;남영환
    • 정보처리학회논문지D
    • /
    • 제10D권7호
    • /
    • pp.1067-1076
    • /
    • 2003
  • 데이터베이스 공유 시스템(Database Sharing System: DSS)은 고성능 트랜잭션 처리를 위해 제안된 시스템이다. DSS에서 고속의 통신망으로 연결된 노드들은 별도의 메모리와 운영체제를 가지며, 데이터베이스를 저장하고 있는 디스크는 모든 노드에 의해 공유된다. 그리고 빈번한 디스크 액세스를 피하기 위해 각 노드는 자신의 메모리 버퍼에 최근에 액세스한 페이지들을 캐싱한다. 본 논문에서는 DSS를 구성하고 있는 각 노드의 부하를 효과적으로 분산한 수 있는 동적 트랜잭션 분배 알고리즘을 제안한다. 제안한 알고리즘은 각 노드에 할당된 주사본 권한을 이용함으로써 노드별 참조 지역성을 지원하고, 그 결과 캐쉬 이용률을 증가하여 디스크 액세스 수를 최소화한다. 뿐만 아니라, 노드의 현재 부하를 고려하여 트랜잭션 분배 정책을 결정함으로써 특정 노드에 트랜잭션이 집중되는 것을 피한다. 제안된 알고리즘의 성능평가를 위해 시뮬레이션 실험을 수행하였으며, 실험결과 제안된 알고리즘이 기존 알고리즘들보다 트랜잭션 처리율에서 높은 성능을 보였다. 특히 트랜잭션 부하량이 높은 경우와 편중된 데이터 참조를 보이는 경우에 좋은 성능을 보였다.

77 GHz 차량용 레이더 시스템 설계 (Design of 77 GHz Automotive Radar System)

  • 남형기;강현상;송의종;;김성균;남상욱;김병성
    • 한국전자파학회논문지
    • /
    • 제24권9호
    • /
    • pp.936-943
    • /
    • 2013
  • 본 논문에서는 76.5~77 GHz 대역 차량용 장거리 주파수 변조 연속파 레이더 응용을 위한 단일 채널 레이더 시스템의 설계와 측정 결과를 보인다. 송신기는 상용 GaAs MMIC를 사용하였고, 수신기는 65 nm CMOS 공정을 사용해 설계한 회로를 사용하였다. 제작된 하향 변환 수신 칩은 -8 dBm의 낮은 LO 전력으로 동작하기 때문에, 송신출력에서 -19 dB 방향성 결합기를 사용하여 믹서를 구동하였다. 모든 MMIC는 WR-10 도파관이 형성되어 있는 알루미늄 지그 위에 실장하였으며, 마이크로스트립-도파관 급전기를 통해 혼 안테나를 구동하여 실험하였다. 제작된 레이더 시스템의 크기는 $80mm{\times}61mm{\times}21mm$이고, 출력 전력은 10 dBm, 위상 잡음은 1 MHz 오프셋에서 -94 dBc/Hz, 그리고 수신기의 변환이득은 12 dB이다.

AHP 기법을 이용한 수행영향인자 평가에 관한 연구 (An Empirical Study on Evaluation of Performance Shaping Factors on AHP)

  • 정경희;변승남;김정호;허은미;박홍준
    • 대한인간공학회지
    • /
    • 제30권1호
    • /
    • pp.99-108
    • /
    • 2011
  • Almost all companies have paid much attention to the safety management ranging from maintenance to operation even at the stage of designing in order to prevent accidents, but fatal accidents continue to increase throughout the world. In particular, it is essential to systematically prevent such fatal accidents as fire, explosion or leakage of toxic gas at factories in order to not only protect the workers and neighbors but also prevent economic losses and environmental pollution. Though it is well known that accident probability is very low in NPP(Nuclear Power Plants), the reason why many researches are still being performed about the accidents is the results may be so severe. HRA is the main process to make preparation for possibility of human error in designing of the NPP. But those techniques have some problems and limitation as follows; the evaluation sensitivity of those techniques are out of date. And the evaluation of human error is not coupled with the design process. Additionally, the scope of the human error which has to be included in reliability assessment should be expanded. This work focuses on the coincidence of human error and mechanical failure for some important performance shaping factors to propose a method for improving safety effectively of the process industries. In order to apply in these purposes into the thesis, I found 63 critical Performance Shaping Factors of the eight dimensions throughout studies that I executed earlier. In this study, various analysis of opinion of specialists(Personal Factors, Training, Knowledge or Experience, Procedures and Documentation, Information, Communications, HMI, Workplace Design, Quality of Environment, Team Factors) and the guideline for construction of PSF were accomplished. The selected method was AHP which simplifies objective conclusions by maintaining consistency. This research focused on the implementation process of PSF to evaluate the process of PSF at each phase. As a result, we propose an evaluation model of PSF as a tool to find critical problem at each phase and improve on how to resolve the problems found at each phase. This evaluation model makes it possible to extraction of PSF succesfully by presenting the basis of assessment which will be used by enterprises to minimize the trial and error of construction process of PSF.

