• Title/Summary/Keyword: Cost of Radiation Oncology

검색결과 44건 처리시간 0.026초

Cost-Effectiveness of Intensive Vs. Standard Follow-Up Models for Patients with Breast Cancer in Shiraz, Iran

  • Hatam, Nahid;Ahmadloo, Niloofar;Vazirzadeh, Mina;Jafari, Abdossaleh;Askarian, Mehrdad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권12호
    • /
    • pp.5309-5314
    • /
    • 2016
  • Background: Breast cancer is the most common type of cancer amongst women throughout the world. Currently, there are various follow-up strategies implemented in Iran, which are usually dependent on clinic policies and agreement among the resident oncologists. Purpose: A cost-effectiveness analysis was performed to assess the cost-effectiveness of intensive follow-up versus standard models for early breast cancer patients in Iran. Materials and methods: This cross sectional study was performed with 382 patients each in the intensive and standard groups. Costs were identified and measured from a payer perspective, including direct medical outlay. To assess the effectiveness of the two follow-up models we used a decision tree along with indicators of detection of recurrence and metastasis, calculating expected costs and effectiveness for both cases; in addition, incremental cost-effectiveness ratios were determined. Results: The results of decision tree showed expected case detection rates of 0.137 and 0.018 and expected costs of US$24,494.62 and US$6,859.27, respectively, for the intensive and standard follow-up models. Tornado diagrams revealed the highest sensitivity to cost increases using the intensive follow-up model with an ICER=US$148,196.2. Conclusion: Overall, the results showed that the intensive follow-up method is not cost-effective when compared to the standard model.

Potential Role of Electrochemotherapy as Anticancer Treatment for Cutaneous and Subcutaneous Lesions

  • Zygogianni, Anna;Kyrgias, George;Scarlatos, John;Koukourakis, Michael;Souliotis, Kyriakos;Kouvaris, John;Kelekis, Nikolaos;Kouloulias, Vassilis
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권8호
    • /
    • pp.3753-3757
    • /
    • 2016
  • Background: The aim of this study was to investigate whether electrochemotherapy is a clinically and cost-effective treatment option against skin tumors. Materials and Methods: We performed an analysis of the current literature based on database searches in PubMed/MEDLINE and we included articles till July 2012. Terms used for the search were 'electrochemotherapy', 'skin cancer', 'recurrence', and 'cutaneous and subcutaneous tumors'. Only papers published in English were included. In addition, we performed an analysis of the cost effectiveness of the method. Results: The combination of physics and chemistry is the foundation for electrochemotherapy and its efficacy, independent of the tumor histology. Clinical data showed that ECT is well tolerated and can be used in difficult cases without other available treatment options. The analysis also showed that the treatment is feasible and cost-effective. Conclusions: Electrochemotherapy is a clinically efficient safe and cost-effective treatment and clinicians should not hesitate to use it as alternative therapeutic modality or as palliative treatment.

Concurrent Chemoradiation with Weekly Cisplatin for the Treatment of Head and Neck Cancers: an Institutional Study on Acute Toxicity and Response to Treatment

  • Ghosh, Saptarshi;Rao, Pamidimukkala Brahmananda;Kumar, P Ravindra;Manam, Surendra
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권16호
    • /
    • pp.7331-7335
    • /
    • 2015
  • Background: Concurrent chemoradiation with three weekly high dose cisplatin is the non-surgical standard of care for the treatment of locally advanced head and neck cancers. Although this treatment regime is efficacious, it has high acute toxicity, which leads not only to increased treatment cost, but also to increased overall treatment time. Hence, the current study was undertaken to evaluate the acute toxicity and tumor response in head and neck cancer patients treated with concurrent chemoradiation using $40mg/m^2$ weekly cisplatin, which has been our institutional practice. Materials and Methods: This single institution retrospective study included data for 287 head and neck cancer patients treated with concurrent chemoradiation from 2012 to 2014. Results: The mean age of the patients was 48.8 years. The most common site of involvement was oral cavity. Most of the study patients presented with advanced stage disease. The mean overall treatment time was 56.9 days. Some 67.2% had overall complete response to treatment as documented till 90 days from the start of treatment. According to the Radiation Therapy Oncology Group (RTOG) acute radiation morbidity scoring criteria, mucositis was seen in 95.1% of the patients. Dermatitis and emesis were observed in 81.9% and 98.6%, respectively. Regarding haematological toxicity, 48.8% and 29.6% suffered from anaemia and leukopenia, respectively, during treatment. Acute kidney injury was assessed using the Common Terminology Criteria for Adverse Events (CTCAE), and was found in 18.8% of the patients. Conclusions: Concurrent chemoradiotherapy with weekly cisplatin is an effective treatment regime for head and neck cancers with reasonable toxicity which can be used in developing countries, where cost of treatment is so important.

