• 제목/요약/키워드: Counting efficiency

검색결과 148건 처리시간 0.027초

암모니아산화세균의 계수를 위한 영상분리기법 (A Segmentation Method for Counting Ammonia-oxidizing Bacteria)

  • 김학경;이선희;이명숙;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.287-287
    • /
    • 2000
  • As a method to control the bacteria number in adequate level, a real time control system based on microscope image processing measurement for the bacteria is adopted. For the experiment, Ammonia-oxidizing bacteria such as Acinetobacter sp. are used. This paper proposed hybrid method combined watershed algorithm with adaptive automatic thresholding method to enhance segmentation efficiency of overlapped image. Experiments was done to show the effectiveness of the proposed method compared to traditional Otsu's method, Otsu's method with adaptive automatic thresholding method and human visual method.

  • PDF

다결정 CdTe 기반의 광계수형 X선 센서 제작 및 특성평가 (The Fabrication and Property Evaluation of Poly-crystalline CdTe based Photon Counting X-ray Sensor)

  • 강상식;박지군
    • 한국방사선학회논문지
    • /
    • 제9권7호
    • /
    • pp.439-443
    • /
    • 2015
  • 종래의 방사선 의료영상 센서는 방사선에 의해 생성된 전하신호를 화소내에서 적분하는 방식이다. 본 연구에서는 저선량에서 우수한 해상력이 가능한 광계수형 영상센서를 개발하기 위해 진공 열증착법을 이용하여 다결정 CdTe(p-CdTe) 필름을 제작하였다. 또한, 광계수형 센서의 성능평가를 위하여 물리적 특성(SEM, XRD) 및 전기적 특성(leakage current, x-ray sensitivity, SNR) 평가를 하였다. 측정 결과, $1V/{\mu}m$ 이하의 인가전압에서 $5nA/cm^2$ 이하의 누설 전류밀도를 보였으며, X선 발생신호량은 $7{\mu}C/cm^2{\cdot}R$으로 광계수형 센서로의 적용에 적합한 것으로 평가되었다. 또한, 신호대잡음비는 동작영역에서 5000 이상의 값을 보였다.

대기 에어로졸 측정용 3단 임팩터의 설계 및 성능평가 (Design and Performance Evaluation of a Three Stage Impactor)

  • 지준호;배귀남;황정호
    • 한국대기환경학회지
    • /
    • 제17권6호
    • /
    • pp.441-450
    • /
    • 2001
  • A three stage impactor with the cutoff diameters of 1, 2.5, and 10$\mu\textrm{m}$ in aerodynamic diameter was developed and tested. The gravimetric method and the particle counting method were utilized to evaluate the collection performance of each stage. A vibrating orifice aerosol generator was employed to generate monodisperse test aerosols larger that 2$\mu\textrm{m}$ in diameter. Polystyrene latex (PSL) particles smaller than 2$\mu\textrm{m}$ in diameter were generated by an atomizer and the particle number concentration was measured by an Aerodynamic Particle Sizer Spectrometer. The experimental cutoff diameters obtained from the particle collection efficiency curves are in good agreement with the designed values. The square roots of Stokes number at 50% collection efficiency for stage 1, 2, and 3 are 0.42, 0.48, and 0.45, respectively. Effects of the particle bounce and the impaction plate on the collection efficiency were investigated. The collection efficiency curves including effect of the particle bounce were also compared with those of the MOUDI cascade impactor.

  • PDF

디스플레이 표집과 시각타성에 관한 연구 (A Study of Display Sampling and Visual Momentum)

  • 양리가
    • 디자인학연구
    • /
    • 제20권3호
    • /
    • pp.39-48
    • /
    • 2007
  • 본 논문은 도시환경의 공공사인시스템의 효율극대화를 위하여 안구운동을 측정하는 공학 심리적 또는 인지 과학적 실험을 통하여 안구운동과 가로세로의 시각흐름 그리고 유전된 문화적. 선험적 도식 그리고 대뇌의 시각 시스템의 차별을 탐색하였다. 따라서 EMR 관측실험과 bitmap counting 방법을 대입함으로서 가장 효율적인 시각디자인 측정을 구할 수 있는 algorithm을 도출하였다. 본 논문에서는 과학적인 실험 Data가 인간의 $\ulcorner$Schema$\lrcorner$$\ulcorner$Sensory Qualia$\lrcorner$ 에 의해, 차별화와 시각표집(Visual Sampling)의 가변성(Momentum)이 상존함을 알게 되었다.