Exposure to Particles and Nitrogen Dioxide Among Workers in the Stockholm Underground Train System

  • Plato, N.;Bigert, C.;Larsson, B.M.;Alderling, M.;Svartengren, M.;Gustavsson, P.
    • Safety and Health at Work
    • /
    • 제10권3호
    • /
    • pp.377-383
    • /
    • 2019
  • Objectives: Exposure to fine particles in urban air has been associated with a number of negative health effects. High levels of fine particles have been detected at underground stations in big cities. We investigated the exposure conditions in four occupational groups in the Stockholm underground train system to identify high-exposed groups and study variations in exposure. Methods: $PM_1$ and $PM_{2.5}$ were measured during three full work shifts on 44 underground workers. Fluctuations in exposure were monitored by a real-time particle monitoring instrument, pDR, DataRAM. Qualitative analysis of particle content was performed using inductively coupled plasma mass spectrometry. Nitrogen dioxide was measured using passive monitors. Results: For all underground workers, the geometric mean (GM) of $PM_1$ was $18{\mu}g/m^3$ and of $PM_{2.5}$ was $37{\mu}g/m^3$. The particle exposure was highest for cleaners/platform workers, and the GM of $PM_1$ was $31.6{\mu}g/m^3$ [geometric standard deviation (GSD), 1.6] and of $PM_{2.5}$ was $76.5{\mu}g/m^3$ (GSD, 1.3); the particle exposure was lowest for ticket sellers, and the GM of $PM_1$ was $4.9{\mu}g/m^3$ (GSD, 2.1) and of $PM_{2.5}$ was $9.3{\mu}g/m^3$ (GSD, 1.5). The $PM_1$ and $PM_{2.5}$ levels were five times higher in the underground system than at the street level, and the particles in the underground had high iron content. The train driver's nitrogen dioxide exposure level was $64.1{\mu}g/m^3$ (GSD, 1.5). Conclusions: Cleaners and other platform workers were statistically significantly more exposed to particles than train drivers or ticket sellers. Particle concentrations ($PM_{2.5}$) in the Stockholm underground system were within the same range as in the New York underground system but were much lower than in several older underground systems around the world.

막결합형 2상 혐기성 소화 공정을 이용한 음식물 탈리액 처리 (Treatment of Garbage Leachate with Two-phase Anaerobic Digestion Coupled with Ultra Filtration)

  • 이은영;김형국;티투이장;배재호;배영신;원종철;이재훈;박성균;조용완
    • 대한환경공학회지
    • /
    • 제31권11호
    • /
    • pp.997-1006
    • /
    • 2009
  • 본 연구에서는 음폐수를 대상으로 5 톤/일 처리규모의 막결합형 2상 혐기성 소화(TPADUF) 플랜트를 운영하며 유기물 제거효율 및 메탄 발생량을 파악하고, 소화가스를 이용한 발전 가능성 및 분리막 적정 운영방안을 검토하였다. 고온 산발효조, 중온 메탄조 및 UF 막으로 구성된 처리 시스템에서 평균 TCOD가 150 g/L인 음폐수를 유기물 부하 11.1 g COD/L/d까지 증가시키며 처리한 결과 최종 유출수의 TCOD는 6 g/L 이하이었으며, TCOD 및 SCOD 제거효율은 모두 95% 이상이었다. 소화 가스의 메탄 구성비는 65%이었으며, 회수된 메탄량은 시스템에서 일부 가스가 누출되었음에도 39 $m^3/m^3$ 음폐수 주입량, 260 $m^3$/톤 COD유입량, 또는 270 $m^3$/톤 COD제거량 이었다. 소모된 가스량 당 발전량은 0.96 kWh/$m^3$ 가스, 또는 1.49 kWh/$m^3$ 메탄으로 다소 낮았으나 이는 소용량 발전기(15 kW급)의 저효율에 기인한 것이다. 분리막은 평균 flux 10 L/$m^2$/hr에서 운전하였으며, 운전 중 flux가 감소하였을 때는 물 또는 화학적(NaOCl)세정을 실시하여 회복시킬 수 있었다. TPADUF 플랜트에서는 메탄조 내액 또는 분리막 농축액을 산발효조로 반송함으로써 산발효조의 pH를 별도의 약품 주입 없이 적정 수준을 유지할 수 있었으며, 산발효조에서 부분적인 메탄생성을 통해 메탄조의 유기물 부하를 낮추는 효과도 있었다.