치료 계획용 전산화 단층촬영이 방사선 치료계획에 미치는 효과 (The Effect of Therapy Oriented CT in Radiation Therapy Planning)

  • 김성규;신세원;김명세
    • Radiation Oncology Journal
    • /
    • 제5권2호
    • /
    • pp.149-155
    • /
    • 1987
  • 전산화 단층촬영 (CT)은 진단 분야 뿐 아니라 방사선 치료 계획 및 치료효과의 추적 등 치료분야에 까지 광범위하게 사용되고 있다. 그러나 환자의 체위가 치료시와는 다름으로 얻어진 영상이 치료시의 영상과는 차이가 있으며, 삼차원적인 치료면적의 계산이 곤란할 뿐 아니라 조영제를 사용함으로 생길 수 있는 선량계산의 오라 및 정확한 조사야가 표현되지 많음으로 병소 및 중요 정상장기의 선량 측정이 정확하지 못한점 등의 단점이 없다. 저자들은 1986년 5월 1일부터 1987린 4월 30일까지 영남대학병원 치료방사선과에서 치료받은 총 365명의 환자 중 일반 CT의 단점을 보완한 치료용 CT와 종래의 simulation을 병행한 106명의 치료계획을 비교 분석하여 다음과 같은 결과를 얻었다. 치료용 CT후 두경부 암 환자의 $47\%$, 흉부암 환자의 $79\%$, 복부암 환자의 $63\%$에서 치료계획의 변경이 있어 치료용 CT가 두경부암, 흉부암, 복부암에서 거의 철수적임을 시사하였다. 그러나 직장암, 자궁경부암에서는 추가치료의 조사야의 측정 및 선량계산 이외의 전예에서 치료계획의 변경이 없었다. 선량분포의 비교측정에서는 윤곽만을 사용한 종래의 선량계산이 CT를 사용한 경우에 비해서 두경부암에서는 평균 $20\%$, 흉부암, 복부암에서는 약 $10\%$의 차이를 보여 전례에서 CT보다 과측정 되었음을 보여 종래의 윤곽만을 사용한 치료계획시의 저선량 조사에 대한 보정이 필요함을 시사하였다.

  • PDF

선형가속기의 품질관리를 위한 2차원이온전리함배열의 유용성 (Feasibility of Two Dimensional Ion Chamber Array for a Linac Periodic Quality Assurance)

