• Title/Summary/Keyword: Counter-flow cooling tower

Search Result 15, Processing Time 0.028 seconds

Program Development for Design of Counter-flow Cooling Tower (향류형 냉각탑의 기본설계 프로그램 개발)

  • Ko, Kwang-Ho;In, Jong-Soo;Oh, Tae-Il
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.4
    • /
    • pp.383-389
    • /
    • 2004
  • This paper is to develop the program for sizing of a counter-flow cooling tower. Air flow, air exit tmperature, fan power are calculated from design coditions of cooling tower by using this program. The basic equations and solutions of the heat transfer and pressure drop of cooling tower are descrived and the algorithm development for design of cooling tower is performed. The variation of fan power of cooling tower in acoording to variation of cell area and fill height is performed by using this program. This result shows that the optimal design for install and running cost of cooling tower can be performed by using this program.

  • PDF

Effect of Filler on the Flow of Counter Flow Type Cooling Tower (충진재(Filler)가 대향류형(Counter Flow Type) 냉각탑 유동에 미치는 영향에 대한 연구)

  • Shin, Jeong-Hoon;Lee, Jun-Kyoung;Jin, Cheol-Gyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.565-572
    • /
    • 2022
  • The white plume from the cooling tower can be generated by mixing between discharging hot and humid air and cold air outside. This causes various problems such as icing, traffic disturbances, and fire factors in the vicinity, moreover it can also damage the image of a company. Various methods can be used to prevent white plume, one of them is to install a heat exchanger at the outlet of the cooling tower so that the heat exchanger transfers as much heat as possible to lower the temperature. Therefore the air flow path in the cooling tower should be optimized. Installation of the filler can be used to make the air flow better, thus we investigate the effect of filler on the air flow using CFD method. The pressure and velocity profile in the cooling tower could be acquired by the calculations. The filler made the velocity of the air entering the heat exchanger uniform this was because high flow resistance of the filler suppresses the generation of eddy in the cooling tower. But the total air pressure drop increased about 2 times with filler because the pressure drop by the filler accounted for about 60% of the total pressure drop.

A study on the counter-flow cooling tower performance analysis using NTU-method (NTU법을 이용한 대향류형 냉각탑의 성능해석에 관한 연구)

  • 김영수;서무교;이상경
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.598-604
    • /
    • 1999
  • The thermal performance of cooling towers is affected by the temperature of inlet water, wet bulb temperature of entering air add water-air flow rate. In this study, the effects of these variables are simulated using NTU-method and experimentally investigated for the counter-flow cooling towers. The simulation program to evaluate these variables which affect the performance of cooling tower was developed. The maximum errors between the results of simulations and experiments were 3.8% under the standard design conditions and 5.4% under the other conditions. The performance was increased up to 46~50% as the water loading was increased from $6.8m^3$/$hr\cdot m^2$ to $15.9m^3$/$hr\cdot m^2$. The range was reduced up to 56~42% when the wet bulb temperature of the entering air was increased from $22^{\circ}C\; to\; 29^{\circ}C.$

  • PDF

The Experimental Study of the Hybrid Cooling Tower using Cross and Counter Type Fills (직교.대향류 충진재를 이용한 하이브리드 냉각탑에 대한 실험적 연구)

  • Jun, C.H.;Lee, H.S.;Lee, H.C.;Moon, C.G.;Kim, J.D.;Kim, Eun-Pil;Yoon, J.I.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.236-237
    • /
    • 2005
  • An experimental study on the Hybrid Cooling Tower has been done having a rated capacity of 3RT. Counter flow type fill, cross flow type fill and hybrid-type fill which is combined with two type fills as previously stated having a height of 0.3m have been used in the 0.8m${\times}$0.4m${\times}$1.9m dimensional tower respectively. The heat exchanger is consisting of 2 or 3 rows. The relevant temperatures and the velocities were selected based on the typical Korean weather for the year round operation of the tower. The cooling capacity of the tower is explained with respect to varying air inlet velocities, wet-bulb temperatures, and air to cooling water volume flow rate ratio (L/G ratio). The capacity of the hybrid-type fill was much superior to other fills, but hybrid-type fill shows higher pressure drop.

  • PDF

Effects of Hydrophilic Treatment by IAR Method on the Packing Characteristic Value (이온 보조 반응법에 의한 친수성 처리가 충전재 특성값에 미치는 영향)

  • Kim, Jin-Ho;Choe, Chung-Hyeon;Gang, Byeong-Ha;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.554-560
    • /
    • 2001
  • Hydrophilic treatment of the packing materials in a cooling tower has been made by the ion assisted reaction (IAR) method to increase the wettability of the packing materials. The effects of hydrophilic treatment of packing materials on the performance of a cooling tower have been investigated in a wide range of operating parameters, such as water flow rate, air flow rate, and the water inlet temperature. A pilot cooling tower has been designed and built to model a counter-flow cooling tower. The results obtained indicate that the packing characteristic value with hydrophilic packing could be substantially increased by 6∼19.3% than that with conventional packing in the operating ranges considered. The correlations of the packing characteristic value as a function of water-to-air ratio are suggested for a counter-flow cooling tower with hydrophilic packing as well as with conventional packing.

