• Title/Summary/Keyword: Counter-Flow

Search Result 492, Processing Time 0.027 seconds

NAVIER-STOKES SIMULATION OF A MICRO-VISCOUS PUMP (초소형 점성 펌프의 Wavier-Stokes 해석)

  • Kang, D.J.
    • Journal of computational fluids engineering
    • /
    • v.11 no.4 s.35
    • /
    • pp.75-80
    • /
    • 2006
  • Navier-Stokes simulation of the flow in a micro viscous pump is carried out. The micro viscous pump consists of a rotating circular rotor placed in a two dimensional channel. All simulation is carried out by using a finite volume approach, at the Reynolds number of 0.5, to study the performance of the micro viscous pump. Length of channel of the pump is varied to simulate the effects of the pumping load. Numerical solutions show that the net flow of the pump is realized by two counter rotating vortices formed on both sides of the rotor. The volume flow rate of the pump is decreased as length of the channel is increased, while the static pressure difference across the rotor is increased. The static pressure difference across the rotor is observed to be inversely proportional to the volume flow rate as inertia effects are negligibly small. The efficiency of the pump is found to reach a maximum when two counter rotating vortices on both sides of the rotor becomes to merge forming an outer enveloping vortex.

Development of a Hybrid/Dual Swirl Jet Combustor for a Micro-Gas Turbine (Part I: Experimental Study on Geometric Optimization) (마이크로 가스터빈을 위한 하이브리드/이중 선회제트 연소기의 개발 (Part I: 형상 최적화를 위한 실험적 연구))

  • Park, Tae-Joon;Hwang, Cheol-Hong;Lee, Kee-Man
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.199-200
    • /
    • 2012
  • An experimental study on geometric optimization was conducted to develop a hybrid/dual swirl jet combustor for a micro-gas turbine. A hybrid concept indicating a combination of swirling jet partially premixed and premixed flames were adopted to achieve high flame stability as well as clean combustion. Location of pilot nozzle, angle and direction of swirl vane were varied as main parameters with a constant fuel flow rate for each nozzle. The results showed that the variation in location of pilot nozzle resulted in significant change in swirl intensity due to the change in flow area near burner exit, and thus, optimized nozzle location was determined on the basis of CO and NOx emissions under conditions of co-swirl flow and swirl $angle=30^{\circ}$. The increase in swirl angle (from $30^{\circ}$ to $45^{\circ}$) enhanced the emission performances, in particular, with a significant reduction of CO emission near lean-flammability limit. It was observed that the CO emission near lean-flammability limit was further reduced through the counter-swirl flow. However, there was not significant change in the NOx emission in the operating conditions (i.e. equivalence ratio of 0.6~0.7) between the co- and the counter-swirl flow.

  • PDF

Counter-Rotating Streamwise Vortex Formation in the Turbine Cascade with Endwall Fence

  • Koh Seong Ryong;Moon Young J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.155-161
    • /
    • 1999
  • The three-dimensional turbulent cascade flows with and without endwall fences are numerically investigated by solving the incompressible Navier-Stokes equations with a high-Reynolds number $k-{\varepsilon}$ turbulence closure model. A projection method based algorithm is used in the finite-volume formulation, with the second order upwind-differencing scheme for the convective terms. First, assessments on accuracy of the present method are made by comparing the static pressure distributions at the mid-span of the cascade with measured data, and also by confirming the experimental observations on the choice of an optimal fence height for the secondary flow control. In understanding the three-dimensional nature of the secondary flow in turbine cascade, the limiting streamline patterns and the static pressure contours at the suction surface of the blade as well as on the cascade endwall are employed to visualize the effectiveness of the endwall fence for the secondary flow control. Analysis on the streamwise vorticity contour maps along the cascade with the three-dimensional representation of their iso-surfaces reveals the strucuture of the complicated vortical flow in the turbine cascade with endwall fence, and also leads to an understanding on formation of the counter-rotating streamwise vortex over the endwall fence, in explaining the mechanisms of controlling the secondary flow and also for the proper selection of an optimal fence height.