  • 이정우;홍세미;박병문;강민영;김유현;서태석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.183-188
    • /
    • 2008
  • 본 연구의 목적은 방사선치료용 선형가속기의 품질관리를 수행하기 위한 2차원이온전리함배열의 유용성을 검증하기 위함이다. 물팬톰과 필름으로 수행하던 기존의 품질관리 방법을 2차원이온전리함배열(MatriXX, Wellhofer Dosimetrie, Germany)을 이용하여 유용성을 검증하였다. MatriXX는 1,020개의 평판형 전리함(용적: $0.08\;cm^3$, 직경: 4.5mm, 높이: 5mm, 배열간격: 7.62mm)이 일정한 간격으로 $24{\times}24\;cm^2$의 면적에 배열 되어있다. MatriXX의 유용성을 검증하기 위해 연속된 5개월에 걸쳐 선량균등도, 에너지($TPR_{20,10}$), 그리고 절대 선량을 측정하여 물팬톰과 $0.65\;cm^3$ (FC65G, Wellhofer Dosimetrie, Germany) Farmer형 이온전리함을 통해 얻은 값과 비교, 분석하였다. MatriXX 측정 시 폴리스틸렌 고체 팬톰(${\rho}:\;1.18\;g/cm^3$)을 이용하였으며, MatriXX 고유의 커버 물질의 밀도와 두께(${\rho}:\;1.06\;g/cm^3$, t: 0.36 cm)를 물과 등가의 값으로 환산하여 적용하였다. 또한, 기하학적 점검을 위한 예비실험에서 콜리메이터의 회전축과 하프빔의 접합부를 필름측정의 결과와 비교하였다. 선량계측학적 실험 결과, MatriXX로 얻은 데이터와 물팬톰의 결과가 모든 항목에서 ${\pm}1%$ 이내의 일치를 보였다. 기하학 품질관리의 예비 실험 결과 기존의 필름방식과 유사한 결과를 얻었으며, 기하학적 품질관리의 정량적 분석 가능성을 제시하였다. 본 연구를 통해 주기적인 선형가속기의 품질관리에서 물팬톰과 필름을 대체할 수 있는 MatriXX의 유용성을 확인하였으며, 향후 비용절감과 시간과 인력을 절감할 수 있는 품질관리의 새로운 방법을 제시하였다.

  • PDF

Multiplex PCR Detection of Waterborne Intestinal Protozoa: Microsporidia, Cyclospora, and Cryptosporidium

  • Lee, Seung-Hyun;Joung, Mi-Gyo;Yoon, Se-Joung;Choi, Kyoung-Jin;Park, Woo-Yoon;Yu, Jae-Ran
    • Parasites, Hosts and Diseases
    • /
    • 제48권4호
    • /
    • pp.297-301
    • /
    • 2010
  • Recently, emerging waterbome protozoa, such as microsporidia, Cyclospora, and Cryptosporidium, have become a challenge to human health worldwide. Rapid, simple, and economical detection methods for these major waterborne protozoa in environmental and clinical samples are necessary to control infection and improve public health. In the present study, we developed a multiplex PCR test that is able to detect all these 3 major waterborne protozoa at the same time. Detection limits of the multiplex PCR method ranged from $10^1$ to $10^2$ oocysts or spores. The primers for microsporidia or Cryptosporidium used in this study can detect both Enterocytozoon bieneusi and Encephalitozoon intestinalis, or both Cryptosporidium hominis and Cryptosporidium paNum, respectively. Restriction enzyme digestion of PCR products with BsaBI or BsiEI makes it possible to distinguish the 2 species of microsporidia or Cryptosporidium, respectively. This simple, rapid, and cost-effective multiplex PCR method will be useful for detecting outbreaks or sporadic cases of waterborne protozoa infections.

전자포탈영상을 이용한 다엽시준기의 정도관리 (Quality Assurance of Multileaf Collimator Using Electronic Portal Imaging)

  • 진호상;;최보영;이형구;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.151-160
    • /
    • 2003
  • 삼차원 입체조형방사선치료나 세기조절방사선치료와 같은 다엽시준기(Multileaf Collmator, MLC)를 이용하는 보다 복잡한 방사선 치료 기술은 다엽시준기의 위치 및 운동의 검증의 중요성을 증가시키고 있다. 이러한 다엽시준기의 검증은 신뢰성과 그동안 축척된 경험적 검증능력으로 인하여 주로 필름을 가지고 수행되어왔다. 그러나 전자포탈영상장치(Electornic Portal Imaging Device, EPID)의 사용의 편이성과 디지털 영상 제공 능력은 낮은 임상편이성, 효율성, 비용대 수익률에도 불구하고 정기적인 정도확립(Quality Assurance, QA)에 현실적인 필름의 대체재로 관심을 모아왔다. 본 연구에서는 EPI를 활용한 다엽시준기의 정기적인, 특히 일간 정도확립법을 개발하였다. 정기적 정도확립을 위한 전자포탈영상(Electronic Portal Imaing, EPI)의 적용가능성에 대한 검증은 방사선 조사시 동시에 획득된 필름과 다엽시준기의 제어장치에 입력한 다엽시준기의 처방과의 비교를 통해 수행되었다. 특별히 설계된 두가지 형태의 시험형(test pattern)이 영상 획득 및 비교에 적용되었다. 정성적인 온라인 육안 검증과 함께 윤곽 검출 알고리듬을 이용한 정량적인 오프라인 분석이 검증 절차에 이용되었다. 결론적으로, 본 연구에서 개발된 EPI를 이용한 다엽시준기의 일간 정도확립법은 필름의 정확도를 가지고 편리하게 수행될 수 있었다.

