Inactivation and Filtration of Bioaerosols Using Carbon Fiber Ionizer Assisted Activated Carbon Fiber Filter (탄소섬유 이오나이저를 적용한 활성탄소섬유 필터의 바이오에어로졸 항균 및 집진 성능평가)

  • Kim, Doo Young;Park, Jae Hong;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.6 no.4
    • /
    • pp.185-192
    • /
    • 2010
  • This paper reports that the installation of a carbon fiber ionizer in front of an activated carbon fiber(ACF) filter enhanced the antibacterial efficiency. In addition, the effect of the ionizer on the filtration of bioaerosols is reported. Negative air ions from the ionizer were used as antibacterial agent. The test bacteria(Escherichia coli) were aerosolized using an atomizer and were deposited on the ACF filter media for 10 minutes. E. coli deposited on the filter were exposed to negative air ions for 0, 1, 5 and 10 minutes. Then they were separated from the ACF filter by shaking incubation with nutrient broth for 4 hours. The separated E. coli were spread on nutrient agar plates and incubated at $37^{\circ}C$ for 1~3 days. The antibacterial efficiency of E. coli was measured using a colony counting method. The antibacterial efficiencies of E. coli exposed to negative air ions for 1, 5 and 10 minutes were 14%, 48% and 71%, respectively. The filtration efficiency was evaluated by measuring the number concentration of bioaerosols at the upstream and downstream of the filter media. The increase of filtration efficiency by air ions was 14%, that is similar to the 17% filtration efficiency by none air ions. The ozone concentration was below the detection limit (under 0.01ppm) when the carbon fiber ionizers were on.

Corrections of Self-Absorption Effect Using the Monte Carlo Method in the Radioactivity Analysis of Environmental Samples (환경시료의 방사능 분석에서 Monte Carlo 방법을 이용한 자체흡수 효과 보정)

  • Seo, Bum-Kyoung;Lee, Dae-Won;Lee, Kil-Yong;Yoon, Yoon-Yeol;Yang, Tae-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.51-58
    • /
    • 2001
  • In the low level radioactivity measurement, such as environmental radioactivity, there were used commonly cylindrical and Marinelli type beakers by means of measurement container. If there are differences in the matrix density or sample height between standard source and sample, it must be determined full energy peak efficiency considering self absorption effect. In this paper, we compared measured efficiency with calculated full energy peak efficiencies in the HPGe detector using the Monte Carlo method. For cylindrical container, we calculated the variation of the efficiency with sample height. Also, we calculated the variation of the detection efficiency with apparent density in the cylindrical and Marinelli container. It was seen that it need to be corrected for self absorption in the energy range of below 1000keV. Also, in order to verify the validity of calculation, we compared the calculated value with reference value using NIST SRM 4353 reference soil.

  • PDF

Comparison of knife-edge and multi-slit camera for proton beam range verification by Monte Carlo simulation

  • Park, Jong Hoon;Kim, Sung Hun;Ku, Youngmo;Lee, Hyun Su;Kim, Chan Hyeong;Shin, Dong Ho;Jeong, Jong Hwi
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.533-538
    • /
    • 2019
  • The mechanical-collimation imaging is the most mature technology in prompt gamma (PG) imaging which is considered the most promising technology for beam range verification in proton therapy. The purpose of the present study is to compare the performances of two mechanical-collimation PG cameras, knife-edge (KE) camera and multi-slit (MS) camera. For this, the PG cameras were modeled by Geant4 Monte Carlo code, and the performances of the cameras were compared for imaginary point and line sources and for proton beams incident on a cylindrical PMMA phantom. From the simulation results, the KE camera was found to show higher counting efficiency than the MS camera, being able to estimate the beam range even for $10^7$ protons. Our results, however, confirmed that in order to estimate the beam range correctly, the KE camera should be aligned, at least approximately, to the location of the proton beam range. The MS camera was found to show lower efficiency, being able to estimate the beam range correctly only when the number of the protons is at least $10^8$. For enough number of protons, however, the MS camera estimated the beam range correctly, errors being less than 1.2 mm, regardless of the location of the camera.