  • PDF

수동적 감마선분석에 의한 핵물질 농축도 측정 (Enrichment Measurement of Nuclear Materials by Passive Gamma-ray Analysis)

  • Hong, Jong-Sook;Cha, Hong-Ryul;Park, Hyoung-Nae;Lee, Byung-Doo;Park, Ho-Joon
    • Nuclear Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.233-240
    • /
    • 1991
  • 수동적 감마선분석에 의해 U-235의 농축도를 비파괴적으로 측정하였다. 측정차상이 되는 선원은 U-235의 알파붕괴시 방출되는 185.7 keV 감마선이다. 농축도 측정에 영향을 미치는 인자, 즉 시료구성, 시료용기의 두께변화에 따른 감쇠효과, 감마선의 집속 및 검출효율 등을 평가하였다. 최적계측시스템하에서 측정된 상대오차는 95%신뢰구간에서 Tag값과 비교했을 때 감손 UF$_{6}$ 실린더에 대해서는 ~8%, 감손 및 천연 $UO_2$분말에 대해서는 ~8%, ~1%로 각각 나타났다.

  • PDF

실험실 방사성핵종 오염도 측정에 있어 Fluor 함침 폴리설폰 막의 이용 (Use of Flour-Impregnated Polysulfone Membranes for Measuring Radioactive Contamination in Laboratories)

  • 한명진
    • 멤브레인
    • /
    • 제9권2호
    • /
    • pp.132-139
    • /
    • 1999
  • 무기 flour로서 방사능물질과 반응하여 섬광을 일으키는 cerium activated ytrium silicate를 폴리설폰 고분자 구조내에 함침시킨 측정막을 제조하고, 이를 이용하여 방사성핵종인 $^3H$-cortisol 으로 오염된 실험실 바닥의 방사능 오염도를 측정하였다. 제조된 측정막을 이용하여 오염지역을 문지르고, 막에 함침된 flour와 오염지역으로부터 막으로 옮겨진 방사능 물질과의 직접 반응에 의해 나타난 섬광을 측정하여 방사성핵종의 양을 결정하였다. 유기 flour 가 용해되어 있는 섬광보조액(scintillation cocktail)의 도움을 필요로 하는 기존의 방사성핵종 측정방법에 비해, 측정막을 이용할 경우 오염도의 측정 효율을 유지하면서 전체적인 방사능 폐기물의 양산을 제어할 수 있는 효과를 거두었다. 한편, 탐지효과의 증대들 위해 시도된 디메틸포름아마이드를 이용한 측정막의 용매 처리는, 막 표면의 형상변화를 유도할 수있었으나, 방사성핵종에 대한 측정효율의 증대로는 귀결되지 않았다.

  • PDF

펄스 레이저 기반 담수용 미세 플라스틱 실시간 센서 모니터링 시스템 연구 (Study on Real Time Sensor Monitoring Systems Based on Pulsed Laser for Microplastic Detection in Tap Water)

  • 한승헌;김대근;정행윤;김선훈
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.294-298
    • /
    • 2019
  • Pulsed laser-based optical sensor monitoring systems for real time microplastic particle counting are proposed and developed in this study. To develop our real time monitoring system, we used a 450 nm pulsed laser and a photomultiplier with very high quantum efficiency. First, we demonstrated that the microplastic particle counting system could detect standard micro bead samples of 100, 250, and $500{\mu}m$ in river water. We then performed research concerning pulsed laser-based optical spectral sensor systems for real time microplastic monitoring. Additionally, we demonstrated that the real time microplastic remote monitoring system using LoRa communications could detect microplastic in the tap water resource protection area.

