• 제목/요약/키워드: Corrosion accelerated test

검색결과 221건 처리시간 0.144초

원전감육배관 UT 두께측정 결과의 신뢰도 평가를 위한 다자비교시험 (Round Robin Test for Reliability Evaluation of Ultrasonic Thickness Measurement Results in Nuclear Power Plant Pipelines)

  • 이승준;이원근;이준현;이성호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1702-1707
    • /
    • 2007
  • The reduction of pipe-thickness induced by flow accelerated corrosion (FAC) is one of the most serious problems on the maintenance of piping system in nuclear power plants (NNP). If the thickness of a pipe component is reduced below the critical level, it cannot sustain pressure and consequently results in leakage or rupture. For this reason, wall thinning by FAC has been inspected in secondary side piping systems in NPPs. In this research Round Robin Test (RRT) was conducted to verify confidence of wall thinning measurement system in NPP. 12 inspectors from 3 companies participated and 23 specimens were used according to standard practice in RRT. The gage R&R analysis was introduced in regard to repeatability and reproducibility that are affected to measurement system errors. Confidence intervals of thickness measurement system were obtained.

  • PDF

화상처리 기법과 전기화학적 임피던스 분광법을 이용한 강교 도장용 에폭시 하도 도료의 열화 평가 (Evaluation of Deterioration of Epoxy Primer for Steel Bridge Coating using Image Processing and Electrochemical Impedance Spectroscopy)

  • 이찬영;이상훈;박진환
    • Corrosion Science and Technology
    • /
    • 제8권2호
    • /
    • pp.53-61
    • /
    • 2009
  • 본 연구에서는 강교 도장재료로 사용될 수 있는 에폭시 하도 도료를 도포한 시험편을 촉진시험을 통해 열화시킨 후 도막의 외관 평가 및 EIS에 의한 평가를 실시하고, 그 2가지 방법에 대한 비교 분석을 실시하였다. 화상처리 기법에 의해 구한 총 열화 면적율과 열화도 평점 산정 결과를 상호 비교해 본 결과 녹이 발생한 경우가 그렇지 않은 경우보다 열화도 평점이 높게 나타났다. 이는 강교 도장의 열화도 평가 기준에서 단위 열화 면적율당 부여하는 열화도 평점이 박리의 경우보다 녹의 경우가 더 크기 때문이다. 열화 면적율과 EIS 측정 데이터를 비교해 본 결과 녹의 면적율 약 0.1% 이상, 블리스터링의 면적율 약 3% 이상만 되어도 도막의 임피던스는 약 $10^4{\Omega}{\cdot}cm^2$ 혹은 그 이하로 크게 저하되었다. 2개의 시험편을 제외한 모든 시험편에 대해 전하전달저항(charge transfer resistance, $R_{ct}$)과 이중층 정전용량(double layer capacitance, $C_{dl}$) 값이 나타났으며, 이 결과로부터 이들 시험편들은 도막과 강재 계면에 수분이 축적되어 부식이 진행되고 있음을 알 수 있었다. 열화도 평점과 EIS 측정결과를 상호 비교해 본 결과 저주파수(10 mHz)에서의 임피던스 값이 $10^6{\Omega}{\cdot}cm^2$ 이하로 떨어진 경우는 모두 열화도 평점이 10점 이상으로 나타났으며, NORSOK cyclic test 과정에 의해 열화시킨 경우 열화도 평점이 높지 않음에도 불구하고 임피던스는 가장 낮게 나타났다. 이것은 도장계와 열화조건이 주 시험편과 다르기 때문인 것으로 판단되며, 열화조건이 더 가혹하거나 복합적일 경우 외관 상태에 비해 도막의 저항이 더 크게 저하될 가능성이 있다고 생각된다.

하이볼륨 플라이애시 콘크리트의 철근부식 저항성 및 임계 염화물량 (Resistance to Corrosion of Reinforcing Steel and Critical Chloride Content of High Volume Fly Ash Concrete)

  • 이현진;배수호;정상화
    • 한국건설순환자원학회논문집
    • /
    • 제5권4호
    • /
    • pp.375-381
    • /
    • 2017
  • 최근, 친환경 콘크리트에 대한 관심의 증가로, 플라이애시, 고로슬래그 미분말 및 실리카 퓸 등의 산업부산물을 혼입한 콘크리트의 사용이 증가되고 있다. 특히 이 같은 산업부산물은 콘크리트 내의 철근부식 저항성을 증가시키고 염화물이온 침투를 감소시키는 것으로 잘 알려져 있다. 이 실험연구의 목적은 시멘트량의 약 50%를 플라이애시로 치환한 하이볼륨 플라이애시 콘크리트(HVFAC)의 철근부식 저항성 및 임계 염화물량을 평가하는 것이다. 이를 위하여 철근 상부를 노출시킨 원주형 공시체의 철근부식 개시 시기를 추정하기 위하여 자연전위 측정에 의한 철근부식 모니터링을 수행하였다. 결론적으로, HVFAC의 철근부식 개시 시기는 플레인 콘크리트보다 1.2~1.3배 증가하여 철근부식 저항성이 우수한 것으로 나타났고, 플레인 콘크리트 및 HVFAC의 임계 염화물량은 각각 $0.80{\sim}1.20kg/m^3$, $0.89{\sim}1.60kg/m^3$으로 나타나, HVFAC가 플레인 콘크리트보다 1.1~1.3배 증가하는 것으로 나타났다.

