• 제목/요약/키워드: Counter Force

검색결과 169건 처리시간 0.037초

모빌리티 측정을 통한 하드디스크의 Unbalance 검출 및 보정방법 (Measurement Method of HDD Absolute Unbalance Magnitude and Position by measuring the Mobility)

  • Choe Hyeon;Kim In Ung;Lee Jae Won;Jeong Yong Gu;Choe Jeong Heon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.340.1-340
    • /
    • 2002
  • The unbalance exciting force induced by HDD of lately getting higher speed is directly influenced by the rotational speed and the mechanical assembly allowance between disk and spindle motor, and which gives rise to the structure borne noise of the personal computer. The absolute unbalance mass of HDD needs to be measured and adjusted by the counter mass to control the unbalance exciting force effectively in the stage of assembling the disk and spindle motor. This study introduces the measurement methods of the magnitude of the absolute unbalance mass and the position of HDD by 2 accelerometers. The absolute unbalance mass can be obtained by the acceleration responses and the mobility of the mechanical part, while the position of the unbalance mass can e obtained by the rotation acceleration orbit.

  • PDF

Wear Characteristics of Atomic Force Microscope Tip

  • Chung, Koo-Hyun;Kim, Dae-Eun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권2호
    • /
    • pp.39-45
    • /
    • 2004
  • Atomic Force Microscope (AFM) has been widely used in micro/nano-scale studies and applications for the last few decades. In this work, wear characteristics of silicon-based AFM tip was investigated. AFM tip shape was observed using a high resolution SEM and the wear coefficient was approximately calculated based on Archard's wear equation. It was shown that the wear coefficient of Si and ${Si}_3$$N_4$ tips were in the range of ${10}^{-1}$~${10}^{-3}$and ${10}^{-3}$~${10}^{-4}$, respectively. Also, the effect of relative humidity and sliding distance on adhesion-induced tip wear was investigated. It was found that the tip wear has more severe for harder counter surface materials. Finally, the probable wear mechanism was analyzed from the adhesive and abrasive interaction point of view.

전자기 액츄에이터를 이용한 진동제어시스템 (A Design of Active Vibration Control System Using Electromagnetic Actuators)

  • 이주훈;전정우;미티카 카라이아니;강동식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.936-939
    • /
    • 2006
  • The pneumatic isolator is widely adopted for anti-vibration of precision measuring and manufacturing equipments. But, when the precision demand on anti-vibration is extreme or the load is moving, the performance of anti-vibration can not meet satisfaction. In these cases, as a complementary, active vibration suppression system can be added for advanced performance. In this paper, an active control system is presented, which uses electromagnetic actuators for vibration suppression. The anti-vibration characteristic of pneumatic isolator is analyzed for system modeling and actuator specifying. The modeling and the 3D dynamic simulation is performed for control system design. For the electromagnetic actuator design, the magnetic flex density and the current-force characteristic analysis are achieved.

  • PDF

Biomimetic control for redundant and high degree of freedom limb systems: neurobiological modularity

  • Giszter, Simon F.;Hart, Corey B.
    • Smart Structures and Systems
    • /
    • 제7권3호
    • /
    • pp.169-184
    • /
    • 2011
  • We review the current understanding of modularity in biological motor control and its forms, and then relate this modularity to proposed modular control structures for biomimetic robots. We note the features that are different between the robotic and the biological 'designs' with features which have evolved by natural selection, and note those aspects of biology which may be counter-intuitive or unique to the biological controls as we currently understand them. Biological modularity can be divided into kinematic modularity comprised of strokes and cycles: primitives approximating a range of optimization criteria, and execution modularity comprised of kinetic motor primitives: muscle synergies recruited by premotor drives which are most often pulsatile, and which have the biomechanical effect of instantiating a visco-elastic force-field in the limb. The relations of these identified biological elements to kinematic and force-level motor primitives employed in robot control formulations are discussed.

전도성 폴리아닐린(Polyaniline)을 이용한 전기작동 종이(EAPap)의 굽힘변형 개선 (Bending Displace Improvement of Electro-active Paper Using Conductive Polyaniline Coating)

  • 김주형;윤성률;김재환
    • 한국소음진동공학회논문집
    • /
    • 제18권12호
    • /
    • pp.1310-1316
    • /
    • 2008
  • Bi-layer and tri-layer structures of electro-active paper(EAPap) using conductive polyaniline(PANI) coating were investigated to improve bending displacement of cellulose EAPap. Two different counter ions, perchlorate($CIO_4^-$) and tetrafluoroborate($BF_4^-$), are used as dopant ions in the PANI processing. The actuation performances of hi-layer and tri-layer structure are evaluated in terms of tip displacement, blocked force, strain energy density and power output density. The actuation performance of the tri-layer actuator was better than the hi-layer structure, and the maximum displacement and blocked force of tri-layer $CIO_4^-$ doped-PANI-EAPap were 13.2 mm and 0.15 mN, respectively. Also the power output of the actuator is similar to the required power of biological muscle application.

