• Title/Summary/Keyword: Counts Rate

Search Result 495, Processing Time 0.027 seconds

Study on the Usefulness of Using Anterior and Posterior Views for Calculation of Total Relative Uptake Ratio in 99mTc-DMSA Renal Scan (99mTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰)

  • Kim, Joo-Yeon;Lee, Han-Wool;Kwon, O-Jun;Kim, Jung-Yul;Park, Min-Soo;Cho, Seok-Won;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose $^{99m}Tc-DMSA$ renal scintigraphy serves as location, size and shape of kidney, so it has been used for diagnosis and passage observation after the operation or treatment. There are 3 methods of calculating the relative renal uptake ratio such as geometric mean of the counts from the anterior and posterior views, arithmetical mean from the only posterior view and posterior view which applied the renal depths. In this study, we seek to correlation between the change of total relative uptake ratio according to different inspection methods of obtaining the renal count rate. Materials and Methods The phantom experiments proceeded 5 times depending on each renal depth with the kidney phantom and tissue equivalent materials. In the clinical research, we investigated 36 adult patients who had visited our hospital from february to october, 2014 and received $^{99m}Tc-DMSA$ renal scan. The equipment was used as a gamma camera named INFINIA (General Electric Healthcare, milwaukee, USA) and we drew the region of interests through semiautomatic method by using Xeleris Ver. 2.1220 of GE. In addition, we obtained the lateral view of kidney to measure the renal depth of each patient. Then the results were compared with 3 methods of calculating relative renal uptake ratio. Results The phantom studies show when the difference between the left ant right kidney depth were less than 1 cm, there were no statistically significant difference among values calculated through anterior and posterior views and only posterior view (P>0.05), while the excess of 1cm, the results showed a statistically significant change in the value (P<0.05). In case of clinical research, the correlation between total relative uptake ratio by obtaining both sides of image and posterior view applied the kidney depth (r=0.999) was higher than by obtaining only posterior view and applying the kidney depth to one side image (r=0.988). Conclusion This study has found that, the difference of calculating total relative uptake ratio compared with obtaining anterior and posterior views and only posterior view. In order to reduce the error, we recommend the method of obtaining anterior and posterior views and is considered to be useful, particularly the patients have similar uptake ratio of left and right kidney and difficulties of measurements of kidney depth.

  • PDF

A Study on the Correlation between Lung Ventilation Scan using Technegas and Pulmonary Function Test in Patients with COPD (Technegas를 이용한 폐환기 검사와 폐기능 검사의 상관관계에 관한 고찰)

  • Kim, Sang-Gyu;Kim, Jin-Gu;Baek, Song-EE;Kang, Chun-Koo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.45-49
    • /
    • 2019
  • Purpose Lung Ventilation Scan(LVS) images directly inhaled radiation gas to evaluate lung ventilation ability. Therefore, it is influenced by various factors related to inhalation, including number of breaths, respiratory duration, respiration rate, and breathing method. In actual LVS examinations, it is difficult for objectify the patient's ability to inhale, and there is currently no known index related to inhalation. Therefore, this study confirms the correlation between counts per second(cps) in LVS and the results of pulmonary function test(PFT) and evaluate its usefulness as an objective indicator of inhalation. Materials and Methods From October 2010 to September 2018, 36 Chronic Obstructive Pulmonary Disease(COPD) patients who had both LVS and PFT were classified by severity(Mild, Moderate, Severe). LVS was performed by creating Technegas with Vita Medical's Technegas Generator and inhaling it to the patient. LVS images were acquired with Philips's Forte equipment., and PFT used Carefusion's Vmax Encore 22. The correlation between the cps measured by setting the region of interest(ROI) of both lungs on the LVS and the forced vital capacity(FVC), forced expiratory volume in one second($FEV_1$), $FEV_1/FVC$ of the results of PFT was compared and analyzed. Results We analyzed the correlation between cps of LVS using Technegas and the results of PFT by classifying COPD patients according to severity. Correlation coefficient between $FEV_1/FVC$ and cps was Severe -0.773, Moderate -0.750, and Mild -0.437. The Severe and Modulate result values were statistically significant(P<0.05) and Mild was not significant(P=0.155). On the other hand, the correlation coefficient between FVC and cps was statistically significant only in Mild and it was 0.882(P<0.05). Conclusion According to the study, we were able to analyze correlation between cps of LVS using Technegas and the results of PFT in COPD Patients. Using this result, when performing a LVS, the results of PFT can be used as an index of inhaling capacity. In addition, it is thought that it will be more effective for the operation of the exam rooms.