콘크리트 특성에 따른 반전위 측정값의 변화와 부식제어 조건 (Variation of Half Cell Potential Measurement in Concrete with Different Properties and Anti-Corrosive Condition)

  • 김기범;박기태;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권6호
    • /
    • pp.95-103
    • /
    • 2013
  • 비파괴 기법중 반전위 측정법은 부식가능성을 정량적으로 판별할 수 있으므로 꾸준하게 사용되고 있다. 본 연구에서는 피복두께를 10, 30, 60mm, 물-시멘트비를 0.35, 0.55, 0.70으로 변화시킨 RC 시편을 대상으로 비말대 지역을 모사한 촉진염해분무실험을 수행하였다. 45일간의 촉진 염해 분무시험을 수행한 뒤, RC 시편에 대하여 반전위값을 측정하였다. w/c 0.55 조건에서 피복두께가 10mm인 RC 시편은 부식이 발생하였으며, w/c 0.7인 경우 피복두께 30mm인 시편에서도 부식이 발생하였다. 실험결과를 이용하여 물-시멘트비와 피복두께를 변수로 하는 반전위 평가식을 제안하였으며, 비말대지역에서 부식을 억제할 수 있는 조건을 도출하였다. 또한 Life 365 프로그램을 이용하여 비부식 조건의 w/c와 피복두께를 분석하였으며, 본 연구의 결과인 반전위 측정값과 비교하였다.

Deterioration of tensile behavior of concrete exposed to artificial acid rain environment

  • Fan, Y.F.;Hu, Z.Q.;Luan, H.Y.
    • Interaction and multiscale mechanics
    • /
    • 제5권1호
    • /
    • pp.41-56
    • /
    • 2012
  • This study is focused on evaluation of the tensile properties of concrete exposed to acid rain environment. Acid rain environment was simulated by the mixture of sulfate and nitric acid in the laboratory. The dumbell-shaped concrete specimens were submerged in pure water and acid solution for accelerated conditioning. Weighing, tensile test, CT, SEM/EDS test and microanalysis were performed on the specimens. Tensile characteristics of the damaged concrete are obtained quantitatively. Evolution characteristics of the voids, micro cracks, chemical compounds, elemental distribution and contents in the concrete are examined. The deterioration mechanisms of concrete exposed to acid rain are well elucidated.

온도측정에 의한 히트파이프의 수명예측 (Prediction of Life of Heat Pipes by Measuring Temperature Distribution)

  • 신흥태;;이윤표
    • 대한기계학회논문집B
    • /
    • 제23권7호
    • /
    • pp.856-863
    • /
    • 1999
  • The thermal performance degradation of heat pipes is caused by the non-condensable gas generation mainly due to the electrochemical corrosion which results from the reaction of working fluids with tube materials. In this study, a simplified method described below was proposed to estimate the life of heat pipes concerning the non-condensable gas generation. The temperature distributions at the outer surface of heat pipes was measured, and based on them the amount of non-condensable gas of hydrogen was estimated. Applying it to the Arrhenius model, the mass generation of hydrogen and the volume occupied by the gas In heat pipes could be estimated for an operating temperature and time. Moreover, this simplified method was applied to the accelerated life test of nine methanol-stainless steel heat pipe samples.

자동차 엔진부품용 Shaft에 플라즈마 산질화기술 적용 (The Application of Plasma Nitrocarburizing and Plasma Post Oxidation Technology to the Automobile Engine Parts Shafts)

  • 전은갑;박익민;이인섭
    • 한국재료학회지
    • /
    • 제16권11호
    • /
    • pp.681-686
    • /
    • 2006
  • Plasma nitrocarburising and plasma post oxidation were performed to improve the wear and corrosion resistance of S45C and SCM440 steel by a plasma ion nitriding system. Plasma nitrocarburizing was conducted for 3h at $570^{\circ}C$ in the nitrogen, hydrogen and methane atmosphere to produce the ${\varepsilon}-Fe_{2-3}$(N, C) phase. Plasma post oxidation was performed on the nitrocarburized samples with various oxygen/hydrogen ratio at constant temperature of $500^{\circ}C$ for 1 hour. The very thin magnetite ($Fe_3O_4$) layer $1-2{\mu}m$ in thickness on top of the $15{\sim}25{\mu}m$ ${\varepsilon}-Fe_{2-3}$(N, C) compound layer was obtained by plasma post oxidation. A salt spray test and electrochemical testing revealed that in the tested 5% NaCl solution, the corrosion characteristics of the nitrocarburized compound layer could be further improved by the application of the superficial magnetite layer. Throttle valve shafts were treated under optimum plasma processing conditions. Accelerated life time test results, using throttle body assembled with shaft treated by plasma nitrocarburising and post oxidation, showed that plasma nitrocarburizing and plasma post oxidation processes could be a viable technology in the very near future which can replace $Cr^{6+}$ plating.