Absolute $^{56}Mn$ Activity Measurement by $4{\pi}{\beta}-{\gamma}$ Conincidence Counting Technique ($4{\pi}{\beta}-{\gamma}$ 동시계수기술에 의한 $^{56}Mn$방사능 절대측정)

  • Hwang, Sun-Tae;Choi, Kil-Oung;Oh, Pil-Jae;Lee, Kyung-Ju;Lee, Kun-Jai
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.2
    • /
    • pp.19-27
    • /
    • 1987
  • In order to determine the $^{56}Mn\;{\gamma}$-detection efficiency of a $MnSO_4$ bath system, it is essential to do the absolute activity measurement of $^{56}Mn$ solution. For the fabrication of $^{56}Mn$ samples, a 13.718 mg of $^{56}Mn$ metal flake with 99.99% purity was irradiated for 12 minutes at the thermal neutron field of about $10^{13}n/cm^2s$ of flux density. The neutron activated $^{56}Mn$ metal sample was dissolved in 50 ml of 0.1 N-HCl solution. The $^{56}Mn$ samples were fabricated by using the dissolved stock solution and the activity of each of them was measured by the $4{\pi}{\beta}-{\gamma}$ coincidence counting technique. The obtained result was 408.070 kBq/mg with total uncertainty of 0.366% at reference date, 0 h on October 15, 1987.

  • PDF

Polarized Light Emission of Liquid Crystalline Polymer Blends (액정성 고분자 블렌드의 편발광)

  • 김영철;조현남;김동영;홍재민;송남웅
    • Polymer(Korea)
    • /
    • v.24 no.2
    • /
    • pp.211-219
    • /
    • 2000
  • Fluorene-based light emitting polymer blends with liquid crystalline characteristics were studied on effective energy transfer and dichroic characteristics. Incorporating 0.5 wt% of the non-liquid crystalline into the liquid crystalline polymer suppressed the PL emission at 420 nm on photoexcitation at 360 nm, but generated a new PL emission of the non-liquid crystalline polymer at 480 nm. The highest PL intensity at 480 nm, which was 13 times stronger than those of the two polymers before blending, was observed for a blend with 2.0 wt% of the non-liquid crystalline polymer. When the molecules of the blends were aligned on a rubbed polyimide surface by a heating-cooling process, the dichroic ratio and the order parameter were 2.0 and 0.25, respectively. Time-correlated single photon counting (TCSPC) study revealed that the time required for energy transfer between the two chromophores was shortened by 93 ps when the blends were aligned on the rubbed polyimide surface by the heating-cooling process. The thermal treatment also enhanced the energy transfer efficiency by 9%.

  • PDF

A novel ceramic GEM used for neutron detection

  • Zhou, Jianrong;Zhou, Xiaojuan;Zhou, Jianjin;Jiang, Xingfen;Yang, Jianqing;Zhu, Lin;Yang, Wenqin;Yang, Tao;Xu, Hong;Xia, Yuanguang;Yang, Gui-an;Xie, Yuguang;Huang, Chaoqiang;Hu, Bitao;Sun, Zhijia;Chen, Yuanbo
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1277-1281
    • /
    • 2020
  • A novel ceramic Gas Electron Multiplier (GEM) has been developed to meet the demand of high counting rate for the neutron detection which is an alternative to 3He-based detector at China Spallation Neutron Source (CSNS). An experiment was performed to measure the neutron transmittance of ceramic-GEM and FR4-GEM at the small angle neutron scattering (SANS) instrument. The result showed the ceramic-GEM has higher transmittance and less self-scattering especially for cold neutrons. One single ceramic GEM could give a gain of 102-104 in the mixture gas of Ar and CO2 (90%:10%) and its energy resolution was about 27.7% by using 55Fe X ray of 5.9 keV. A prototype has been developed in order to investigate the performances of the ceramic GEM-based neutron detector. Several neutron beam tests, including detection efficiency, spatial resolution, two-dimensional imaging, and wavelength spectrum, were carried out at CSNS and China Mianyang Research Reactor (CMRR). The results show that the ceramic GEM-based neutron detector is a good candidate to measure the high intensity neutrons.