도서관의 이용패턴과 서비스품질이 정보화성과지각 및 만족에 미치는 영향 (The Effects of Use Patterns and Service Quality on Performance and Use Satisfaction on Library Information System)

  • 정형식;염승엽
    • 마케팅과학연구
    • /
    • 제18권4호
    • /
    • pp.217-244
    • /
    • 2008
  • 전자정보기술의 발달로 인해 도서관 서비스제공은 정보화시스템에 대한 의존 비중이 커져가고 있다. 이러한 상황의 변화에 따라 본 연구는 이용자의 도서관 정보화에 대한 성과지각과 정보화를 통한 이용 만족은 전반적 만족에 중요한 선행요인이 될 것으로 추론하였다. 뿐만 아니라 기존 연구는 대체로 도서관의 서비스제공측면에서 이용자의 인식이나 만족을 조사하였으나 본 연구는 시각을 달리하여 이용자측면에서 단순 열람목적의 일반적 이용과, 전문정보구득 목적의 전문적 이용패턴이 정보화 성과지각에 어떻게 다르게 영향을 미치는지에 대해서 조사하였다. 또한 서비스품질차원이 정보화성과지각과 이용만족에 미치는 영향을 조사하였다. 마지막으로 서비스품질차원이 정보화성과지각과 이용만족에 미치는 영향을 확인하였다. 본 연구의 실증분석 결과는 첫째, 도서관 이용자의 열람 등 일반적 목적 이용이 정보화성과지각에 영향을 미치는지 검증하고자 하였으나 유의한 수준에 미치지 못했다. 둘째, 도서관 이용자의 특정 정보구득 등 전문적 목적의 이용이 정보화성과지각에 유의한 정의 영향을 미쳤다. 셋째, 일반적 서비스품질인 상호작용품질, 결과품질, 물리적환경품질 차원은 정보화성과지각에 유의한 영향을 미쳤으나 정보화이용만족에는 유의하지 않았다. 마지막으로, 도서관 이용자의 정보화성과지각과 정보화이용만족이 전반적인 만족을 선행하고 있음을 밝혔다. 이를 통해 도서관의 정보화시스템을 어떻게 이용자중심으로 체계화하여 발전시킬 것인지에 대해 심층적인 고찰이 필요함을 확인하였다.

  • PDF

초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상 (Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings)

  • 조순호
    • 한국지진공학회논문집
    • /
    • 제12권4호
    • /
    • pp.19-33
    • /
    • 2008
  • 구조물에 고유한 진동수,모드형태 및 감쇠비 등과 같은 동적성능치를 추출하기 위하여 25층 및 42층 건물에 대하여 자연진동에 의한 동적계측실험을 수행하였다. 고려된 건물은 주요 횡하중 지지기구로서 코아벽체 혹은 전단벽체가 추가된 철근콘크리트건물이며, 입면 혹은 평면상으로 골조가 혼합된 구조형식을 나타낸다. 특히, 25층 건물은 측면에 위치한 코아벽체 이외에 상부로부터 내려오는 전단벽 구조가 4층 바닥이하에서 골조형식으로 전환되는 복잡한 구조이다. 이와 같은 이유 및 건물 주방향의 유사한 강성배치로 매우 근접하고 혼합된 모드형태가 예상되어 시스템판별 시 어려움이 예상된다. 현재까지 개발된 다양한 시스템판별법을 대상건물의 자연진동 실측기록에 적용하여 모달계수를 유도하였으며, 그 결과를 비교 분석하였다. 3개의 주파수영역 및 4개의 시간영역에 근거한 응답의존 시스템판별법이 고려되었다. 서로 다른 시스템판별법에 의하여 추출된 고유진동수 및 감쇠비는 대체로 상당한 일치를 보였으나, 모드형태는 사용된 방법에 따라 정도가 다르게 불일치를 나타냈다. 실험으로부터 추출한 성능치와 초기 유한요소해석 값을 비교해 본 결과 대상건물 모두 적어도 저차 3개의 고유진동수에서 2배 정도의 차이를 나타냈다. 실험과 해석결과의 일치를 위하여 몇몇 수동모델향상이 시도되었으며, 허용할 만한 결과를 획득하였다. 사용된 시스템판별법에 대하여 각자의 장, 단점에 대하여 기술하였으며, 본 연구와 같은 실제 대형구조물에 대하여 자동모델향상기법을 적용할 시 예상되는 문제점에 대하여 토의하였다.