• Title/Summary/Keyword: Count bacteria

Search Result 670, Processing Time 0.028 seconds

Comparison of Dry Medium Culture Plates for Mesophilic Aerobic Bacteria in Milk, Ice Cream, Ham, and Codfish Fillet Products

  • Park, Junghyun;Kim, Myunghee
    • Preventive Nutrition and Food Science
    • /
    • v.18 no.4
    • /
    • pp.269-272
    • /
    • 2013
  • This study was performed to compare the performance of Sanita-Kun dry medium culture plate with those of traditional culture medium and Petrifilm dry medium culture plate for the enumeration of the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet. Mesophilic aerobic bacteria were comparatively evaluated in milk, ice cream, ham, and codfish fillet using Sanita-Kun aerobic count (SAC), Petrifilm aerobic count (PAC), and traditional plate count agar (PCA) media. According to the results, all methods showed high correlations of 0.989~1.000 and no significant differences were observed for enumerating the mesophilic aerobic bacteria in the tested food products. SAC method was easier to perform and count colonies efficiently as compared to the PCA and PAC methods. Therefore, we concluded that the SAC method offers an acceptable alternative to the PCA and PAC methods for counting the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet products.

Distribution of Indicator bacteria in Spring Water in Seoul (서울시내 옹달샘물의 지표미생물 분포현황)

  • 류승희;박석기
    • Journal of Food Hygiene and Safety
    • /
    • v.17 no.2
    • /
    • pp.55-60
    • /
    • 2002
  • In order to investigate the microbiological contamination of spring water, we performed the standard plate count, coliform and psychrotrophilic bacteria in 109 spring waters in Seoul. Of 109 spring waters, geometirc mean standard plate count was 0.19 CFU/ml, and the highest in Mt. Boolam, 4..43 CFU/ml and Mt. Dobong, 3.86 CFU/ml, but not detected in Mt. Woomyun and Mt. Cheonggye. Four spring waters have shown over 100 CFU/ml in standard plate count. The geometric mean psychrotrophilic bacteria was 49.2 CFU/ml, the most prevalent spring water was Mt. Nam, 125 CFU/ml, the lowest Mt. Woomyeun. Among a total of 109, coliform was detected from 21 spring waters(19.3%) and the geometric mean of coliform was 0.005 MPN/100ml. The isolated genera of coliform were 7 isolates of E. coli(33%), 5 Klebsiella(24%), 4 Enterobacter(19%), 3 Citrobacter(14%) and 2 Serratia(10%), respectively. The 22 spring waters(20.2%) failed to meet the standard limits of drinking water based on regulation in Korea. The inappropriate rate of standard plate count in spring water was 4.5%, that of coliform was 81.1% and both of them was 13.6%. There was the significant correlation between standard plate count and psychrotrophilic bacteria in spring water(r=0.95, p<0.01).

The Observation and a Quantitative Evaluation of Viable but Non-Culturable Bacteria in Potable Groundwater Using Epifluorescence Microscopy (형광현미경을 이용한 음용 지하수내 배양불능 세균의 관찰 및 정량적 평가)

  • ;Takashi Someya
    • Korean Journal of Microbiology
    • /
    • v.38 no.3
    • /
    • pp.180-185
    • /
    • 2002
  • The direct viable count (DVC) and plate count (PC) methods was used to measure the number of bacteria in potable groundwater samples collected from bottled water from the market, mineral water, and edible groundwater near the urban areas and the stock farming congested areas. As a result, the number of living bacteria by DVC was comprised 30~80% of the total direct count (TDC), whereas the number of living bacteria by PC was around l~30% of DVC. Such results show that viable but non-culturable (VBNC) bacteria exist in the potable groundwater with high percentages. On the other hand, upon measuring the value from the conventional nutrient broth (NB), $10^-2$ fold diluted nutrient broth (DNB), and R2A broth, the values from the DNB and R2A showed 2~50 times higher than the conventional NB medium. These results indicate that oligotrophic bacterial groups which can multiply in the low nutrient broth abundantly exist in the oligotrophic environment like potable groundwater.

