• 제목/요약/키워드: Corrugated Tubes

검색결과 32건 처리시간 0.033초

Experimental Studies on Heat Transfer in the Annuli with Corrugated Inner Tubes

  • Ahn, Soo-Whan
    • Journal of Mechanical Science and Technology
    • /
    • 제17권8호
    • /
    • pp.1226-1233
    • /
    • 2003
  • Experimental heat transfer data for single-phase water flow in the annuli with corrugated inner tubes are presented. In the annuli with parallel flow, ten different annular arrangements are considered. For water flow rate in 1,700${\gamma}$$\^$*/). As P/e becomes closer to 8 in the range below the radius ratio (${\gamma}$$\^$*/) of 0.5, Nusselt numbers increase. However, Nusselt numbers decrease in the range above the radius ratio (${\gamma}$$\^$*/) of 0.5 because flow reattachment position becomes farther in the narrower clearance.

발전소 수증기 응축기용 전열 촉진관에 대한 연구 (A Study on Enhanced Tubes for Electric Utility Steam Condensers)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.31-41
    • /
    • 2016
  • 본 연구에서는 발전소 응축기를 모사할 수 있는 프로그램을 개발하고 발전소 응축기에 전열 촉진관 적용시 얻을 수 있는 여러 효과에 대하여 검토하였다. 평활관을 촉진관으로 교체한다면, 전열량의 증가에 따른 수증기 응축 온도가 내려가게 되므로 발전소의 효율이 증가하게 된다. 따라서 촉진관을 사용하면 기존 설비를 그대로 두고서도 상당량의 전력 여유도를 확보할 수 있다. 고려된 전열 촉진관은 외경 22.2 mm 티타늄 재질의 코류게이트 관, 리브 조도 낮은 핀관, 삼차원 조도 낮은 핀관이다. 내측 조도의 경우 최적 조도 높이가 존재하였다. 또한 삼차원 조도 낮은 핀관이 다른 두 형상보다 우수하게 나타났다. 삼차원 조도의 경우 원주 방향으로 인접한 딤플 사이에서 흐름 방향으로 선회류가 유발되고 이 선회류에 의하여 열전달이 촉진되기 때문이다. 600 MW 발전소 응축기에 전열 촉진관을 적용하면 0.5 MW~1.3 MW 가량의 추가 전력을 생산할 수 있다. 또한 냉각수 온도가 올라가면 추가 전력도 증가한다. 실제로 발전소 응축기에 적용하기 위해서는 열 성능 외에도 화울링, 부식, 기계적 특성 등이 고려되어야 한다.

소구경 전열관 내의 열전달촉진 형상변화에 따른 열전달 및 압력강하 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of the Heat Transfer and the Pressure Drop inside the Small Diameter Tube with the Heat Transfer Enhancing Geometry)

  • 박찬우;진성민;정종수
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.297-303
    • /
    • 2006
  • Friction and heat transfer coefficients were measured inside the corrugated tube using water as the working fluid. The test is performed for 16 tubes which outer diameter of tubes are 12.7 mm. These specifications are 4 indentation depths and 4 indentation pitches, respectively. The range of the water velocity inside the tube is from 0.5 to 3.0 m/s (8,500

가공관의 외벽에서 친수성 표면처리가 증발열전달에 미치는 영향 (Effects of Hydrophilic Surface Treatment on Evaporation Heat Transfer at the Outside Wall of Enhanced Tubes)

  • 박노성;황규대;김호영;강병하;정진택
    • 대한기계학회논문집B
    • /
    • 제25권5호
    • /
    • pp.666-672
    • /
    • 2001
  • Experiments have been carried out to investigate the evaporation heat transfer characteristics of various tubes on which hydrophilic surface treatment using plasma was employed. Spiral, corrugated and low-finned tubes were selected as test tubes. The evaporator tubes were bundled to form three rows of tubes connected in series, with each row being 400mm long. The results obtained indicate that hydrophilic treated tubes tested exhibit better evaporation heat transfer performance as compared with untreated tubes. It is found that the high wettability of the surface obtained through hydrophilic treatment induces film flow onto the tubes during the evaporation process, while sessile drops are formed on untreated tubes.

주름관에서의 압력강하와 마찰손실 계측에 관한 연구 (The study on the measurement for the pressure drop and friction factor of corrugated metal pipes)

  • 윤영선;강준원;유재석;김현정
    • 한국가시화정보학회지
    • /
    • 제4권2호
    • /
    • pp.76-80
    • /
    • 2006
  • The data for friction factor of the pipe correlated by Reynolds number and relative roughness have been reported well as a Moody chart. However, the results for corrugated shapes have been not investigated sufficiently. In this research, therefore, the pressure drop and friction factor are obtained. Flexible metal tubes with corrugations for the measurement are made of stainless steel plates. The kinds of tubes for the measurement are 5 annular types and helical types. The pressure drop & the velocity of the flow are obtained by micromanometer & digital pressure sensor, supplying dry air at several steps. Then the pressure drop is calculated for each tube, using the obtained data. The result shows that the pressure drop is strongly influenced by the viscous dissipation of kinetic energy due to the circulation of flows, rather than a viscous friction loss. The pressure drop increased consistently as the Reynolds number increases.

