• 제목/요약/키워드: Corrosive

검색결과 718건 처리시간 0.024초

해양환경 중 음극전류 프로세스에 의해 강판에 형성된 석회질 피막의 특성 분석 (The Characteristic Analysis of Calcareous Deposit Films Formed on Steel Plate by Cathodic Current Process in Marine Environment)

  • 박준무;강재욱;최인혜;이승효;문경만;이명훈
    • 한국표면공학회지
    • /
    • 제49권2호
    • /
    • pp.166-171
    • /
    • 2016
  • Cathodic protection is widely recognized as the most cost effective and technically appropriate corrosion prevention methodology for the port, offshore structures, ships. When applying the cathodic protection method to metal facilities in seawater, on the surface of the metal facilities a compound of calcium carbonate($CaCO_3$) or magnesium hydroxide($Mg(OH)_2$) films are formed by $Ca^{2+}$ and $Mg^{2+}$ ions among the many ionic components dissolving in the seawater. And calcareous deposit films such as $CaCO_3$ and $Mg(OH)_2$ etc. are formed by the surface of the steel product. These calcareous deposit film functions as a barrier against the corrosive environment, leading to a decrease in current demand. On the other hand, the general calcareous deposit film is a compound like ceramics. Therefore, there may be some problems such as weaker adhesive power and the longer time of film formation uniting with the base metal. In this study, we tried to determine and control the optimal condition through applying the principle of cathodic current process to form calcareous deposit film of uniform and compact on steel plate. The quantity of precipitates was analyzed, and both the morphology, component and crystal structure were analyzed as well through SEM, EDS and XRD. And based on the previous analysis, it was elucidated mechanism of calcareous deposit film formed in the sacrificial anode type (Al, Zn) and current density (1, 3, $5A/m^2$) conditions. In addition, the taping test was performed to evaluate the adhesion.

1.25Cr-0.5Mo강을 이용한 합성가스 조성 변화에 따른 SNG 1차반응기의 부식특성에 관한 실험적 연구 (Experimental Study on Corrosion Characteristics of 1.25Cr-0.5Mo in the 1st-mathanator reactor for Synthetic Natural Gas according to Gas Compositions)

  • 김진현;조홍현
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.709-716
    • /
    • 2016
  • 최근 급속한 플랜트 설비의 발전과 더불어 각종 기계 구조물들의 운전조건이 가혹해지고 사용시간이 길어짐에 따라 신뢰성에 대한 문제가 제기되고 있다. 특히, SNG 설비에 사용되는 재료는 설계조건에 따라 1.25Cr-0.5Mo 또는 2.25Cr-1Mo강과 같은 내열강들이 주로 사용된다. 본 연구에서는 Lab-scale용 합성천연가스 반응기를 제작하여 생산공정 반응기 재질인 1.25Cr-0.5Mo강을 이용하여 실제 SNG 공정중 1차반응기와 동일한 운전 조건에서 부식 특성에 대하여 실험적 연구를 진행하였다. 1.25Cr-0.5Mo강을 운전 시간에 따라 각각 배출조성 조건과 주입조성 조건에 노출시켜 부식에 대한 실험을 수행하였으며 실험 결과 내구성에 가장 영향을 미치는 요소는 수소로 인한 수소취성과 산화 부식임을 알 수 있었으며, 배출조성보다 주입조성에서 더 빠른 부식이 발생함을 확인하였다. 그러나 배출조성 조건에서는 산화부식과 더불어 수소취성에 의한 부식이 동시에 발생하여 장시간 운전 후 부식정도가 갑자기 증가하고 부식강도가 급격히 강해지는 것을 나타났다. 또한 주입조성에서는 산화물들이 시편에 흡착되어 두꺼운 산화층을 형성시켰으며 이로 인하여 재료의 내산화성이 크게 저하되는 것으로 확인되었다.

HT-60강 용접부의 SCC및 AE신호특성에 관한 연구 (Study on Characteristics of SCC and AE Signals for Weld HAZ of HT-60 Steel)

