• 제목/요약/키워드: Cost Save

Search Result 752, Processing Time 0.025 seconds

Comparison of LPG/Diesel Sprays in high Pressure Injection System (고압 LPG/디젤연료의 분무특성 비교)

  • 박권하
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.77-85
    • /
    • 2000
  • LPG gains many advantages of a high octane number low emissions and low cost over conventional fuel. The fuel has been naturally used in engines to save running cost but the first generation fuel feeding system was not satisfied with stringent requirement for exhaust emissions, A liquid direct injection system into a cylinder has been suggested as a next generation system to maximize a fuel economy as well as to reduce emissions. In this paper LPG sprays are compared with diesel sprays in a high pressured surrounding condition in order to understand the high pressure spray characteristics, The spray images show that LPG spray penetrates further soon after the injection then the sprays stays in a distant. it may explain the flashing effect of LPG.

  • PDF

A Sutdy on the Apllicability of the Energy Pile System on Substation (변전소 구조물의 에너지파일 시스템 적용성 연구)

  • Lee, Daesoo;Oh, Gidae;Lee, Kangyul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.198-198
    • /
    • 2011
  • Cooling and Heating system using Geothermal energy in the country has shown rapid development in the research and business field during about 10 years. However, like other renewable energy sources, high initial construction cost is acting as an obstacle to apply widely. Therefore Energy pile system(Heat Exchanger inserted inside the structure pile) that can save about 25 % initial construction cost has been studied in European countries and recently being studied in our country. Therefore, KPECO(Korea Electric Power Corporation) is also studying energy pile system to improve cooling & heating system in substation that install about 200 pile. KPECO is aimed to make energy pile design, construction and maintenance standards because substation has good applicability. In this study, we studied to make new grout material and design program to make optimized design & counstruction method of energy pile system. And planing to peform field test for energy pile system in a 154 kV substation to obtain long-term behavior and efficiency of the system.

  • PDF

Study on Development of a Design Program for Torsion Beam Axle Suspension (Torsion Beam Axle 현가장치 설계전용 프로그램 개발을 위한 연구)

  • 이치범;현상혁;유홍희
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.198-203
    • /
    • 2003
  • Due to the low production cost and space availability which are originated from the structural simplicity of the torsion beam axle suspension, the suspension has been frequently used for sedan and SUV style vehicles. The design procedure of the suspension, however, requires significant amount of time which prohibits more efficient design of the suspension. In this study, an integrated procedure and constituting modules are explained and the performance of the corresponding program is exhibited. The integrated procedure enables one to save the design time and cost significantly.

Maintenance Staff Scheduling at Afam Power Station

  • Alfares, H.K.;Lilly, M.T.;Emovon, I.
    • Industrial Engineering and Management Systems
    • /
    • v.6 no.1
    • /
    • pp.22-27
    • /
    • 2007
  • This paper describes the optimization of maintenance workforce scheduling at Afam power station in Nigeria. The objective is to determine the optimum schedule to satisfy growing maintenance labour requirements with minimum cost and highest efficiency. Three alternative maintenance workforce schedules are compared. The first alternative is to continue with the traditional five-day workweek schedule currently being practiced by Afam power station maintenance line. The second alternative is to switch to a seven-day workweek schedule for the morning shift only. The third alternative is to use a seven-day workweek schedule for all three work shifts. The third alternative is chosen, as it is expected to save 11% of the maintenance labour cost.

A Study on the Oxide CMP Characteristics of using Mixed Abrasive Slurry(MAS) (혼합 연마제 슬러리를 이용한 Oxide CMP 특성에 관한 연구)

  • Lee, Sung-Il;Park, Sung-Woo;Lee, Woo-Sun;Seo, Yong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.601-602
    • /
    • 2006
  • Chemical mechanical polishing (CMP) technology has been widely used for global planarization of multi-level interconnection for ULSI applications. However, the cost of ownership and cost of consumables are relatively high because of expensive slurry. In this paper, we studied the mixed abrasive slurry(MAS). In order to save the costs of slurry, the original silica slurry was diluted by de-ionized water (DIW). And then, $ZrO_2$,$CeO_2$, and $MnO_2$ abrasives were added in the diluted slurry in order to promote the mechanical force of diluted slurry. We have also investigate the possibility of mixed abrasive slurry for the oxide CMP application.