Test and Simulation of an Active Vibration Control System for Helicopter Applications

  • Kim, Do-Hyung;Kim, Tae-Joo;Jung, Se-Un;Kwak, Dong-Il
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제17권3호
    • /
    • pp.442-453
    • /
    • 2016
  • A significant source of vibration in helicopters is the main rotor system, and it is a technical challenge to reduce the vibration in order to ensure the comfort of crew and passengers. Several types of passive devices have been applied to conventional helicopters in order to reduce the vibration. In recent years, helicopter manufacturers have increasingly adopted active vibration control systems (AVCSs) due to their superior performance with lower weight compared with passive devices. AVCSs can also maintain their performance over aircraft configuration and flight condition changes. As part of the development of AVCS software for light civil helicopter (LCH) applications, a test bench is constructed and vibration control tests and simulations are performed in this study. The test bench, which represents the airframe, is excited using a pair of counter rotating force generators (CRFGs) and a multiple input single output (MISO) AVCS that consists of three accelerometer sensors and a pair of CRFGs; a filtered-x least mean square (LMS) algorithm is applied for the vibration reduction. First, the vibration control tests are performed with uniform sensor weights; then, the change in the control performance according to changes in the sensor weight is investigated and compared with the simulation results. It is found that the vibration control performance can be tuned through adjusting the weights of the three sensors, even if only one actuator is used.

실습선 한바다호의 강풍시 항내 어프로칭 조선 및 예인선 사용 기준에 관한 연구 (Ship's Maneuverability & Required Number of Tug Boat in Strong Winds for the T.S. HANBADA)

  • 정창현;공길영;이윤석
    • 한국항해항만학회지
    • /
    • 제32권8호
    • /
    • pp.597-602
    • /
    • 2008
  • 실습선 한바다호는 수면 상부의 구조물이 상대적으로 큰 선형으로 풍압력의 영향을 크게 받아 압류나 회두와 같은 현상이 비교적 크게 나타나고, 특히 접이안 또는 항내에서 저속으로 운항할 경우 이러한 외력의 영향이 현저하게 작용한다. 본 논문에서는 파도가 충분히 발달되지 않은 항내 조선을 전제로 한바다호의 풍압력과 풍압모우멘트를 산출하여 상대 풍향과 풍속에 따른 표류각과 대응 타각을 분석하였다. 또한, 실습선 한바다호의 접이안시 예인선의 소요마력 결정을 선체에 작용하는 풍압력을 기초로 산출하였고, Bow Thruster를 이용한 접이안 가능 최대 풍속을 제시하였다. 연구 결과는 풍압력이 크게 작용하는 대형선의 항내조선과 예인선 운용에 큰 도움이 될 것으로 판단된다.

폴리아닐린이 코팅된 Electro-Active Paper 작동기 성능평가 (Performance Characterization of Polyaniline Coated Electro-Active Paper Actuator)

  • 고현우;문성철;적림동;김기백;김재환
    • 한국정밀공학회지
    • /
    • 제30권6호
    • /
    • pp.658-664
    • /
    • 2013
  • Bending actuators composed of cellulose with an electrically conducting polymer (CP) are fabricated and their performance is characterized in the air. Two different counter ions, perchlorate and tetrafluoroborate are used as dopant ions in the polyaniline CP processing. CP-cellulose-CP trilayer and CP-cellulose bilayer samples are fabricated with different dopant ions, and their actuation performance is evaluated in terms of tip displacement, blocked force and electrical power consumption along with the humidity level and actuation frequency. The trilayer samples substantially enhanced the tip displacement compared to the bilayer ones. The actuation performance of the trilayer actuator is three times better than that of original cellulose electro-active paper (EAPap) actuator. The displacement and blocked force of CP-EAPap actuators are dependent on the humidity and frequency.

Classification of White Blood Cell Using Adaptive Active Contour

  • Theerapattanakul, J.;Plodpai, J.;Mooyen, S.;Pintavirooj, C.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1889-1891
    • /
    • 2004
  • The differential white blood cell count plays an important role in the diagnosis of different diseases. It is a tedious task to count these classes of cell manually. An automatic counter using computer vision helps to perform this medical test rapidly and accurately. Most commercial-available automatic white blood cell analysis composed mainly 3 steps including segmentation, feature extraction and classification. In this paper we concentrate on the first step in automatic white-blood-cell analysis by proposing a segmentation scheme that utilizes a benefit of active contour. Specifically, the binary image is obtained by thresolding of the input blood smear image. The initial shape of active is then placed roughly inside the white blood cell and allowed to grow to fit the shape of individual white blood cell. The white blood cell is then separated using the extracted contour. The force that drives the active contour is the combination of gradient vector flow force and balloon force. Our purposed technique can handle very promising to separate the remaining red blood cells.

  • PDF

실생활 충격소음을 통한 표준 바닥충격원의 실효성 검증 (Verification of Effectiveness of the Standard Floor Impact Source by Comparing with Living Impact Sources)

  • 박현구;김경모;김선우
    • 한국소음진동공학회논문집
    • /
    • 제23권12호
    • /
    • pp.1117-1126
    • /
    • 2013
  • The standard impact sources, standardized to rate the sound insulation performance of floor structure, should simulate well the real floor impact sources, which is very important to grade the floor structure then to establish counter plan to improve the performance of floor. Recently the tire, the standard heavyweight impact source, has been discussed that the impact force is too big to represent the real impact force. And researches have been carried on the applicability as a substitute or a supplementary. In addition, tapping machine, the standard lightweight impact source, is also questionable if it is representative of real lightweight impact source. This study aims to examine the similarity of standard impact sources with living impact sources, comparing the physical characteristics such as impact force, frequency contents and sound level. The result showed that the physical characteristics of standard impact sounds were somewhat different with that of living impact sounds, and the standard sources couldn't be verified from this result. Later subjective evaluation should be followed to compare how the physical differences make relationship with the subjective differences.