  • 나의균;유효선;김훈
    • 비파괴검사학회지
    • /
    • 제21권1호
    • /
    • pp.62-68
    • /
    • 2001
  • 인공해수에서 HT-60강 용접부의 응력부식균열(SCC)과 음향방출(AE)신호특성을 알아보기 위하여 SCC외 AE실험을 동시에 실시하였으며, 양 실험결과를 상호 비교 분석하였다. 모재의 경우, -0.8V에서 보다 긴 파단수명을 보였고, 용해기구 등으로 인하여 -0.8V에 비해 -0.5V에서 AE가 많이 발생하였다. 그러나 시험편에 가해진 전위 값에 관계없이 최대하중 이후의 영역에서 AE 발생 수는 감소하였다. 용접재의 경우, 모재 및 후열처리재와는 달리 용접부의 특이성 때문에 많은 AE 발생과 큰 진폭의 범위$(40{\sim}100dB)$를 나타내었으며 최대하중 이후에도 AE 발생이 활발하였다. 또한, 보다 크고 많은 균열이 파단면에 형성되었음을 SEM관찰을 통하여 관찰할 수 있었으며, 이들 결과로부터 용접부는 인공해수에서 SCC현상이 가장 심하게 일어나고 있음을 확인할 수 있었다. 후열처리는 용접부의 연화를 초래하였고, 용접재에 비해 부식환경에 대한 민감도를 떨어뜨리는 효과를 가져왔다.

  • PDF

음향방출법에 의한 고 장력강 용접부의 부식손상 특성 평가 (Characterization of Stress Corrosion Cracking at the Welded Region of High Strength Steel using Acoustic Emission Method)

  • 나의균;김훈
    • 비파괴검사학회지
    • /
    • 제23권3호
    • /
    • pp.212-219
    • /
    • 2003
  • 본 연구의 목적은 음향방출법을 이용하여 고 장력강 용접부의 응력부식균열특성을 평가하는데 있다. 이를 위해 용접재와 후열처리재를 대상으로 인공해수에서 저 변형률로 하중을 가하면서 응력부식균열을 일으키고, 동시에 음향방출법에 의해 손상과정을 감시하였다. 부식환경은 전위계에 의해 제어되었으며, 시험편에는 각각 -0.8V와 -1.1V의 전위 값을 가하였다. -0.8V인 부식환경 하에서 일층 용접부는 후열처리재에 비해 단위 시간당 AE counts수가 훨씬 많이 발생하였으며, 응력부식균열과정에서 균열의 발생 및 합체가 가장 활발하게 이뤄지고 있음을 누적 AE counts의 결과로부터 확인할 수 있었다. 가해진 전위 값이 -1.1V인 경우, 일층 용접재의 파단시간은 이층 용접재에 비해 줄었고, AE counts수는 이층 용접재에 비해 현저히 많이 발생하였다 AE진폭 범위는 -0.8V 일층 용접재에서 가장 높았고, -1.1V 일층 용접재에서 가장 작은 값을 보였는데, fractography분석결과 AE 진폭 범위는 균열의 크기 및 폭과 밀접한 관계가 있음을 알 수 있었다.

모르타르(W/C:0.6)의 철근의 부식전위와 양극분극 및 임피던스 특성에 미치는 재령 년수 (Effect of Period of Immersion on Corrosion Potential, Anodic Polarization, and Impedance Characteristics of Reinforced Steel in Mortar (W/C: 0.6))

  • 정재현;문경만;이성열;이명훈;백태실
    • 한국해양공학회지
    • /
    • 제30권4호
    • /
    • pp.327-333
    • /
    • 2016
  • Reinforced concrete structures have found wide usage in land and maritime applications. However, the corrosion of reinforced concrete has been recognized as a serious problem from economic and safety standpoints. In previous studies, the corrosion behavior of the inner steel bar embedded in mortar (W/C: 0.4, 0.5) was investigated using electrochemical methods. In this study, multiple mortar test specimens (W/C: 0.6) with six different cover thicknesses were prepared and immersed in flowing seawater for five years. Subsequently, equations related to the cover thickness, period of immersion, and corrosion characteristics of the embedded steel bar were evaluated using electrochemical methods. Prior to immersion, the corrosion potentials indicated an increase with increasing cover thickness, and after five years, all corrosion potentials demonstrated a trend in the positive direction irrespective of the cover thickness. However, the relationships between the corrosion potential and cover thickness were not in complete agreement. Furthermore, after five years, all of the corrosion potentials indicated values that were nobler compared to those obtained prior to immersion, and their corrosion current densities also decreased compared to their values obtained prior to immersion. It was considered that the embedded steel bar was easily corroded because of the aggression of water, dissolved oxygen, and chloride ions; a higher W/C ratio also assisted the corrosion process. The corrosive products deposited on the surface of the steel bar for five years cast a resistance polarizing effect shifting the corrosion potential in the nobler direction. Consequently, it was considered that the W/C ratio of 0.6 showed nearly same results as those of W/C of 0.4 and 0.5. Therefore, the corrosion potential as well as various parameters such as the cover thickness, period of immersion, and W/C ratio must be considered at once for a more accurate evaluation of the corrosion property of reinforced steel exposed to marine environment for a long period.