A Study on the Characteristics of Forced Draft Cooling Tower (강제통풍식 냉각탑 특성에 관한 연구)

  • Seoh, Jeong-Il;Kim, Kwang-Soo;Lee, Young-Soo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.2
    • /
    • pp.1-9
    • /
    • 1984
  • This paper presents design conditions due to the NTU of counter and cross flow type cooling tower. In the calculation of optimum design conditions for above two types which are widely used in our country, standard water-air ratio, ambient wet bulb temperature and bulk water temperature were adopted by domestic wheather conditions. The important result of this study is obtained as follows : Under the constant value of Ka and L, the number of transfer unit of cross flow type cooling tower Is about 1.1 times as large as that of counter, so the volume of cross flow type is about $10\%$ greater than that of counter.

  • PDF

A Study on The Counter-Flow Cooling Tower Performance Anaysis and Experiments

  • Seo, Moo-Gyo;Kim, Young-Soo;Kim, Eun-Pil;Yoon, Jung-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.50-57
    • /
    • 2001
  • The thermal performance of cooling towers is affected by the temperature of inlet water, wet bulb temperature of entering air and water-air flow rate. In this stud${\gamma}$, the effects of these variables are simulated using NTU-method and experimentally investigated for the counter-flow cooling towers. The simulation program to evaluate these variables which affect the performance of cooling tower was developed. The maximum errors between the results of simulations and experiments were 3.8% under the standard design conditions and 5.4% under the other conditions. The performance was increased up to 46~50% as the water loading was increased from 6.8$m^3/hr{\cdot}m^2$ to 159$m^3/hr{\cdot}m^2$. The range was reduced up to 56~42% when the wet bulb temperature of the entering air was increased from 22${\circ}C$ to 29${\circ}C$.

  • PDF

Evaluation for the Cooling Capability of Secondary Cooling Tower in HANARO (하나로 2차 냉각탑의 냉각능력 평가)

  • Park, Yong-Chul;Wu, Jong-Sup;Cho, Yeong-Gurb;Ryu, Jeong-Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.345-350
    • /
    • 2000
  • The heat produced by the fission in the fuel of HANARO, 30 MW research reactor, is transferred from the primary cooling water to the secondary cooling water through heat exchangers, and the heat absorbed by the secondary cooling water is released into the atmosphere by the 33 MW cooling tower which is a mechanical induced draft and counter flow type. If the outlet temperature of cooling tower exceeds 33 of due to the loss of the cooling tower performance under reactor operation above $50\%$ of the full power, the reactor power should be reduced to half of the full power for safe operation. Therefore, the cooling capability of cooling tower should be maintained for the reactor to be normally operated. To predict the capability of cooling tower for full power reactor operation of 30 MW, the performance test of cooling tower was done at the reactor present power of 24 MW and the capability was respectively evaluated by characteristics and performance curves methods in accordance with the Code of Cooling Tower Institute of U.S.A. to confirm the reliability of evaluation. As a result, it was confirmed, through the results of each evaluation, that the cooling capability of cooling tower meets the design required heat load. Also, the equations of the performance and the characteristics curves of the cooling tower, based on the collected data during this performance test, was obtained for developing the calculation program to predict the cooling capability during reactor operation.

  • PDF

Experimental study on the thermal performance of a cooling tower (냉각탑 열성능 특성의 실험적 연구)

  • 이한춘;방광현;김무환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.88-94
    • /
    • 1998
  • The thermal performance of cooling towers is affected mainly by the velocity, temperature and humidity of the entering air, In this paper, the effects of these variables are experimentally investigated for both counter-flow and cross-flow cooling towers. The cooling performance is reduced by up to 50% as the relative humidity of the entering air is increased from 40% to 80%. The higher air velocity and lower coolant flow show better cooling performance. The coolant loss rates in the present experimental conditions are in the range of 0.4 to 1.7%

  • PDF

Experimental Study on Heat and Mass transfer Coefficient Comparison Between Counterflow Types and Parallel in Packed Tower of Dehumidification System

  • Sukmaji, I.C.;Choi, K.H.;Yohana, Eflita;Hengki R, R.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.162-169
    • /
    • 2009
  • In summer electrical energy is consumed in very high rate. It is used to operate conventional air conditioning system. Hot and humid air can germinate mould spores, encourage ill health, and create physiological stress (discomfort). Dehumidifier solar cooling effect is the one alternative solution saving electrical energy. We use surplus heat energy in the summer, to get cooling effect and then to get human reach to comfort condition. These devices have two system, dehumidifier and regeneration system. This paper will be focus in dehumidifier system. Dehumidifier system use for absorbing moisture in the air and decreasing air temperature. When the liquid desiccant as strong solution contact with the vapor air in the packed tower, it works. The heat and mass transfer performances of flow pattern in the packed tower of dehumidifier are analyzed and compared in detail. In this experiment was introduced, the flow patterns are parallel flow and counter flow. The performance of these flow patterns will calculate from air side. Which is the best flow pattern that gave huge mass transfer rate? The proposed dehumidifier flow pattern will be helpful in the design and optimization of the dehumidifier solar cooling system.

  • PDF