  • PDF

PERFORMANCE CHARACTERISTICS OF A PROTON EXCHANGE MEMBRANE FUEL CELL(PEMFC) WITH AN INTERDIGITATED FLOW CHANNEL

  • Lee, P.H.;Cho, S.A.;Han, S.S.;Hwang, S.S.
    • International Journal of Automotive Technology
    • /
    • v.8 no.6
    • /
    • pp.761-769
    • /
    • 2007
  • The configuration of the flow channel on a bipolar plate of a proton exchange membrane fuel cell(PEMFC) for efficient reactant supply has great influence on the performance of the fuel cell. Recent demand for higher energy density fuel cells requires an increase in current density at mid voltage range and a decrease in concentration overvoltage at high current density. Therefore, an interdigitated flow channel where mass transfer rate by convection through a gas diffusion layer is greater than the mass transfer by a diffusion mechanism through a gas diffusion layer was recently proposed. This study attempts to analyze the i-V performance, mass transfer and pressure drop in interdigitated flow channels by developing a fully three dimensional simulation model for PEMFC that can deal with anode and cathode flow together. The results indicate that the trade off between performance and pressure loss should be considered for efficient design of flow channels. Although the performance of the fuel cell with interdigitated flow is better than that with conventional flow channels due to a strong mass transfer rate by convection across a gas diffusion layer, there is also an increase in friction due to the strong convection through the porous diffusion layer accompanied by a larger pressure drop along the flow channel. It was evident that the proper selection of the ratio of channel and rib width under counter flow conditions in the fuel cell with interdigitated flow are necessary to optimize the interdigitated flow field design.

A Closed Counter-Current Two-Phase Thermosyphon Loop of a Cold Neutron Source in HANARO Research Reactor (하나로 원자로에 설치될 대향 이상 열사이펀 루프에 관한 실험)

  • Hwang, Kwon-Sang;Cho, Man-Soon;Sung, Hyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.8
    • /
    • pp.1038-1045
    • /
    • 2000
  • An experimental study was carried out to delineate the flow characteristics in a closed countescurrent two-phase thermo syphon with concentric tubes. This is to be installed in the HANARO research reactor as a part of a Cold Neutron Source(CNS). In the present investigation, experiments ata room temperature with Freon-II3 as a moderator were performed. Results show that, based on the magnitude of pressure fluctuation, the flow regimes could be divided into 4 distinct ones in the ($V_f,\;Q_i$) plane, where $V_f$ represents the volume of the charged liquid and $Q_i$ the heat load: a stable flow regime, an oscillatory flow regime, a restablized flow regime and a dryout flow regime. For $V_f$>2.5l, the flow is stable at low $Q_i$. However, as $Q_i$ increases, the flow becomes oscillatory and finally restablizes As $V_f$ increases, the oscillation amplitude decreases, reaching to the restablized flow region at low $Q_i$, and the liquid level in the moderator cell remains high. In the oscillatory flow regimes, for a fixed VI; the oscillating period of time varies with $Q_i$, having a minimum value at a certain value of $Q_i$. The heat load, where the oscillating period of time is minimum, decreases as $V_f$ increases.

Counter anion effects in anion exchange membrane-fabricated non-aqueous vanadium redox flow battery

  • Son, Pyeong Soo;Oh, Min-Seok;Ye, Jun-Hee;Choi, Seong-Ho
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.341-346
    • /
    • 2015
  • In order to understand the counter anionic effects in a non-aqueous vanadium redox flow battery (VRFB), we synthesized four types of electrolyte salts (1-ethyltriethamine tertafluoroborate, [E-TEDA]+[BF4], 1-ethyltriethamine hexafluorophosphate, [E-TEDA]+[PF6], 1-butyltriethylamine tertafluoroborate, [B-TEDA]+[BF4], and 1-buthyltriethamine hexafluorophosphate [B-TEDA]+[PF6]) by counter anion exchange reaction after the SN2 reaction. We confirmed the successful synthesis of the electrolyte salts [E-TEDA]+[Br] and [B-TEDA]+[Br] via 1H-NMR spectroscopy and GC-mass analysis before the counter anion exchange reaction. The electric potential of the vanadium acetylacetonate, V(acac)3, as an energy storage chemical was shown to be 2.2 V in the acetonitrile solvent with each of the [E-TEDA]+[BF4], [E-TEDA]+[PF6], [B-TEDA]+[BF4], and [B-TEDA]+[PF6] electrolyte salts. In a non-aqueous VRFB with a commercial Neosepta AFN membrane, the maximum voltages reached 1.0 V and 1.5 V under a fixed current value of 0.1 mA in acetonitrile with the [E-TEDA]+[BF4] and [E-TEDA]+[PF6] electrolyte salts, respectively. The maximum voltage was 0.8 V and 1.1 V under a fixed current value of 0.1 mA in acetonitrile with the [B-TEDA]+[BF4] and [B-TEDA]+[PF6] electrolyte salts, respectively. From these results, we concluded that in the non-aqueous VRFB more of the [PF6] counter anion than the [BF4] counter anion was transported onto the commercial Neosepta AFN anion exchange membrane.