CMIT/MIT 함유 가습기 살균제 제품의 제조 및 판매기업 형사판결 1심 재판 판결문에 대한 과학적 고찰 (I) - 제품 위험성과 노출평가 측면에서 (A Scientific Critique of a Korean Court's Acquittal for Involuntary Manslaughter Related to 5-chloro-2-methylisothiazol-3(2H)-one/2-methylisothiazol-3(2H)-one (CMIT/MIT), a Humidifier Disinfectant (HD) Part I: Material safety, exposure and delivery to target organ from an HD perspective)

  • 박동욱;조경이;김지원;최상준;권정환;전형배;김성균
    • 한국환경보건학회지
    • /
    • 제47권2호
    • /
    • pp.111-122
    • /
    • 2021
  • Objectives: There was a judgment of acquittal for the manufacturer SK Chemical and the vendor Aekyung regarding humidifier disinfectant (HD) containing 5-chloro-2-methylisothiazol-3(2H)-one/2-methylisothiazol-3(2H)-one (CMIT/MIT). The rationale used in this judgement is discussed here in the light of scientific consideration. Methods: The sentencing document for the judgements was obtained from the Korea Supreme Court Service. In particular, the judgements made by the court related to the risk of HD and external and internal exposure to CMIT/MIT are discussed based on scientific evidence. Results: Rendering a determination in a criminal trial of insufficient evidence of causation, the court dismissed the prosecution's motion that humidifier disinfectant-associated lung injuries (HDLI) and asthma were associated with the utilization of these products. However, CMIT/MIT, a strong sensitizing and corrosive substance, has been reported to be associated with brain toxicity, allergic contact dermatitis, and asthma. Furthermore, the judgment did not consider total consumption amounts or the cumulative dose of CMIT/MIT in the humidifier. Lastly, there are several cases supporting the fact that exposure to water-soluble substances including CMIT/MIT can cause lower respiratory tract diseases. In addition to cases of asthma among the workers exposed to CMIT/MIT, we identified lung injury victims who were exposed to HDs exclusively containing CMIT/MIT. Conclusions: We conclude that there is sufficient evidence supporting the assertion that HDs containing CMIT/MIT cause lung injuries, including asthma, contrary to the court's judgement.

성인 단장증후군 환자의 다학제 장 재활: 국내 단일 기관 다학제 장재활 클리닉의 경험 (Multidisciplinary Intestinal Rehabilitation for Short Bowel Syndrome in Adults: Results in a Korean Intestinal Rehabilitation Team)

  • 윤소정;이상훈;박효정;김현정;윤지혜;민자경;서정민
    • Journal of Clinical Nutrition
    • /
    • 제10권2호
    • /
    • pp.45-50
    • /
    • 2018
  • Purpose: Intense multidisciplinary team effort is required for the intestinal rehabilitation of patients afflicted with the short bowel syndrome (SBS). These include enteral and parenteral nutrition (PN) support, monitoring of complications related to treatment, and considering further medical or surgical options for intestinal adaptation. Methods: In the Intestinal Rehabilitation Team (IRT) at the Samsung Medical Center, we have experienced 20 cases of adult SBS requiring multidisciplinary intestinal rehabilitation. This study is a retrospective review of the collected medical records. Results: Of the 20 subjects treated, 12 patients were male and 8 patients were female. At the time of referral to the IRT, the mean age was 51.5 years, and the mean body weight was 50.1 kg, which was 90% of the usual body weight. The diseases or operative managements preceding massive bowel resection were malignancy in 11 cases, cardiac surgery in 2 cases, trauma in 2 cases and one case, each of tuberculosis, corrosive esophagitis, atrial fibrillation, simultaneous pancreas and kidney transplantation, and perforated appendicitis. Of these, there were 14 survivals and 6 mortalities. The fatalities were attributed to progression of disease, intestinal failure-associated liver disease, and sepsis (unrelated to intestinal failure) (2 cases each). Among the 14 surviving patients, 8 patients have been weaned off PN, whereas 6 are still dependent on PN (mean PN dependence 36%). Conclusion: This paper reports the results of multidisciplinary intestinal rehabilitation of adult short bowel patients treated at the Samsung Medical Center. Further studies are required to improve survival and enteral tolerance of these patients.

