• Title/Summary/Keyword: Cortical bone resorption

Search Result 59, Processing Time 0.027 seconds

AN EXPERIMENTAL STUDY OF $GUIDOR^{(R)}$ BARRIER MEMBRANE ABOUT BONE PROMOTION AROUND DENTAL IMPLANTS PLACED INTO EXTRACTION SOCKET IN DOGS (성견의 Implant 주위에 $GUIDOR^{(R)}$ BARRIER MEMBRANE 사용후 골신생에 관한 실험적 연구)

  • Yang, Myeong-Cheol;Jin, Woo-Jeong;Shin, Hyo-Keun;Kim, Oh-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.1
    • /
    • pp.135-143
    • /
    • 1996
  • The aim of this study was to evaluate bone promotion of bioreabsorbable guided tissue regeneration for generating new bone adjacent to osseointegrated implants in dogs. Third premolars were extracted in dgo mandibles. Cylindrical HA-coated implants were placed into extracted sockets in dogs. And test sites were protected by $GUIDOR^{(R)}$ matrix barrier. But control sites were not protected by membrances. The sites were examined clinically, radiologically, and histologically after 1, 2, and 4 months to assess bone regeneration. The results obtained were as foolows : 1. There were the good healing and the stability of $GUIDOR^{(R)}$ matrix barrier in experimental site during the healing period. 2. Complete resorption of $GUIDOR^{(R)}$ matrix barrier was clinically observed about 4 months postoperatively. 3. The woven bone changed to mature bone with a normal cortical plate and mature, resting periosteum after 4 months. 4. In experimental site, there was a significantly greater bone promtion than observed in control site. 5. $GUIDOR^{(R)}$ matrix barrier was useful for the preparation of immediate dental implants.

  • PDF

Tissue changes of pulp and periodontium on rapid tooth movement with osteotomy in dogs (골절단을 이용한 급속 치아이동 후 치수 및 치주조직 변화)

  • Kang, Kyung-Hwa;Kim, Eun-Cheol;Lee, Sun-Kyung;Lim, Chae-Woong;Matduda, Kiku;Tae, Ki-Chul;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.34 no.2 s.103
    • /
    • pp.131-142
    • /
    • 2004
  • The movement of tooth-bone segments by osteotomy can simultaneously shift tooth and surrounding alveolar bone in a relatively short period. The purpose of this study was to evaluate the tissue changes in pulp, periodontal ligament, and alveolar bone in rapid tooth-bone movement with osteotomy. The mandibular 3rd premolar of a dog was extracted and cortical bones of the buccal and lingual area were eliminated, and then cortical bones around the mesial and distal area of root, and below the root apex of the mandibular 4th premolar were osteotomized. After a one-week latency period, a tooth-borne distraction device was activated for 6 days. And pulp, periodontal ligament and alveolar bone were evaluated clinically, radiologically, histologically and immunohistochemically at 0, 1, 2, 4, 6, 8 weeks of the consolidation Period and conclusions were roached as follows. 1. Latency period didn't affect total amount or tooth movement and healing process of tissue during consolidation period. 2. Bone formation continued through 8 weeks of consolidation in distracted side, with a high peak at 1-2 weeks, and the lowest at 6-8 weeks or consolidation. 3. At 1 week of consolidation, alveolar bone resorption, osteoclast appearance and inflammatory cell infiltration were the most active, and dentinoclasts characteristically appeared on the pulp and pressure side of the periodontal ligament. 4. The expression of $TGF-\beta$ was area-specific, as it was strong-positive at bone matrix, osteoblast osteoclast of alveolar bone, and dentinoclast inside pulp, but weak in pulp, cementoblast and acellular cementum. 5. The expression of $TGF-\beta$ was generally observed at the initial 1-2 weeks of consolidation at vessels, periodontal ligament cells, and osteoblast near alveolar bone on the distraction side of the periodontal ligament, and was significantly decreased after 6 weeks of consolidation.