Design and performance evaluation of portable electronic nose systems for freshness evaluation of meats II - Performance analysis of electronic nose systems by prediction of total bacteria count of pork meats (육류 신선도 판별을 위한 휴대용 전자코 시스템 설계 및 성능 평가 II - 돈육의 미생물 총균수 예측을 통한 전자코 시스템 성능 검증)

  • Kim, Jae-Gone;Cho, Byoung-Kwan
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.4
    • /
    • pp.761-767
    • /
    • 2011
  • The objective of this study was to predict total bacteria count of pork meats by using the portable electronic nose systems developed throughout two stages of the prototypes. Total bacteria counts were measured for pork meats stored at $4^{\circ}C$ for 21days and compared with the signals of the electronic nose systems. PLS(Partial least square), PCR (Principal component regression), MLR (Multiple linear regression) models were developed for the prediction of total bacteria count of pork meats. The coefficient of determination ($R_p{^2}$) and root mean square error of prediction (RMSEP) for the models were 0.789 and 0.784 log CFU/g with the 1st system for the pork loin, 0.796 and 0.597 log CFU/g with the 2nd system for the pork belly, and 0.661 and 0.576 log CFU/g with the 2nd system for the pork loin respectively. The results show that the developed electronic system has potential to predict total bacteria count of pork meats.

Scientific Consideration in Determining Shelf Life of Market Milk (시유의 유통기간 결정에 관한 학문적 고찰)

  • Choi, Suk-Ho
    • Journal of Dairy Science and Biotechnology
    • /
    • v.22 no.1
    • /
    • pp.27-35
    • /
    • 2004
  • The shelf lift of market milk should be determined based on the flavor which is influenced by environmental and sanitary conditions of dairy farm, milk processing plant, and storage and transportation facility as well as compositional quality, such as protein and fat, of the milk itself. The legal shelf life of market milk is often limited by microbiological quality, e.g. total bacterial count, coliform count, and food poisoning bacteria. The bacteria involved with milk spoilage and poisoning are originated from bacteria contaminating milk after pasteurization or spores surviving the heat treatment of pasteurization. The important factors which influence the shelf life of market milk are microbiological quality of raw milk, pasteurization condition, post-pasteurization contamination, and temperature during storage and transportation. The organoleptic quality and shelf life of market milk should be further improved by satisfying the consumer's taste, which depends on somatic cell count and bacterial count of milk, feed quality, foreign substance in milk, and physical treatment during processing and transportation.

  • PDF

ADHERENCE OF ORAL BACTERIA ON CHITOSAN-ADDED DENTURE BASE MATERIALS IN VITRO (키토산을 첨가한 의치상 재료의 세균 부착에 관한 연구)

  • Chung Sung-Hwan;Vang Mong-Sook;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.525-535
    • /
    • 2002
  • The purposes of this study were to evaluate the adherence of bacteria on various denture base resin materials and effects of chitosan, added to denture base materials on bacterial adherence. PMMA denture base resin such as heat-cured Vertex-RS, self-cured Vertex-SC and 4-META denture base resin such as heat-cured Meta-Dent, self-cured Meta-Fast were used in this study Samples were divided into two groups the denture base resin with chitosan, without chitosan Streptococcus mutans and Lactobacillus casei were used in this study. The surface of samples was observed by SEM. When chitosan was added to M17 and MRS broth, viable cell count of bacteria was reduced. Viable cell count of Streptococcus mutans on the samples decreased as follows : Meta-Dent, Vertex-SC, Meta-Fast, Vertex-RS. Viable cell count of Lactobacillus casei on the samples decreased as follows: Vertex-RS, Meta-Dent, Meta-Fast, Vertex-SC. The resin with chitosan showed lower adherence of bacteria than without chitosan. The images of SEM showed that the surface of the resin with chitosan was rougher than that of without chitosan. These results showed that the denture base resin materials with chitosan have rougher surface than without chitosan, but less bacteria adhered on them.

Characterization of Culturable Bacteria in the Atmospheric Environment in Incheon, Korea (인천지역 대기 환경 중 배양성 세균의 특성)