THE EFFECT OF TRANSFORMING GROWTH $FACTOR-B_1$ ON THE PROLIFERATION RATE OF HUMAN PERIODONTAL LIGAMENT CELLS AND HUMAN GINGIVAL FIBROBLASTS. (변형성장인자-${\beta}_1$이 치주인대세포와 치은섬유아세포의 증식에 미치는 영향)

  • Cho, Eun-Kyeung;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.720-732
    • /
    • 1995
  • The use of transforming growth $factor-{\beta}1$ which functions as a potent biologic mediator regulating numerous activities of wound healing has been suggested for the promotion of periodontal regeneration. The mitogenic effects of transforming growth $factor-{\beta}1$ on human periodontal ligament cells and human gingival fibroblasts were evaluated by determining the incorporation of $[^3H]-thymidine$ into DNA of the cells dose-dependently. Cells were prepared with primary cultured fibroblasts and periodontal ligament cells from humans, and used in experiments were the fourth or sixth subpassage. Cells were seeded with serum free Dulbecco's modified Eagle medium containing 0.1% bovine serum albumine. The added concentrations of transforming growth $factor-{\beta}1$ were 0.25, 0.5, 1, 2.5, 5ng/ml and transforming growth $factor-{\beta}1$ were added to the quiescent cells for 24hours, 48hours, 72hours. They were labeled with lnCi/ml $[^3H]$ thymidine for the last 24hour of the each culture. The results were presented as the mean counts per minute (CPM) per well and S.D. of four determinations. The results were as follows. : The DNA synthetic activity of human gingival fibroblasts was increased dose-dependently by transforming growth $factor-{\beta}1$ at 24 hours, 48 hours and 72 hours. The maximum mitogenic effects were at the 48 hour application of transforming growth $factor-{\beta}1$. The DNA synthetic activity was generally more decreased at the 72 hour application than at the 48 hour the application of transforming growth $factor-{\beta}1$. The DNA synthetic activity of human periodontal ligament cells was increased dose-dependently by transforming growth $factor-{\beta}1$ at 24 hours and 48 hours. But the DNA synthetic activity was decreased at 5ng/ml of the 72 hour application. The maximum mitogenic effects were also at the 48 hour application of transforming growth $factor-{\beta}1$. The DNA synthetic activity of human periodontal ligament cells was generally more decreased at the 72 hour application than at the 48 hour application of transforming growth $factor-{\beta}1$. In the comparision of DNA synthetic activity between the human gingival fibroblasts and human periodontal ligament cells, the human gingival fibroblasts had more activity than the human periodontal ligament cells at all time application with the concentration of transforming growth $factor-{\beta}1$. In conclusion, transforming growth $factor-{\beta}1$ has an important roles in the stimulation of DNA synthesis in human periodontal ligament cells and human gingival fibroblasts, which means an increase in collagen synthesizing cells and thus, may be useful for clinical application in periodontal regenerative procedures.

  • PDF

Comparison of Dietary Patterns, Health, and Blood Parameters of Elderly Women and College Women in the Seoul Area (노화 과정에 따른 노인과 여대생의 식생활, 건강 상태 및 혈액 성상 비교 연구)

  • Shin, Kyung-Ok;Chung, Keun-Hee;Choi, Kyung-Soon
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.19 no.5
    • /
    • pp.703-712
    • /
    • 2009
  • The principal objective of this study was to supply basic material determine basic information regarding effective health promotion regimens for elderly women via a comparative survey of health status by aging age between elderly women (=70 y) and college women. The subject groups of elderly women (=70 y) and college women were selected and surveyed from March to October, 2008, in the Seoul area. The average age of the elderly women assessed in this study was $78.64{\pm}7.30$, the average height was $147.07{\pm}5.72$ cm, and the average weight was $50.47{\pm}7.44$ kg. As compared with college women, a higher percentage of elderly women ate breakfast regularly, but the elderly women also experienced difficulties in chewing due to dentures, and therefore ate their meals with large quantities of liquids, and usually ate their meals within 10 minutes. The majority of elderly women suffered from at least one disease, and the most common symptom reported was hypertension (25%). 52.2% of elderly women and 47.8% of college women reported that they exercised 1~2 times per week. They reported that their favorite exercise was light exercise, such as jogging and athletics (73.1%). As compared with college women, the smoking rate was lower among elderly women, but some of the elderly women were long-time smokers or alcoholics. The differences in red blood cells counts, Hb, hematocrit, and MCV of the between elderly women and college women were significant. In addition, but the MCH and MCHC were higher in elderly women compared with college women and the total cholesterol of elderly woman ($175.62{\pm}38.89$ mg/dL) was significantly lower compared with college woman ($186.13{\pm}28.19$ mg/dL). TG ($127.89{\pm}51.25$ mg/dL) and LDL-cholesterol ($120.51{\pm}32.88$ mg/dL) of elderly woman were significantly higher than TG ($79.71{\pm}40.9$ 6mg/dL) and LDL-cholesterol($103.78{\pm}22.94$ mg/dL) of college woman (p<0.05). The levels of HDL-cholesterol ($58.78{\pm}12.90$ mg/dL) in the college women was significantly higher than the HDLcholesterol levels ($48.17{\pm}13.79$ mg/dL) of the elderly women (p<0.05). Serum vitamin C levels in elderly women were significantly higher than those of college women (p<0.05), whereas no significant difference was detected between the two groups. Consequently, it can be concluded that the appropriate education programs for dietary habits and health promotion are necessary for a healthier life. Additionally, it is necessary for individuals to precisely determine precisely their own health status, and develop appropriate dietary programs for themselves.

  • PDF

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.