A CASE REPORT OF PRIMARY INTRA-OSSEOUS CARCINOMA OF THE MAXILLA (상악골에 발생한 원발성 골내암종)

  • Park In-Woo;Choi Soon-Chul;Lee Young-Ho;Park Tae-Won;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.135-144
    • /
    • 1997
  • The primary intra-osseous carcinoma (PIOC) is a very rare lesion. PIOC is an odontogenic carcinoma defined as a squamous cell carcinoma arisinig within a jaw having no initial connection with the oral mucosa, and presumably developing from residues of the odontogenic epithelium. The authors diagnosed a 51-year-old female as primary intra-osseous carcinoma after undergoing clinical, radiological and histological examinations. The characteristics were as followed : 1. The patient complained of gingival bleeding on the premolar area in the left maxilla 2. The conventional radiograms showed a relatively well-defined unilocular radiolucent lesion from the mesial aspect of the upper left canine to the mesial aspect of the upper left 1st molar. The 2nd premolar was separated from the 1st molar and the floor of the maxillary sinus was elevated by the lesion. There was a external root resorption of the upper left canine, the 1st premolar, and the 2nd premolar. 3. On the computed tomograms, the osteolytic bony lesion expanded the cortical plate of the left maxilla and displaced the margin of the left maxillary sinus upwards. But the bony lesion was separated from the maxillary sinus by a bony septum. 4. Bone scintigram with /sup 99m/Tc demonstrated the increased uptake in the left maxilla. Sonograms in the neck area and chest P-A radiogram didn't show any abnormalities. 5. Histologically, the tumor islands infiltrating into the surrounding bone increased in alveolar pattern, composed of the malignant cells, and there was a necrosis in the center of the tumor islands.

  • PDF

Clinical study of benign and malignant fibrous-osseous lesions of the jaws

  • Lee, Ju-Min;Song, Won-Wook;Lee, Jae-Yeoul;Hwang, Dae-Seok;Kim, Yong-Deok;Shin, Sang-Hun;Chung, In-Kyo;Kim, Uk-Kyu
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.1
    • /
    • pp.29-37
    • /
    • 2012
  • Introduction: Fibrous-osseous lesions of the jaws are difficult to diagnose precisely until excised biopsy results are found, so they might be confused with malignant lesions. This clinical study focused on the diagnostic aids of lesions that demonstrate different clinical, radiologic, and histological findings. Materials and Methods: A total of 16 patients with benign fibrous-osseous lesions on the jaws (6 fibrous dysplasias, 6 ossifying fibromas, 3 cemental dysplasias, and one osteoblastoma) were reviewed. Nine patients with malignant fibrous-osseous lesions (8 osteosarcomas and one Ewing's sarcoma) were also retrospectively reviewed. Results: Osteosarcoma patients complained of facial swelling and tooth mobility. The radiographic findings showed the irregular resorption of cortical bone and periosteal reactions. Histological features included cellular pleomorphism and atypical mitosis. An Ewing's sarcoma patient complained of tooth mobility and facial swelling. Onion-skin appearance and irregular expansile marginal bony radiolucency were seen in the radiography. Fibrous dysplasia patients complained of facial swelling and asymmetry. The radiographic features were mostly ground-glass radiopacity. Histological findings showed a bony trabeculae pattern surrounded by fibrous ground substances. Ossifying fibroma patients complained of buccal swelling and jaw pains, showing expanded cortical radiolucent lesions with a radiopaque margin. Histological findings were revealed as cellular fibrous stroma with immature woven bones. In cemental dysplasia, most of their lesions were found in a routine dental exam. Well-circumscribed radiopaque lesions were observed in the radiography, and cementum-like ossicles with fibrous stroma were seen in the microscopy. An osteoblastoma patient complained of jaw pain and facial swelling. Radiographic findings were mottled, dense radiopacity with osteolytic margin. Trabeculae of the osteoid with a vascular network and numerous osteoblasts with woven bone were predominantly found in the microscopy. Conclusion: Our study showed similar results as other studies. We suggest the clinical parameters of diagnosis and treatment for malignant and benign fibrous-osseous lesions of the jaws.

EFFECT OF THE LATENCY PERIOD ON ALVEOLAR RIDGE DISTRACTION USING THE INTRAORAL DISTRACTION DEVICE IN DOGS (구내 신연장치를 이용한 치조골 신연에 미치는 잠복기의 영향)