활성화된 플라이애쉬 혼입콘크리트의 철근부식거동에 관한 전기화학적 연구 (Electrochemical Studies on the Corrosion Performance of Steel Embeded in Activated Fly Ash Blended Concrete)

  • 송하원;이창홍;이근주;벨루사라스와티
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.97-108
    • /
    • 2008
  • 시멘트 대체 재료로서 플라이애쉬의 사용은 시멘트 생산비용을 절감시키는 효과를 창출하였다. 반면에 플라이애쉬 혼입콘크리트는 OPC에 비해 상대적으로 긴 양생시간과 초기강도의 발현 저하를 들 수 있어 이의 해결을 위해 물리적 방법, 온도 및 화학적 방법 등과 같은 다양한 활성화 기술의 적용을 통하여 플라이애쉬 혼입 콘크리트의 수화를 가속시킬 수 있고, 콘크리트의 부식 저항성을 향상시킬 수가 있다. 본 연구에서는 10~40%의 치환률을 가진 활성화된 플라이애쉬 시편을 통해 개방 회로형 전위측정(Open circuit potential measurement)을 수행하였고, 투수시험, 급속염화물침투시험 및 SEM(Scanning electron microscopy)촬영을 통해 OPC 콘크리트와 비교 분석 하였다. 또한, 치환률의 임계범위 20~30%의 경우에 있어서 활성화된 플라이애쉬를 사용한 콘크리트가 열화저항성에 있어서 개선효과가 나타나고 있음을 확인하였다. 또한 플라이애쉬를 화학적으로 활성화시킨 경우가 본 연구에서 수행된 다른 활성화 방법들에 비해 더욱 좋은 결과를 나타나고 있음도 확인하였다.

전기화학적 임피던스법을 이용한 염함유 시멘트 모르터내의 철근부식 연구 (Electrochemical Impedance Study on the Rebar Corrosion in Cement Mortar Containing Chloride Ions)

  • 남상철;백지흠;조원일;조병원;윤경석;전해수
    • 공업화학
    • /
    • 제9권6호
    • /
    • pp.811-816
    • /
    • 1998
  • 염분을 함유한 시멘트 모르터 내의 철근의 부식현상을 교류 임피던스법에 의해 고찰하였다. 부식 가속화 장치를 이용하여 단기간 내에 부식현상을 예측하였으며, 측정된 임피던스 값은 제안된 전기화학적 등가회로 및 모델에 적용할 수 있었으며, CNLS(complex nonlinear least squares) fitting법에 의하여 계산된 값과 실험에서 얻은 값이 잘 일치함을 알 수 있었다. 주어진 모델로부터 구한 전하이동저항 (charge transfer resistance, $R_2$)은 염분 농도와 시간에 따른 철근의 무게 감소량의 예측을 가능하게 하였으며, 이는 실제 철근의 무게 감소치에 근접함을 알 수 있었다.

  • PDF

염해환경에서의 RC보의 허용 균열폭 산정에 관한 연구 (A Study on the Allowable Crack Width of RC Beam with Corrosive Environment)

  • Kim, Dongbaek;Kwon, Soondong;An, Kwanghee
    • 한국재난정보학회 논문집
    • /
    • 제11권2호
    • /
    • pp.253-261
    • /
    • 2015
  • 콘크리트에 발생하는 균열은 구조물의 진행성 파괴로 연결되어 구조물의 안전성에 직결되는 문제이며, 철근콘크리트 구조물에 발생한 균열은 사용성 뿐만 아니라 유해물질의 침입에 따른 열화를 촉진하여 내구성 문제와 직결된다. 특히 외부 염화물 이온의 침입에 따라 철근에 발생하는 부식은 철근콘크리트 구조물의 안전성에도 큰 영향을 미친다. 따라서, 콘크리트의 균열을 제어하기 위해 초기재령 콘크리트에서의 수화, 수분이동을 규명하여 안전성 및 내구성을 확보하기 위해 허용 균열폭을 합리적으로 산정하는 방법이 필요하다. 본 연구에서는 철근콘크리트 구조물의 철근부식에 영향을 미치는 영향인자를 분석하고 부식영향인자의 변화에따른 부식의 정도를 파악할 수 있는 철근콘크리트 보를 제작하여 실험을 실시한다. 이러한 실험의 결과를 이용하여 부식영향인자를 고려한 허용 균열폭에 대한 식을 제안한다.