  • PDF

고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰 (A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources)

  • 백태성;이승욱;나수경
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.19-26
    • /
    • 2007
  • 목 적: Ir-192 고선량율 근접치료(HDR Brachytherapy)선원에 대한 다양한 측정절차의 효율을 서로 비교할 것이며, 측정 장비의 추가 구입 없이 대안으로 새롭게 만든 PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom에 대한임상에서의 적합성과 유용성을 알아 보았다. 대상 및 방법: 세 가지 형태(Well type chamber, Source calibration jig, PMMA plate phantom)의 측정 시스템을 이용하여 측정값을 비교하였다. Source calibration jig와 PMMA plate phantom을 사용 했을 때에는 Farmer type chamber를 이용하여 측정하였으며, 각각 5회씩 측정하여 제조업체의 측정치와 비교하였다. 또한 새로운 선원을 교환 할 때마다 제조업체로부터 선원과 함께 제공되는 제조업체의 측정치를 본 연구의 측정치와 비교하여 방사능의 정확도를 평가 하였다. 결 과: Well type chamber, Source calibration jig, PMMA plate phantom를 사용한 Ir-192 선원의 측정결과 제조업체 측정치와의 상대오차에 대한 RMS (Root Mean Square)값은 Well type chamber에서 0.6%, Source calibration jig에서 1.57%, PMMA plate phantom에서는 2.1%를 나타내었다. 또한 평균 오차에 대한 편차는 Well type chamber에서 $-0.2{\pm}0.5%$, Source calibration jig에서 $0.97{\pm}1.23%$, PMMA plate phantom에서는 $-0.89{\pm}1.87%$를 나타내었다. 결 론: 본 연구를 통해 실험한 세 가지 형태(Well type chamber, Source calibration jig, PMMA plate phantom)의 측정 시스템의 결과에서 나타난 것처럼, Well type chamber를 이용한 측정결과가 가장 우수하게 나타났다. 또한 측정 장비를 구입하지 않고 대안으로 새롭게 만든 PMMA plate phantom의 결과 권고안 ${\pm}5%$를 초과하지 않으므로 임상에서 유용하게 사용 할 수 있을 것이라 생각되어진다.

  • PDF

A Nation-Wide Epidemiological Study of Newly Diagnosed Primary Spine Tumor in the Adult Korean Population, 2009-2011

  • Sohn, Seil;Kim, Jinhee;Chung, Chun Kee;Lee, Na Rae;Sohn, Moon Jun;Kim, Sung Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권2호
    • /
    • pp.195-204
    • /
    • 2017
  • Objective : This 2009-2011 nation-wide study of adult Koreans was aimed to provide characteristics, medical utilization states, and survival rates for newly diagnosed patients with primary nonmalignant and malignant spine tumors. Methods : Data for patients with primary spine tumors were selected from the Korean Health Insurance Review and Assessment Service database. The data included their age, sex, health insurance type, co-morbidities, medical cost, and hospital stay duration. Hospital stay duration and medical costs per person occurring in one calendar year were used. In addition, survival rates of patients with primary malignant spine tumors were evaluated. Results : The incidence rate of a primary spine tumor increased with age, and the year of diagnosis ($p{\leq}0.0001$). Average annual medical costs ranged from 1627 USD (pelvis & sacrum & coccyx tumors) to 6601 USD (spinal cord tumor) for primary nonmalignant spine tumor and from 12137 USD (spinal meningomas) to 20825 USD (pelvis & sacrum & coccyx tumors) for a primary malignant spine tumor. Overall survival rates for those with a primary malignant spine tumor were 87.0%, 75.3%, and 70.6% at 3, 12, and 24 months, respectively. The Cox regression model results showed that male sex, medicare insurance were significantly positive factors affecting survival after a diagnosis of primary malignant spine tumor. Conclusion : Our study provides a detailed view of the characteristics, medical utilization states, and survival rates of patients newly diagnosed with primary spine tumors in Korea.