  • Oh, Yu-Keun;Oh, Hee-Kyun;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.4
    • /
    • pp.324-331
    • /
    • 2001
  • The present study was aimed to investigate the effects of latency period on alveolar ridge distraction using the intraoral distraction device. Nine adult mongrel dogs of either sex, weighing about 15kg, were used. They were divided into 3-day, 5-day, and 7-day groups according to the latency period. The left upper and lower premolars and first molars were extracted. Twelve weeks after the extraction, an osteotomy was performed and the distraction device was applied. After the latency period, the distraction was applied at a rate of 1.2mm for 8 days. The distraction device was left in place for 2 weeks to allow consolidation and was then removed. The animals were sacrified at 8 weeks after completion of distraction and were examined macroscopically, radiographically, and histologically. After completion of the distraction, the alveolar crest protruded prominently, showing the vertical augmentation of the alveolar bone. Soft tissues were broken down after the 6th day of distraction in 3-day latency group, and premature union occurred on the 7th day of distraction in the 7-day latency group. The average distance was $9.40{\pm}0.3mm$ in 3-day latency group, $9.35{\pm}0.1mm$ in 5-day latency group, and $8.85{\pm}0.1mm$ in 7-day latency group. In the radiograph taken at 8 weeks after distraction, there was slight bone resorption around the medial and distal edges of the alveolar bone segment, and a new bone deposition was observed in the neighboring alveolar crest area in all groups. Fibrous tissues were present in a part of the buccal cortical bone area of the distraction gap, and the woven and lamellar bones were observed in the distracted gap. There were bony bridges in the distraction gap in all animals examined. These results suggest that optimal time of latency period on alveolar ridge distraction using the intraoral distraction device is about 5 days in dogs, and about 7days in human beings.

  • PDF

Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant (생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성)

  • Chang, Kap-Sung;Kim, Heung-Joong;Park, Joo-Cheol;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFECTS OF OXIDIZED CELLULOSE COVERAGE ON THE CORTICAL BONY DEFECTS (피질골 골결손부에서 Oxidized Cellulose 피개의 영향에 관한 실험적 연구)

  • Kim, Hoi-Jong;Rim, Jae-Suk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.2
    • /
    • pp.112-126
    • /
    • 1998
  • In dentistry, bony defects can be formed by cyst, tumor, inflammation, trauma and surgery in maxilla and mandible. If the overlying soft tissue invades and preoccupies the jaw bony defects, regenerated bony tissue same as adjacent bone can not replace whole space of the defects, thus preventing osteogenesis from occurring. Guided bone regeneration(GBR) is based on the prevention of overlying soft tissue from entering the bony defect during the initial healing periods. E-polytetrafluoroethylene(e-PTFE) is one of an effective and widely used barrier membrane for GBR, but it has the disadvantages such as surgical removal and high price. To overcome such disadvantages of e-PTFE, many investigators have proposed various absorbable barrier membranes. Inexpensive oxidized cellulose($Surgicel^{(R)}$) membrane was shown to have potential for use as an absorbable barrier membrane for regenerative procedure and it would not require surgical removal. The purpose of this study is to investigate the absorption periods of oxidized cellulose at the implant site and usefulness as a mechanical barrier, preventing the ingrowth of the overlying soft tissue into the bony defects. Two bony defects were made in each tibia of a dog using drill and one defect covered with oxidized cellulose and the other covered with periosteum directly as control. The experimental animals were sacrificed at 1st-7th, 10th, 14th, 21th, 28th day postoperatively, Inspection of the specimens was done to evaluate gross changes. Specimens were examined histopathologically by hematoxylin-eosin and Masson's trichrome staining under light microscope. The results were as follows : 1. There was no significant differences of inflammatory reaction between the experimental and the control group. 2. The resorption of oxidized cellulose was almost completed within 14th day. 3. Histologically, bone formation in the experimental group was somewhat more than that of the control group at 10th, 14th, 21th and 28th day postoperatively. The bone forming pattern of the experimental group was more regular than that of the control group. 4. There was no evidence of soft tissue invasion into the bony defect in the experimental group. In conclusion, oxidized cellulose membrane might be used as an alternative absorbable barrier membrane to prevent overlying soft tissue invasion into the bony defects.

  • PDF

A CLINICAL STUDY OF BIODEGRADABLE PLATES AND SCREWS IN ORAL AND MAXILLOFACIAL SURGERY (구강 악안면 영역의 생체 흡수성 고정판 사용에 관한 임상 연구)

  • Kim, Il-Kyu;Park, Seung-Hoon;Jang, Keum-Soo;Yang, Jung-Eun;Jang, Jae-Won;Sasikala, Balaraman
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.6
    • /
    • pp.451-458
    • /
    • 2009
  • Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.