  • PDF

공냉식 수직 흡수기의 열전달에 미치는 계면활성제의 영향 (Influence of surfactant on heat transfer of air-cooled vertical absorber)

  • 윤정인;권오경;문춘근
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.740-748
    • /
    • 1999
  • This research was concerned with the enhancement of heat transfer by surfactant added to the aqueous solution of LiBr. Different vertical tubes were tested with and without an additive of normal octyl alcohol. The test tubes were a bare inner surface, groove inner surface, corrugated inner surface and spring inserted inner surface tubes. The additive concentration was about 0.08 mass%. The heat transfer coefficient was measured as a function of film Reynolds number in the range of 20~200. Experiments were tarried out at higher cooling water temperature of $35^{\circ}C$ to simulate an air cooling condition for several kinds of absorber testing tubes. The experimental results were compared with cases without surfactant. The enhancement of heat transfer by Marangoni convection effect which was generated by addition of the surfactant is observed in each test tube. Especially, it is clarified that the tube with an inserted spring has the highest enhancement effect.

  • PDF

파형강관을 삽입한 중공원형단면 철근콘크리트 부재의 거동에 관한 연구 (Behavior of Circular Hollow Section R.C Member with Internal Corrugated Steel Tube)

  • 임정순;김성칠;조재병;이수근
    • 한국방재학회 논문집
    • /
    • 제3권1호
    • /
    • pp.123-131
    • /
    • 2003
  • 파형강관을 삽입하여 보강된 중공원형단면의 역학적 거동을 연구하기 위하여 직경 50cm, 길이 340cm의 시험체를 제작하였고, 3점 휨시험을 수행하였다. 하중재하는 파괴 또는 최대한변형이 발생할 때까지 느리게 증가시켰다. 시험하는 동안에 시험체 중앙의 휨방향 변위와 인장측과 압축측의 종방향 변위를 측정하였다. 측정데이타를 분석한 결과를 파형강관이 삽입되지 않은 등가단면에 대한 해석결과와 비교하였다. 비교결과, 중공 철근콘크리트 부재의 휨강성과 연성이 파형강관을 내부에 삽입함으로써 크게 향상시킬 수 있는 것으로 나타났다.

가스용 금속 플렉시블 호스의 용접방법 개선에 관한 연구 (An Improvement of Welding Method for the Corrugated Stainless Steel Tubing(CSST))

  • 김완진;이영섭;최진림
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.79-83
    • /
    • 2008
  • The corrugated stainless steel tubing(CSST) for the fuel gas piping system can be installed easily and quickly. It is often constructed under the ceiling and the wall which has a good flexibility and installation in comparison with iron pipe. However, the quality of the CSST is determined to depend upon the welding skill of stainless steel tubing. In this study, it is tested by controlling jet point of Ar as inert and cooling gas, and also compared with the bead state of welding point and the performance. As a result, it has the best condition when the jet point of Ar is located behind $5{\sim}10mm$ of the welding point.

Study on Pressure drop characteristics in HTS cable core with two flow passages

  • Lee, Jun-Kyoung;Kim, Seok-Ho;Kim, Hae-Joon;Cho, Jeon-Wook
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권4호
    • /
    • pp.33-37
    • /
    • 2008
  • The main objective of this study is to identify the pressure drop characteristics of coolant flow passages of 154kV/1GVA High Temperature Superconducting (HTS) power cable, experimentally. The passages were consisted of two parts, the one is the circular path with spiral ribs in the core to cool the cable conductor layer and the other is annular path with spirally corrugated outer wall to cool the shield layer. Thus the experiments to acquire the pressure drop data were performed with two types of circular spiral tubes and eight types of the concentric annuli in various range of Reynolds number. The pressure drops in the core tubes and the annuli were much higher than those in the tubes with smooth surface. Therefore, modified correlations to present the experimental results in each flow passage were suggested.

Enhancement of Heat and Mass Transfer by Insert Spring in a Vertical Absorber with Surfactant

  • Yoon, Jung-In;Choi, Kwang-Hwan;Moon, Choon-Geun;Sarker M.M.A;Kwon, Oh-Kyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권8호
    • /
    • pp.1239-1250
    • /
    • 2004
  • This research was concerned with the enhancement of heat transfer by surfactant added to the aqueous solution of LiBr. Different vertical tubes were tested with and without an additive of normal octyl alcohol. The test tubes are a bare inner surface. a groove inner surface, a corrugated inner surface and a spring inserted inner surface tubes. The additive concentration was about 0.08 mass%. The heat transfer coefficient was measured as a function of the film Reynolds number in the range of 20~200. Experiments were carried out at higher cooling water temperature of $35^{\circ}C$ to simulate an air cooling condition for several kinds of absorber testing tubes. The experimental results were compared with and without surfactant. The enhancement of heat transfer by Marangoni convection effect which was generated by addition of the surfactant is observed in each test tube. Especially, it is clarified that the tube with an inserted spring has the highest enhancement effect.