Absolute Activity Measurement of $^{137}Cs$ Solution by the Tracer Method (추적자 방법에 의한 $^{137}Cs$용액의 방사능 절대측정)

  • Park, Tae-Soon;Oh, Pil-Jae;Hwang, Sun-Tae;Lee, Kun-Jai
    • Nuclear Engineering and Technology
    • /
    • v.19 no.2
    • /
    • pp.107-114
    • /
    • 1987
  • Using a solution of $^{137}$ Cs as a tracer, radioactivity of a $^{137}$ Cs solution is measured by coincidence and anticoincidence counting methods. Sample sources in this study are fabricated by mixing $^{137}$ Cs with tracer, and the mixing ratios are 1/3 and 1/5, respectively in coincidence and anticoincidence methods. Specific activities of a $^{137}$ Cs solution are calculated by means of f-channel low energy threshold level variation and efficiency extrapolation. The results obtained by coincidence and anticoincidence counting methods are 552.78 kBq/g and 554.32kBq/g, respectively on the reference date and the combined uncertainties are 1.60kBq/g and 1.51kBq/g for each method. These two results show a good agreement within the uncertainty range.

  • PDF

Low level tritium analysis using liquid scintillation counter (액체섬광계수기를 이용한 저준위 트리튬 분석법연구)

  • Yoon, Yoon Yeol;Cho, Soo Young;Lee, Kil Yong;Kim, Yongje
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.419-423
    • /
    • 2007
  • Environmental low level tritium analysis was studied using liquid scintillation counter(LSC) and electrolytic enrichment method. To obtain low level blank count, various counting vials were investigated. Among them, teflon coated PE vial had a lower blank count rate (1.86 cpm) and we obtained 2.01 Bq/L detection and tritium separation factor was above 20. LSC counting efficiency obtained $28.70{\pm}0.27%$ using the NIST tritium standard water sample.

Application of an Energy Sensitive CZT Detector to a DXA Type of Bone Densitometer

  • Yoon, Je-Woong;Lee, Hyung-Koo;Lee, Heung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.422-424
    • /
    • 2002
  • The accuracy of DXA(Dual Energy X-ray Absorptiometry) highly depends on the detection and separation capability of dual energy X-ray X-ray photons. In addition both of scan time and patient exposure are affected by detection efficiency. A CZT detector with a good energy resolution and high detection efficiency was evaluated for the application of bone densitometry. Its performance was compared to a photomultiplier tube with a NaI(T1) scintillator in terms of energy resolution, detection efficiency and the accuracy of bone mineral density measurement. The comparison study was performed with CZT detector and PM tube using DXA equipments(OSTEO Plus, OSTEO Prima, ISOL Technology). The energy spectrum was acquired using MCA(Multi-Channel Analyzer). The used X-ray energy ranged from 20keV to 86keV. The MCA result of the CZT detector showed a slightly sharper energy spectrum than that of NaI(T1). Detection efficiency of the CZT detector at 59.5keV was 1.4 times better. Remarkably the final results of bone mineral density measurements demonstrate only less than 1% difference. The CZT detector appears to have many benefits for the application of bone densitometry. Its excellent energy resolution can enhance the counting accuracy of dual energy X-ray spectrum. Furthermore its compactness in physical dimension and no cooling requirement will be additional benefits for a more compact and accurate bone densitometer.

  • PDF

Monitoring and restoration plan after construction of Wildlife Corridor at Mt. Galmachi of Sungnam City (성남시 갈마치 지역의 야생동물이동통로 복원계획 및 조성 후 모니터링)

  • Chun, Seung-Hoon;Lee, Sang-Don;Chae, Soo-Kwon
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.907-914
    • /
    • 2011
  • This study aims at monitoring the efficiency of wildlife corridor in the city of Sungnam, Gyunggi Province. During 2008-2010 for 13 months the CCTV in the city office followed number and population density using the wildlife corridor. Based on the monitoring Korean raccoon dog(Nyctereutes procyonoides) and water deer(Hydropotes inermis), Korean hare(Lepus coreanus), Korean yellow-weasel(Mustela sibirica), Korean squirrels(Sciurus vulgaris) used most often and counting 884 individuals.. This counts over 73% of targeted species and also verifies the project objectives. In future the monitoring should be increased and identify behavioral patterns focusing on ecological networks of previously fragmented habitats.