Improved fast neutron detection using CNN-based pulse shape discrimination

  • Seonkwang Yoon;Chaehun Lee;Hee Seo;Ho-Dong Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.3925-3934
    • /
    • 2023
  • The importance of fast neutron detection for nuclear safeguards purposes has increased due to its potential advantages such as reasonable cost and higher precision for larger sample masses of nuclear materials. Pulse-shape discrimination (PSD) is inevitably used to discriminate neutron- and gamma-ray- induced signals from organic scintillators of very high gamma sensitivity. The light output (LO) threshold corresponding to several MeV of recoiled proton energy could be necessary to achieve fine PSD performance. However, this leads to neutron count losses and possible distortion of results obtained by neutron multiplicity counting (NMC)-based nuclear material accountancy (NMA). Moreover, conventional PSD techniques are not effective for counting of neutrons in a high-gamma-ray environment, even under a sufficiently high LO threshold. In the present work, PSD performance (figure-of-merit, FOM) according to LO bands was confirmed using a conventional charge comparison method (CCM) and compared with results obtained by convolution neural network (CNN)-based PSD algorithms. Also, it was attempted, for the first time ever, to reject fake neutron signals from distorted PSD regions where neutron-induced signals are normally detected. The overall results indicated that higher neutron detection efficiency with better accuracy could be achieved via CNN-based PSD algorithms.

젖소의 Staphylococcus aureus성 유방염에 대한 liposomal cephalexin 의 건유기 치료효과 (The effect of liposomal cephalexin on the dry period treatment of bovine Staphylococcus aureus mastitis)

  • 신진호;한홍률
    • 대한수의학회지
    • /
    • 제32권2호
    • /
    • pp.251-258
    • /
    • 1992
  • Stable plurilamellar vesicle(SPLV) 제작법을 이용한 liposomal cephalexin으로 젖소의 Staphylococcus aureus성 유방염에 대해 건유기 치료를 시도하였다. SPLV의 모양과 크기를 transmission electron microscopy로 관찰하였으며 SPLV의 포획율 및 안정성은 high performance liquid chromatography 및 liquid scintillation counting으로 조사한 바 SPLV의 크기는 대개 직경 $0.1{\sim}4.0{\mu}m$였고, cephalexin 포획율은 $25.8{\pm}3.1$ $(mean{\pm}SE)$였으며 $4^{\circ}C$ 보관시 0, 24, 48, 72 및 96 시간후의 유리농도백분율은 각각 1.1, 3.9, 6.5, 7.5 및 8.4%였다. S aureus에 감염된 45분방에 대하여 15분방씩 3군으로 나누어 각 분방당 250mg의 liposomal cephalexin(LC군), 250mg free cephalexin(FC)군 및 blank liposome을 첨가한 250mg cephalexin(BLC)군을 건유시 분방내 주입한 후 분만당일에 균분리 및 동정을 실시한 바 LC군, FC군 및 BLC군에서 각각 1, 8 및 7분방에서 상기와 동일한 균이 분리되어 LC군이 타군에 비해 유의한 치료효과를 나타내었다.

  • PDF

액체섬광계수기를 이용한 지하수 내 우라늄 동위원소 측정법에 관한 연구 (A study of activity ratios of uranium isotope in the groundwater using liquid scintillation counter)

  • 조수영;송경선;이길용;윤윤열;김원백;고경석
    • 분석과학
    • /
    • 제25권2호
    • /
    • pp.146-151
    • /
    • 2012
  • 액체섬광계수기를 이용한 지하수 내 우라늄 동위원소의 최적 측정방법에 대한 연구를 수행하였다. 용매추출법을 이용해 우라늄을 추출하였고, 시료량과 pH에 따른 추출효율을 조사하였다. 우라늄 추출효율에 미치는 영향을 조사하기 위해 표준용액을 사용하여 100 mL~1 L 범위에서 시료량을 변화 시켰으며 pH는 0.5~10 범위에서 측정하였다. 실험결과 우라늄의 추출효율은 pH에 매우 민감한 것으로 나타났으며 pH 2 에서 최고치를 나타냈다. 이에 반해 시료량은 추출효율에 큰 영향을 미치지 않는 것으로 나타났다. 우라늄 표준시료를 이용한 실험 결과 추출효율은 $95.93{\pm}0.77%$ 이었고, 계측시간 5시간을 기준으로 한 우라늄의 검출한계는 0.018 Bq/L 이었다. 본 연구결과로부터 지하수에 함유된 우라늄의 최적추출 및 측정법을 확립할 수 있었고 본 방법의 검증을 위해서 지하수 중 우라늄의 분석에 일반적으로 사용되는 ICP-MS 측정결과와의 비교분석도 함께 수행하였다. 본 연구에서 개발된 분석법을 대전 주변 지역 네 곳의 지하수를 대상으로 우라늄 함량 및 동위원소 비의 측정에 적용한 결과 우라늄의 농도는 0.59~6.69 Bq/L 그리고 $^{234}U/^{238}U$의 방사성 비는 0.88~1.40 범위로 나타내었다.