  • PDF

A Study on the Oxide CMP Characteristics of using Mixed Abrasive Slurry(MAS) (혼합 연마제 슬러리를 이용한 Oxide CMP 특성에 관한 연구)

  • Lee, Sung-Il;Park, Sung-Woo;Lee, Woo-Sun;Seo, Yong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2233-2234
    • /
    • 2006
  • Chemical mechanical polishing (CMP) technology has been widely used for global planarization of multi-level interconnection for ULSI applications. However, the cost of ownership and cost of consumables are relatively high because of expensive slurry. In this paper, we studied the mixed abrasive slurry(MAS). In order to save the costs of slurry, the original silica slurry was diluted by de-ionized water (DIW). And then, $ZrO_2$, $CeO_2$,and $MnO_2$ abrasives were added in the diluted slurry in order to promote the mechanical force of diluted slurry. We have also investigate the possibility of mixed abrasive slurry for the oxide CMP application.

  • PDF

A Study on the Oxide CMP Characteristics of using Mixed Abrasive Slurry(MAS) (혼합 연마제 슬러리를 이용한 Oxide CMP 특성에 관한 연구)

  • Lee, Sung-Il;Park, Sung-Woo;Lee, Woo-Sun;Seo, Yong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2235-2236
    • /
    • 2006
  • Chemical mechanical polishing (CMP) technology has been widely used for global planarization of multi-level interconnection for ULSI applications. However, the cost of ownership and cost of consumables are relatively high because of expensive slurry. In this paper, we studied the mixed abrasive slurry(MAS). In order to save the costs of slurry, the original silica slurry was diluted by de-ionized water (DIW). And then, $ZrO_2$, $CeO_2$,and $MnO_2$ abrasives were added in the diluted slurry in order to promote the mechanical force of diluted slurry. We have also investigate the possibility of mixed abrasive slurry for the oxide CMP application.

  • PDF

The Study of Economical Efficiency for the Ice Storage System of more Energy Consumption Building (에너지 다소비형 건물 축냉 시스템의 경제성에 관한 연구)

  • Lee, Je-Myo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.733-738
    • /
    • 2012
  • It is important issue to reduce the electric energy to save the operating cost of HVAC system. Even if electrical energy is the clean energy, it is difficult and takes high cost for storage of electricity. These cause the high peak load of electric energy for HVAC in summer season. In korea, government impose the electric charge with several grade for the purpose of cut-off the peak load of electricity. Government has a policy to support to design and install the heat/ice storage system using midnight electricity. In this study, analysis of cooling load and operating characteristics for ice storage system are performed. And, also economical efficiency is compared between ordinary charge system of electricity and midnight rate charge of electricity. The systematic and economical supports are needed for expansion of usage of energy saving equipments.

New Adaptive Compandor for LTE Signal Compression Based on Spline Approximations

  • Velimirovic, Lazar Zoran;Maric, Svetislav
    • ETRI Journal
    • /
    • v.38 no.3
    • /
    • pp.463-468
    • /
    • 2016
  • With the constant increase in network traffic, wireless operators are finding it more challenging to keep network hardware costs to a minimum. At the same time, the energy cost associated with operating a network has increased proportionally. Therefore, the search for higher network capacity is simultaneously accompanied by the search for a cost-efficient network deployment. In this paper, we show that a saving in transmitted signal energy can be achieved at the signal design level by deploying very specific signal processing techniques. Using an orthogonal frequency-division multiplexing signal for Long-Term Evolution networks as an example, we utilize a novel non-uniform companding quantizer to save a transmitted signal energy. Our results show that by using non-uniform quantization it is possible to further optimize 4G wireless networks.

Optimal heat exchanger network synthesis through heuristics and system separation method (경험법칙과 계의 분리법을 통한 최적 열교환망 합성)

  • Lee, Hae-Pyeong;Ryu, Gyeong-Ok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.1 no.2
    • /
    • pp.119-126
    • /
    • 1995
  • The purpose of this study is to develop the technique of energy recovery and energy saving by using the optimization of heat exchanger network synthesis. This article proposes a new method of determining the optimal target of a heat exchanger network synthesis problem of which data feature multiple pinch points. The system separation method we suggest here is to subdivide the original system into independent subsystems with one pinch point. The optimal cost target was evaluated and the original pinch rules at each subsystem were employed. The software developed in this study was applied to the Alko prosess, which is an alcohol production process, for the synthesis of heat exchanger network. It was possible to save about 15% of the total annual cost.

  • PDF