A Study on Dynamic Characteristics of Hydraulic Motor Brake System with Counter Balance Valve (카운터 밸런스 밸브를 내장한 유압 모터 브레이크 시스템의 동특성)

  • Yun, So-Nam;Lee, Ill-Yeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.29 no.3
    • /
    • pp.214-219
    • /
    • 1993
  • Counter balance valve is used as one part of hydraulic motor brake system. The function of this valve is to protect over-run or free falling of inertia load. But occasionally the brake system with counter balance valve makes some undesirable problems such as pressure surges or vibrations. These problems may hurt system safety and driver's conformability. Nevertheless, studies on dynamic characteristics of hydraulic system including counter balance valve are very rare, so further accumulation of research results are required. In this study, for the purpose of easy estimation about dynamic characteristics of hydraulic system including counter balance valve, precise formulation describing fluid dynamics and valve dynamics under various boundary conditions were made. The equations obtained in the preceding process include some parameters that must be got experimentally. Flow coefficients of valve and choke are the most significant ones among the parameters. So these parameters are obtained experimentally in this study, and experimental equations obtained from the experimental data were used for numerical calculation. The equations were analysed by numerical integration using Runge-Kutta method, because the equations contain various nonlinear terms. From the numerical analysis, it was verified that the dynamic response of counter balance valve and pressure variation at each elements can be estimated very easily. So the analysing method developed in this study enabled very easy estimating the relation between the performances of counter balance valve and various physical parameters related to the valve. Conclusively, it is said that the results obtained in this study can be used very usefully to develop a new type counter balance valve or to apply the valve to actual hydraulic system for various industrial equipments.

  • PDF

Case Study for Efficiency of Counter-Debrisflow Structures in Baekyang Mt. (토석류 방재구조물 성능 검토 수치해석 - Case study: 부산 백양산)

  • Jeong, Seokil;Song, Chag Geun;Kim, Hong Taek;Lee, Seung Oh
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.84-89
    • /
    • 2018
  • The number of landslides has increased since the 2000s due to the increased frequency of heavy rainfall caused by abnormal weather. A variety of debris flow prevention facilities have been installed as a countermeasure against this problem. However, it is not easy to evaluate the efficiency of debris flow prevention structures except for the structures with constant volume such as the erosion dam, because the other structures are limited to be reproduced in simulation program for debris flow. Therefore, the methods by which the debris flow prevention structures were modeled were proposed, and the efficiency of four prevention structures installed in Baekyang Mt. in Busan was evaluated with UDS, which accuracy had been verified, using these methods. The initial amount of debris flow was determined based on landslide which occurred in 2014, and specifications of the complex retaining walls around the settlements were measured and applied modeling for terrain. The numerical results showed that the efficiency of debris flow prevention structures could be quantitatively presented. Among the debris flow prevention structures installed in Baekyang Mt., prevention structure of barrier type for debris flow was the most efficiency and debris flow prevention device was the lowest efficiency when the only depth of debris was evaluated. It seems that this study is meaningful to propose the methods which were used to model the debris flow prevention structures that could not be reproduced in most 2D debris flow numerical analysis programs. If precise verification of the presented methods is carried out, it will be possible to provide clear criteria for the efficiency evaluation method of disaster prevention structures.

A Study of Performance estimate and Flow Analysis of the 100kW Counter-Rotating Marine Current Turbine by CFD

  • Kim, Mun-Oh;Kim, Chang-Goo;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.166.1-166.1
    • /
    • 2011
  • The rotor design is fundamental to the performance and dynamic response of the Counter-rotating marine tidal current turbine. The wind industry has seen significant advancement single rotor blade technology, offering considerable knowledge and making it easy to transfer to tidal stream energy converters. In this paper, 3D flow and performance an alysis on a 100 kW counter-rotating marine current turbine blade was carried out by using the 3-D Navier-Stokes commercial solver(ANSYS CFX-11.0) to provide more efficient design techniques to design engineers. The front and rear rotor diameter is 8m and the rotating speed is 24.72rpm. Hexahedral meshing was generated by ICEM-CFD to achieve better quality of results. The rated power and its approaching stream velocity for design are 100 kW and 2 m/s respectively. The pressure distribution on the blade's suction side tells us that the pressure becomes low at the leading edge of the airfoil as it moves from the hub to the tip.

  • PDF

Analysis of the Salt Separation and Concentration Using Counter-current Reverse Osmosis Spiral Wound Module (향류식 역삼투 나권형 모듈을 이용한 염분리농축 특성 해석)

  • 조한욱;민병렬;최광호
    • Membrane Journal
    • /
    • v.4 no.3
    • /
    • pp.142-151
    • /
    • 1994
  • Counter-current type reverse osmosis spiral wound module was manufactured for the separation and concentration of salf solution. The ratio of permeate volumetric flow rate vs. brine volumetric flow rate was effective parameter between rejection and degree of cocentration. The reflection coefficient was correspondent to the relation between rejection and degree of cocentration by Spiegler-Kedem model. Counter-current reverse osmosis process had more osmotic pressure drop effect and more degree of concentration than general reverse osmosis process. As a result of computer calculation, the extension of module length than module diameter was more effective for the increase of degree of concentration.

  • PDF