악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료 (Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors)

  • 권다은;황지혜;박인서;양준철;김수진;유아영;원영진;권경태
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.75-81
    • /
    • 2019
  • 목 적: 두피 악성종양의 치료에 광자선을 사용할 때 필요한 Bolus 재질들의 단점으로 인하여 3D Printer용 헬멧형 bolus가 제작되고 있다. 하지만 사용되는 재질인 PLA은 조직등가물질에 비해 높은 밀도를 가지고 있으며 환자가 착용할 경우 불편한 점들이 발생한다. 이에 본 연구에서는 3D Printer를 이용한 M3 wax 헬멧을 제작하여 악성 두피종양을 치료하는 방법을 시도해 보고자 한다. 대상 및 방법: 헬멧형 M3 wax의 모델링을 위해 두부인체모형팬텀을 CT로 촬영해 DICOM file로 획득하고, 두피 위에 헬멧이 위치할 부위를 Helmet contour로 제작하였다. M3 Wax 헬멧의 제작은 paraffin wax를 녹이고, 산화마그네슘, 탄산칼슘을 섞어 용해시킨 후 PLA 3D 헬멧의 내부에 넣고 표면의 PLA 3D 헬멧을 제거하였다. 치료계획은 총 10 Portal의 Intensity-Modulated Radiation Therapy(IMRT)로 세웠으며, 치료선량은 200 cGy로 eclipse의 Analytical Anisotropic Algorithm(AAA)를 사용하였다. 그 후 EBT3 film과 Mosfet(Metal Oxide Semiconductor Field Effect Transistor: USA)를 이용해 선량검증을 실시하였으며, CT 모의치료실과 동일한 조건으로 두부인체모형팬텀을 재현해 IMRT Plan을 측정하였다. 결 과: CT상에서 측정된 Bolus의 Hounsfield unit(HU)는 $52{\pm}37.1$으로 나타났다. M3 wax bolus 측정점 A, B, C에서 TPS의 선량은 186.6 cGy, 193.2 cGy, 190.6 cGy으로 확인되었고, Mostet으로 3회 측정한 선량은 $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$, $195.33{\pm}1.69cGy$, 오차율은 -3.71 %, -4.59 %, +2.48 %였다. EBT3 Film으로 측정된 선량은 $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$, $196{\pm}2.16cGy$이었으며, 오차율은 -2.46%, +0.23 %, +2.83 %로 확인되었다. 결 론: M3 wax bolus는 2 cm의 두께로 제작되어 뇌 부분의 선량을 보다 쉽게 낮추어 치료계획을 수립할 수 있었다. 치료선량 검증에서의 EBT3 Film과 Mosfet의 선량계의 A, B, C 측정값에서도 두피의 표면선량 최대 오차율은 5 % 이내로 측정되었으며, 일반적으로 3 % 이내로 정확하게 측정되었다. M3 wax bolus는 제작과정 기간이 3D Printer보다 빠르고 비용이 저렴하며, 재사용 가능하고, 인체조직 등가물질로서 두피 악성종양 치료에 매우 유용한 Bolus이다. 따라서 3D Printer의 대용량 Bolus, Compensator의 제작시간 및 비용이 비싼 단점을 극복하는 주조형 M3 wax bolus의 사용이 추후 확대될 것으로 사료된다.