부식촉진 실험을 통한 대기환경에서 신설 도장계의 노화곡선 제안 (Suggestion of Deterioration Curve for New-type Coating on Atmospheric Environment by Acceleration Corrosion Test)

  • 정영수;김민정;전석현;안진희;김인태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권2호
    • /
    • pp.75-83
    • /
    • 2019
  • 본 연구에서는 국내에서 사용되고 있는 우레탄계, 세라믹계, 폴리실록산계 및 불소수지계 강교량용 도장계를 대상으로 실내 부식실험을 실시하여 도장계별 노화모델을 도출하였다. 상도를 구분하여 각 도장계별로 시험편을 제작하였으며, 직경 0.5, 1, 3, 5 mm의 원형 결함을 도입하였다. ISO 20340를 이용하여 극한환경을 모사한 부식촉진실험을 실시하였다. 도장계별 노화곡선은 원형결함의 노화면적을 기준으로 평가되었다. 노화곡선을 사용하여 공용중인 강교의 도장 사용수명을 평가하기 위하여 촉진배율을 산출하였으며, 촉진배율은 ISO 20340과 ISO 9223의 대기환경 부식속도를 기준으로 산출되었다. 실험결과, 노화진전속도는 원형결함의 크기와 상관없이 증가하였으며, 노화면적이 3%일 때 우레탄 도장계의 노화수명은 C2, C3, C4 및 C5 등급에서 약 31.8, 15.8, 9.9 및 3.9년으로 평가되었다.

수처리시설용 콘크리트의 금속용사 피막 종류에 따른 내오존성 및 전기화학적 방식 성능 평가 (Evaluation of Ozone Resistance and Anti-Corrosion Performance of Water Treatment Concrete according to Types of Metal Spray Coating)

  • 박진호;최현준;이한승;김상열;장현오
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권4호
    • /
    • pp.61-68
    • /
    • 2019
  • 산업화, 도시화로 인해 수자원의 오염이 악화 되면서 기존에 염소를 이용한 정수처리 방법으로는 깨끗한 물을 공급하는데 어려운 실정이다. 이에 오존을 이용한 고도정수 처리 시설의 도입이 증가하고 있다. 그러나 기존의 방수 방식 공법으로 사용되는 에폭시계 방수 방식제 및 스테인리스는 오존의 강력한 산화력으로 인해 열화되어 박리 등 문제 발생하였으며, 콘크리트까지 영향을 미쳐 내구성 저하의 원인이 된다. 이에 따라 본 연구에서는 내오존성 및 내화학성이 뛰어난 금속 패널을 기존의 시공법 보다 손쉬운 방법으로 시공하기 위한 방법으로 금속 용사 공법을 이용하여 수처리 시설 콘크리트 구조물의 열화를 원천적으로 방지하기 위한 마감공법 개발 연구의 일원으로 용사금속 종류 에 따른 내오존성 평가를 실시하였으며, 실제 하수처리장 환경에서의 전기화학적 안정성능 평가를 실시하였다. 실험결과 용사금속 Ti이 용사 후에도 내오존성이 뛰어난 것으로 나타났으며, 하수처리장 환경에서의 전기화학적 안정성능 평가 결과 용사금속 Ti가 $403.83k{\cdot}{\Omega}{\cdot}cm^2$의 가장 높은 분극저항을 나타남으로써 높은 수준의 내구성을 확보하는 것을 확인할 수 있었다.

캐비테이션 발생에 따른 해군 수상함정 방청도료(EH 2350) 적합성 검증에 관한 연구 (A Study on the Anti-Corrosion Paint(EH 2350) Compatibility Verification for Naval Surface Vessels's Cavitation)

  • 최상민;이지혁;백용관;정현섭
    • 한국산학기술학회논문지
    • /
    • 제20권5호
    • /
    • pp.7-12
    • /
    • 2019
  • 군의 수상함정은 다수 해역에서 작전 업무 수행을 실시하며, 부식이 되기 쉬운 가혹한 환경에 노출되어 있다. 해군 운용 함정들은 부식을 방지하기 위하여 여러 가지 방법의 방식 기술을 적용하고 있으나, 캐비테이션에 의한 선저구조물에 부식 및 손상이 지속적으로 발생한다. 선체의 부식은 함 작전운용성능 저하 및 함 수명에 직접적인 영향을 미칠 수 있는 요소로서 함정 선체의 방식은 반드시 필요하다. 본 연구에서는 해군에서 운용중인 함형별로 사용하는 방청도료 자료를 수집 및 분석하여, 그 중 주 방청도료로 사용하고 있는 EH 2350과 미 해군에서 선저 구조물 보호를 위하여 사용하고 있는 특수도료인 금속보수제 DuraTough DL과 특성 비교 및 내마모성 시험을 통해 적합성 검증을 실시하였다. 객관적인 검증을 위하여 함이 해수 환경에 노출된 것으로 고려하여 마모 cycle과 마모 하중 조건을 다수 설정하여 검증을 실시하였다. 본 연구를 통하여 해군 수상함정에 일반적으로 적용되는 방청도료(EH 2350)의 적합성에 대한 신뢰성을 확보할 수 있을 것이다.