  • Lee, Siwon;Park, Su Jeong;Kim, Ji Hye;Min, Byung-Dae;Chung, Hyen-Mi;Park, Sangjung
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.2
    • /
    • pp.126-132
    • /
    • 2016
  • Objectives: This study aims to provide basic data regarding the bacterial total plate count in the atmospheric environment for related studies. Methods: Total plate count and the identification of culturable bacteria in the atmospheric environment in Incheon took place in 2015 using periodic survey. Correlationship analysis was performed between the number of culturable bacteria and environmental elements. In addition, an estimation of novel bacterial species was undertaken using the similarities and phylogenetic tree based on the 16S rRNA gene. Results: The total plate count of culturable bacteria was on average $176CFU/m^3$, and did not exceed $610CFU/m^3$ in the atmospheric environment. Periodic monthly measuring of total plate count was highest in June at $293CFU/m^3$, while the lowest was in July at $125CFU/m^3$. Furthermore, as a result of the identification of culturable bacteria, the genera Arthrobacter and Kocuria were dominant, while novel bacterial taxa that belong to the genera Chryseobacterium and Herbiconiux were separated. Conclusion: The total number of culturable bacteria from the atmospheric environment in Korea is on average $176CFU/m^3$. In addition, the genera Arthrobacter and Kocuria dominate. The presence of novel bacterial taxa are expected in the atmospheric environment, such as belonging to the genera Chryseobacterium and Herbiconiux.

The Detection and a Quantitative Evaluation of Viable but Non-Culturable Soil Bacteria Using a Modified Direct Viable Count Method (변형된 DVC법을 이용한 난배양성 토양세균의 검출 및 정량적 평가)

  • 황경숙;양희찬;염곡효
    • Korean Journal of Microbiology
    • /
    • v.39 no.3
    • /
    • pp.181-186
    • /
    • 2003
  • This study was performed to analyze quantitatively the number of living bacteria in forest soil samples collected from Mt. Keryong using improved direct viable count (DVC) and plate count (PC) methods. The number of living bacteria by DVC comprised 18~44% of the total direct count (TDC), whereas the number of living bacteria by PC was less than 1% of TDC. These results showed that viable but non-culturable (VBNC) bacteria existed in the soil with high percentages. Besides, DVC was proved to make it possible to make a quantitative detection of the VBNC bacteria. On the other hand, upon measuring the value from the conventional nutrient broth (NB) and $10^{-2}$ folded diluted nutrient broth (DNB), the values from the DNB showed 5 to 10 times higher than those from the conventional NB medium. These results indicate that oligotrophic bacterial groups, which could multiply in the low nutrient broth, abundantly exist in the soil ecosystem. It would also be possible to apply this kind of method to other substrate to make a quantitative detection of soil bacterial groups.

Optimal Protocol for Enumeration of Attached Bacteria on Glass Slides

  • Lee, Hyun-Sang;Kwon, Kae-Kyoung;Lee, Jong-Ho;Lee, Hong-Kum
    • Journal of Microbiology
    • /
    • v.37 no.4
    • /
    • pp.263-266
    • /
    • 1999
  • In examining bacterial growth on glass surfaces immersed in sea water, we found serious differences between enumeration methods. Therefore, we compared various methods and found sonication and direct count methods were superior to other methods. Since the direct count method was not suitable for long-term investigation, we chose the sonication method and confirmed that sonication periods 8 times for 30 seconds was optimal for the detachment of bacteria from glass surfaces.

  • PDF

Reduction of bacterial regrowth in treated water by minimizing water stagnation in the filtrate line of a gravity-driven membrane system

  • Yi, JongChan;Lee, Jonghun;Jung, Hyejin;Park, Pyung-Kyu;Noh, Soo Hong
    • Environmental Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.17-23
    • /
    • 2019
  • This study monitored changes in the level of heterotrophic bacteria in the filtrate and investigated the effect of stagnant water on it, using a batch-operated, gravity-driven membrane system for household water treatment. The filtration test was carried out in the presence and absence of stagnant water in the filtrate line. The results showed that stagnant water accelerated the heterotrophic bacteria levels, measured by heterotrophic plate count, even though the heterotrophic plate count of the filtrate finally increased up to $10^5CFU/mL$ regardless of the presence of stagnant water. When the change in heterotrophic plate count of a batch was monitored over filtration time, heterotrophic plate count of the filtrate rapidly decreased within 5 min for each batch filtration. Biofilm formation on the filtrate line was observed in the presence of stagnant water. The biofilm fully covered the filtrate line and contained numerous microorganisms. During storage after filtration, heterotrophic plate count increased exponentially. To improve the filtrate quality of a filtration-based household water treatment system, therefore, the stagnant water in the filtrate line should be minimized, the filtrate produced at the first 5 min is recommended not to be used as potable water, and the storage of filtrate should be avoided.